• Title/Summary/Keyword: 절연장치

Search Result 454, Processing Time 0.029 seconds

Development of Active Micro-Vibration Isolator using Electromagnet (전자석을 사용한 능동 미소진동 절연장치 개발)

  • Lee, Dae-Oen;Park, Gee-Yong;Han, Jae-Hung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.390-394
    • /
    • 2013
  • Observation satellites carrying high precision optical payload require extremely stringent pointing stability that may be violated in the presence of the disturbances corning from reaction wheels, cryocoolers or other actuating components onboard the satellite. The most common method to protect the sensitive payloads from external disturbances is implementation of vibration isolator. In this paper development of a single axis active vibration isolator using electromagnet and its performance in isolating micro-vibration is presented. The main components of the developed isolator are membrane structure providing the isolator with the required stiffness and an electromagnet for active control. The performance test results show that additional damping can be achieved by active control without degrading isolation performance in high frequency region and that the developed isolator can effectively isolate micro-vibration.

  • PDF

Countermeasures to Irregulor Abrasion of Section Insulators for Electric Railroad Catenary (전차선 절연구분장치 절연재의 이상마모 대책)

  • 최규형
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.87-94
    • /
    • 2002
  • As a section insulator dividing the electric railroad catenaries with different phases, the AC/DC section insulator which divides AC and DC railroad catenary have the complex structure, and suffer irregular abrasion on the surface or insulator rods when it is installed at the underground railroad. This paper intended as an investigation of the irregular abrasion of section insulators, provides the field measurements of abrasion level along insulator length and the abrasion patterns. The height variation of insulator parts and the balding length of insulators against pantograph's contact force are analysed experimentally, and the irregular abrasion mechanism is clarified with the help of theoretical analysis on the interaction between pantographs and section insulators. On the basis of experimental and theoretical analysis, the countermeasures to reduce the irregular abrasion are provided too.

Characteristics of the Surge Protector for Underground Cable (지중케이블의 절연통 보호대책 및 방식층 보호장치의 특성)

  • Kim, S.S.;Cho, H.G.;Park, T.G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.72-75
    • /
    • 2001
  • 전력케이블 선로에 가해지는 전압은 상시교류전압이외에 지락 등에 의한 사용주파과전압과 뇌써지와 같은 써지성 과전압이 있다. 써지성 과전압이 케이블 심선에 침입할 경우 종단접속부나 절연접속함의 접속점은 절연통 양단 및 시스와 대지간에 고전압이 발생하여 케이블심선-시스간 시스-대지간의 써지임피던스 비에 따라 과전압이 발생하며, 이와 같이 써지성 과전압이 방식층의 충격내전압치를 초과할 경우 방식층을 보호하기 위한 대책이 필요하며 그 보호장치로 절연통 보호장치를 사용하는 것이 일반적이다. 절연통에 대한 보호대책과, 설계 제작된 절연통 보호장치에 대한 주요시험항목을 실시하여 항목별 그 특성을 검토하고 절연통 보호장치의 지중송전선로에서 사용되는 조건인 열적내량을 검증하는 충격전류시험과 침수에 의한 기밀성능을 검증하는 내수성능시험을 실시함으로써 그 중요성을 인식할 수 있었다.

  • PDF

Basic Characteristics of the Surge Protector for 154 kV Underground Cable (154kV 지중케이블 절연통 보호장치의 기본특성 평가)

  • 김석수;조한구;박태곤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.604-607
    • /
    • 2000
  • 뇌써지가 케이블 심선에 침입할 경우 케이블심선-시스간과 시스와 대지간의 써지임피던스 비에 따라 과 전압이 발생하며, 이와 같이 써지성 과전압이 방식층의 충격내전압치륵 초과할 경우 방식층을 보호하기 위 한 대책이 필요하며 그 보호장치로 절연통 보호장치를 사용하는 것이 일반적이다. 설계, 제작된 절연통 보호장치에 대해 절연저항시험, 동작개시전압시험, 뇌충격제한전압시험, 충격전류시험, 방전하에서 교류내전압시험, 절연성능시험 및 내수성능시험을 실시하여 내수성능시험을 제외한 모든 시험항목에서는 그 결과가 양호하나, 내수성능시험에서는 미세한 홈으로 물이 침투되어 불량이 발생함에 따라 절연통 보호장치는 지 중송전선로에 사용되는 보호장치로서 지중조건에서의 수밀 및 기밀특성 더욱 우수해야 하므로 내수성능시험의 중요성을 인식할 수 있었다.

  • PDF

Compressed gas as the high voltage insulation material (고전압 절연물로써의 압축기체)

  • 이동인
    • 전기의세계
    • /
    • v.28 no.8
    • /
    • pp.3-7
    • /
    • 1979
  • 일반적으로 고전압의 절연물로 사용되어 지고 있는 gas를 고기압으로 압축하여 사용하므로써 그 압력에 비례하여 절연내력을 증가시킬 수 있다는 사실을 알고 있다. 따라서 전력계통에서 그 사용전압이 점차 초고전압화 됨에 따라 그에 따른 절연물로써 압축가스의 이용이 증가일로에 있으며 어떤 압축가스를 사용하므로서 높은 절연내력을 얻을 수 있음은 물론이거니와 열적으로 안정하며 전도성이 좋고 또한 교류송전선로에 이용될때는 Corona가 발생하는 가능성도 적으며 유전손실도 줄일 수 있는 장점을 가지고 있다. 특히 이러한 압축가스는 고전압발생장치, 고전압변환장치 및 고전압용 개폐기등의 절연에 상당히 많이 사용되고 있으며 5기압 정도의 부성기체는 고전압변압기나 Compact Substation의 절연물로써 점차 이용이 증가되고 있다.

  • PDF

A Comparison of Vibration Isolation Characteristics of Various Forms of Passive Vibration Isolator (다양한 수동 진동 절연 장치의 진동 절연 특성 비교)

  • Lee, Dae-Oen;Han, Jae-Hung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.9
    • /
    • pp.817-824
    • /
    • 2012
  • Transmission of unwanted vibration to sensitive systems can cause various problems including performance degradation and system malfunction. The most common approach to limit the transmission of harmful vibration disturbances to the sensitive system is adapting passive vibration isolator. The classical passive vibration isolator comprising a viscous damper and spring element in parallel, however, exhibits conflicting performance characteristics in that low amplification at the resonance, which is desirable, can only be achieved at the sacrifice of vibration isolation performance in high frequency region, which is undesirable. In this paper, vibration isolation characteristics of various passive isolator schemes in literature to circumvent this conflict are introduced and compared.

A Comparison of Vibration Isolation Characteristics of Various Forms of Passive Vibration Isolator (다양한 수동 진동 절연 장치의 진동 절연 특성 비교)

  • Lee, Dae-Oen;Han, Jae-Hung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.232-237
    • /
    • 2012
  • Transmission of unwanted vibration to sensitive systems can cause various problems including performance degradation and system malfunction. The most common approach to limit the transmission of harmful vibration disturbances to the sensitive system is adapting passive vibration isolator. The classical passive vibration isolator comprising a viscous damper and spring element in parallel, however, exhibits conflicting performance characteristics in that low amplification at the resonance, which is desirable, can only be achieved at the sacrifice of vibration isolation performance in high frequency region, which is undesirable. In this paper, vibration isolation characteristics of various passive isolator schemes in literature to circumvent this conflict are introduced and compared.

  • PDF

Performance Standard Review of Section Insulator and Post Insulator for Overhead Conductor Rail (강체전차선로용 장간애자 및 절연구분장치 성능기준 검토)

  • Cho, Ho Rung;Lee, Sang Sik;Kim, Jae Sang;Lee, Kiwon;Park, Younchul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1589-1590
    • /
    • 2015
  • 전기철도차량에 전기를 공급하는 가공 전차선로 시스템은 커티너리(catenary) 방식과 강체가선 방식으로 구분 할 수 있으며 강체가선 방식은 DC 급전구간에서 주로 사용하고 있는 T-bar 시스템과 AC 급전구간에서 주로 사용하는 R-bar 시스템으로 구분 할 수 있다. 최근 국내환경에 적합한 고속용 R-bar 시스템의 개발을 진행하고 있으며 여기에 필요한 브래킷 지지 및 절연용 장간애자와 동상구분을 위한 절연구분장치 개발을 진행하고 있다. 따라서 국내에 수입하여 적용하고 있는 저속, 고속 R-bar 시스템용 장간애자 및 절연구분장치의 성능기준을 확인하고 개발에 필요한 성능기준을 검토 적용하여 고속 R-bar 시스템용 장간애자 및 절연구분장치 개발을 진행할 예정이다.

  • PDF

Study on Partial Discharge Characteristics under Insulating Material of Substation Facilities (변전기기 절연매질에서 발생하는 부분방전신호 특성분석)

  • Han, Ki-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.153-154
    • /
    • 2008
  • 변전기기의 주요 절연매질인 절연유 및 $SF_6$ 가스에서 절연불량으로 부분방전이 발생할때 방사되는 전자기파 특성을 측정, 분석 하였다. 부분방전 발생기구로 부유전극을 제작하여 실험하였으며 부분 방전에 의한 전자기파 신호의 특성을 분석한 결과 변압기 주 절연물인 절연유에서 발생하는 부분방전신호가 크고 높은 주파수의 신호가 발생하였고, 가스절연개폐장치 주 절연물인 $SF_6$ 가스에서 발생하는 부분방전신호도 비교적 높은 주파수 신호가 발생하였다. 본 분석결과는 변전소 주요 설비인 변압기 및 가스절연개폐장치에서 발생가능한 절연이상을 진단하기 위한 전자기파를 이용한 부분방전 분석기술 개발에 응용할 예정이다.

  • PDF

Partial Discharge of Ignition Coil for Automotive (자동차 점화코일의 부분방전특성)

  • Shin, Jong-Yeol;Kim, Tag-Yong;Byun, Du-Gyoon;Kim, Weon-Jong;Lee, Soo-Won;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.239-242
    • /
    • 2003
  • 자동차 점화장치는 전원으로부터 공급된 낮은 전압을 점화코일을 통하여 연소실의 혼합기를 연소시키기에 충분한 고전압을 발생시키는 장치이며, 점화장치의 핵심은 점화코일이다. 이 점화코일은 절연성능이 우수한 절연재료가 사용되지만 고전압의 발생으로 점화코일 내부에서 일어나는 전기적 열화로 인해 누설전류가 흐르게 되어 전기적 고장을 초래할 수 있다. 이로 인하여 절연재료의 수명은 단축되며, 또한 점화코일에 전류가 흐름으로써 코일 내부에서 발생하는 온도변화에 따른 절연열화로 점화코일의 성능이 저하될 수 있다. 따라서 본 연구에서는 점화코일에 사용되고 있는 절연재료에 전압이 인가될 때 발생할 수 있는 비파괴검사의 일종인 부분방전 측정을 통하여 전압변화에 따른 에폭시 성형 점화코일의 위상각($\Phi$) - 방전전하량(q) - 발생빈도수(n)의 특성 변화를 조사하고 분석함으로써 점화코일의 수명을 예측하여 자동차 점화장치의 성능진단과 정보제공을 자동차 전기장치의 발전에 도움이 될 것을 기대하며, 온도상승에 따른 점화코일의 부분방전 특성을 실험하고 분석하였다.

  • PDF