Performance Test of Turbopump Assembly for 75 Ton Liquid Rocket Engine Using Model Fluid (75톤급 액체로켓엔진용 터보펌프 조립체의 상사매질 성능시험)

  • Hong, Soon-Sam;Kim, Jin-Sun;Kim, Dae-Jin;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.27-32
    • /
    • 2010
  • Performance test of a full-scale turbopump assembly for a 75 ton class liquid rocket engine was carried out at full speed. Model fluid was used as a working medium: liquid nitrogen for the oxidizer pump, water for the fuel pump, and hot air for the turbine. The turbopump was operated stably, satisfying the performance requirements. Head coefficient and flow coefficient of the pumps remained constant at the speed-increasing period. In terms of performance characteristics of pumps and turbine, the results from the turbopump assembly test showed a good agreement with those from the turbopump component tests.

  • PDF

A study on the capacitive current breaking test circuit based on international standard (국제규격에 기초한 진상전류 개폐 시험회로에 대한 연구)

  • Lee, Dong-Jun;Roh, Chang-Il;Jung, Heung-Soo;Kim, Sun-Koo;Kim, Won-Man;Kim, Sun-Ho;La, Dae-Ryeol;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.494-495
    • /
    • 2006
  • 개폐기, 차단기와 같은 스위치기어들은 지중케이블이나 가공선로, 콘덴서 뱅크에 흐르는 진상 전류의 개폐를 많이 하게 된다. 이때 진상전류의 크기는 정격 차단전류나 부하전류보다 그 크기가 매우 작다. 그러나 스위치기어 측면에서는 전압을 고려하였을 때 가혹한 시험이며, 이는 차단 후 극간에 걸리는 과도한 회복전압에 기인한다. 본 논문에서는 국제규격에서 요구하는 진상전류 시험의 회로조건들을, 회복전압 측면에 바탕을 두고 고찰해 보았다.

  • PDF

An Improvement Characteristics for Squirrel cage Induction Motor of 5-Phase 1.5KW (5상 1.5[KW] 농형 유도전동기의 특성개선)

  • Jung, Hyung-Woo;Kim, Min-Huei;Kim, Nam-Hun;Kim, Dong-Hee;Song, Hyun-Jig
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.219-220
    • /
    • 2012
  • 본 연구는 3상 보다 많은 장점을 가지는 다상 교류전동기를 연구하기 위하여 개발된 5상 1.5Kw 220V, 60Hz 농형 유도전동기의 특성 개선에 대한 연구결과이다. 연구용으로 개발된 5상 전동기는 정격운전에서 전압변동률, 속도변동률, 역율, 효율 및 운전특성 등이 많이 저하 되어 이에 대한 문제점의 개선를 요구하고 있었다. 이에 따라 기존에 개발된 고정자와 회전자의 철심 코아의 구조는 변화 하지 않고 그대로 고정된 상태를 유지하면서, 고정자 권선의 재설계와 제작을 되풀이하는 시행오차 법에 의해 최적의 전동기를 설계 제작하여 정밀 시험을 통하여 운전특성이 개선된 연구결과를 보여준다. 제시되는 특성실험 결과는 무부하시험, 구속시험, 부하특성실험, FFT 고조파 분석, 전동기의 정수 결정 및 등가회로이다.

  • PDF

The study on the dynamic characteristic and bouncing of main contact the make switch (단락전류 투입개폐기의 동작특성과 주접점 바운싱에 관한 연구)

  • Na Chil-Bong;Lee Hee-Chul;Park Jong-Wha
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.890-892
    • /
    • 2004
  • 단락발전기를 이용하여 대전류 단락시험을 실시하는 시험 설비중 단락전류 투입시 정밀한 투입 위상각 제어와 주접점 접촉시 바운싱이 없는 투입개폐기 특성이 요구된다. 이러한 특성을 만족시키기 위하여 공압식, 모터식, 유압식등 여러 종류의 투입개폐기가 사용되고 있으며 Actuator와 주 접점 형상설계 및 조립기술에 의한 바운싱이 없는 제품 제작이 중요하다. 본 논문에서는 정격전압 24 kV 단락전류 47 kA, 통전시간 0.5 s의 투입용량과 연속 반복 투입시 $\pm0.1$ ms의 오차특성을 가진 정밀급 유압식 투입개폐기의 동작특성과 핵심부품 조사 및 바운싱 제거를 위한 대책실시와 반복시험을 통하여 투입개폐기 특성에 대한 연구를 목적으로 한다.

  • PDF

Study on safety performance evaluation of stationary SOFC stack (건물용 고체산화물연료전지 스택 안전성능평가 연구)

  • Park, Tae Seong;Lee, Eun Kyung;Lee, Seung Kuk
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.1-12
    • /
    • 2018
  • The code and standards related to fuel cells were analyzed to derive the SOFC(Solid Oxide Fuel Cell) stack safety performance evaluation items and evaluation methode. Safety performance evluation of the SOFC stack was tested by quoting derived test items. The stack used in the test is an anode-supported type 2 Cell stack (Active surface area : 220cm) manufactured by MICO Inc, and SOFC stack safety performance evaluation system used for the test is self-manufactured. We conducted a leakage test, current voltage characteristic test, rated output test, and power response characteristics test. In the safety performance evaluation test, the stack showed no gas leakage, the maximum output and rated output was recorded to 65.6 W(1.41 V, 46.5 A, $422mA/cm^2$), 62.3 W(1.57 V, 40 A, $363mA/cm^2$). In the power response characteristics test verified that the output is kept stable within two seconds. At the maximum load (40 A) and the minimum load (8 A), the output was recorded 62 W and 16W in $750^{\circ}C$. This study will contribute to the universalization and to provide much safe environment of operating the solid oxide fuel cell system.

Development of Power Divider for CDMA by Thin Film Technology (THIN FILM 기술을 이용한 CDMA용 전력분배기 개발)

  • 정동언
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.2 no.2
    • /
    • pp.19-30
    • /
    • 1995
  • 일반적으로 마이크로 웨이브 영역에 사용되는 마이크로스트립 전송로는 후막 전도 선을 이용하여 RF 모듈을 구현할수 있으나 선폭의 고해상도가 전체 특성에 큰 영향을 미치 므로 고정도의 박막을 이용한 RF 모듈이 많이 개발되고 있다. 따라서 본 논고에서는 박막 제조기술을 이용하여 마이크로 웨이브 하이브리드의 한 종류인 WILKINSON 전력 분배기 를 개발하였고 공정 변수를 최적화함으로써 고특성 고신회성의 전력 분배기를 구현할 수 있 었다. 먼저 전도선의 두께의 영향을 고찰하였으며 제조 공정에 있어 GROUND 방법 /HOUSING 형상을 개선함으로써 용이하게 전력 분배기를 제조하였다. 마지막으로 MIL 규 격에 따른 전력분배기의 신뢰성 시험 항목을 제시하였고 이에 따라 정격 전력을 계산, 측정 하였다.

A Study on the Development of the Short Rate Zinc-Silver Secondary Battery (단시간 정격 아연-산화은 2차전지 개발에 관한 연구)

  • 공영경;김세웅
    • Journal of Energy Engineering
    • /
    • v.3 no.1
    • /
    • pp.77-83
    • /
    • 1994
  • 아연-산화은 2차전지는 높은 에너지 밀도의 이점을 가진 반면, 짧은 사이클수명(설계 및 사용방법에 따라 10∼200 사이클)을 가진 단점이 있다. 산화은 전극의 비싼 가격 때문에 높은 에너지 밀도가 요구되는 분야에서 제한적으로 사용되고 있다. 본 논문은 수중운동체계의 추진용으로 사용하기 위한 신뢰성이 높은 아연-산화은 전지의 개발을 다루었다. 고율방전에서 양극 활물질의 양에 따른 전압 특성과 음극활물질의 첨가제에 따른 사이클 수명 비교 시험을 실시하였다. 본 연구결과 우수한 전압 특성과 고율방전에서10회 이상의 사이클 수명을 갖는 아연-산화은 2차전지를 개발하였다.

  • PDF

Development of integrated evaluation system for electrical safety of green-car high voltage system (친환경자동차 고전압시스템의 전기안전성 통합 평가장비 개발)

  • Lee, Ki-Yeon;Lim, Young-Bae;Lee, Chang-Jun;Chae, Hyun-Byung
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.483-484
    • /
    • 2017
  • 본 논문은 친환경자동차의 보급이 활성화됨에 따라 필수적으로 확보되어야할 전기안전성을 평가하기 위한 장비개발에 관한 것으로, 기존 장비의 문제점과 효율성을 개선하기 위하여 국제기준에 적합한 통합형 평가장비를 개발하였다. 본 연구를 통하여 개발된 제품을 공인 시험기관에서 성능을 검증하였으며, 검증결과 친환경자동차의 정격에 적합한 측정 장비의 사양을 갖는 것을 확인하였다.

  • PDF

Turbopump+Gas generator Closed-loop coupled test (터보펌프+가스발생기 폐회로 연계시험)

  • Kim, Seung-Han;Nam, Chang-Ho;Kim, Cheul-Woong;Moon, Yoon-Wan;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.129-132
    • /
    • 2008
  • For the development of the 30tonf level LOx/kerosene liquid rocket engine, turbopump-gas generator closed-loop coupled tests are performed. To simulate engine operation conditions, combustion chamber was substituted by flow control orifices. In simulated engine system operation environment, chill-down procedure, startup characteristics, nominal operability of turbopump+gas generator coupled Test Plant are confirmed. Turbopump and gas generator are confirmed to operate well in simulated engine environment. The control system for regulating power and mixture ratio of Test Plant are also successfully confirmed.

  • PDF

Performance Test of High-Power Pulsed Klystron-Load (대출력 펄스 클라이스트론 부하의 성능시험)

  • Jang, S.D.;Son, Y.G.;Oh, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1756-1758
    • /
    • 2003
  • 포항 방사광 가속기의 선형가속기는 2.5GeV 전자빔 용 마이크로웨이브의 발생을 위하여 80MW 급 클라이스트론(klystron) 11대와 입사부 용 65MW 급 클라이스트론 1대를 사용한다. 80-MW 급 클라이스트론 부하를 구동하기 위하여 최대 펄스 정격출력 200 MW(400kv, 500A, 평탄도 4.4 ${\mu}s$)인 대출력 펄스 전원공급 장치(modulator)가 요구된다. 모듈레이터 시스템 용 PFN(pulse forming network) 커패시터의 충전용 입력전원으로써 최대 출력전압 50 kV, ${\pm}$ 0.5% 이내의 전압제어가 가능한 고전압 인버터 전원장치를 적용하여 클라이스트론 부하의 성능시험을 수행하였다. 클라이스트론의 RF 전력과 입력 빔의 특성을 정확히 측정하기 위하여 응답특성이 양호한 측정 장치와 정밀한 측정이 요구된다. 인버터 시스템의 적용에 따른 모듈레이터의 충전 특성을 파악하였으며, 방향성 결합기와 검파기를 설치하여 클라이스트론의 RF 출력을 측정하였다. 본 논문에서는 포항 방사광 가속기의 대출력 펄스 고주파원으로 사용되는 클라이스트론 부하의 성능시험 과정에서 수행하였던 시험장치 개선 및 특성 분석, 고전압(빔전압 320 kV) 및 RF 길들이기의 시험 결과에 관하여 고찰하고자 한다.