• Title/Summary/Keyword: 접촉길이

Search Result 265, Processing Time 0.03 seconds

The Analysis of Underground Power Line Communication Channel Characteristics by Measurements (지중전력선 통신채널 측정에 의한 특성해석)

  • Shin, Dong-Hwan;Choi, Jeong-Yeon;Lee, Seung-Jun;Woo, Hui-Gon;Shin, Jai-Ho;Eom, Ki-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.86-89
    • /
    • 2009
  • In this paper, a broadband power line communication modem and network technology to develop tests with actual characteristics of the underground power line communication channel to be interpreted. Length and structure of the underground distribution line due to underground distribution line to the broadband powerline communication channels to measure the amount of attenuation on the signal generator, spectrum analyzer, such as contactless coupler was used to configure the channel measurement system. Demonstration tests in the test line as a single line by selecting the longest high-voltage lines where the two-channel measurement and signal attenuation on the noise level was measured. Measuring results degrade communication performance can be quite sure that was the presence of impulse noise, long lines, the line length was confirmed by the high-frequency attenuation appears.

  • PDF

Strength Analysis of a Slender Doubler Plate of Ship Structure subjected to the Longitudinal In-plane Compression (종방향 면내 압출하중을 받는 세장한 선박 이중판의 강도 해석)

  • Juh-Hyeok Ham
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.4
    • /
    • pp.92-105
    • /
    • 2000
  • A study for the structural strength evaluation on the slender doubler plate has been performed through the systematic evaluation process. In order to estimate the proper static strength of doubler plate subjected to the longitudinal in-plane compression, elasto-plastic large deflection analysis is introduced including the contact effect between main plate and doubler. The characteristics of stiffness and strength variation are discussed based on their results. Also, in order to compare the doubler structure with the original strength of main plate without doubler, a simple formula for the evaluation of the equivalent flat plate thickness is derived based on the additional series analysis of flat plate structure. Using this derived equation, the thickness change of a equivalent flat plate is analyzed according to the variation of various design parameters of doubler plate and some design guides are suggested in order to maintain the original strength of main plate without doubler reinforcement. Finally, correlation between derived equivalent flat plate formula and the developed buckling strength formulas by author et al. is discovered and these relations are formulated for the future development of simple strength evaluation formula of doubler plate structure.

  • PDF

Fit analysis of CAD-CAM custom abutment using micro-CT (Micro-CT를 이용한 맞춤형 CAD-CAM 지대주의 적합성 분석)

  • Min, Gwang-Seok;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.370-378
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate screw joint stability and sagittal fit between internal connection implant fixtures of two different manufacturers and customized abutments. Materials and methods: Internal connection implant systems from two different manufacturers (Biomet 3i system, Astra Tech system) were selected for this study (n=24 for each implant system, total n=48). For 3i implant system, half of the implants were connected with Ti ready-made abutments and the other half implants were connected with Ti CAD-CAM custom ones of domestic-make (Myplant, Raphabio Co., Seoul, Korea) and were classified into Group 1 and Group 2 respectively. Astra implants were divided into Group 3 and Group 4 in the same way. Micro-CT sagittal imaging was performed for fit analysis of interfaces and preloading reverse torque values (RTV) were measured. Results: In the contact length of fixture-abutment interface, there were no significant differences not only between Group 1 and Group 2 but also between Group 3 and Group 4 (Mann-Whitney test, P>.05). However, Group 2 and Group 4 showed higher contact length significantly than Group 1 and Group 3 in abutment-screw interface as well as fixture-screw one (Mann-Whitney test, P<.05). In addition, RTV was lower in CAD-CAM custom abutments compared to ready-made ones (Student t-test, P<.05). Conclusion: It is considered that domestically manufactured CAD-CAM custom abutments have similar fit at the fixture abutment interface and it could be used clinically. However, RTV of CAD-CAM custom abutments should be improved for the increase of clinical application.

Evaluation of Effect of Low Opening Operation on Increasing Wear of Bearing Bushings of Guide Vanes used in Hydropower Plants (수력발전소 가이드 베인 저개도율 운전에 따른 가이드 베인 베어링 부슁의 마모 가속효과 평가)

  • Kim, Jong-Sung;Kim, Se-Na
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1267-1274
    • /
    • 2012
  • A guide vane plays a key role in controlling the flow rate of water supplied to the turbine of a hydropower plant. It has been reported that guide vane bearing bushings are subjected to considerable wear, which requires them to be maintained. An ancillary service such as frequency control and black start causes cyclic low opening operation of the guide vanes. It is empirically well known that such operation increases the wear rate of the guide vane bearing bushing. In this study, the effect of low opening operation on the increasing wear of the guide vane bearing bushing is quantitatively assessed via finite element flow analysis, finite element stress analysis, and relative wear evaluation. As a result of the assessment, it is identified that the pressure applied on the guide vane surface increases and the contact length between the outer surface of the guide vane stem and the inner surface of the bearing bushing decreases with a decrease in the opening of the guide vane. In addition, low opening of the guide vanes results in an increase in the relative wear owing to the generation of high contact pressure on the bearing bushing surfaces.

Experimental life history of Echinostoma hortense (호르린스극구흡충의 실험실 내 생활사에 대한 연구)

  • 이순형;황순옥
    • Parasites, Hosts and Diseases
    • /
    • v.29 no.2
    • /
    • pp.161-172
    • /
    • 1991
  • The complete life cycle of Echinostoma hertense has been maintained in the laboratory, using Lymnaea persia snails and Rana nigromaculata tadpoles as the first and second intermediate hosts. ICR mice was used as the definitive host. Within the egg of 5. hotense, the miracidium was fully matured in 13 days of incubation at $29~30^{\circ}C$. The miracidium was $93.8{\times}53.6{\;}{\mu\textrm{m}}$ in average size, covered with numerous cilia of $7~11{\;}{\mu\textrm{m}}$ length. The epidermal plates were arranged in 6-8-4-2 formula. The first generation rediae ($1.19{\times}0.27{\;}mm$ in average size) were observed in 14 days after miracidial challenge to the snails, and the second generation rediae ($1.40{\times}0.26{\;}mm$ in average size) in 30 days. The average sixte of the cercaria was $295.5{\times}145.0{\;}{\mu\textrm{m}}$. Their head crown was poorly developed, and collar spines were not yet observed. After a cercarial challenge to the tadpoles, all of the tadpoles became infected and the average worm recovery rate was 88.5%. The majority of the metacercariae (75.5%) were recovered from the muscle of the tadpole's posterior body and the rest (24.3%) from their gills. The metacercariae from the tadpoles were elliptical, and $167.7{\times}129.9{\;}{\mu\textrm{m}}$ in average size. The recovery rate of adults from the mice was difFerent by the age of the metacercariae grown in the tadpoles. The metacercariae younger than 5 hrs could not infect mice whereas those older than 6 hrs could infect mice. The recovery rate became higher as the metacercaria matured, with the peak recovery rate of 90.0 % at the metacercarial age of 9 days. Thereafter the recovery rate decreased to 55.0% at the age of 50 days. As shown by the above results, the whole life cycle of E. hcrtense has been completed in the laboratory. At least 55~58 days were required to maintain one egg-to-egg cycle of E. hortense.

  • PDF

Cause Analysis in Candle Fire Investigation (양초화재 원인 감정에 관한 연구)

  • Han, Dong-Hun
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.104-109
    • /
    • 2016
  • Candle fires do not occur frequently, but can easily result in death. In this study, the thermal characteristics of candles and conditions and debris of candle fires were investigated to determine the causes of candle fires. The rates of decrease in weight of 10 candles were measured and found to be between 2.6 g/h and 6.7 g/h. Most candle fires are caused by the ignitiong of combustible materials close to them. The temperature near a candle ranges from about $200^{\circ}C$ to $400^{\circ}C$ at a distance of 1 cm and low ignition temperature materials such as papers can easily catch fire. The melting temperature of candles ranges between $50^{\circ}C$ and $70^{\circ}C$ and their major chemical components are fatty acids and normal hydrocarbons (over C20). Using pretreatment conditions involving the use of activated charcoal strips at $150^{\circ}C$ for 16 hours, the fire debris including candle residues were analyzed using a Gas-chromatograph/Mass-spectrometer (GC/MS).

Finite Element Analysis of Reinforced Concrete Masonry Infilled Frames with Different Masonry Wall Thickness Subjected to In-plane Loading (채움벽 두께에 따른 철근콘크리트 조적채움벽 골조의 면내하중에 대한 유한요소해석)

  • Kim, Chungman;Yu, Eunjong;Kim, Minjae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.85-93
    • /
    • 2016
  • In this study, finite element analyses of masonry infilled frames using a general purpose FE program, ABAQUS, were conducted. Analysis models consisted of the bare frame, infilled frames with masonry wall thickness of 0.5B and 1.0B, respectively. The masonry walls were constructed using the concrete bricks which were generally used in Korea as infilled wall. The material properties of frames and masonry for the analysis were obtained from material tests. However, four times increased the tensile strength was used for 1.0B wall, which is seemingly due to the differences in locating the bricks. The force-displacement relation and development of crack from the FE analysis were very similar to those from the experiments. From the FEA results, contact force between the frame and masonry, distribution of shear force and bending moments in frame members were analyzed. Obtained contact stress shows a trianglur distribution, and the contact length for 0.5B speciment and 1.0B specimen were close to the value estimated using ASCE 41-06 equation and ASCE 41-13 equation, respectively. Obtained shear force and bending moment distribution seems to replicate actual behavior which originates from the contact stress and gap between the frame and masonry.

Bacterial Community Structure of Food Wastewater Treatment System Combined with Rotating Biological Contactor and Tapered Aeration Reactor (회전접촉장치와 점감포기 반응조를 이용한 식품폐수 처리시설의 세균군집 구조)

  • Jeong, Soon-Jae;Nam, Ji-Hyun;Bae, Woo-Keun;Lee, Dong-Hun
    • Korean Journal of Microbiology
    • /
    • v.46 no.2
    • /
    • pp.169-176
    • /
    • 2010
  • A pilot-scale wastewater treatment plant combined with rotating biological contactor and tapered aeration reactors was operated with the wastewater discharged from a food factory for 5 months. The bacterial communities of this plant were investigated by terminal restriction fragment length polymorphism (T-RFLP) and phylogenetic analysis of 16S rRNA genes. In spite of high concentration of nitrogen and phosphorus as well as organic carbon, removal efficiency of chemical oxygen demand, total nitrogen, and total phosphorus was 98%, 93%, and 95%, respectively. Bacterial community at the initial operation stage was clearly distinguished from that of the stable operation stage. The most predominant phylum in the sample of stable stage was Bacteroidetes. Major population of operation period was Haliscomenobacter, Sphaerotilus, and candidate division TM7, which were classified as filamentous bacteria. However, sludge bulking caused by these bacteria was not observed. The population that has a close relationship with Haliscomenobacter increased during the stable operation stage, emerging as the most predominant group. These results suggest that the filamentous bacteria participated in nutrient removal when using rotating biological contactor and tapered aeration reactor.

MBE 법으로 선택적 성장된 GaN 나노선의 광/구조 특성 조사

  • Lee, Sang-Tae;Jeon, Seung-Gi;Choe, Hyo-Seok;Kim, Mun-Deok;O, Jae-Eung;Kim, Song-Gang;Yang, U-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.355-355
    • /
    • 2012
  • Si (111) 기판 위에 polystyrene (PS) bead를 사용하여 만들어진 약 100 nm 나노 구멍에 GaN나노선을 molecular beam epitaxy 법으로 성장하였다. 성장 온도와 III/V 비율 변화에 대하여 성장된 GaN 나노선의 모양과 광학적 특성은 scanning electron microscopy (SEM)와 photoluminescence (PL) 등으로 조사하였으며, InN/GaN 이종접합 및 InGaN p-n 다이오드구조를 성장하여 atomic force microscopy의 tip 접촉방법으로 전기적 특성을 조사하였다. PL 측정 결과 성장온도가 높아지면 Ga 빈자리와 관계된 3.28 eV의 donor acceptor pair (DAP) 신호와 3.42 eV의 stacking faults (SF) 결함에 기인된 발광 신호세기가 감소하는 결과를 SEM으로부터 나노선 폭 및 길이는 좁아지면서 짧아지는 것을 관측하였다. 또한 nitrogen 원자양이 증가하면서 Ga 빈자리와 관련된 3.28 eV DAP 신호가 증가하는 것을 관측하였다. 이들 결과로부터 GaN 나노선의 SF 발광 신호관련 원인에 대하여 논의 하였다. AFM을 이용한 I-V 측정으로부터 성장조건 변화에 따른 GaN 나노선 및 p-n 접합 나노선의 전도 특성을 조사하여 나노선의 소자 응용에 대한 기본적인 물리특성을 규명하였다.

  • PDF

A study on driving characteristics of thin-type ultrasonic motor (Thin-type 초음파모터의 구동특성연구)

  • Jeong, Seong-Su;Jun, Ho-Ik;Chong, Hyon-Ho;Kim, Jong-Wook;Park, Min-Ho;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.193-193
    • /
    • 2009
  • Thin-type 초음파모터의 구조는 크로스형태의 앓은 스테이터에 윗면과 아랫면에 각각 8개의 압전세라믹이 부착된 형태이고, 압전세라믹의 분극방향은 로터와 접촉하는 스테이터의 중심부인 네 개의 타점에서 순차적인 타원변위가 생성되도록 결정된다. 유한요소해석프로그램인 ATILA 5.2.4를 사용하여 형태, 길이, 두께, 스테이터 재질, 클램프특성이 최적 설계된 모델을 제작하였고, 푸쉬풀 게이지, x-y 스테이지, rpm 메터, 토크 게이지, 맨코더, AD컨버터를 이용하여 피드백 제어 구동시스템을 구성하였다. 그림 I은 마이크로컨트롤러 (ATmega)와 피드백회로를 이용한 구동 드라이버를 보여준다. 한 주기에서 1/4분주의 순차적인 네 개의 구형파를 생성하고, 이를 push-pull회로를 통하여 90도의 위상차가 나는 정현파를 생성하여 초음파 모터의 구동전원으로 사용한다. 피드백 회로인 엔코더와 AD 컨버터는 초음파모터의 속도를 피드백하여 정속도 운전을 위한 전압제어에 사용되었다. 특성 측정 결과, 제품화된 드라이버와 비교하여 큰 차이를 보이지 않았고 피드백 회로를 통하여 부하변화에 따른 속도의 극심한 변화를 0.2~0.4[N]의 범위에서 정속도 운전이 가능하였으며, 장시간의 운전에도 온도 및 속도특성이 안정적임을 확인하였다.

  • PDF