• Title/Summary/Keyword: 전환모드

Search Result 276, Processing Time 0.026 seconds

Mode Control Design of Dual Buck Converter Using Variable Frequency to Voltage Converter (주파수 전압 변환을 이용한 듀얼 모드 벅 변환기 모드 제어 설계)

  • Lee, Tae-Heon;Kim, Jong-Gu;So, Jin-Woo;Yoon, Kwang-Sub
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.4
    • /
    • pp.864-870
    • /
    • 2017
  • This paper describes a Dual Buck Converter with mode control using variable Frequency to Voltage for portable devices requiring wide load current. The inherent problems of PLL compensation and efficiency degradation in light load current that the conventional hysteretic buck converter has faced have been resolved by using the proposed Dual buck converter which include improved PFM Mode not to require compensation. The proposed mode controller can also improve the difficulty of detecting the load change of the mode controller, which is the main circuit of the conventional dual mode buck converter, and the slow mode switching speed. the proposed mode controller has mode switching time of at least 1.5us. The proposed DC-DC buck converter was implemented by using $0.18{\mu}m$ CMOS process and die size was $1.38mm{\times}1.37mm$. The post simulation results with inductor and capacitor including parasitic elements showed that the proposed circuit received the input of 2.7~3.3V and generated output of 1.2V with the output ripple voltage had the PFM mode of 65mV and 16mV at the fixed switching frequency of 2MHz in hysteretic mode under load currents of 1~500mA. The maximum efficiency of the proposed dual-mode buck converter is 95% at 80mA and is more than 85% efficient under load currents of 1~500mA.

A Mode Switching Protocol between RVOD and NVOD for Efficient VOD Services (효율적인 VOD 서비스를 위한 RVOD와 NVOD간의 전환 프로토콜)

  • Kim, Myoung-Hoon;Park, Ho-Hyun
    • The KIPS Transactions:PartA
    • /
    • v.15A no.4
    • /
    • pp.227-238
    • /
    • 2008
  • Recently, as network environment has broadened, the demands on VOD have been increased. The VOD services can be categorized into two types, RVOD and NVOD. Practical VOD services adopt one of them exclusively. Since a method using only one of RVOD and NVOD is not able to deal with frequently variable demand of clients, it leads to a result of overload on a server and a waste of server bandwidth. The efficiency of the network resource usage becomes lower. Hence this paper presents a study on the protocol for efficient VOD services. We propose a new protocol appliable for the existing VOD service algorithm, analyze its performance through simulation, and developed server/client systems applying the new protocol. We propose a mode switching protocol combined with protocols used in RVOD and NVOD. The proposed protocol is not able only to control both RVOD and NVOD but also to change the mode between RVOD and NVOD. As a result of using the proposed protocol to meet frequently variable demand, server bandwidth can be used efficiently. Especially, it can be applied to the existing VOD service algorithms. Therefore, we expect that the proposed protocol in this paper will be widely used in emerging VOD markets.

Exploring the change in achievement by the transition of the test mode from paper to computer: Focusing on the national assessment of educational achievement of high school mathematics (종이에서 컴퓨터로의 매체 전환에 따른 평가 결과의 변화 탐색: 고등학교 수학 국가수준 학업성취도 평가를 중심으로)

  • Jung, Hye-Yun;Song, Chang-Geun;Kim, Young-Jun;Lee, Kyeong-Hwa
    • The Mathematical Education
    • /
    • v.61 no.4
    • /
    • pp.597-612
    • /
    • 2022
  • Recently, large-scale mathematics assessments are shifting from traditional paper-based tests to computer-based tests, nationally and internationally. This study explored the mode effect (the difference in student achievement by the change of test mode) according to the types of test items, the technological function reflected in the items, the characteristics of students' computer use, and the computer-based test environment. To this end, we analyzed the results of the 2020 national assessment of educational achievement of high school mathematics conducted on a paper and computer basis. As a result, firstly, the mode effect induced by the mode transition was generally insignificant, but the mode effect was larger in the extended response type than other types. Secondly, there were differences in the mode effect according to the transition to test with computer mode where innovative items were added. Thirdly, the difference between mode effects was statistically significant according to the student's sense of efficacy in computer use. The results of this study suggest that innovative items should be introduced deliberately according to the targeted content and competency in evaluation, and that assessment design and environment preparation need to be carefully developed so that nonessential abilities other than students' mathematical ability or incidental situation do not distort the assessment results.

Development of Switching System for Flight Control Law (비행제어법칙 전환시스템 개발)

  • Ahn, Jong-Min;Im, Sang-Soo;Kwon, Jong-Kwang;Choi, Sup;Lee, Yong-Pyo;Ko, Joon-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.7
    • /
    • pp.712-718
    • /
    • 2008
  • This paper deals with a development of flight control law switching system which can be used for flight test of the research control law by switching control law during flight. Through this research program, fader logic and integrator stabilization design has been introduced to minimize the transient response of aircraft caused by flight control law switching and to prevent the divergence of the integrator included in the control law in standby mode. MIL-STD-1553B communication was applied to transfer the data between the two control laws. This paper introduce the control law switching system architecture and major design concept and include the system verification and validation result performed on the flying quality simulator of the advanced trainer.

A Combined Polling and Random Access Technique for Enhanced Anti-collision Performance in RFID Systems (폴링과 랜덤접속모드을 통합한 RFID 충돌방지 프로토콜)

  • Baeck, Ki-Kyung;Shin, Woo-Jin;Kim, Jeong-Geun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2007.05a
    • /
    • pp.875-876
    • /
    • 2007
  • 본 논문에서는 지능적으로 폴링과 랜덤접속모드를 사용하는 RFID 충돌방지 기법을 제안하고자 한다. 본 논문에서 제안하고자 하는 충돌방지 알고리즘은 태그의 교체율이 크지 않을 경우, 먼저 이전 인식과정에서 성공적으로 식별한 태그들에 대한 고유정보를 기억한 뒤 다음 인식 세션에서 그 고유 정보를 활용하여 출석을 부르는 것처럼 경쟁 없이 태그들을 호출하여 빠르게 식별한다. 이전 세션(session)에 비하여 많은 수의 태그가 교체되었으면 인식률이 저하될 수 있다. 이 경우에는 랜덤 접속모드로 전환하여 나머지 태그들을 읽어 낸다. 본 논문에서 제안하는 것처럼 인식이력을 활용한 모드와 랜덤 접속 모드를 적절히 조합하여 운용하면 태그 인식 시간을 단축할 수 있으며, 특히, 주기적으로 개체의 존재 유무를 확인하는 응용의 경우에 우수한 성능 향상을 얻을 수 있다.

  • PDF

Performance Evaluation of Dual Mode Packet Data Service in the IMT-2000 System (IMT-2000에서 이중 모드 패킷 데이터 서비스의 성능 분석)

  • 반태원;이상민;조유제
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.9A
    • /
    • pp.1592-1600
    • /
    • 2001
  • 본 논문에서는 IMT-2000을 위한 이중 모드 패킷 전송 방식에 대한 성능을 분석하고, 동적 임계치 설정을 이용한 이중 모드 패킷 전송 방식을 제안한다. 먼저, 다양한 채널 환경과 트래픽 유형을 고려하여, 공용 채널과 전용채널 간의 모드 전환을 위한 임계치의 변화에 따른 성능의 변화를 고찰하였다. 성능 분석 결과, 채널 환경과 트래픽 형태에 따라서 스위칭 임계치 설정이 매우 중요하며, 성능에 큰 영향을 미치게 된다는 것을 알 수 있었다. 그리고, 이중 모드 방식에서 스위칭 임계치를 동적으로 설정하는 방식을 제안하고 시뮬레이션을 통해 성능을 분석하였다. 제안된 동적 임계치를 사용할 경우에 채널 상황이나 트래픽 특성 변화에 적응적으로 대처할 수 있어, 전반적으로 고정 임계치 방식보다 성능이 크게 개선됨을 알 수 있었다.

  • PDF

Level Conversion Scheme for Improving Performance of RAID 5 on Single Disk Failure (단일디스크 고장시 RAID 5의 성능개선을 위한 레벨 전환 기법)

  • Jeon, Sang-Hoon;Chung, Hyun-Sik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.4 no.2
    • /
    • pp.8-18
    • /
    • 1999
  • It is very important to recover data immediately at a single disk failure for critical applications such as multimedia storage systems. real-time systems and so on. As an efficient solution, this paper proposes that RAID level conversion scheme to improve the performance before a failed disk is replaced with a new disk. By using this scheme, it does not require an additional disk to recover data. Comparing with previous studies, this scheme is appropriate to low cost system that has not additional redundant device. The performance of proposed scheme is evaluated and analyzed with that of RAID level 5 for various requested sizes through the simulation. The results show that the performance of the proposed scheme is improved up to 20 percents compared with that of RAID level 5 at the failure mode and 80 percents at reconfigured mode.

  • PDF

Reactive Power P&O Anti-islanding Method of ESS with Critical Load (중요부하를 갖는 ESS의 무효전력 P&O 단독운전 검출 기법)

  • Park, Sung-Youl;Kwon, Min-Ho;Kang, Su-Han;Choi, Se-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.213-214
    • /
    • 2016
  • 중요부하를 갖는 ESS용 인버터는 정전 발생 시에도 부하에 안정적인 전원을 공급해야 한다. 이를 위하여 모드전환 시 과도상태를 최소화하면서 clearing time에도 부하에 안정적인 전압을 공급할 수 있는 간접전류제어 기법이 연구된 바 있다. 그러나 계통연계 시에도 전압을 제어해주기 때문에 단독운전 시 NDZ을 벗어나지 않아, 기존 알고리즘으로는 단독운전을 검출하기 어렵다는 문제가 있다. 본 논문에서는 모드 전환 시 과도상태를 최소화하면서 단독운전 검출 전에도 부하 전압을 안정하게 제어할 수 있는 간접전류제어 기반 인버터에서 NDZ이 없는 무효전력 P&O 단독운전 검출 기법을 제안한다.

  • PDF

Flow/Pressure/Power Control of Hydraulic Pump Utilizing Switching Control Mode (스위칭 제어 모드를 이용한 유압펌프의 유량/압력/동력 제어)

  • Jung, D.S.;Kim, H.E.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.4
    • /
    • pp.8-14
    • /
    • 2007
  • The electro-hydraulic pump is usually used in testing equipments which require one control function. But until now, it is not applied to industrial equipments which are exposed to severe working environment and require various control functions. This paper proposes a technique which controls continuously flow, pressure and power by utilizing switching control mode. Mathematical model is developed from the continuity equation for the pressurized control volume and the torque balance for the swash plate motion. To simplify the model we make the linear state equation by differentiating the nonlinear model. We analyze the stability and disturbance by using the state variable model. Finally, we review the control performances of flow, pressure and power by tests using PID controller.

  • PDF

Comparison of PLL Algorithms Suitable for the Seamless Transfer Control (무순단 절체 기능에 적합한 PLL 알고리즘 비교)

  • Kim, Kiryong;Lee, Jong-Pil;Kim, Tae-Jin;Yoo, Dong-Wook;Kim, Hee-Je
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.383-384
    • /
    • 2017
  • 분산 발전에 사용되는 PCS는 계통연계 운전 및 독립 운전을 할 수 있어야 한다. 운전 모드 전환 시 발생하는 과도 상태를 최소화하기 위해 무순단 절체 기능이 필요하다. 이 기능을 위해서 계통 이상 유무에 대한 검출이 빠르게 이루어져야하기 때문에 PLL 알고리즘이 중요한 역할을 한다. 본 논문에서는 운전 모드 전환 시 무순단 절체 관점에서 PLL 알고리즘들을 시뮬레이션을 통해 비교하고 이를 바탕으로 적절한 PLL 알고리즘에 대해 고찰한다.

  • PDF