• Title/Summary/Keyword: 전하중

Search Result 421, Processing Time 0.038 seconds

Frequency and Pattern of Partial Thickness Rotator Cuff Tear in SLAP Lesions (SLAP 병변에서 회전근 개 부분층 파열의 빈도와 양상)

  • Cho, Duck-Yun;Yoon, Hyung-Ku;Kim, Hyoung-Jun;Rhee, Seung-Young;Kim, Jae-Hwa
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.119-123
    • /
    • 2004
  • Purpose: The purpose of this study is to check the range of motion of shoulder and inverstigate the frequencies and patterns of partial thickness rotator cuff tear in SLAP lesions. Materials and Methods: Forty-six patients, forty-seven cases who had SLAP lesions at shoulder arthroscopy were analyzed spectively using the medical records, intra-operative arthroscopic photo & video for SLAP lesions and rotator cuff articular side partial tear. Under the interscalene anesthesia, the range of notion of foreward elevation, internal rotation and external rotation was measured on fixed scapula and 90 degree abduction of the shoulder. Results: The rang of Motion are 150 degree on foreward elevation, 65.5 degree on external rotation, 61.7 degree on internal rotation. By Snyder's classification, type ll SLAP lesion is noted in 24 cases (five cases in type 1, one case in type IV). Rotator cuff articular side partial tear is noted in 24 cases ( one case in type I, 22 cases in type II, one case in type IV SLAP). All the rotator cuff articular side partial thickness tear were located in the anterior part of the supraspinatus. Conclusion: The rotator cuff partial thickness tear is mostly noted on the articular side and frequently found in the relatively more unstable type of SLAP lesions. So we consider that SLAP lesion may be a one of the causes for partial tear of the rotator cuff articular side.

  • PDF

Clinical Significance of Reverse Redistribution on Tc-99m MIBI and T1-201 Myocardial Perfusion SPECT Images (Tc-99m MIBI와 T1-201 심근 SPECT에서 역재분포의 임상적 의의)

  • Song, Ho-Cheon;Bom, Hee-Seung;Kim, Ji-Yeul;Jeong, Myung-Ho;Gill, Kwang-Chae;Park, Joo-Hyung;Cho, Jeong-Gwan;Park, Jong-Choon;Kang, Jung-Chaee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.95-103
    • /
    • 1996
  • Reverse redistribution(RRD) refers to a perfusion defect that develops or becomes more evident on rest imaging compared with the stress imaging. This phenomenon was not uncommonly noted on myocardial perfusion single photon emission computed tomography (SPECT). However, the clinical significance and pathophysiological mechanism of RRD were unclear. The aim of this study was to evaluate the incidence and clinical significance of RRD on either dipyridamole T1-201 or Tc-99m MIBI myocardial perfusion SPECT. RRD was defined as ${\geq}10%$ decrease in relative T1-201 and Tc-99m MIBI uptakes on rest images compared to the stress images or as an appearance of new perfusion defects on rest images. It was observed in both T1-201 (44/463, 9.5%) and Tc-99m MIBI (124/999, 12.4%) myocardial SPECTs similarly, with an overall incidence of 11.5%(168/1462). Many apparent)y unrelated disease groups showed the finding: post-revascularization(53.9%), coronary artery disease(24.6%), myocardial infarction(12.3%), and those with normal coro-nary arteries (9.2%). Clinical and angiographic characteristics of 65 consecutive patients who underwent coronary arteriography in 168 patients who had RRD on myocardial perfusion SPECT were reviewed. Tc-99m MIBI was used in 44 patients, and T1-201 was used in 21 patients. Of the 81 myocardial segments analyzed which showed RRD, 32 segments(39.5%) were in septum, 24(29.5%) in inferior wallL, 12(14.8%) in anterior wall, 7(8.7%) in apex and 6(7.4%) in lateral wall. There was no clear association between RRD and coronary arterial stenosis or Presence of collateral circulations. Ventriculographical wall motion was evaluated in 27 regions with RRD; it was normal in 12 regions, hypokinetic in 12 regions and dyskinetic in 3 regions. In 14 of 21 patients who showed RRD on T1-201 myocardial SPECT, T1-201 reinjection was performed immediately after the 3-4 hour redistribution studies. Ten of 14 (71.4%) showed enhanced T1-201 activity(${\geq}10%$ increased) after reinjection. We conclude that RRD is not related to mode of stress or radiopharmaceuticals. RRD might represent many inhomogeneous pathophysiological processes.

  • PDF

Performance Evaluation of Component Detectors of Double-scattering Compton Camera (이중 산란형 컴프턴 카메라 구성 검출기 성능 평가)

  • Seo, Hee;Park, Jin-Hyung;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.69-76
    • /
    • 2010
  • Prototype double-scattering Compton camera, which consists of three gamma-ray detectors, that is, two double-sided silicon strip detectors (DSSDs) as scatterer detectors and a NaI(Tl) scintillation detector as an absorber detector, could provide high imaging resolution with a compact system. In the present study, the energy resolution and the timing resolution of component detectors were measured, and the parameters affecting the energy resolution of the DSSD were examined in terms of equivalent noise charge (ENC). The energy resolutions of the DSSD-1 and DSSD-2 were, in average, $25.2keV{\pm}0.8keV$ FWHM and $31.8keV{\pm}4.6keV$ FWHM at the 59.5 keV peak of $^{241}Am$, respectively. The timing resolutions of the DSSD and NaI(Tl) scintillation detector were 57.25 ns FWHM and 7.98 ns FWHM, respectively. In addition, the Compton image was obtained for a point-like $^{137}Cs$ gamma source with double-scattering Compton camera. From the present experiment, the imaging resolution of 8.4 mm FWHM (angular resolution of $8.1^{\circ}$ FWHM), and the imaging sensitivity of $1.5{\times}10^{-7}$ (intrinsic efficiency of $1.9{\times}10^{-6}$) were obtained.

The electrical properties study with specific of phase transition of Lead Monoxide by PIB(Particle In Binder) (PIB(Particle In Binder) 방법으로 제조된 산화납의 특이상전이에 따른 전기적 특성 평가)

  • Kim, Sung-Hyun;Kim, Young-Bin;Jung, Suk-Hee;Kim, Min-Woo;Oh, Kyung-Min;Park, Ji-Gun
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.3
    • /
    • pp.19-25
    • /
    • 2008
  • Commercial analog x-ray detectors based on film cassettes have been showing problems such as with image storage and image transmission. Recently direct conversion material, photoconductor whit flat panel have been researched which generate the electron hole-pair (EHP). In this paper, we researched the electrical properties of the PbO and Lead(II) oxide PbO. film which fabricated by Particle-In-Binder(PIB) method. We compared tetragonal ${\alpha}$-PbO with orthorhombic ${\beta}$-PbO physical property. Tetragonal material was more than orthorhombic material in other paper. The solution was Poly Vinyl Butyral(PVB) in the PIB. We discussed about the sample of x-ray sensitivity, leakage current, Signal to Noise Rate and investigated SEM for the physical property of sample. We need to think more research ${\alpha}$-PbO material fabrication.

  • PDF

Chitosan Derivatives for Target of Specific Tissue in the Body (생체 내 특정 조직의 표적을 위한 키토산 유도체)

  • Jang, Mi-Kyeong;Nah, Jae-Woon
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.593-602
    • /
    • 2010
  • Chitosan as a natural polymer has superior physicochemical properties such as biocompatibility, biodegradability and nontoxicity, but application of chitosan for therapy of cancer and gene related-disease has been limited by poor solubility in aqueous solution. Therefore, low molecular weight water-soluble chitosan (LMWSC) with high reactivity and strong positive charge can be applied as a delivery system having function to carry in the specific tissue the bioactive material like poor solubility drug, or therapeutic gene and developed as a therapeutic system having good therapeutic efficiency. The most important factor for therapy of various diseases is to reveal the antigen or receptor expressed in specific lesion tissue and the antibody and ligand which can bind with antigen is to introduce at the biomaterials for enhancement the therapeutic efficiency. The studies for cationic synthetic polymer as drug or gene delivery have been actively performed, but it has many problems such as toxicity in the body, therapeutic efficiency. From this point of view, this article demonstrated the introduction of functional groups to target the specific tissue and therapeutic strategy using the modification of LMWSC with free-amine group. The development of these delivery system will provide a positive vision for cancer therapy.

Studies on the Michael Addition Reaction between Secondary Amino Groups on the Silica Surface with Poly(ethylene glycol) Diacrylates (실리카 나노입자 표면에 결합된 2차 아미노기와 Poly(ethylene glycol) Diacrylate의 마이클 부가반응에 대한 연구)

  • Jeon, Ha Na;Ha, KiRyong
    • Polymer(Korea)
    • /
    • v.36 no.6
    • /
    • pp.822-830
    • /
    • 2012
  • We used dipodal type bis[3-(trimethoxysilyl)propyl]amine (BTMA) silane coupling agent to modify silica nanoparticles to introduce secondary amino groups on the silica surface. These N-H groups were reacted with three different molecular weights (M.W. = 258, 575, and 700) of poly(ethylene glycol) diacrylates to introduce different attached layer thicknesses on the silica surface by Michael addition reaction. After Michael addition reaction, we used several analytical techniques such as fourier transform infrared spectroscopy (FTIR), elemental analysis (EA) and solid state $^{13}C$ cross-polarization magic angle spinning (CP/MAS) nuclear magnetic resonance spectroscopy to characterize introduced structures. We found almost complete Michael addition reaction of both two acrylate groups of PDGDA with N-H groups of BTMA modified silica to form ${\beta}$-amino acid esters. Between equimolar ratio of pure BTMA and pure PEGDA reaction, only one acrylate group of two acrylate groups of PEGDA reacted with N-H groups of pure BTMA to form ${\beta}$-amino acid ester and the other remaining acrylate group can be used to form a polymer later.

Ankle Arthroscopy for Occult Injuries in the Acute Ankle Fracture (급성 족 관절 골절에서 잠재 손상에 대한 족 관절경)

  • Choi Chong-Hyuk;Yang Kyu-Hyun;Park Seong-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.124-130
    • /
    • 2001
  • Purpose : To identify occult intra-articular pathologies in the acute ankle fracture using arthroscopy and to investigate the factors to predict its possibility of occult injuries that could be occurred. Materials and Methods : This prospective study included fifty patients who got operation for the ankle fractures. Ankle arthroscopy was performed to document the type and anatomical location of occult lesion. We investigated the correlation between incidence of occult injuries and specific fracture type. Results : Of fifty ankles, 37 ankles had occult lesion. Twenty five loose bodies including displaced fragments were found and various cartilage lesions were found in 31 ankles. Tibial avulsion fragment by anterior inferior tibiofibular ligament was occurred in 6 cases. There was no correlation between the incidence of occult lesion and various factors including age, sex, injury mechanism and fracture type(p>0.05). Conclusion : The ankle arthroscopy had an effective role for the detection and treatment of occult injuries and it was difficult to predict the occurrence or associated accurately in all of th ankle fractures.

  • PDF

EIS monitoring on corroded reinforcing steel in cement mortar after calcium electro-deposition treatment (칼슘 전착처리 후, 시멘트 모르타르 속 철근의 부식속도에 대한 EIS 모니터링)

  • Kim, Je-Kyoung;Kee, Seong-Hoon;Yee, Jurng-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.1-8
    • /
    • 2019
  • The primary purposes of this study are to understand a fundamental effects of electro-deposition on reinforcing steel in saturated Ca(OH)2 electrolyte, and evaluate the corrosion rates of rebars under cyclic 3wt.%NaCl immersion and dry corrosion environment. The three cement mortar specimens with cover thickness 5, 10 and 30mm, were prepared in the experiment. To monitor the corrosion rates of rebars in mortar, the three cement mortar specimens were exposed to 110 wet-drying cycles(8-hour-immersion in 3wt.%NaCl and 16-hour-drying in a room temperature) in the laboratory. During the wet-dry cycles, the polarization resistance, Rp, and solution resistance, Rs, were continuously measured. The instantaneous corrosion rates of rebars on the effect of electro-depositing with sat. Ca(OH)2 electrolyte were estimated from obtained R-1p and degrees of wetness were estimated from Rs values. From the experimental results, the corrosion rates of rebars were greatly accelerated by wet/dry cycles. During the mortars exposed to drying condition, the large increases in the corrosion rates were showed at all rebar surfaces in three mortar specimen, attributed from the accelerated reduction rates of dissolved oxygen in drying process. However, the corrosion rates on rebar surface electrochemically deposited with sat. Ca(OH)2 electrolyte showed the clear decreases, caused by calcium deposits in the porous rust layer.

SEMI-LONGITUDINAL STUDY OF GROWTH AND DEVELOPMENT OF CRANIO-FACIAL SOFT TISSUE OF CHILDREN AGED FROM 3 TO 11 (3-11세 아동의 두개 및 연조직의 성장변화에 관한 준종단적 연구)

  • Park, Young-chel;Choy, Kwang-chul;Han, Hee-kyung
    • The korean journal of orthodontics
    • /
    • v.27 no.6 s.65
    • /
    • pp.891-904
    • /
    • 1997
  • Today's orthodontic treatment goals lie in functional esthetics, and the importance of the latter is increasing gradually in trend. Considering such, study on growth and development of soft as well as hard tissues becomes inevitable. Early studies emphasize mainly on skeletal analysis using cephalometric data. However, more recent studies report that maxillofacial soft tissue, which plays a critical role in determining facial esthetics, is influenced by underlying hard tissue, and yet close relationship between them was not noticed. Cephalometric x-rays were taken of 137 Korean boys and 106 girls with no systemic disease, fair developmental status and normal occlusion for two consecutive years; afterwards, soft tissue analysis, which was divided into four parts, facial form lip position & posture, nose, and thickness, was done to correlate them with general growth.

  • PDF

Effects of Fe Substitution on Lithium Incorporation into Muscovite (백운모 내 리튬 함유에 대한 Fe 치환의 영향)

  • Chae, Jin-Ung;Kwon, Kideok D.
    • Journal of the Mineralogical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.127-133
    • /
    • 2015
  • Li-bearing muscovite is commonly found along with trioctahedral lepidolite in granitic pegmatites. Structurally, $Li^+$ ions can replace $K^+$ ions in the interlayer (Int) of muscovite or incorporate into vacancies of the dioctahedral sheet (Sub). However, detailed mechanism of the lithium incorporation into muscovite is challenging to investigate using experimental techniques alone. In the current study, density functional theory (DFT) has been applied to examine the crystal structure and energy variation when $Li^+$ resides in the interlayer or the octahedral sheet. Depending on the position of $Li^+$ (i.e., Int vs. Sub), DFT showed significant differences in the mica's structures such as lattice parameters, sheet thickness, interlayer separation, and OH angles with respect to the ab plane. DFT further showed that, in pure muscovite, $Li^+$ has a lower energy when it is located in Int than Sub. By contrast, in the case of $Fe^{2+}$ substitution into the octahedral sheet, $Li^+$ has a lower energy in Sub than in Int. These results imply that $Li^+$ incorporates into the Al octahedral sheets only when the octahedral sheets possess structural charges, suggesting cation substitution in the octahedral sheets plays an important role in the Li incorporation mechanism into muscovite. They can also explain the experimental observation about the positive relationship between $Fe^{2+}$ and $Li^+$ amounts in Li-bearing muscovite.