• Title/Summary/Keyword: 접촉응력해석

Search Result 346, Processing Time 0.03 seconds

Stress Analysis and Lead Pin Shape Design in PGA (Pin Grid Array) Package (PGA (Pin Grid Array) 패키지의 응력해석 및 Lead Pin 형상설계)

  • Cho, Seung-Hyun;Choi, Jin-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.2
    • /
    • pp.29-33
    • /
    • 2011
  • Research about the geometry design of lead pin was carried based on the normal or shear stress of the interface between a lead pin and a PCB in terms of delamination failure. The taguchi method with four design factors of three levels and FEA(Finite element Analysis) are carried under $20^{\circ}$ bending and 50 ${\mu}m$ tension of lead pin. The contact width, d2, between head round and copper pad in PCB is the highest affection factor among design factors by analysis of contribution analysis. Equivalent von Mises stress of 18.7% reduction design is obtained by the parameter design of the taguchi method. Maximum normal stress occurred at contact position between solder outer surface and a Cu pad in PCB. Also, maximum shear stress happened at contact position between solder outer surface and SR layer of PCB. From these calculated results, delamination of the PGA package may be occurred from outer interface of solder to inner interface of solder.

Finite element analysis of peri-implant bone stresses induced by root contact of orthodontic microimplant (치근접촉이 마이크로 임플란트 인접골 응력에 미치는 영향에 대한 유한요소해석)

  • Yu, Won-Jae;Kim, Mi-Ryoung;Park, Hyo-Sang;Kyung, Hee-Moon;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.41 no.1
    • /
    • pp.6-15
    • /
    • 2011
  • Objective: The aim of this study was to evaluate the biomechanical aspects of peri-implant bone upon root contact of orthodontic microimplant. Methods: Axisymmetric finite element modeling scheme was used to analyze the compressive strength of the orthodontic microimplant (Absoanchor SH1312-7, Dentos Inc., Daegu, Korea) placed into inter-radicular bone covered by 1 mm thick cortical bone, with its apical tip contacting adjacent root surface. A stepwise analysis technique was adopted to simulate the response of peri-implant bone. Areas of the bone that were subject to higher stresses than the maximum compressive strength (in case of cancellous bone) or threshold stress of 54.8MPa, which was assumed to impair the physiological remodeling of cortical bone, were removed from the FE mesh in a stepwise manner. For comparison, a control model was analyzed which simulated normal orthodontic force of 5 N at the head of the microimplant. Results: Stresses in cancellous bone were high enough to cause mechanical failure across its entire thickness. Stresses in cortical bone were more likely to cause resorptive bone remodeling than mechanical failure. The overloaded zone, initially located at the lower part of cortical plate, proliferated upward in a positive feedback mode, unaffected by stress redistribution, until the whole thickness was engaged. Conclusions: Stresses induced around a microimplant by root contact may lead to a irreversible loss of microimplant stability.

Finite element analysis on bio-mechanical behavior of composite bone plate for healing femur fracture considering contact conditions (접촉조건을 고려한 대퇴골 치료용 복합재료 고정판의 생체 역학적 거동에 관한 유한요소해석)

  • Kim, Suk-Hun;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.23 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • In this paper, finite element analyses for estimating the behavior of fractured femur just after the operation were carried out by using ABAQUS 6.71. A stainless steel bone plate and composite bone plates with various stacking angles were considered to find out the effect of bone plate properties on bone fracture healing. In order to simulate the actual state, contact conditions between the plate and bone and fractured bones were imposed on the finite element models and the whole analysis was divided by two steps; screw fastening step and load bearing step. The stress and strain distributions at the fracture site for the cases of the stainless steel and composite bone plates were analyzed and compared with. From the analyses it was found that the composite bone plate had potential advantages for effective bone fractures healing relieving stress shielding effect.

Fatigue Study for a Shift Fork of a Dual Clutch Transmission (듀얼클러치 변속기의 쉬프트 포크에 관한 피로해석 연구)

  • Kim, Kyounghoon;Jeong, Jongkyu;Won, Jongjin;Jeong, Jayil
    • Journal of Auto-vehicle Safety Association
    • /
    • v.4 no.1
    • /
    • pp.23-26
    • /
    • 2012
  • 본 논문은 듀얼클러치 변속기 변속 메커니즘 개발을 위한 동역학적 시뮬레이션 해석 및 피로수명 해석에 관한 연구이다. 캠을 이용한 쉬프트 포크의 이송으로 기어를 변속하는 개념을 갖는 쉬프트 메커니즘의 작동성 및 설계안 검증을 위해 캠의 회전 속도, 접촉면의 경계조건 및 싱크로나이저 슬리브에서의 저항을 반영한 모델링을 구성하여 동역학적 시뮬레이션을 실시하였다. 각 파트의 응력 및 변형률 발생을 해석하여 설계 개선안을 도출하고, 개선안이 반영된 최종 시작모델의 시뮬레이션 상 최대 응력 발생 시점에서 시프트 포크의 각 접촉면 별 외력 작용을 분석하여 이를 적용한 피로 해석을 진행하였다.

Effect of Various Parameters on Stress Distribution around Holes in Mechanically Fastened Composite Laminates (기계적으로 체결된 복합재료 평판에서 다양한 인자의 영향에 따른 원공 주위의 응력분포)

  • Choi Jae-Min;Chun Heoung-Jae;Byun Joon-Hyung
    • Composites Research
    • /
    • v.18 no.6
    • /
    • pp.9-18
    • /
    • 2005
  • With the wide applications of fiber-reinforced composite material in aero-structures and mechanical parts, the design of composite joints have become a very important research area because the joints are often the weakest areas in composite structures. This paper presents an analytical study of the stress distributions in mechanically single-fastened and multi-fastened composite laminates. The finite element models which treat the pin and hole contact problem using a contact stress analysis are described. A dimensionless stress concentration factor is used to compare the stress distributions in composite laminates quantitatively In the case of single-pin loaded composite laminate, the effects of stacking sequence, the ratio of a hole diameter and the width of a laminate (W/D ratio), the ratio of hole diameter and distance from edge to hole (E/D ratio), friction coefficient and clamping force are considered. In the case of multi-pin loaded composite laminate, the influence of the number of pins, pitch distance, number of rows, row spacing and hole pattern are considered. The results show that P/D ratio and E/D ratio affect more on stress distributions near the hole boundary than the other factors. In the case of multi-pin loaded composite laminate, the stress concentration in the double column case is better than the other cases of multi-pin loaded composite laminate.

두꺼운 복합적층판의 기계적 체결 거동에 대한 유한요소 해석

  • 김유준;김형근;황태경;도영대
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.29-29
    • /
    • 1997
  • 각광 받는 구조재료인 섬유강화 복합적층재에 대한 기계적 체결 거동은 본질적인 재료의 이방성에 의해서 파단강도가 파단 모우드와 매우 밀접한 관련을 갖는 것으로 알려져 있다. 따라서, 복합적층판 체결부의 정밀 구조 설계에서는 단순화에 따른 오차를 줄이고 정밀해에 의한 설계 및 해석이 요청된다. 특히, 층간응력 성분을 무시할 수 없는 두께를 갖는 복합적층 판의 기계적 체결부 해석이나 실제 구조물의 체결부에서 발생하는 굽힘이나 비틀림과 같은 하중 상태를 묘사하기 위해서도 정밀한 3차원 응력 해석은 필요하다. 하지만, 지금까지 기계적 체결부의 거동에 관한 연구는 층간응력 성분들을 어느정도 무시할 수 있는 얇은 평판에 대한 2차원 응력해석에 주로 국한되어 왔으며, 일부 수행된 체결부에 대한 3차원 응력 해석의 경우 여러 단점을 갖는 3차원 연속체 요소에 의한 유한요소 해석이 수행되었을 뿐이다.본 연구는 층간응력 성분들을 무시할 수 없는 두께를 갖는 복합적층판의 기계적 체결부 해석에 지금까지 사용되어온 3차원 연속체 요소에 의한 유한요소 방법이 갖는 단점들을 개선한 Layerwise 유한요소법을 이용하여 3차원 응력해석을 수행하였다. 특히, 선형상보성원리에 근거한 최적설계 기법을 응용하여, 기계적 체결시 핀과 적층판의 홀 사이에 발생하는 하중 전달 과정을 모사하고, 접촉력에 의한 홀 주위의 복잡하고 국부적인 응력 집중현상을 규명하여본다.

  • PDF

A Study on the Sealing Characteristics of Multi-contact O-rings (다접오링의 밀봉특성 해석에 관한 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.5
    • /
    • pp.52-57
    • /
    • 2012
  • This study presents sealing characteristics of multi-contact o-rings as functions of strain, compression stress, and contact normal stress using a FEM technique. The FEM results on the sealing characteristics show that the maximum strain, maximum compression stress, and maximum contact normal stress of multi-contact o-rings are approximately 1.7 times higher than those of conventional o-rings. This is due to a U-grooved cross section of multi-contact o-rings, and the multi-contact o-rings with a U-groove show more effective in sealing for high pressure vessels, valves, and gas equipments. And the extrusion failure in the multi- contact o-ring does not produce for an increased gas pressure due to a U-groove. This may extend sealing life compared to that of a conventional o-ring.

A Study on Convergence Contact Behavior of Friction Heat and Pad on Disk Brake (디스크 브레이크에서 마찰열과 패드에 작용하는 융합 접촉거동에 관한 연구)

  • Han, Seung-Chul;Lee, Bong-Gu
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.1
    • /
    • pp.283-289
    • /
    • 2018
  • In automotive disc brake systems, frictional heat is not uniformly dispersed for reasons such as heat flux and thermal deformation. The thermoelastic deformation due to the frictional heat affects the contact pressure distribution and the contact load may be concentrated on the contact portion on the the disc brake surface, resulting in thermoelastic instability. In this study, thermal analysis and thermal deformation analysis considering the contact between disk and pad occurred during braking through 3D axial symmetry model with reference to the experimental equation and Kao's analysis method of contact pressure of disk and pad. ANSYS is used to analyze the thermal and elastic instability problems occurring at the contact surface between the disk and the pad, considering both the thermal and mechanical loads. A 3D axisymmetric model with direct contact between the disk and the pad was constructed to more accurately observe the thermal behavior of the disk by observing the frictional surface temperature, thermal deformation and contact thermal stress of the disk.