• Title/Summary/Keyword: 접합부 강도

Search Result 1,059, Processing Time 0.025 seconds

Evaluation of Compressive Chord Plastification of Circular Hollow Section X-joint Truss Connection (원형강관 X-이음 트러스접합부의 압축 주강관소성화 평가)

  • Lee, Kyungkoo;Sin, Yong Sup;Son, Eun Ji
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.447-454
    • /
    • 2015
  • The researches on circular hollow section(CHS) connections have been conducted continuously because of development of material properties and complex local behavior of the connections. The purpose of this study is that the effects of material strength and chord wall slenderness on chord plastification and strength of CHS X-joint truss connection under compression on branch member were evaluated. To this end, finite element analyses were performed for various connections, using ANSYS Mechanical APDL program. Based on the analysis results, the design strength of the connections according to chord plastification limit state in KBC were examined. Finally, special considerations for CHS X-joint connection design were suggested.

Classification system for figid and semi-rigid connection (강·반강 철골 접합부의 분류체계에 관한 연구)

  • Jang, Mee;Lee, Sang Sup;Mun, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.4
    • /
    • pp.351-361
    • /
    • 2001
  • The connections are classified as rigid, semi+rigid, or pinned. There are two classification systems, EC3 adn Bjorhovede et al., representatively. The EC3 boundary between rigid and semi-rigid connections is in on the whole restrictive in term of the stiffness as well as the moment capacity of connections. The boundary specified by Bjorhovede et al. may not be sufficient to assure the behavior of rigid frames in some cases. In this study, it is proposed the new classification system for steel connection that depends on the reduction factor(R) of critical buckling load for unbraced semi-rigid frame expressed by the stiffness ratio($\rho$) of beam to column and the stiffness ratio(k) of connection to beam. Finally, it is examined by experimental data that new classification criteria provides a practical boundary compared wit hteh existing classifications.

  • PDF

Analytical and Experimental Study of an Unstiffened Extended End-Plate Connection (반복하중을 받는 비보강 확장 단부판 접합부의 해석 및 실험적 연구)

  • Kim, Hee Dong;Yang, Jae Guen;Pae, Da Sol
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.6
    • /
    • pp.439-448
    • /
    • 2016
  • Extended end-plate connections(EEPC) are a type of connection applied in Pre-Engineered Building structures comprising beam-column connections of steel structures or tapered members. Extended end-plate connections(EEPC) show different behavioral characteristics owing to the influence of plate thickness, gauge distance of high strength bolt, diameter of high strength bolt frame, and the number of high strength bolts. In the USA and Europe, extended end-plate connections(EEPC) are applied in beam-column connections of steel structures in various forms; however, these are not widely applied in structures in Korea.This can be attributed to the fact that the proposal of design strength types for extended end-plate connections(EEPC), proposal of connection specifications, evaluation of seismic performance, and are not being performed appropriately. Therefore, the purpose of this study is to provide basic data for the domestic application of Unstiffened extended endplate connections. To realize this, nonlinear finite element analysis was conducted on a 12-mm thick Unstiffened extended endplate connections.

Effect of Surface Properties on Adhesive Strength of Joint of Glass Fiber/Polyester Composite Panels (유리섬유/폴리에스테르 복합재료 패널 접합부의 접착강도에 관한 표면성질의 효과)

  • Nhut, Pham Thanh;Yum, Young Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.12
    • /
    • pp.1591-1597
    • /
    • 2012
  • Adherend samples were made from unsaturated polyester and woven and mat glass fibers by the hand layup and vacuum methods. The mechanical properties of the adhesive, composite adherends, and terminal-joint and secondary-joint specimens were determined experimentally. Combinations of the experiment results and the bonding theory were used in this study. The maximum and average shear stresses were calculated based on the maximum tensile force and geometry parameters of the joint specimens. The results of the maximum and average shear stresses were compared and evaluated for six joints. The results showed that the grinding and grind/acetone joint had the highest strength among three types of terminal-joints. Similarly, the mat-mat and mat-woven joints had the highest strength among three types of secondary-joints with the same value. Conversely, no treatment and woven-woven bonding had very low strength. In each case, failure occurred always at two ends and then moved toward the middle area of the overlap length.

Strength Evaluation of Steel Box Beam-to-Column Connections with Axial Load (축방향 하중을 받는 강재 상자단면 보-기둥 접합부의 강도평가)

  • Hwang, Won Sup;Park, Moon Su;Kim, Young Pil
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.1
    • /
    • pp.117-127
    • /
    • 2007
  • In this study, we evaluate the strength of steel box beam-to-column connections subjected to axial loads in steel frame piers. The T-connection strength was reduced due to the column axial force in the two-story pier structure. To examine this phenomenon, non-linear FEM analysis was carried out and the analytical procedure was verified by comparing it with experimental results. To clarify the effect of the axial force and major design parameters in connection with strength, influence of panel zone width-thickness ratio, sectional area, and axial force was investigated using FEM analysis. Also, the theoretical strength equations were suggested by stress distribution of panel zone. The strength of the T-connection was compared with one of the one-story pier structure connections. As a result, the strength evaluation equations are proposed in consideration of the panel zone width-thickness ratio and sectional area ratio for the T-connections.

Ultimate Strength Analysis of Slab-Column Joints Subjected to Lateral Loads Using 3-Dimensional Grid Strut-Tie Model Approach (3차원 격자 스트럿-타이 모델 방법을 이용한 횡하중을 받는 슬래브-기둥 접합부의 극한강도 평가)

  • Son, Woo-Hyun;Yun, Young-Mook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.265-268
    • /
    • 2008
  • Slab-column joints have been used in the constructions of many structures and buildings. However, as the prediction of the failure behavior and ultimate strength of the joints subjected to lateral loadings is very difficult, the current building and structural design codes do not explain the failure behavior of the joints clearly. In this study, the applicability of the 3-dimensional grid strut-tie model approach, suggested for analysis and design of 3-dimensional structural concrete with disturbed regions, to the ultimate analysis and design of the joints is examined by evaluating the failure strengths of 43 slab-column joints tested to failure. The validity of the 3-dimensional grid strut-tie model approach is also verified by comparing the strength evaluation results with those by ACI 318-05 and FIB 1999.

  • PDF

Experimental Study on the Tensile Behaviors of Stud Connection with Hanger (행거로 보강된 스터드 접합부의 인장거동에 관한 실험적 연구)

  • Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.231-238
    • /
    • 2004
  • This paper presents the tensile behavior of the stud connection between reinforced concrete(RC) and steel members. Hanger reinforcements are placed around the studs to transfer the tensile and flexural loads to the opposite side of the concrete member. Eight specimens for the tensile tests are tested with variables, which are the arrangement details of hanger reinforcements, the reinforcing bars, and the embedment length of stud. The results of the tensile tests show that hanger reinforcements are effective to increase tensile strength for stud connections. Hangers and reinforcing bars near stud bolts contributed to the reduction of brittle failure. From the evaluation on the tensile strength by previous design guidelines, it was shown that CCD (Concrete Capacity Design) method was more suitable for estimation of test strength.

A Study on Deformation Capacity of High Strength Steel Beam-to-Column Connections According to Welding Detail at Beam End (보 단부 용접상세에 따른 고강도강 기둥-보 접합부의 변형능력에 관한 연구)

  • Oh, Sang Hoon;Park, Hae Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.335-348
    • /
    • 2014
  • For high-strength steel, it is difficult to be applied to flexible structural member because it have high yield ratio and low basic material's toughness. One of the great problems when using high-strength steel connections is the brittle fracture at the end of the beam member in common with general mild steel connections. In the cases of mild steel connections, it has be developed that special moment frame connection details by reinforcing structural member or improvement of welding access hole. But, it is incomplete at yet about applicability estimation of high-strength steel connections. This study is the initial step research for the applicability estimation of beam-to-column connections being applied to developed high-strength steel, HSA800. And, it studied about structural performance of the high-strength steel connections according to the details of welding access hole through full-scale test and analytical method.

SPRC 강판의 표면전처리 공정에 따른 에폭시 접착부 특성 평가

  • Kim, Hae-Yeon;Kim, Min-Su;Kim, Jong-Hun;Kim, Mok-Sun;Kim, Jun-Gi
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.56.2-56.2
    • /
    • 2011
  • 최근 철강, 알루미늄, 이종재료의 접합 등 용접이 어려운 부분에 구조용 접착제의 적용이 증가하고 있는 추세이다. 이를 위해 변성 에폭시레진을 활용한 고접합 강도, 고인성의 구조용 접착제가 연구되어 지고 있다. 피착제의 표면처리는 접합부의 접합강도를 향상시키는 방법으로 알려져 있으나 최근의 구조용 접착제는 표면 전처리 없이도 우수한 접착 특성을 보이는 것으로 기대되고 있다. 본 연구에서는 변성레진에 대해서 각종 표면처리가 접합부 특성에 미치는 영향을 조사하였다. 피착제로는 자동차용 냉연강판인 SPRC440을 사용하였고, 전처리로는 무처리 상태, SiC연마지를 이용한 연마, 아르곤 및 산소가스를 이용한 마이크로웨이브 플라즈마 표면처리, 산세 등의 표면처리를 실시하였다. 에폭시 접착제는 변성 에폭시 레진과 경화제 및 촉매제를 이용하여 직접 포뮬레이션하였다. 단일 겹치기 전단강도 시험과 T-Peel 시험은 각각 ASTM D 1002 규격에 따라 준비하였으며 인장 시험 후 파면은 SEM으로 관찰하였다.

  • PDF