• Title/Summary/Keyword: 접촉 감지

Search Result 165, Processing Time 0.023 seconds

A Contact-free type door control System with Proximity Switch (근접센서를 이용한 비접촉 방식의 출입문 감지제어 시스템)

  • Kim sung soo;Lee gi soo;Ahn Cheong Mo;Yoo Ju Hyon
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1063-1070
    • /
    • 2005
  • Number of subway train units that Seoul Metropolitan Subway Corporation as at September 2005 is 1.944 on 4 routes from 60 units at the time of commencement of operation, having grown exponentially. Along with increase in the number of passengers the role of subway as safer and expedient means of transportation is now being required. Furthermore, the Corporation has been researching on means of improving the safety and reliability of subway entry/exit doors which has become an essential task and directly effect the safety of the passengers. In this Study, has developed sensory control system for the entry/exit door of the subway train using non-contact proximity sensor as a part of review of and measures against various issues of entry/exit door of the subway trains currently under operation. In addition, this sensor system was verified through test production and tests. If this technology becomes commercialized and practically utilized in the future, it would be able to make definite contribution to the safer transportation of passengers.

  • PDF

Study on the Field Application of Odor Detector for Electric Fire Prevention (전기화재 예방용 향 검지기의 현장 적용 사례 연구)

  • Choi, Chung-Seog;Kim, Hyang-Kon;Park, Yoon-Seok;Yang, Jung-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.82-84
    • /
    • 2007
  • 본 논문에서는 전기화재 예방을 위한 향 검지기 및 향 캡슐, 향 센서의 구조와 향 검지 시스템의 동작원리에 대하여 다루었으며, 이 향 검지 시스템을 산업 현장에서 많이 사용되는 단자대(터미널 블록)와 저압용 차단기의 체결나사의 접촉 불량에 의한 이상 발열에 적용하여 향 검지 시스템의 동작 특성과 유효성에 대하여 검증하였다. 향 검지시스템을 현장에 적용하여 확인한 결과 효과적으로 이상 발열을 감지하여 음성과 표시로 관리자에게 통보해 줌을 확인할 수 있었다.

  • PDF

A Study on the Survivability of the General Purpose Warhead by Counter Mass Gun Test & Analysis (Counter Mass Gun을 이용한 표준탄의 생존성 연구)

  • 임완권;김성식;김호수;박관진;이정환
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.59-65
    • /
    • 2004
  • Survivability of the general purpose warhead during the target impact was studied. We first simulated the penetration phenomena and temporarily defined the survivability of the warhead at the impact situation. Next we launched the warhead projectiles by using Counter Mass Gun(CMG) system against the simulated specific steel target. The recovered warheads were carefully investigated and the penetration behaviors were analyzed. As a result the warhead can be hardened efficiently to enhance the survivability with the help of CMG test & analysis.

Detecting Violation of Self-Isolation System Using Blockchain (블록체인을 활용한 자가격리 이탈자 감지 시스템)

  • Park, Jae-Hoon;Jang, Kyung-Bae;Kim, Hyun-Jun;Seo, Hwa-Jeong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2020.11a
    • /
    • pp.413-415
    • /
    • 2020
  • 코로나 바이러스 감염증-19가 처음 발생한 이래로 확산세가 전혀 줄지 않고 계속 늘어나는 지금, 확진자는 물론이거니와 자가격리자에 대한 관리 또한 매우 중요하다. 국가 간 이동이나 코로나 바이러스 확진자와 접촉한 일이 있는 사람의 경우 2주간의 자가격리를 해야 되니만큼 그 숫자가 매우 많으며 그에 대한 관리 또한 중요하다. 이에 따라 본 논문에서는 블록체인을 이용하여 자가격리자에 대한 체계적이고 신뢰성 있는 관리 시스템을 제안한다. 프라이빗 블록체인 합의 알고리즘인 PBFT를 이용하여 방역당국과 같은 중앙에서 그것을 실시간으로 확인하여 자가격리 이탈자가 있을 경우 바로 알 수 있는 효과를 기대한다.

Self-Sensing and Interfacial Property of Carbon Nanofiber/Epoxy Composites with Different Aspect Ratios (형상비가 다른 탄소나노섬유/에폭시 복합재료의 자체 감지능 및 계면특성)

  • Jang, Jung-Hoon;Kim, Pyung-Gee;Kim, Sung-Ju;Wang, Zuo-Jia;Park, Joung-Man;Yoon, Dong-Jin
    • Journal of Adhesion and Interface
    • /
    • v.9 no.1
    • /
    • pp.3-8
    • /
    • 2008
  • Self-sensing was evaluated for carbon nanofiber (CNF)/epoxy composites with two different aspect ratios via electro-micromechanical technique and wettability test. Volumetric electrical resistance was measured to evaluate the comparative dispersion degree indirectly and it decreased due to the increase of electric contacts with increasing CNF concentration. The dispersion degree was evaluated indirectly by calculating coefficient of variation (COV) of volumetric electrical resistance. The CNF type A with a high aspect ratio showed better self-sensing than the case of CNF type B with a short aspect ratio. The CNF type B/epoxy composite showed little self-sensing at a concentration higher than 2 vol% probably due to poor dispersion. The apparent modulus of CNF type B was higher than that of CNF type A due to the orientation effect and the high surface area. The thermodynamic work of adhesion was consistent with the result of apparent modulus.

  • PDF

Self-Sensing and Interfacial Evaluation of Ni Nanowire/Polymer Composites Using Electro-Macromechanical Technique (전기적 미세역학적 시험법을 이용한 Ni nanowire강화 고분자 복합재료의 자체 감지능 및 계면 물성평가)

  • Kim, Sung-Ju;Yoon, Dong-Jin;Hansen George;DeVries K. Lawrence;Park, Joung-Man
    • Composites Research
    • /
    • v.19 no.5
    • /
    • pp.20-27
    • /
    • 2006
  • Self-sensing and interfacial evaluation of Ni nanowire/polymer composites were investigated using electro-macromechanical technique, which can be used fur a feasible sensing measurement on tensile and compressive loading/consequent unloading, temperature, and humidity. Mechanical properties of Ni nanowire with different aspect ratio and adding contents in either epoxy or silicone composites were measured indirectly using electro-pullout test under uniform and non-uniform cyclic loadings. Comparing apparent modulus with the conventional mechanical tensile modulus of Ni nanowire/epoxy composites, the trends were consistent with each other. Ni nanowire/epoxy composites showed the sensing response on humidity and temperature. Self-sensing on applied tensile and compressive loading/unloading was also responded for Ni nanowire/silicone composites via electrical contact resistivity showing the opposite trend between tension and compression. It can be due to the different electrically-interconnecting mechanisms of dispersed Ni nanowires embedded in silicone matrix.

Effectiveness of clinical remounting improving balanced occlusion of complete dentures (총의치 균형교합에 영향을 미치는 진료실재부착의 효과)

  • Lee, Ye-Jin;Kim, Jong-Hoi;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.328-334
    • /
    • 2020
  • Clinical remounting of complete denture is performed to refine occlusal harmony in maxillo-mandibular relation. It has been reported that patients who used adjusted dentures with clinical remounting felt less complications such as pain and discomfort in mastication. The purpose of this study was to assess effects of clinical remounting with case series. Seven patients with existing complete prosthesis were included. Clinical remounting procedure was done through interocclusal relation recording. In addition, occlusal force was measured with pressure indicating sensor and occlusal contact areas were evaluated with photo occlusion analysis. Occlusal contact areas of prosthesis were enlarged, while bite pressure was not increased. Hit and slide phenomenon of prosthesis was reduced concurrently. Clinical remounting procedure improved denture stability and increased occlusal contact area. Therefore, clinical remounting should be considered.

Experimental Study on Interaction of Water Sprayed Curtain on Hot Surface of a Window Glass and its Effects on Glass Surface Temperature in Room Fires (구획화재 시 국부복사열에 노출된 유리면의 수막접촉에 따른 급냉파열특성 관한 실험적 연구)

  • 박형주;지남용
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.124-130
    • /
    • 2003
  • This research focuses on analysis of a interaction fracture of various glasses due to contact of water sprayed curtain on hot glass surface with high temperature produced from convective heat source near glass wall. A large scaled experimental test was done in order to find the range of the glass surface temperature to be able to cause the breakage of the glasses when water droplets reach on the hot surface. This paper shows the allowable temperature of the glass surface for prevention of the cooling down breakage before water curtain droplets contact the surface. Allowable Temperature if $250^{\circ}C$ for the tempered glass but general glass is very relatively low. Therefore if the water curtain spray system was adequately activated by a thermal detector installed below ceiling adjacent glass wall with water curtain nozzle system, all hot glass would not break out by cooling water droplet's contact on the hot surface due to convective heat released by adjacent fire source near the glass wall.

Design of an Visitor Identification system for the Front Door of an Apartment using Deep learning (딥러닝 기반 이용한 공동주택현관문의 출입자 식별 시스템 설계)

  • Lee, Min-Hye;Mun, Hyung-Jin
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.4
    • /
    • pp.45-51
    • /
    • 2022
  • Fear of contact exists due to the prevention of the spread of infectious diseases such as COVID-19. When using the common entrance door of an apartment, access is possible only if the resident enters a password or obtains the resident's permission. There is the inconvenience of having to manually enter the number and password for the common entrance door to enter. Also, contactless entry is required due to COVID-19. Due to the development of ICT, users can be easily identified through the development of face recognition and voice recognition technology. The proposed method detects a visitor's face through a CCTV or camera attached to the common entrance door, recognizes the face, and identifies it as a registered resident. Then, based on the registered information of the resident, it is possible to operate without contact by interworking with the elevator on the server. In particular, if face recognition fails with a hat or mask, the visitor is identified by voice or additional authentication of the visitor is performed based on the voice message. It is possible to block the spread of contagiousness without leaving any contactless function and fingerprint information when entering and exiting the front door of an apartment house, and without the inconvenience of access.

A Study on Measurement of Penetration Depth of Steel Pipe Using the Impact-Echo Method (충격탄성파법에 의한 강관구조물 근입깊이 측정에 관한 연구)

  • Lee, Sang Hun;Kumagai, Takayuki;Endo, Takao;Han, Youn Hee
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.89-89
    • /
    • 2011
  • 도로의 가드레일 지주 근입깊이의 부족에 의한 자동차의 전락사고 이 후, 일본의 국토교통성 등의 관계자들이 그 대책 세우기에 부심해 왔으나, 기설 지주의 근입깊이를 측정할 수 있는 방법은 아직까지 알려져 있지 않으며, 현재로서는 작업의 전 과정을 비디오로 촬영하여 그 기록을 남기도록 되어있다. 그러나 그것은 상당히 비효율적인 작업으로 엄밀한 감시기능을 다하지 못하고 있으며, 감독자와 시공자의 양자로부터 계측 도구의 개발이 절실히 요구되고 있다. 일부의 초음파 측정기 업자가 가드레일 지주의 근입깊이를 측정할 수 있다고 주장하고 있으나, 시장에는 아직 나타나지 않고 있으며, 그 측정시스템의 측정여부와 성능의 검증이 이루어지지 않고 있는 상황이다. 지금까지 충격탄성파법 또는 초음파법을 이용하여, 매설된 가드레일 지주의 근입깊이를 측정한 성공사례가 정식으로 보고된 바는 없으며, 같은 강관주인 눈사태 방지책의 지주 파이프에 대한 근입깊이의 측정은 본 연구그룹의 의해 행하여진 바가 있다. 검사봉이나 해머 등으로 대상물을 두드려서 탄성파를 발생시키고, 그것을 가속도계 또는 속도계의 진동센서로 감지하여 그 파형을 분석함으로써 대상물의 치수 등을 측정하는 충격탄성파법은, 특히 콘크리트를 대상으로 공동 및 매설물 등의 탐사, 균열깊이의 측정 등에 폭 넓게 사용되고 있다. 하지만 이 측정방법을 가드레일의 지주의 근입깊이 측정에 적용할 경우, 일반적으로 행하여지는 방법, 즉 진동센서를 대상물의 상단부(캡)에 설치하는 방법으로는 접합부에 의한 탄성파의 손실과 캡의 휨 진동에 의한 노이즈 등을 해결하기가 곤란해진다. 또한 지반의 존재로 인한 진동 모드의 변화와 진동에너지의 감소 등의 문제점을 해결하지 않으면 안 된다. 본 연구는 충격탄성파법을 이용하여 지반에 설치된 눈사태 방지책이나 가드레일의 지주와 같은 강관 구조물의 근입깊이를 측정하고자 하는 연구이다. 이를 위해 진동센서를 캡이 아닌 측면부에 취부장치를 이용하여 설치함으로써 길이방향의 탄성파를 측정할 수 있도록 하고, 실제 구조물에 대해 측정을 실시하여 그 측정시스템의 성능과 유용성을 검토하고자 한다. 또한 다양한 길이의 실험용 강관 파이프를 매설하고 측정실험을 실시하여 측정시스템의 적용성에 대해서도 검토하였다. 본 연구를 통하여, 수신센서를 파이프의 측면에 선접촉하게 함으로서 종파를 감지하여 근입깊이를 포함한 파이프의 전 길이를 측정하는 본 측정시스템은 매설된 강관 구조물의 길이 측정에 기본적으로 적용 가능함을 확인할 수 있었다. 특히 오거 굴착으로 시공된 경우에는 높은 정도의 측정성능을 보여주었다. 또한 항타관입 파이프에 대해서는 지반의 영향을 고려함으로써 길이의 측정이 가능하다는 것을 확인할 수 있었다. 즉, 오거 굴착 또는 항타 관입 등 시공방법에 따라 측정결과에 대한 지반의 영향 정도가 달라지며 파형 분석 및 길이 산정시 그 영향을 고려하여야 함을 확인하였다.

  • PDF