• Title/Summary/Keyword: 접지저항

Search Result 301, Processing Time 0.037 seconds

The Comparison and Analysis about Earth Resistance for Measuring of Earth Resistance by Measurement Positions of Auxiliary Poles (접지저항 측정을 위한 보조전극 위치에 따른 접지저항 비교 분석)

  • Han, Woon-Ki;Jung, Jin-Soo;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.128-133
    • /
    • 2009
  • This paper describes the comparison and analysis about measurement method of earthing resistance by positions of potential pole and current pole. In KOREA, a diagonal by 6.5 times of earthing electrode for measurement of earthing resistances but this method was almost impossible in the downtown area. For solving this problem, in this paper measuring of earthing resistance changing parameters. The parameter was a distances of earthing electrode, potential pole & current pole and the another parameter was an angles of potential pole & current pole. Analysis result, earthing resistance stability that conditions. Fist, distance from earthing electrode to current pole was over 50[m] and distance from earthing electrode to potential pole was over 30[m]. Second, angles of potential pole & current pole was over $45[^{\circ}]$.

Investigation of Coring Grounding Construction by Equivalent Radius Concept (등가반경개념에 의한 코어링 접지공사의 고찰)

  • 김세호;김일환;양문길
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.103-110
    • /
    • 2003
  • The grounding system is necessary to provide means to dissipate electric currents into the earth without exceeding any operating and equipment limits. The ground is composed of various soils and the resistivity of the soil depends on many parameters. It depends on the type of soil and varies with distance as well as with depth. Especially, soil resistivity of volcanic area such as Jeju is ve교 high and it is difficult to acquire necessary grounding resistivity. This paper introduces the efficient grounding construction using coring technique for proper grounding resistance in high resistivity area. Because it is difficult to measure the accurate resistivity of soils, their resistivities are estimated using measured value of ground resistance and equivalent radius method. Estimated resistivities are used for grounding resistance in scheduled construction region.

Combined ground impedance of equally-spaced n-vertical ground rods on circle (수직 접지전극의 정n각형배열의 합성 접지임피던스)

  • Seong, Chang-Hoon;Lee, Kyu-Sun;Kim, Ki-Bok;Kim, Tae-Ki;Lee, Bok-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1572-1573
    • /
    • 2011
  • 접지 저항을 줄이기 위해서 접지전극을 병렬로 시공할 경우 보다 쉽게 원하는 접지저항을 얻을 수 있다. 그러나 근접된 접지전극이 병렬로 매설되어 있을 경우 전위간섭의 영향으로 인해 합성 접지저항은 크게 감소하지 않는다. 현재의 전위간섭을 고려한 병렬접지전극의 합성 접지저항 및 합성 접지임피던스에 관한 연구는 많이 이루어지지 않았다. 본 논문에서 수직 접지전극을 정4각배열로 매설하였을 경우에 모의해석 방법을 제안하였으며 그 정확도를 평가하기 위해 실측값과 비교하였다.

  • PDF

The Ground Resistance Reduction Effect of o Conductive Expansion Ground Resistance Reducing Material (도전성 팽창 접지저감재의 접지저항 저감 효과)

  • Kim, Jong-Wook;Kim, Kyung-Chul;Choi, Jong-Kee;Kang, Min-Gyu;Baek, Nam-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.155-161
    • /
    • 2008
  • The grounding systems provide a low resistance path for fault or normal currents into the earth. The material for reducing ground resistance is buried around the grounding electrode to increase its effective size of the electrode and thus to obtain low ground resistance. Increasing the contacting area with the grounding electrode is effective for lowering the ground resistance in soils. Using this idea the conductive expansion ground resistance reducing material was developed. In this paper experimental data has shown that the ground resistance reduction method using proposed material is superior to using a typically available commercial ground resistance reducing material.

A Study on the Measurements/Monitoring System for the Grounding Performance of Distribution Lines (배전선로 접지 성능 측정 및 모니터링 시스템 기술에 관한 연구)

  • Kim, Kyung-Chul;Kim, Jong-Ook;Park, Sang-Young;Lee, Joo-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.74-75
    • /
    • 2006
  • 본 논문은 운전중인 배전 전주의 접지저항 측정 기술 배전선로 접지 성능 측정 및 모니터링 시스템 기술에 관한 연구를 통하여 국내의 접지측정 방법 및 문제점을 조사, 분석, 검토하였고, 우리나라 실정에 맞는 새로운 측정방식 도입에 연구의 초점을 두었다. 본 논문에서 현실적으로 문제되고 있는 접지측정방식과 유지방식에 대한 실태 및 문제점을 파악하여 변화된 접지환경에 적합한 접지측정기술과 유지방식을 도출하였다. 또한 접지저항 측정기법을 통하여 배전선로의 전주간 접지저항을 측정하였고 개발진행중에 있는 모니터링 접지저항값 획득 시스템에 대하여 언급하였다.

  • PDF

Effects of the Current Probe on Ground Resistance Measurements Using Fall-of-Potential Method (전위강하법에 의한 접지저항측정에 미치는 전류보조전극의 영향)

  • 이복희;엄주홍
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.69-77
    • /
    • 2000
  • In this paper, the effects of the positions of the potential and current probes on the measurements of the ground resistance and potential gradients with the fall-of-potential method are described and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and ground resistance of the measuring probes. The ground resistance is calculated by applying the 61.8% and rule in the fall-of-potential method, and then the potential probe is located on the straight line between the grounding electrode to be measured and the current probe. However, sometimes the grounding electrode to be measured and the measuring probes in on-site test might not be arranged on the straight line with adequate distance because there are building, road block, construction and other establishments. Provided that the grounding electrode to be measured and the measuring probes ar out of position on the straight line or have inadequate distance, the measurement of the ground resistance classically falls into an error and the measured ground resistance should be corrected. Measurements were focused on the grounding electrode system made by the ground rods of 2.4m long. It was found that the suitable separation between the grounding electrode to be measured and the current probe is more than 5 times of the length of the grounding electrode to be measured.

  • PDF

Conventional Grounding Impedance according to the Length and Soil Resistivity of the vertical grounding electrode (수직접지전극의 길이와 대지저항률에 따른 규약접지임피던스 분석)

  • Choi, Jong-Hyuk;Shin, Hee-Gyung;Lee, Bok-Hee;Kim, Tae-Ki;Ahn, Chang-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1568-1569
    • /
    • 2011
  • 최근 기후변화로 인해 낙뢰의 발생빈도가 크게 증가하고 있으며 이에 따라 피뢰시스템의 중요성이 부각되고 있다. 피뢰시스템의 원활한 기능을 수행하기 위해 접지시스템의 성능이 보장되어야 하며, 접지전극은 뇌격전류를 안전하게 대지로 방류시켜야 한다. 본 논문에서는 피뢰시스템에서 가장 흔하게 사용되는 수직접지전극을 대상으로 서지전류가 인가되었을 때 접지전극이 묻힌 대지저항률, 접지전극의 길이, 서지 전류의 파두시간 등에 따른 규약접지임피던스를 측정하고 그 특성을 분석하였다. 그 결과 대지저항률이 높은 토양과 접지전극의 길이가 짧은 경우 접지임피던스가 감소하는 용량성 특성이 지배적으로 나타나며, 대지저항률이 작고 접지전극의 길이가 긴 경우 접지임피던스가 증가하는 유도성 특성이 지배적으로 나타났다. 따라서 피뢰시스템을 위한 접지시스템 설계 시 대지저항률 및 접지전극의 길이를 고려하여 유도성 특성을 최소화 할 수 있도록 설계해야 한다.

  • PDF

수도관접지

  • 유재국
    • 전기의세계
    • /
    • v.15 no.3
    • /
    • pp.25-26
    • /
    • 1966
  • 본 고에서는 배전선로에서 고저압 혼촉시 수용가의 배전선의 대지전위상승을 압제하기 위한 2종 접지전극으로서 도시에 광범위하게 망상으로 지중에 매설되어 접지저항도 대단히 낮은 값을 갖고 있는 수도관을 지금 접지전극으로 사용하고 있는 동판 대신에 이용할 경우의 제반현상을 대상으로 하였다. 즉 수도관을 2종접지전극으로 이용할 시의 수도관에 미치는 부식문제, 수도사용자에 대한 위험성검토, 수도관의 접지저항과 접지효과등을 검토하였다.

  • PDF

Design and Installation of Shield-room Grounding System (쉴드룸 접지시스템 설계 및 시공)

  • Lee, Soo-Bong;Kim, Jung-Nyun;Baek, Sung-Hwan;Choi, Rak-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2105-2106
    • /
    • 2011
  • 본 연구에서는 보다 효과적으로 접지저항을 확보하고자 대지저항률의 측정 및 대지구조 분석, 접지시스템 설계, 접지전극 시공, 접지저항 측정 등 일련의 과정을 소개하고 그에 따라 고전압시험용 쉴드룸 접지시스템 설계 및 시공 사례를 나타내었다. 접지시스템 설계 및 시공 결과 프로그램을 이용한 설계치와 실제 시공 후 접지저항값이 거의 일치하는 것을 확인하였고, 쉴드룸에 대한 접지시스템 설계 및 시공 기술 정립을 하였다.

  • PDF

Grounding Techniques on Outside Plant (선로시설의 접지 시공 기술)

  • Oh Ho-Seok;Lee Yong-Koo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.215-218
    • /
    • 2004
  • 통신서비스를 제공하는 전송매체인 동케이블(copper cable)은 외륵 전자기적 영향으로부터 작업자 및 시설보호를 위해 $300{\sim}500m$ 마다 접지를 하고 있다. 접지는 일반 보안용 접지와 차폐용 접지로 구분할 수 있는데 보안용 접지는 100옴 이하의 접지저항을 요구하지만 차폐용 접지는 10옴 이하의 낮은 접지저항을 필요로 한다. 차폐용 접지는 대표적으로 전력선 또는 전철시설로부터 발생하는 통신선에서의 유도전압(Induced voltage)을 경감시키기 위해 사용되는 것으로 차폐케이블, 유도중화코일, 차폐선 등의 선로시설에 필요하다. 본 논문은 차폐용 접지를 시공하기 위해 적용하는 접지저감재를 활용한 보링접지 시공기술에 관한 것으로 접지저항 산출방법과 산출식에 필요한 파라메터와의 관계 등을 실제 시공결과와 비교하며 분석하였다.

  • PDF