• Title/Summary/Keyword: 절연

Search Result 4,411, Processing Time 0.034 seconds

Development of Heat Dissipation Measuring System for 1.2-kW BLDC Motor (1.2kW 급 BLDC 모터의 열 발산 측정 시스템 개발)

  • Lee, Injun;Ye, Jungwoo;Lee, Daehun;Hwang, Pyung;Shim, Jaesool
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1423-1428
    • /
    • 2013
  • In this study, a heat dissipation measurement system is developed to analyze a 1.2-kW BLDC motor. It is important to check the temperature of the motor because an increase in temperature causes problems in the motor insulations, which in turn influences the motor life. A generator for a vehicle is installed to set up a load. We changed the load from 165 to 495 W. While the rpm varies from 2000 to 4000 under various load conditions, the changes in temperature were measured for the operating period by using a thermocouple. The results of experiments conducted under natural convection conditions suggest that the temperature was not stationary with the rpm, load, and coil of the motor and it kept increasing over $120^{\circ}C$. However, under forced convection conditions, the temperature stationarily reached $84^{\circ}C$ after 4000 s. The difference between the maximum and the minimum temperatures was $10-26^{\circ}C$ with an increase in the rpm and load. The orders of high temperature were as follows: motor coil (Ch#1), side of motor surface (Ch#5), inside of motor cap (Ch#2), upper side of motor surface (Ch#4), and inner wall of the motor (Ch#3).

A Study of a Method to Evaluate the Corrosion Resistance of Al2O3 Coated Vacuum Components for Semiconductor Equipment (반도체 장비용 Al2O3 코팅 진공부품의 내부식성 평가 연구)

  • You, S.M.;Yun, J.Y.;Kang, S.W.;Shin, J.S.;Seong, D.J.;Shin, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.175-182
    • /
    • 2008
  • This study is concerned with the evaluation of the corrosion resistance of coated semiconductor equipment parts with various processes. To select the appropriate basis for evaluation, replacement parts were observed during the semiconductor manufacturing process. This study also ran a dry corrosion test using $Al_2O_3$, which is mostly used as a coating material. This test quantitatively measured the efficiency of coated parts. Surface morphology, leakage current and breakdown voltage were also evaluated. This study showed that a dry corrosion process led to the drop of electrical properties, for example, the leakage current increase and the dielectric strength decrease. The surface morphology test displayed that surface damage is largely dependent on the exposure time to corrosive environments. By using the values that changed during the corrosion process, it may be possible to contrive a method to evaluate the efficiency of coated parts with various processes.

Poly-Si MFM (Multi-Functional-Memory) with Channel Recessed Structure

  • Park, Jin-Gwon;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.156-157
    • /
    • 2012
  • 단일 셀에서 비휘발성 및 고속의 휘발성 메모리를 모두 구동할 수 있는 다기능 메모리는 모바일 기기 및 embedded 장치의 폭발적인 성장에 있어 그 중요성이 커지고 있다. 따라서 최근 이러한 fusion기술을 응용한 unified RAM (URAM)과 같은 다기능 메모리의 연구가 주목 받고 있다. 이러한 다목적 메모리는 주로 silicon on insulator (SOI)기반의 1T-DRAM과 SONOS기술 기반의 비휘발성 메모리의 조합으로 이루어진다. 하지만 이런 다기능 메모리는 주로 단결정기반의 SOI wafer 위에서 구현되기 때문에 값이 비싸고 사용범위도 제한되어 있다. 따라서 이러한 다기능메모리를 다결정 실리콘을 이용하여 제작한다면 기판에 자유롭게 메모리 적용이 가능하고 추후 3차원 적층형 소자의 구현도 가능하기 때문에 다결정실리콘 기반의 메모리 구현은 필수적이라고 할 수 있겠다. 본 연구에서는 다결정실리콘을 이용한 channel recessed구조의 다기능메모리를 제작하였으며 각 1T-DRAM 및 NVM동작에 따른 memory 특성을 살펴보았다. 실험에 사용된 기판은 상부 비정질실리콘 100 nm, 매몰산화층 200 nm의 SOI구조의 기판을 이용하였으며 고상결정화 방법을 이용하여 $600^{\circ}C$ 24시간 열처리를 통해 결정화 시켰다. N+ poly Si을 이용하여 source/drain을 제작하였으며 RIE시스템을 이용하여 recessed channel을 형성하였다. 상부 ONO게이트 절연막은 rf sputter를 이용하여 각각 5/10/5 nm 증착하였다. $950^{\circ}C$ N2/O2 분위기에서 30초간 급속열처리를 진행하여 source/drain을 활성화 하였다. 계면상태 개선을 위해 $450^{\circ}C$ 2% H2/N2 분위기에서 30분간 열처리를 진행하였다. 제작된 Poly Si MFM에서 2.3V, 350mV/dec의 문턱전압과 subthreshold swing을 확인할 수 있었다. Nonvolatile memory mode는 FN tunneling, high-speed 1T-DRAM mode에서는 impact ionization을 이용하여 쓰기/소거 작업을 실시하였다. NVM 모드의 경우 약 2V의 memory window를 확보할 수 있었으며 $85^{\circ}C$에서의 retention 측정시에도 10년 후 약 0.9V의 memory window를 확보할 수 있었다. 1T-DRAM 모드의 경우에는 약 $30{\mu}s$의 retention과 $5{\mu}A$의 sensing margin을 확보할 수 있었다. 차후 engineered tunnel barrier기술이나 엑시머레이저를 이용한 결정화 방법을 적용한다면 device의 특성향상을 기대할 수 있을 것이다. 본 논문에서는 다결정실리콘을 이용한 다기능메모리를 제작 및 메모리 특성을 평가하였다. 제작된 소자의 단일 셀 내에서 NVM동작과 1T-DRAM동작이 모두 가능한 것을 확인할 수 있었다. 다결정실리콘의 특성상 단결정 SOI기반의 다기능 메모리에 비해 낮은 특성을 보여주었으나 이는 결정화방법, high-k절연막 적용 및 engineered tunnel barrier를 적용함으로써 해결 가능하다고 생각된다. 또한 sputter를 이용하여 저온증착된 O/N/O layer에서의 P/E특성을 확인함으로써 glass위에서의 MFM구현의 가능성도 확인할 수 있었으며, 차후 system on panel (SOP)적용도 가능할 것이라고 생각된다.

  • PDF

Stress Behavior of PSG/SiN Film for Passivation in Semiconductor Memory Device (반도체 소자의 표면보호용 PSG/SiN 절연막의 스트레스 거동)

  • Kim, Yeong-Uk;Sin, Hong-Jae;Ha, Jeong-Min;Choe, Su-Han;Lee, Jong-Gil
    • Korean Journal of Materials Research
    • /
    • v.1 no.1
    • /
    • pp.46-53
    • /
    • 1991
  • The stress of PSG (Phosphosilicate glass), USG (Undoped-silicate grass) and SiN films, which are mainly used as passivation layers in semiconductor memory devices, deposited by CVD methods has been studied as a function of film thickness and holding time in air. The stress of the PSG film or the USG film is increased in tensile state with increasing film thickness. On the other hand the stress level of the SiN film in compressive stress does not change as film thickness changes. The stress of PSG film shows the drastic change from the tensile stress to the compressive stress after the film is left 2 days in air. FTIR spectra indicated that the stress variation was due to the penetration of water molecule. It looks possible to recover the stress of about $2.5{\times}{10^9}dyne/cm^2$ by annealing treatment at $300^{\circ}C$ for 20min. The total stress of multi-layered films having the PSG film is determined mainly by the stress variation of PSG layer with holding time. The total stress of multi-layered film appears to have a functional relationship with the stress in the thickness of each film. The resistance against stress-migration of sputtered Al line increases with increasing the tensile stress for the PSG film or the USG film.

  • PDF

Histological Examination of Tissue Isolated from Fascia with a View of Meridian System (경락의 관점에서 본 근막 분리조직의 조직학적 연구)

  • Kim, Dong-Heui;Deung, Young-Kun;Chang, Byung-Soo;Jung, Han-Suk;Jin, Dan;Kwon, Ki-Rok;Lee, Kyu-Jae
    • Applied Microscopy
    • /
    • v.36 no.3
    • /
    • pp.183-194
    • /
    • 2006
  • The threadlike structures of fascia were examined by tight and electron microscopy. In order to distinguish its tissue organization, we used staining methods including hematoxylin-eosin, Masson's trichrome, Van Gieson's collagen fiber stain and Kluver-Barrera's luxol fast blue for nerve stain. Under the light microscope, the threadlike structures were composed of many collagen fibers and nerve. In higher magnification, they looked like as the bundle of tubular structures. Many myoid cell-spindle nuclei were observed in the tissue, which were taken from the fascia. It was identical with Bonghan duct known as one of meridian network theory. In the early 1960's the North Korean Bong-Han Kim showed the anatomical structures of the acupuncture points, and explained the meridian system as the concrete duct network system. According to Bonghan theory the Bonghan ducts spread throughout the body Because it is believed that the duct could have the role of signal pathway, the theory was reinvestigated in these days. All of the threadlike structures isolated from fascia shows the abundance of collagen fibers. The electron microscope examination (TEM) could confirm the well arranged collagen fiber and nerve. This investigation reveals that superficial Bohghan duct are nerve fiber parallel running with collagen fibers. We conjectured that the intermingled structure of collagen fiber, blood vessel and nerve fiber might have the role of meridian system. And the more, regardless of histological research, the study on collagen fiber as response transmitter in acupuncture treatment are in need.

Calculation of Primary Electron Collection Efficiency in Gas Electron Multipliers Based on 3D Finite Element Analysis (3차원 유한요소해석을 이용한 기체전자증폭기의 1차 전자수집효율의 계산)

  • Kim, Ho-Kyung;Cho, Min-Kook;Cheong, Min-Ho;Shon, Cheol-Soon;Hwang, Sung-Jin;Ko, Jong-Soo;Cho, Hyo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • Gas avalanche microdetectors, such as micro-strip gas chamber (MSGC), micro-gap chamber (MGC), micro-dot chamber (MDOT), etc., are operated under high voltage to induce large electron avalanche signal around micro-size anodes. Therefore, the anodes are highly exposed to electrical damage, for example, sparking because of the interaction between high electric field strength and charge multiplication around the anodes. Gas electron multiplier (GEM) is a charge preamplifying device in which charge multiplication can be confined, so that it makes that the charge multiplication region can be separate from the readout micro-anodes in 9as avalanche microdetectors possible. Primary electron collection efficiency is an important measure for the GEM performance. We have defined that the primary electron collection efficiency is the fractional number of electron trajectories reaching to the collection plane from the drift plane through the GEM holes. The electron trajectories were estimated based on 3-dimensional (3D) finite element method (FEM). In this paper, we present the primary electron collection efficiency with respect to various GEM operation parameters. This simulation work will be very useful for the better design of the GEM.

Induction coordination of the 154KV system with direct grounding (154KV 계통직접접지전환에 따른 유도협조)

  • 손필영;원준희
    • 전기의세계
    • /
    • v.18 no.1
    • /
    • pp.33-37
    • /
    • 1969
  • 한전은 1968년 11월 3일 오전 10시 04분을 기하여 154KV 전계통의 직접접지방식 전환을 단행하였다. 종전의 P.C(소고선륜) 중성점접지방식을 직접접지방식으로 전환한것으로서 전력사상 특기 할 만한 근대화사업이며 다년간을 두고 추진해온 중요과제였다. 전력계통의 확대와 복잡화는 선진국가에서도 실시하고 있는 직접접지방식의 채택을 불가변하게 하였고 또한 1차 AID송배전차관도 이의 채택을 조건부로 승인되었던 것으로서 1968년 이후에 건설되는 송변전기기는 직접접지계에서만 운전할 수 있는 절연Level 650KV급이 도입되어 부산화력발전소 3호기가 준공되는 1968년 10월말까지는 직접접지전환이 반드시 이루어져야 하는 실정에 놓여 있었다. 그런데 직접접지방식의 단점인 인접통신선에 미치는 유도장해를 해결하는 문제가 다년간을 두고 진지하게 검토되어 왔으나 해결이 늦어지고 있었다. 사유는 154KV 계통에 인근된 통신선이라면 체신부, 내무부, 교통부, 국방부등 여러기관의 것이 있는데, 유도장해보안방법과 유도보상비문제에 대하여 전력측(상공부, 한전)과 통신측(상기의 체신부등)의 견해차가 해소되지 않기 때문이었다. 그것이 1968년 5월에 와서 전력.통신쌍방이 범국가적입장에서 제반애로를 무릅쓰고 최소한의 투자로 가능한 범위내의 보안책으로서 우선 Arrester 보안방식을 채택하기로 합의되어 경제장관회의를 거쳐 시공하기에 이른것이다. 이 란을 빌려 이 사업의 필요성과 경위및 통신선유도장해방지를 위한 보안방식내용을 간단히 소개함으로써 앞으로 이 분야의 항구적인 유도대책연구에 다소나마 참고가 된다면 다행으로 생각하겠다.면서 예측강우의 질이 저하되기 시작하였으나 QPM을 합성함으로써 생산한 BQPF는 보다 신뢰성있고 양호한 결과를 얻을 수 있었다. 이러한 결과들은 향후 정량적 분포형강우 예측을 이용한 실시간 홍수유출 예측시 댐운영자는 리드타임(홍수선행시간)을 충분히 확보함으로서 안정적이고 예측 가능한 홍수조절을 하는데 도움을 줄 수 있을 것으로 기대된다. 이와 같이 다양한 단기저수지 유입량의 예측정보 제공으로 다목적댐 저수지 운영모형의 효용성을 제고하여 향후 실제 저수지 유입량 예측에 이용함으로써 저수지 단기운영효율 개선에 기여할 수 있을 것으로 사료된다.다. 이것은 여름철 강수량이 증가하고, 호우발생빈도, 특히 8월의 강수일수가 증가하고 있다는 것과 밀접한 관련이 있다. 여름과 가을에 우리나라에 영향을 미치는 태풍의 수는 뚜렷한 추세를 보이지 않으나, 2002년 루사, 2003년 매미로 인하여 각각 6조원, 4조원 이상의 막대한 피해가 발생하였다. 태풍에 의한 피해액은 GDP 대비 약 0.9%(태풍 루사)로 최근 경제상장률과 비교해 보면, 상당한 비율을 차지한다. 우리나라에 영향을 미치는 태풍은 연근해의 해수면 온도가 높아지면 세기가 강해질 가능성이 높다. 폭설과 한파일수도 평년대비 최근 10년 감소하였고 일최저기온이 영하 $10^{\circ}C$ 이하인 날도 연간 발생일수가 감소하였다. 최근 10년간 우리나라 기후의 변화특성은 기온상승과 더불어 서리종료일이 앞당겨지고 열대야가 증가하고 폭설, 한파, 겨울철 일최저기온 영하 10도 이하인 날의 감소 등이 나타나고, 여름철 재해의 원인인 호우일수는 증가하는 추세이다.

  • PDF

Accelerated Formation of Surface Films on the Degradation of LiCoO2 Cathode at High Temperature (표면 피막 형성이 LiCoO2 양극의 고온 열화에 미치는 영향)

  • Sung, Jong Hun;Hasan, Fuead;Yoo, Hyun Deog
    • Journal of the Korean Electrochemical Society
    • /
    • v.23 no.3
    • /
    • pp.57-65
    • /
    • 2020
  • It is crucial to investigate the thermal degradation of lithium-ion batteries (LIBs) to understand the possible malfunction at high temperature. Herein, we investigated the effects of surface film formation on the thermal degradation of lithium cobalt oxide (LiCoO2, LCO) cathode that is one of representative cathode materials. Cycling test at 60℃ exhibited poorer cycleability compared with the cycling at 25℃. Cathodes after the initial 5 cycles at 60℃ (60-LCO) exhibited higher impedance compared to the cathode after initial 5 cycles at 25℃ (25-LCO), resulting in the lower rate capability upon subsequent cycling at 25℃, although the capacity values were similar at the lowest C-rate of 0.1C. In order to understand degradation of the LCO cathode at the high temperature, we analyzed the cathodes surface using X-ray photoelectron spectroscopy (XPS). Among various peaks, intensity of lithium hydroxide (LiOH) increased substantially after the operation at 60℃, and the C-C signal that represents the conductive agent was distinctly lower on 60-LCO compared to 25-LCO. These results pointed to an excessive formation of cathode-electrolyte interphase including LiOH at 60℃, leading to the increase in the resistance and the resultant degradation in the electrochemical performances.

Variation of Magnetic Properties of Fe-Si Compressed Cores with Si Content (Si 함량에 따른 Fe-Si 압분코어의 자기적 특성)

  • Jang, Pyung-Woo;Lee, Bong-Han;Choi, Gwang-Bo
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.1
    • /
    • pp.13-17
    • /
    • 2010
  • Fe-3, 4.2 and 6.8% Si compressed cores were fabricated, and then electrical resistivity, AC and DC magnetic properties, microhardness, and other properties were analyzed in order to know whether best soft magnetic properties could be also obtained in an Fe-Si compressed core with the well-known composition of Fe-6.5% Si. With increasing the silicon content, eddy current loss and hysteresis loss decreased and increased, respectively, so that a minimum total loss was not obtained in the well-known Fe-6.8 % Si cores, but obtained in the Fe-4.2 % Si cores. Also electrical resistivity of the cores and hardness of the particles increased monotonously with silicon content so that compaction ratio of the cores decreased. B2 and $DO_3$ ordered phase could be observed only in Fe-6.8% Si powder. A minimum loss and highest permeability of the Fe-4.2 % Si cores can be explained by the ratio of specific electrical resistivity of insulator to that of magnetic particles, micro-hardness, compaction ratio and demagnetization coefficient of the Fe-Si powder particles with silicon content.

Mechanical, Thermal and Electrical Properties of Polymer Nanocomposites Reinforced with Multiwalled Carbon Nanotubes (다중벽 카본나노튜브가 보강된 고분자 나노복합체의 기계적, 열적, 전기적 특성)

  • Kook, Jeong-Ho;Huh, Mong-Young;Yang, Hoon;Shin, Dong-Hoon;Park, Dae-Hee;Nah, Chang-Woon
    • Polymer(Korea)
    • /
    • v.31 no.5
    • /
    • pp.422-427
    • /
    • 2007
  • Semiconducting layers are thin rubber film between electrical cable wire and insulating polymer layers having a volume resistivity of ${\sim}10^2{\Omega}cm$. Commercial semiconducting layers ire composed of polymer composites reinforced with more than 30 wt% of carbon blacks. A new semiconducting material was suggested in this study based on the carbon nanotube(CNT)-reinforced polymer nanocomposites. CNT-reinforced polymer nanocomposites were prepared by solution mixing and precipitation with various polymer type and dual filler system. The mechanical, thermal and electrical properties were investigated as a function of polymer type and dual filler system based on CNT and carbon black. The volume resistivity of composites was strongly related with the crystallinity of polymer matrix. With the decreased crystallinity, the volume resistivity decreased linearly until a critical point, and it remained constant with further decreasing the crystallinity. Dual filler system also affected the volume resistivity. The CNT-reinforced nanocomposite showed the lowest volume resistivity. When a small amount of carbon black(CB) was replaced the CNT, the crystallinity increased considerably leading to a higher volume resistivity.