• Title/Summary/Keyword: 정량자기

Search Result 372, Processing Time 0.036 seconds

Overview of Arterial Spin Labeling Perfusion MRI (동맥스핀표지 관류 자기공명영상의 개요)

  • Kang, Sung-Jin;Han, Man-Seok
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.4
    • /
    • pp.145-152
    • /
    • 2017
  • The arterial spin labeling (ASL) is a magnetic resonance imaging (MRI) method that can evaluate tissue perfusion using blood in the body. The characteristic of non-invasive examinations without contrast agents and the quantitative measurement of perfusion volume is possible, which are increasingly being used for clinical and research purposes. Up to the present, The ASL method has lower SNR than the perfusion imaging method using contrast agent and because optimization of various parameter in the imaging process is difficult, Which may result in measurement errors. To improve this, ASL methods using various technologies are introduced. This paper briefly introduces the outline of ASL, its features in imaging process, various techniques, and clinical application.

Facial Expression Research according to Arbitrary Changes in Emotions through Visual Analytic Method (영상분석법에 의한 자의적 정서변화에 따른 표정연구)

  • Byun, In-Kyung;Lee, Jae-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.10
    • /
    • pp.71-81
    • /
    • 2013
  • Facial expressions decide an image for the individual, and the ability to interpret emotion from facial expressions is the core of human relations, hence recognizing emotion through facial expression is important enough to change attitude and decisions between individuals within social relations. Children with unstable attachment development, seniors, autistic group, ADHD children and depression group showed low performance results in facial expression recognizing ability tasks, and active interventions with such groups anticipates possibilities of prevention and therapeutic effects for psychological disabilities. The quantified figures that show detailed change in position of lips, eyes and cheeks anticipates for possible applications in diverse fields such as human sensibility ergonomics, korean culture and art contents, therapeutical and educational applications to overcome psychological disabilities and as methods of non-verbal communication in the globalizing multicultural society to overcome cultural differences.

Quantitative Conductivity Estimation Error due to Statistical Noise in Complex $B_1{^+}$ Map (정량적 도전율측정의 오차와 $B_1{^+}$ map의 노이즈에 관한 분석)

  • Shin, Jaewook;Lee, Joonsung;Kim, Min-Oh;Choi, Narae;Seo, Jin Keun;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.303-313
    • /
    • 2014
  • Purpose : In-vivo conductivity reconstruction using transmit field ($B_1{^+}$) information of MRI was proposed. We assessed the accuracy of conductivity reconstruction in the presence of statistical noise in complex $B_1{^+}$ map and provided a parametric model of the conductivity-to-noise ratio value. Materials and Methods: The $B_1{^+}$ distribution was simulated for a cylindrical phantom model. By adding complex Gaussian noise to the simulated $B_1{^+}$ map, quantitative conductivity estimation error was evaluated. The quantitative evaluation process was repeated over several different parameters such as Larmor frequency, object radius and SNR of $B_1{^+}$ map. A parametric model for the conductivity-to-noise ratio was developed according to these various parameters. Results: According to the simulation results, conductivity estimation is more sensitive to statistical noise in $B_1{^+}$ phase than to noise in $B_1{^+}$ magnitude. The conductivity estimate of the object of interest does not depend on the external object surrounding it. The conductivity-to-noise ratio is proportional to the signal-to-noise ratio of the $B_1{^+}$ map, Larmor frequency, the conductivity value itself and the number of averaged pixels. To estimate accurate conductivity value of the targeted tissue, SNR of $B_1{^+}$ map and adequate filtering size have to be taken into account for conductivity reconstruction process. In addition, the simulation result was verified at 3T conventional MRI scanner. Conclusion: Through all these relationships, quantitative conductivity estimation error due to statistical noise in $B_1{^+}$ map is modeled. By using this model, further issues regarding filtering and reconstruction algorithms can be investigated for MREPT.

Evaluations of Inhomogeneous Shimming in $^1$H MR Spectroscopy (자기공명분광에서 비균질 자장보정에 관한 평가)

  • Choe, Bo-Young;Baik, Hyeon-Man;Suh, Tae-Suk;Lee, Hyoung-Koo;Chun, Heung-Jae;Shim, Kyung-Sub
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.73-83
    • /
    • 2000
  • In this study, we investigate the effects of poor shimming on quantitative measurement of ratios of metabolite levels by proton magnetic resonance spectroscopy ($^1$H MRS). Coefficient of variation (COV) of metabolite ratios for point resolved spectroscopy (PRESS) and stimulated-echo acquisition mode (STEAM) spectra was evaluated from a phantom containing in vivo levels of metabolites using a conventional whole body 1.5T MR system and conventional acquisition and analysis protocol. A statistical P-value was also calculated from a linear regression for relationship of metabolite ratios. N-acetylaspartate (NAA)/ creatine (Cr) and NAA/ choline (Cho) had low COV values for the long and short TE spectra (29.1 and 27.5%; 23.8 and 12.6 %), whereas Cho/Cr and Cr/Cho had high COV values (50.0 and 68.6 %; 27.5 and 29.3 %). A linear relationship between NAA/Cr and Cho/Cr, and between NAA/Cho and Cr/Cho revealed the statistical significance in the long and short TE spectra, respectively (P < 0.0001 and P < 0.0001; P = 0.015 and P = 0.005). There was no significant relationship between Cho/NAA and Cr/NAA in the measurement (P = 0.159; P = 0.910). The present study suggested that NAA/Cr and NAA/Cho could be useful for data with poor shimming in $^1$H MR spectroscopy. In conclusion, statistical significance of metabolite ratios indicated that the Cr and Cho levels could be interpreted as a significant alteration factor in the long and short TE spectra, and then should be used with care to provide precise metabolite quantification.

  • PDF

A New Concept of Magnetic Cable for Safe Mobile Power Delivery (안전한 전력전달을 위한 새로운 형태의 자기케이블)

  • Lee, Woo-Young;Huh, Jin;Choi, Su-Yong;Rim, Chun-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.542-553
    • /
    • 2011
  • A magnetic cable that can safely deliver high frequency AC electric power in flammable or sensitive workplaces by preventing from arcs and electric shocks is firstly proposed in this paper. Several new magnetic cable structures with magnetic shields, which are composed of such cancel coil, cancel copper plate, and cancel copper pipe, were compactly implemented by considering and analyzing fringe field and thus the parallel leakage flux is drastically reduced. The output power and efficiency of a prototype magnetic cable with 1.5 m length and 5 cm gap were measured as 353.8W and 68%, where the source current and switching frequency were 10 $A_{rms}$ and 20 kHz, respectively. The proposed magnetic cables are fully analyzed and verified by finite-element method (FEM) simulations and experiments. The results are in a good agreement.

Sputering Pressure and Temperature Effects on Magnetization Reversal Behaviors of $Co(2\AA)/Pd(13\AA)$ Multilayers (스퍼터링압력 및 온도 효과에 의한 $Co(2\AA)/Pd(13\AA)$ 다층박막의 자화반전 거동)

  • 김성봉;정순영
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.4
    • /
    • pp.199-203
    • /
    • 1996
  • To study the magnetization reversal behavior of Co/Pd multilayers, we first demagnetized the samples by the field-demagnetized method and then measured initial curves and minor loops. The coercivity and the perpendicular magnetic anisotropy were obtained from the perpendicular and parallel magnetization curves measured at different temperatures. We interpret our experimental results by applying several qualitative and semiquantative approaches. From these study, we found that the magnetization reversal behavior is dominated by the domain wall pinning for all samples and the coercivity incremental tendency can be explained by Kronmuller's formula $H_c(T)\;{\propto}\;r_0.K_u$.

  • PDF

[ $^1H$ ] Magnetic Resonance Spectroscopy of Primary Central Nervous System Lymphoma (일차성 중추신경 림프종의 수소 자기공명분광법)

  • Kim Yong Sun;Lee Hui Joong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.86-93
    • /
    • 2004
  • Purpose: We evaluated $^1H$ MR spectroscopy improves the preoperative diagnosis of diffuse infiltrative type of primary central nervous system lymphomas. Materials and methods: After review of conventional MR images and medical records, we retrospectively reviewed proton MR spectra in seven patients with primary central nervous system lymphoma diagnosed by means of biopsy. Relative ratio of choline (Cho), N-acetylaspartate (NAA), and lipid-lactate (Lip-Lac) to creatine (Cr) were measured for quantitative analysis. Results: The average ratio of Cho/Cr was $1.80{\pm}0.95$, NAA/Cr was $1.34{\pm}0.41$, and Lip-Lac/Cr was $1.12{\pm}0.16$. All cases of lymphomas showed increased Lip-Lac peak. Two case of mass forming lymphoma showed decreased NAA/Cr significantly, whereas five cases of lymphoma without mass formation showed preserved NAA/Cr. Conclusion : We thought the presence of Lip-Lac peak without significant reduction of NAA on the MR spectroscopy was helpful for diagnosis of diffuse infiltrative type of central nervous system lymphoma.

  • PDF

Evaluation of the Natural Quartz with Diamagnetic and Microstructural Characterization (천연수정의 자기적 특성과 미세구조에 의한 품질평가)

  • 송오성;이기영;이정임
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.1
    • /
    • pp.27-30
    • /
    • 2003
  • Amethyst is a precious stone in Korea. As natural quartz are usually mixed with smoky quartz, amethyst, and milky quartz, we need to evaluate the amount of the amethyst quantitatively in ores. Although the optical evaluation with bare eyes has been common in assay so far, we propose that the diamagnetic property and microstructural difference characterization be the solution for the evaluating the quartz ores. In addition, FTIR (Fourier transformation infra-red) could help to identify the amethyst transparency. We report that we could evaluate the amethyst quantitatively with M-H hysteresis characterization, transmission electron microscopy (TEM) observation and FTIR characterization.

  • PDF

Bulk형 고온 초전도체를 사용한 마그네틱 베어링의 특성 연구

  • 유제환;임윤철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.337-342
    • /
    • 1998
  • 임계온도가 액체질소의 비등점(77K)보다 높은 산화물 고온 초전도체가 발견된 이후 초전도체를 여러분야에 응용하고자 하는 연구가 있어왔다. 이러한 연구중 초전도체의 자기부상특성을 이용한 마그네틱 베어링에 관한 연구가 시작되었다. 특히 최근에 임계전류밀도가 높은 덩어리형 고온 초전도체가 개발되어, 큰 부하지지력을 갖고 마찰계수가 작은 초전도 마그네틱 베어링이 가능하게 되었다. 고온 초전도체를 사용한 반발식 수동형 마그네틱 베어링은 마이스너 효과(Meissner effect)뿐 아니라 자속고정효과(Flux pinning effect)에 의해 자체적으로 외란에 대한 위치안정성을 가지며, 히스테리시스 손실에 의한 에너지 소산을 통해 외란에 대해 강한 감쇠능력을 가진다는 장점을 가지고 있으며, 대중량을 지지할 수 있다. 이러한 초전도체의 특성에 관한 정량적 수치해석은 초전도 베어링의 설계에 필수적이나 아직 국내에서는 그러한 시도가 없었다. 이러한 여건을 고려하여 본 연구에서는 Bulk형 초전도체와 자석간의 부상력 변화를 축대칭 모델로 수치해석하여 기존의 실험들과 정량적인 비교를 하여 수치해석 코드의 신뢰성을 확보하고 이를 기반으로 다양한 상황을 예측할 수 있음을 보이고자 한다.

  • PDF

A Study on measurement blood velocity according to variable changing in magnetic resonance phase contrast image (자기공명 위상대조도 기법에서 병렬영상기법 변화에 따른 혈류정량 측정에 관한 연구)

  • Cho, yong-bum;Yang, seon-wook;Son, soon-yong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2017.05a
    • /
    • pp.107-108
    • /
    • 2017
  • 3차원 위상대조도 기법의 단점인 긴 검사시간으로 인해 임상적 유용성이 떨어진다. 본 논문은 시간매개변수인 병렬영상기법(Grappa) 변경에 따른 혈류정보의 정량적 평가를 통해 차이점을 알아보고 임상적 활용정도를 평가하였다. 자체 제작한 혈류팬텀을 통해 실험하였으며, Grappa을 5번 변경하여 실험하였다. 연구결과, Grappa를 적용하지 않았을 경우 혈류속도는 평균 9.42로 총 4단계를 적용한 혈류속도 차이율은 각각(1.4, 1.5, 0.4, 1.5%)이었으며 flow와 WSS도 각각(1.4, 1.6, 0.8, 25%), (2.1, 1.4, 1.1, 0.8%)이었다. 통계적으로도 유의하지 않아 Grappa를 적용하지 않은 검사법과 혈류정보가 동일하였다.(P>0.05) 긴 검사 시간으로 인해 임상적 활용이 떨어지는 짧은 검사시간을 요하는 소아환자나 중등도 환자 또는 폐쇄공포증 환자에게 시간을 단축한 3차원 위상대조도 기법을 사용하여 단점을 보완한다면 임상적 활용가치가 높아질 것이라 사료된다.

  • PDF