• Title/Summary/Keyword: 절개

Search Result 1,038, Processing Time 0.035 seconds

Characteristics and Energy Absorbing Capacity for Rockfall Protection Fence from In-Situ Rockfall Tests (현장 낙석실험을 통한 낙석방지울타리의 특성 및 성능 평가)

  • 구호본;박혁진;백영식
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.111-121
    • /
    • 2001
  • Rockfall protection fences are used for diminishing rockfall damage in roads side slopes. In order to install the fences in effective way, the conditions of rock slopes and total predicted impact energy of fa11ing rock should be considered. However, the fences have been constructed without any consideration for lithology, height and slope angle of rock slope in Korea. In addition, the information about the performance of the protection fences, which should be evaluated by in-situ test or laboratory test in order to check out the practical use in the field, is not available. Therefore, in design manual for the rockfall protection fence, the specific details for the installation of this type of fence are not provided yet. The full sized rockfall in situ test was carried out for the calculation of falling energy of rock and the evaluation of the maximum energy absorbing capacity of fence. For this test, the rock slopes whose heights are about 20 m and dip angle of 65 degree, have been chosen. This is because those geometries are mean height and slope angle of most road cut slopes along Korean national highway. Based on the preliminary simulation procedure, four different sizes of concrete ball (0.7, 1.3, 2.3 and 4.3 ton) were prepared and flour different types of protection fence were constructed. The results of this test provide information about the maximum energy absorbing capacity of the fence, kinetic energy of rockfall and restitution coefficient, and these results can be utilized in the establishment of rockfall fence design and construction manual.

  • PDF

Accuracy of Astigmatic Correction Using Toric Intraocular Lens by Position and Size of Corneal Incision (각막절개 위치와 크기에 따른 난시교정인공수정체의 난시교정의 정확성)

  • Park, Wookyung;Kim, Man Soo;Kim, Eun Chul
    • Journal of The Korean Ophthalmological Society
    • /
    • v.60 no.2
    • /
    • pp.126-134
    • /
    • 2019
  • Purpose: To assess the accuracy of toric intraocular lens (IOL) implantation by the location and size of the corneal incision. Methods: We retrospectively reviewed the medical records of 98 patients (98 eyes) who underwent phacoemulsification with toric IOL implantation from January 2014 to March 2017. The patients were divided into two groups: group 1 got an incision of the superior side of the cornea (n = 54) and group 2 received an incision on the temporal side of the eye (n = 44). For both groups, incisions were made at their steep corneal astigmatism axises. Each group was further divided into subgroups for whom different sized blades were employed (2.75 vs. 2.2 mm widths). We measured the refractive index and autokeratometric parameters. We postoperatively assessed residual astigmatism and any reduction thereof. Results: In both groups, uncorrected and best-corrected visual acuity, refraction cylinder astigmatism, and autokeratometric astigmatism improved statistically. Between two groups, corneal astigmatism decrease was not significant. Residual astigmatism also showed no significant differences between the two. Patients in both groups treated using 2.75 mm wide blades exhibited greater increases in corneal astigmatism. Conclusions: During cataract surgery, precise correction of astigmatism via toric IOL implantation is possible when surgically induced astigmatism is minimized by careful choice of the location and size of the corneal incision.

Analysis of Plate Cutting Performance of Aluminum Linear Shaped Charge with Non-uniform Penetration Performance (불균일한 침투성능을 갖는 알루미늄 선상성형작약의 판재 절개성능 분석)

  • Young Jae Kim
    • Journal of the Korea Society for Simulation
    • /
    • v.33 no.3
    • /
    • pp.27-35
    • /
    • 2024
  • Generally, an Linear Shaped Charge(LSC) is used for cutting a mechanical structure of various weapon systems. The penetration performance of an LSC is subjected to the type of explosive, the amount of explosive charge per unit length, the type of sheath material, stand-off distance from the target etc. In addition, the non-uniform cross-sectional shape originated from the manufacturing process may affect penetration performance. In this study, in order to analyze the penetration performance of an LSC, Computed Tomography(CT) images of its internal shape were taken and penetration experiments of the LSC were performed on a square metal bar. The experimental results showed that the penetration depths varied depending on the longitudinal position of the LSC, and at some locations, did not meet the required cutting performance. The LSC used in the experiment was manufactured to be able to cut a 4 mm plate, but in the results of the penetration performance experiment, there were many locations where the penetration depth was less than 4 mm. To find this reason, the penetration performance that did not meet the required cutting performance was simulated through AUTODYN based numerical analysis to confirm whether the LSC is cut in the plate. Through numerical analysis, it was confirmed that the penetration performance of an LSC varies depending on the thickness of the incision target due to the distribution of stress.

Minimal Skin Incision with Full Sternotomy for Congenital Heart Surgery (최소 피부 절개술을 이용한 선천성 심장 질환 수술)

  • Park, Choung-Kyu;Park, Pyo-Won;Jun, Tae-Gook;Park, Kay-Hyun;Chae, Hurn
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.368-372
    • /
    • 1999
  • Background: Although there have been few reports about minimal skin incision for the repair of congenital heart lesions, minimizing an unsightly scar is a particularly important factor in growing children. We have adopted a technique that permits standard full sternotomy, conventional open chest cardiopulmonary bypass, aortic cross-clamping, left atrial vent, and antegrade cardioplegia with minimal surgical scar. Material and Method: With minimal skin incision and full sternotomy, 40 patients with congenital heart disease underwent open heart surgery from April 1997 through September 1997. Defects repaired included 30 ventricular septal defects, 4 atrial septal defects, and 1 sinus Valsalva aneurysm in 35 children(M:F=17: 18), and 3 Atrial septal defects, 1 ventricular septal defect, and 1 partial atrioventricular septal defect in 5 adults(M:F=1:4). Midline skin incision was performed from the second intercostal space to 1 or 2 cm above the xiphoid process. For full sternotomy, we used the ordinary sternal saw in sternal body, and a special saw in manubrium under the skin flap. During sternal retraction, surgical field was obtained by using two retractors in a crossed direction. Result: The proportion of the skin incision length to the sternal length was 63.1${\pm}$3.9%(5.2∼11cm, mean 7.3cm) in children, and 55.0${\pm}$3.5%(10∼13.5cm, mean 12cm) in adults. In every case, the aortic and venous cannulations could be done through the sternal incision without additional femoral cannulation. There was no hospital death, wound infection, skin necrosis, hematoma formation, or bleeding complication. Conclusion: We conclude that minimal skin incision with full sternotomy can be a safe and effective alternative method for the repair of congenital heart diseases in children and adults.

  • PDF

Effect of Grid Keratotomy on Indolent Corneal Ulcers in Dogs (개에서 만성 각막 상피 결손증 치료법으로서의 각막 격자 절개법)

  • Ahn, Jae-Sang;Kim, Se-Eun;Park, Young-Woo;Ahn, Jeong-Taek;Lee, Yesran;Lee, Eui-Ri;Seo, Kang-Moon;Jeong, Man-Bok
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.562-565
    • /
    • 2011
  • A total of 29 eyes (25 dogs: one eye, 2 dogs: both eyes) with indolent corneal ulcer were treated with grid keratotomy from January 2008 to March 2010. The corneal lesions were reevaluated at 7-14 day intervals. The treatments had been repeated until fluorescein dye was not retained on the cornea and the epithelium did not appear to be loosely attached to the stromal layer. The healing rate of the corneal ulcers was 86.2%. The mean healing time ($mean{\pm}SD$) was $15.92{\pm}9.19$ days, ranged from 7 to 39 days. The lesions of remaining 4 eyes had deteriorated or not improved for more than 6 weeks. In those cases, $3^{rd}$ eyelid flap following grid keratotomy was applied. After 2 weeks, all of the eyes healed by the treatment. The results in this study suggest that grid keratotomy could be an excellent choice as an initial treatment for superficial corneal ulcers in dogs. In the cases of recurrence or to promote healing of the lesions, however, $3^{rd}$ eyelid flap following grid keratotomy is recommended.

Correlation of Tectolineaments and Discontinuities in connection with Slope Failure (사면 붕괴와 관련 구조선 분석과 불연속면의 상관성 연구)

  • Baek, Yong;Koo, Ho-Bon;Kim, Seung-Hyun
    • The Journal of Engineering Geology
    • /
    • v.11 no.3
    • /
    • pp.303-313
    • /
    • 2001
  • A cut-slope near Guam-Ri Hwado-Eup Namyangju-Si Kyunggi-Do collapsed during a heavy rainfall over 400mm at 28th of August 2000. The cut-slope collapse reportedly developed mainly by block sliding along a set of discontinuities, although slope angle of the cut-slope was 40$^{\circ}$(1:1.2) that agrees with the road construction criteria. This study aims to analyze differences and correlations among several data-collecting methods limited to discontinuity analysis related with cut-slope collapse. This study started with analysing discontinuity surface characteristics, geology of the country rock and orientations of the discontinuities directly related with the collapse. Analysis of aerial photos around the study area provided regional lineament data, and discontinuity plane description and measurements were collected from core logging and Borehole Image Processing System (BIPS). Spearmans correlation ranking coefficient method was used to get correlation of discontinuity planes according to analysis methods. The result suggests that the correlation coefficient is ${\gamma}_s$ = 0.91 Plus, stability analysis of discontinuity plane orientation data using equal-area stereonet revealed that the study area is unstable to planar failure. This study suggests that the cut-slope angles currently applied should be shallower and that significant attention is required to orientation distribution of discontinuities existed in cut-slopes studies.

  • PDF