• Title/Summary/Keyword: 점프

Search Result 246, Processing Time 0.024 seconds

A Compensation Method of Timing Signals for Communications Networks Synchronization by using Loran Signals (Loran 신호 이용 통신망 동기를 위한 타이밍 신호 보상 방안)

  • Lee, Young-Kyu;Lee, Chang-Bok;Yang, Sung-Hoon;Lee, Jong-Gu;Kong, Hyun-Dong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11A
    • /
    • pp.882-890
    • /
    • 2009
  • In this paper, we describe a compensation method that can be used for the situation where Loran receivers lose their phase lock to the received Loran signals when Loran signals are employed for the synchronization of national infrastructures such as telecommunication networks, electric power distribution and so on. In losing the phase lock to the received signals in a Loran receiver, the inner oscillator of the receiver starts free-running and the performance of the timing synchronization signals which are locked to the oscillator's phase is very severly degraded, so the timing accuracy under 1 us for a Primary Reference Clock (PRC) required in the International Telecommunications Union (ITU) G.811 standard can not be satisfied in the situation. Therefore, in this paper, we propose a method which can compensate the phase jump by using a compensation algorithm when a Loran receiver loses its phase lock and the performance evaluation of the proposed algorithm is achieved by the Maximum Time Interval Error (MTIE) of the measured data. From the performance evaluation results, it is observed that the requirement under 1 us for a PRC can be easily achieved by using the proposed algorithm showing about 0.6 us with under 30 minutes mean interval of smoothing with 1 hour period when the loss of phase lock occurs.

Development of an EEG Software for Two-Channel Cerebral Function Monitoring System (2채널 뇌기능 감시 시스템을 위한 뇌파 소프트웨어의 개발)

  • Kim, Dong-Jun;Yu, Seon-Guk;Kim, Seon-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 1999
  • This paper describes an EEG(electroencephalogram) software for two-channel cerebral function monitoring system to detect the cerebral ischemia. In the software, two-channel bipolar analog EEG signals are digitized and from the signals various EEG parameters are extracted and displayed on a monitor in real-time. Digitized EEG signal is transformed by FFT(Fast Fourier transform) and represented as CSA(compressed spectral array) and DSA(density spectral array). Additional 5 parameters, such as alpha ratio, percent delta, spectral edge frequency, total power, and difference in total power, are estimated using the FFT spectra. All of these are effectively merged in a monitor and displayed in real-time. Through animal experiments and clinical trials on men, the software is modified and enhanced. Since the software provides raw EEG, CSA, DSA, simultaneously with additional 5 parameters in a monitor, it is possible to observe patients multilaterally. For easy comparison of patient's status, reference patterns of CSA, DSA can be captured and displayed on top of the monitor. And user can mark events of surgical operation and patient's conditions on the software, this allow him jump to the points of events directly, when reviewing the recorded EEG file afterwards. Other functions, such as forward/backward jump, gain control, file management are equipped and these are operated by simple mouse click. Clinical tests in a university hospital show that the software responds accurately according to the conditions of patients and medical doctors can use the software easily.

  • PDF

The Relationships among Gait Parameters and Senior Fitness Variables in Korean Elderly People (노인 체력 측정 결과와 보행 특성의 관계)

  • Joo, Ji-Yong;Hwang, Yeon-hee;Kim, Young-Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.208-215
    • /
    • 2020
  • This study investigated the relationship among gait variables and physical fitness variables for Korean elderly people. Two hundred elderly people aged 65 to 85, (100 men and 100 women) participated in this study. They performed senior fitness test consisting of 6 tests, 3 additional physical tests (vertical jump, one leg stand, and grip force), body composition measures, and gait test. The gait test used shoes having an inertia measurement device in the outer-soles. The results indicated that the stride length, 6-min walking, lean body mass, and dumbbell curls were significantly affected by age (the above 75 group vs. the below 75 group). Among 33 measured parameters, the principal component analysis (PCA) revealed five PCs such as gait characteristics, physical features, gait variability, and fitness levels. In addition, the correlation analysis showed that the preferred walking speed was significantly, positively associated with stride length and single support time, whereas it was negatively associated with double support time and gait variability.(Ed note: please confirm my modification) In conclusion, sarcopenia should be avoided in elderly people, and resistance exercise is highly recommended to help elderly people maintain their gait ability.

In vivo Antitumor Activity and Acute, Subacute Toxicity of Keumsa (Phellinus linteus) Extracts (금사목질진흙버섯 자실체 추출물의 in vivo 항암활성 및 급성, 아 급성 독성 시험)

  • Kim, Jong-Myeung;Park, Jun-Duck;Park, Dong-Chan;Kim, Byung-Oh
    • Journal of Life Science
    • /
    • v.23 no.11
    • /
    • pp.1388-1396
    • /
    • 2013
  • This study used an S-180 cell-injected mouse model to evaluate the antitumor effects of the acute and subacute toxicity of Keumsa (Phellinus linteus) extract intravenously administrated in ICR mice. When administered intravenously (31.3-250 mg/kg body weight), Keumsa (Phellinus linteus) extract significantly inhibited the growth of the solid tumor cell. The antitumor activity of Keumsa (Phellinus linteus) extract increased in a dose-dependent manner. The highest dose (250 mg/kg body weight) was highly effective, reducing tumor formation by 42.7% compared with the control group. In the acute toxicity test, $LD_{50}$ of the Keumsa (Phellinus linteus) extract showed 632.84 mg/kg (♂) and 814.48 mg/kg (♀) after intravenous administration. In addition, liver and spleen weight were increased in a dose-dependent manner. In the subacute toxicity test, the mice were intravenously administered over the course of 28 days. The $LD_{50}$ of the Keumsa (Phellinus linteus) extract showed 355.41 mg/kg (♂) and 383.53 mg/kg (♀) after intravenous administration. The liver and spleen weight also increased in a dose-dependent manner. In the case of the group that received more than 125 mg/kg of intravenous administration, exercise capacity, such as jumping ability and agility, were significantly increased. These results suggest that Keumsa (Phellinus linteus) extract can be regarded as a potent enhancer of the innate immune response, and it can be considered as a new natural product with low toxicity that may be used as a candidate for antitumor action.

Coronaviruses: SARS, MERS and COVID-19 (코로나바이러스: 사스, 메르스 그리고 코비드-19)

  • Kim, Eun-Joong;Lee, Dongsup
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.4
    • /
    • pp.297-309
    • /
    • 2020
  • Coronaviruses were originally discovered as enzootic infections that limited to their natural animal hosts, but some strains have since crossed the animal-human species barrier and progressed to establish zoonotic diseases. Accordingly, cross-species barrier jumps resulted in the appearance of SARS-CoV, MERS-CoV, and SARS-CoV-2 that manifest as virulent human viruses. Coronaviruses contain four main structural proteins: spike, membrane, envelope, and nucleocapsid protein. The replication cycle is as follows: cell entry, genome translation, replication, assembly, and release. They were not considered highly pathogenic to humans until the outbreaks of SARS-CoV in 2002 in Guangdong province, China. The consequent outbreak of SARS in 2002 led to an epidemic with 8,422 cases, and a reported worldwide mortality rate of 11%. MERS-CoVs is highly related to camel CoVs. In 2019, a cluster of patients infected with 2019-nCoV was identified in an outbreak in Wuhan, China, and soon spread worldwide. 2019-nCoV is transmitted through the respiratory tract and then induced pneumonia. Molecular diagnosis based on upper respiratory region swabs is used for confirmation of this virus. This review examines the structure and genomic makeup of the viruses as well as the life cycle, diagnosis, and potential therapy.

A Comparison of Physical Fitness of High School Ssirum Elite-players According to Their Weight Class (고등부 씨름선수의 체급별 기초·전문체력 비교분석)

  • Jung, Joo-Ha;Kim, Sung-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.162-169
    • /
    • 2020
  • This study was conducted from November 25 to December 4, 2019, to unmask differences in physical fitness based on the weight class of high school Ssirum elite-players. A total of 28 high school Ssirum elite-players were compared and analyzed by measuring physical factors (muscle strength/power, agility, anaerobic power, aerobic ability, flexibility, and isokinetic muscle function) by weight class. Data were analyzed using SPSS ver. 23.0. One-way ANOVA was used for comparison between groups. There was no difference by weight class in terms of grip strength, sit-ups, sergeant jump, long jump, flexibility, side step, and reaction time. Evaluation of back muscle strength revealed that the group with more than 100 kg had greater strength than lower weight categories, whereas it was lower in the sit-ups, 20 m shuttle run and the relative values anaerobic power. Considering isokinetic muscle function, no difference was observed between the groups of back muscle strength and knee joint. The results of this study indicate that amongst the high school Ssirum elite-players, there is no difference in muscle power, flexibility, agility, and anaerobic average power per body weight, isokinetic trunk strength, and knee flexion strength, when evaluated according to weight class.

Branch-and-Bound Algorithm for Division of Perfect Nine Dart Combinations (퍼펙트 9 다트 조합의 나눗셈 분기한정 알고리즘)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.4
    • /
    • pp.87-94
    • /
    • 2022
  • This paper researched a study to find a combination of acquisition scores for 9 dart throws, which is the minimum number of dart tactile throws in 501 point dart games. The maximum score that can be obtained by throwing once in a dart game is 60 points, which can end the perfect dart game with 60 points eight times according to 60×8+21×1=501, and if you earn 21 points once, you can finish the game with 9 throws. This is called 9-dart finish. As such, only 18 and 14 studies on the combination of scores that can obtain 501 points with 9 throws are known, and no studies have been conducted applying the exhaustive search algorithm. This paper proposed a division branch-and-bound algorithm as a method of simplifying the O(2n) exponential time performance complexity of the typical branch-and-bound method of a exhaustive search method, to polynomial time complexity. The proposed method limited the level to 8, jumped to a quotient level of 501/60, and backtracked to explore only possible score combinations in the previous level. The possible score combinations of the nine perfect games found with the proposed algorithm were 90(101 cases).

Analysis of Differences in Muscle Activity according to Badminton Stroke Movements (배드민턴 스트로크 동작에 따른 근활성도 차이 분석)

  • Kim Hwi-Tae;Kim Ki-Hong;Jeong Huan-Jong;Kim Byung-Kwan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.2
    • /
    • pp.519-524
    • /
    • 2023
  • The purpose of this study is to construct basic data for efficient technical training by investigating the difference in muscle activity during badminton technical movements involving jump motions similar to game situations. Seven male badminton players were randomly assigned to perform smash, drop, and clear techniques, and electromyograms were measured during the implementation of three technical movements. Measured EMG was calculated by RMS and one-way ANOVA was performed. The muscle activity of the smashing motion did not show any significant difference according to the site. In drop motion, activity of PM in the upper extremity muscles was lower than that of BC and ECR, and FCR activity was lower than that of EC. The activity of ECR was higher than that of PM and FCR. The activity of ES in trunk muscles was lower than that of RF and GM. RF activity of lower extremity muscles was higher than that of ES and BF. In clear motion, the activity of TC in upper extremity muscle was higher than FCR. The activity of ES in trunk muscles was lower than that of BF. RF activity of lower extremity muscles was higher than that of BF, and BF activity was lower than that of RF and GM. The activity of GM was higher than that of BF. As for muscle activity according to badminton skills, smash and drop motions were higher than clear motions in FCR, and clear motions were higher than smash and drop motions in RA. In conclusion, it is considered that muscle activity during the badminton game is different according to the characteristics of each skill, and FCR can affect the smash and drop, and RA can affect the clear motion.

Development of a Real-time Action Recognition-Based Child Behavior Analysis Service System (실시간 행동인식 기반 아동 행동분석 서비스 시스템 개발)

  • Chimin Oh;Seonwoo Kim;Jeongmin Park;Injang Jo;Jaein Kim;Chilwoo Lee
    • Smart Media Journal
    • /
    • v.13 no.2
    • /
    • pp.68-84
    • /
    • 2024
  • This paper describes the development of a system and algorithms for high-quality welfare services by recognizing behavior development indicators (activity, sociability, danger) in children aged 0 to 2 years old using action recognition technology. Action recognition targeted 11 behaviors from lying down in 0-year-olds to jumping in 2-year-olds, using data directly obtained from actual videos provided for research purposes by three nurseries in the Gwangju and Jeonnam regions. A dataset of 1,867 actions from 425 clip videos was built for these 11 behaviors, achieving an average recognition accuracy of 97.4%. Additionally, for real-world application, the Edge Video Analyzer (EVA), a behavior analysis device, was developed and implemented with a region-specific random frame selection-based PoseC3D algorithm, capable of recognizing actions in real-time for up to 30 people in four-channel videos. The developed system was installed in three nurseries, tested by ten childcare teachers over a month, and evaluated through surveys, resulting in a perceived accuracy of 91 points and a service satisfaction score of 94 points.

The Waveform and Spectrum analysis of Tursiops truncatus (Bottlenose Dolphin) Sonar Signals on the Show at the Aquarium (쇼 학습시 병코돌고래 명음의 주파수 스펙트럼 분석)

  • 윤분도;신형일;이장욱;황두진;박태건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.2
    • /
    • pp.117-125
    • /
    • 2000
  • The waveform and spectrum analysis of Tursiops truncatus(bottlenose dolphin) sonar signals were carried out on the basis of data collected during the dolphin show at the aquarium of Cheju Pacificland from October 1998 to February 1999. When greeting to audience, the pulse width, peak frequency and spectrum level from the five dolphins'sonar signals were 3.0ms, 4.54kHz and 125.6dB, respectively. At the time of warm-up just before the show, their figures were 5.0㎳, 5.24kHz and 127.0dB, respectively. During the performance of dolphins, with singing, peak frequency ranged 3.28∼5.78kHz and spectrum level ranged 137.0∼142.0dB. With playing ring, pulse width, peak frequency and spectrum level were 7.0㎳, 2.54kHz and 135.9dB, and when playing the ball, the values were 9.0㎳, 2.78kHz and 135.2dB, respectively. The values determined from the five dolphins during jump-up out of water were : pulse width 2.0㎳, peak frequency 4.50kHz and spectrum level 126.8dB. When they responded to trainer's instructions, the values were 2.25㎳, 248kHz and 148.7dB, respectively, and greeting to audience, the peak frequency and spectrum level were 5.84kHz and 122.5dB. During swimming under water, peak frequency and spectrum level were determined to be 10.10kHz and 126.8dB. It was found that there exited close consistencies in pulse width, frequency distribution and spectrum level between whistle sounds and dolphin's sonar signals. Accordingly, the dolphins can be easily trained by using whistle sound based on the results obtained from the waveform and spectrum of the dolphin's sonar signals.

  • PDF