Browse > Article
http://dx.doi.org/10.4047/jkap.2020.58.4.328

Effectiveness of clinical remounting improving balanced occlusion of complete dentures  

Lee, Ye-Jin (Department of Prosthodontics, College of Dentistry, Gangneung-Wonju National University)
Kim, Jong-Hoi (Department of Prosthodontics, College of Dentistry, Gangneung-Wonju National University)
Ko, Kyung-Ho (Department of Prosthodontics, College of Dentistry, Gangneung-Wonju National University)
Huh, Yoon-Hyuk (Department of Prosthodontics, College of Dentistry, Gangneung-Wonju National University)
Park, Chan-Jin (Department of Prosthodontics, College of Dentistry, Gangneung-Wonju National University)
Cho, Lee-Ra (Department of Prosthodontics, College of Dentistry, Gangneung-Wonju National University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.58, no.4, 2020 , pp. 328-334 More about this Journal
Abstract
Clinical remounting of complete denture is performed to refine occlusal harmony in maxillo-mandibular relation. It has been reported that patients who used adjusted dentures with clinical remounting felt less complications such as pain and discomfort in mastication. The purpose of this study was to assess effects of clinical remounting with case series. Seven patients with existing complete prosthesis were included. Clinical remounting procedure was done through interocclusal relation recording. In addition, occlusal force was measured with pressure indicating sensor and occlusal contact areas were evaluated with photo occlusion analysis. Occlusal contact areas of prosthesis were enlarged, while bite pressure was not increased. Hit and slide phenomenon of prosthesis was reduced concurrently. Clinical remounting procedure improved denture stability and increased occlusal contact area. Therefore, clinical remounting should be considered.
Keywords
Clinical remounting; Complete denture occlusion; Hit and slide; Occlusal contact areas; Occlusal force; Premature contact;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 Au AR, Tveshor M, Klineberg I. Investing procedures for immediate laboratory remounting of removable partial dentures. J Prosthet Dent 1994;72:108-12.   DOI
2 Badel T, Panduric J, Kraljevic S, Dulcic N. Checking the occlusal relationships of complete dentures via a remount procedure. Int J Periodontics Restorative Dent 2007;27:181-92.
3 Lee S-H, Kwak Y-H, Kim HJ, Lee SH, Kwak YH, Kim HJ. Complete denture artificial teeth arrangement deformation in wax denture after festooning: deformation over time. J Dent Rehabil Appl Sci 2018;34:262-9.   DOI
4 Verhaeghe TV, Linke BA, Cable CE, Mostafa N. Clinical remounting of complete dentures: A systematic review. J Prosthet Dent 2019;121:604-10.   DOI
5 Firas A M Al-Quran. A clinical evaluation of the clinical remount procedure. J Contemp Dent Pract 2005;6:48-55.   DOI
6 Manly RS. Factors affecting masticatory performance and efficiency among young adults. J Dent Res 1951;30:874-82.   DOI
7 Verma TP, Kumathalli KI, Jain V, Kumar R. Bite force recording devices - A review. J Clin Diagn Res 2017;11:ZE01-ZE05.
8 Rosen J. Clinical remount: a time saving, practice building idea for complete denture construction. J Phila Cty Dent Soc 1984;49:9.
9 Fontijn-Tekamp FA, Slagter AP, Van Der Bilt A, Van 'T Hof MA, Witter DJ, Kalk W, Jansen JA. Biting and chewing in overdentures, full dentures, and natural dentitions. J Dent Res 2000;79:1519-24.   DOI
10 Ando K, Kurosawa M, Fuwa Y, Kondo T, Goto S. A study on measuring occlusal contact area using silicone impression materials: an application of this method to the bite force measurement system using the pressure-sensitive sheet. Dent Mater J 2007;26:898-905.   DOI
11 Davies S, Al-Ani Z, Jeremiah H, Winston D, Smith P. Reliability of recording static and dynamic occlusal contact marks using transparent acetate sheet. J Prosthet Dent 2005;94:458-61.   DOI
12 Mpungose SK, Geerts GA. Analyzing complete denture occlusal contacts: Accuracy and reliability. Int J Prosthodont 2016;29:50-2.   DOI
13 Kubo H, Sato M, Kashiwagi K, Nakagawa S, Fujii T, Tanaka J, Tanaka M. Repeatability of the occlusal contact area measurements using a $BiteEye^{(R)}$ tooth contact analyzing device. J Osaka Odontol Soc 2013;76:83-8. [in Japanese]
14 Chauhan MD, Dange SP, Khalikar AN, Vaidya SP. A simplified chair-side remount technique using customized mounting platforms. J Adv Prosthodont 2012;4:170-3.   DOI
15 Firtell DN, Finzen FC, Holmes JB. The effect of clinical remount procedures on the comfort and success of complete dentures. J Prosthet Dent 1987;57:53-7.   DOI
16 Byun JS, Huh YH, Cho LR, Park CJ. A study of various factors related to satisfaction of complete denture wearers. J Dent Rehabil Appl Sci 2016;32:109-16.   DOI
17 Uchida T, Komiyama O, Kubodera S, Okamoto Y, Iida T, Wakami M. Reliability of occlusal contact examinations by using Blue $Silicone^{(R)}$. J Jpn Soc TMJ 2014;26:93-9. [in Japanese]