• Title/Summary/Keyword: 전치부

Search Result 948, Processing Time 0.027 seconds

A Study of the Comparison of Microleakage according to the Types of Cement on the Cast Post and Core (주조 포스트코아에서 시멘트 종류가 미세누출에 미치는 영향)

  • Nam, Ki-Young;Lee, Cheong-Hee;Cho, Kwang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2000
  • The purpose of this study was to compare the microleakage at the interface of cast post and tooth according to the type of cement. Forty anterior teeth with single root were used. The teeth were cut 2 mm coronal from the cementoeamel junction and chamfer finish line was made on 1 mm coronal from the cementoeamel junction. After the routine endodontic treatment, post space was prepared using #5.5 Parapost drill to a depth of 7 mm. After the pick up impression, core building was made to 3 mm of clinical crown with burnout wax, then post and core was cast with nonprecious metal. The teeth were divided into four groups of ten each. In Group I, post and core were cemented with Fleck's(Zinc phosphate cement) In Group II, post and core were cemented with Fuji I(Glass ionomer cement) In Group III, post and core were cemented with Superbond C & B(Composite resin cement) In Group IV, post and core were cemented with Panavia 21(Composite resin cement) All cemented teeth were stored in normal saline at $37^{\circ}C$ for 7 days and thermocycled from $5^{\circ}C$ to $55^{\circ}C$ for 500 cycles with a dwell time of 30 seconds. After thermocycling, teeth were immersed in 1% Basic fuchsin dye for 48 hours. All 40 teeth were then embedded in the epoxy resin and cut buccolingually with a cutting instrument. The degree of penetration of dye at interface was graded on a scale of 0 to 4 using a stereomicroscope at 25 to 40 times magnification. Through the findings of this study, the following conclusion were obtained. 1. All the groups showed the microleakage at the interface of cast post core and tooth. 2. Group I showed the highest microleakage score among the groups with a significant difference(p<0.05). 3. Group II showed higher microleakage score than Group III and Group IV with a significant difference(p<0.05). 4. Group IV showed the lowest microleakage score but there were no significant difference with Group III(p>0.05).

  • PDF

A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides (광중합형 복합레진과 shade guide의 색차에 관한 연구)

  • Lim, Kyung-Min;Lee, Min-Ho;Song, Kwang-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.13-22
    • /
    • 2009
  • The composite resin, due to its esthetic quality, is considered the material of choice for restoration of anterior teeth. To get a satisfactory result in the composite resin restorations, it is necessary to choose right shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guides or shade guides that are provided by their company, but color differences among them might be expected even using the same shade in various materials. This study is to measure color differences between various light-cured composite resins and shade guides and to provide the clinicians with information which may aid in improved color match of esthetic restoration. Four kinds of light-cured composite resins (Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), Esthet X (E X)) and shade guides with A2 and A3 shade were used. Three specimens of each material and one specimen of each shade guide were made. Each composite resin was filled into the Teflon mold (1.35 mm depth, 8 mm diameter), followed by compression, polymerization and polishing with wet sandpaper. Shade guides were grinded with polishing stones and rubber points to a thickness of approximately 1.35 mm. Color characteristics were performed with a spectrophotometer(color i5, GretagMacbeth, USA). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E^*ab$) between composite resins and shade guides. CIE standard D65 was used as the light source. The results were as follows : 1. Among the $L^*$, $a^*$, $b^*$ values of most of 4 kinds of composite resin specimens which are produced by same shade, there were significant differences(p<0.05). 2. Among all 4 kinds of composite resin specimens which are produced by same shade, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 3. Between most of composite resin specimens investigated and their corresponding shade guides, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 4. In the clinical environment, it is recommended that custom shade guides be made from resin material itself for better color matching. Shade guides supplied by manufacturers or Vita Lumin shade guide may not provide clinicians a accurate standard in matching color of composite resins, and there are perceptible color differences in most of products. Therefore, it is recommended that custom shade guides be made from resin material itself and used for better color matching.

A comparison study of the effects of hypertrophied adenoid tissue on jaws morphology (정상 교합자와 adenoid가 과식증된 부정교합자의 악골 형태의 비교)

  • Yu, Hyung-Seog;Park, Sun-Hyung
    • The korean journal of orthodontics
    • /
    • v.32 no.1 s.90
    • /
    • pp.19-31
    • /
    • 2002
  • To investigate the association between the hypertrophy of adenoid and jaw morphology during growth, this paper was based on children patients with experimental adenoids (male-15 subjects at each bone age group, female-15 subjects at each bone group) and comparing them to data taken from a control group (male-15 subjects at each bone age group, female-15 subjects at each bone group) with normal respiratory function. The comparisons between the groups were done at each growth stage using cervical vertebrae maturation index(CVMI) of Hassel. The obtained results were as follows : 1. The differences in craniofacial morphology between experimental group and control group were appeared from CVMI 3 and CVMI 4 (aroud adolescent period) in males, and from CVMI 1 in females. 2. The mandibular position of experimental group was more inferior than control group. The difference appeared at adolescent period(male : at CVMI 4, female : at CVMI 5). 3. Experimental group had greater anterior facial height than control group. This difference seemed a relation with lower anterior facial height. The difference appears at CVMI 3(11.94 ${\pm}$ 1.38 years old, at adolescent period) in male and at CVMI 1 in female. 4. The adenoid size of control male group was increased until CVMI 2(10.58 ${\pm}$ 1.07 years old, just before adolescent growth peak) and then decreased, but in female the adenoid size was decreased from CVMI 1(6.92 ${\pm}$ 0.53 years old).

Age Estimation by Modified Johanson Method (Johanson 방법을 응용한 연령추정)

  • Lee, Won-Joon;Kim, Byung-Gook;Kim, Jae-Hyung;Lim, Hoi-Soon;Lee, Guem-Sug;Choi, Hong-Ran
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.2
    • /
    • pp.201-214
    • /
    • 2005
  • Age estimation is fundamental and important in personal identification with forensic medicine and dentistry. Recently, a lot of studies using various part of the body have been done for age estimation. Age estimation with teeth is the most significant method comparing ones with other part of the body. Gustafson method and Johanson method using postmortem teeth have been authorized in accuracy and systemization and used domestically and internationally. The verification of the accuracy in above methods had been tried many times but it is still rare in Korea. Fifty-nine teeth(incisors, canine, premolars and molars) which were extracted due to periodontal diseases or orthodontic problem were collected. Present study is to 1) compare the accuracy of estimated age in applying Gustafson method and Johanson method to the teeth in Korea, 2) compare and analyze the correlation with results using Gustafson method and Johanson method by age, gender, maxilla - mandible and anterior - premolar - molar. Teeth were embedded in resin and sliced and then examined each one using Gustafson method and Johanson method. The results are as follows: 1. Actual age was a significant difference in estimated age by Johanson method. Actual age was a significant correlation in estimated age by Gustafson method and modified Johanson method. Modified Johanson method was more significant than Gustafson method. 2. In estimated age by Gustafson method, Johanson method and modified Johanson method, there was no significance with actual age by location and gender. 3. In estimated age by Gustafson method, Johanson method and modified Johanson method, there was significance with actual age by age group. Finally, Gustafson method and Johanson method can be used in Korea. To make more accurate verification, however, it needs more specimen and postmortem teeth. Johanson equation proposed by himself has to be developed by further studies.

Distortion of tooth axes on panoramic radiographs taken at various head positions (두부 위치 변화에 따른 파노라마 방사선사진상의 치축각도의 왜곡)

  • Jeon, Hyun-Sang;Choi, Gab-Lim;Lim, Sung-Hoon;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.240-251
    • /
    • 2008
  • Objective: The purpose of this study was to evaluate the effect of head position changes on the root parallelism between adjacent teeth on panoramic radiographs. Methods: A model with normal occlusion was constructed in the SolidWorks program, then RP (rapid protyping) model was fabricated. The model was repeatedly imaged and repositioned five times at each of the following nine positions: ideal head position, $5^{\circ}$ up, $10^{\circ}$ up, $5^{\circ}$ down, $10^{\circ}$ down, $5^{\circ}$, right, $10^{\circ}$, up, and $5^{\circ}$ right rotation, $10^{\circ}$ right rotation. Panoramic radiographs were taken by Planmeca ProMax and the angle between the long axes of adjacent teeth was directly measured in the monitor. Results: Axes of adjacent teeth tended to converge toward the occlusal plane when the head tilted up and converged in the opposite direction to the occlusal plane when the head tilted down. Anterior teeth showed the most notable differences. When one side of the head tilted up $5^{\circ}$ and $10^{\circ}$ along the anteroposterior axis (Y axis), tooth axes of the same side tended to converge toward the occlusal plane and tooth axes of the opposite side tended to converge in the opposite direction to the occlusal plane. When the head rotated to one side along the vertical axis (Z axis), the canine and lateral incisor of the same side converged in the opposite direction to the occlusal plane and the canine and lateral incisor of the other side converged toward the occlusal plane. Conclusions: When assessing the root parallelism on panoramic radiographs, the occlusal plane cant (anteroposterior or lateral) or asymmetry of the dental arch should be considered because these can cause distortion of tooth axes on panoramic radiographs.

Comparative study of surface roughness between several finishing and polishing procedures on ormocer-based composite resin and nanohybrid composite resin (복합 레진에서 마무리 방법에 따른 표면 거칠기 비교)

  • Jeong, Suk-In;Oh, Nam-Sik;Lee, Myung-Hyeon;Lee, En-Jung;Cho, Jung-Hyeon;Ji, Sung-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.105-115
    • /
    • 2008
  • Statement of problem: Proper finishing and polishing enhance both the esthetics and the longevity of restored teeth. Blade finishing technique would be suited for smoothing and finishing. Evaluation of this technique are necessary. Purpose: The purpose of this study was to evaluate the blade finishing and polishing procedures on the surface profile and roughness of ormocer-based composite resin and nanohybrid composite resin. Material and methods: The material included a ormocer-based composite resin ($Admira^{(R)}$ & $Admira^{(R)}$ Flow); a nanohybrid composite resin ($Grandio^{(R)}$ & $Grandio^{(R)}$ Flow). One hundred forty specimens of each group were prepared using a mylar strip and randomly divied into blade finishing and rubber polishing groups (n=10). The average surface roughness (Ra) in micrometers was measured and the surface profile was examined by scanning electron microscopy (SEM) (Magnification ${\times}$ 200). The data were analyzed by Mann-Whitney Test at 0.05 significance level. Conclusion: The results of this study indicated that the mylar strip produced the smoothest surface on all materials and among the finishing-polishing methods was not significanct difference (P>0.05). Ormocer-based flowable composite resin performedthe lowest variability in initial surface roughness among the tested materials.

EARLY DETECTION OF INITIAL DENTAL CARIES USING A $DIFOTI^{TM}$ (Digital Imaging Fiber-Optic Trans-illumination을 이용한 초기 법랑질 우식병소의 조기 진단)

  • Yeom, Hae-Woong;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.587-597
    • /
    • 2004
  • Over the past 20 years, great strides have been made in research regarding the mechanisms involved in the progression of carious lesions, but new equipment and research tools need to be developed to continue these advancements in caries research. Various methods have been applied to reduce the incidence of carious lesions, which have led to a significant decrease in the number of occlusal caries, but a concurrent increase in the proportion of proximal carious lesions. New diagnostic equipment has been developed to detect early stage carious lesions, and these have demonstrated excellent laboratory results and show promise in clinical applications. The research presented here examines the efficacy of the newly developed $DIFOTI^{TM}$ system in detecting proximal carious lesions compared to traditional intraoral exam and bitewing radiography, possible problems or deficiencies of using the system in clinic, possible improvements that can be made to the system, and the efficacy of detecting early, reversible carious lesions that can be remineralized by preventative fluoride applications. The subject pool consisted of 23 grammer school age patients just prior to entering the mixed dentition phase. Each patient was given a thorough oral examination, radiographic examination consisting of bitewing radiographs of the posterior teeth, and $DIFOTI^{TM}$ examination of the anterior and posterior teeth. Each examination was carried out two times by two examiners, and the data were statistically analyzed. The results are as follows: 1. The mean alpha value of reliability test of the visual oral examination was as follows; occlusal surface was 0.8470. mesial surface was 0.6430, distal surface was 0.5727. lingual surface was 0.2807 and distal surface was 0.2339. When the examination was limited to posterior teeth, the mean alpha value was as follows; occlusal surface was 0.8577, distal surface was 0.8211, lingual surface was 0.7728, buccal surface was 0.7152 and mesial surface was 0.6782. 2. The alpha value of reliability test of the radiographic analysis of carious lesions of the occlusal, mesial, and distal surfaces was 0.8500. 3. The alpha value of reliability test of the $DIFOTI^{TM}$ diagnostic analysis of carious lesions of the occlusal, buccal, lingual, mesial, and distal surfaces was determined to be 0.7917. 4. The $DIFOTI^{TM}$ diagnostic system was found to be the most accurate means of detecting occlusal, buccal, and lingual surface carious lesions (p<0.05), while mesial and distal proximal carious lesions were most accurately assessed using bitewing radiography (p<0.05).

  • PDF

Complication and Failure Analysis of Endodontically Treated Teeth Restored with Post and Cores (포스트로 수복한 근관 치료된 치아의 임상적 상태에 대한 평가)

  • Yun, Mi-Jung;Kim, Mu-Hyon;Jeong, Chang-Mo;Huh, Jung-Bo;Jeon, Yeong-Chan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.359-370
    • /
    • 2012
  • The endodontically treated tooth is generally restored with post and core, owing to the brittle and the loss of large amount of tooth structure. The purpose of this study was to evaluate the clinical status of fixed prostheses to improve the quality of dental care. In order to assess the clinical status of fixed prostheses, a total of 101 individuals (aged 30-89, 66 women and 35 men loaded with 125 fixed prostheses) who treated in the Department of Prosthodontics, Pusan National University Dental Hospital, between January 1990 to December 2005 were examined. The results of this study were as follows: 1. Length of service of fixed prostheses was $9.7{\pm}3.4$ years (mean), 11.1 years (median). 2. Age and sex of patient was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 3. Location of fixed prostheses was found to have statistically significant influence on longevity of fixed prostheses (P<.05). The longevity of fixed prostheses was low in anterio-posterior combination region (median:9.2 years). 4. Longevity of fixed prostheses made of base metal ceramic(median:12.0 years) and noble metal ceramic (median:11.3 years) is long (P<.05). 5. Number of units in fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 6. Condition of opposing dentition was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 7. Dental caries, periapical disease, tooth fracture were frequent complications. In 51.9% of the cases, abutment state after removing fixed prostheses was needed to be extracted.

The effectiveness of sealing technique on in-office bleaching (전문가 미백시 sealing technique의 효율성에 관한 연구)

  • Lee, Yoon;Kwon, So-Ran;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.463-471
    • /
    • 2008
  • This study investigated the clinical effectiveness and safety of sealed bleaching compared to conventional in-office bleaching using a randomized clinical trial of split arch design. Ten participants received a chairside bleaching treatment on the upper anterior teeth, and each side was randomly designated as sealed or control side. A mixture of Brite powder (PacDent, Walnut, USA), 3% hydrogen peroxide and carbamide peroxide (KoolWhite, PacDent, Walnut, USA) were used as bleaching agent. The control side was unwrapped and the experimental side was covered with a linear low density polyethylene (LLDPE) wrap for sealed bleaching. The bleaching gel was light activated for 1 hour. The tooth shades were evaluated before treatment, after treatment, and at one week check up by means of a visual shade (VS) assessment using a value oriented shade guide and a computer assisted shade assessment using a spectrophotometer (SP). The data were analyzed by paired t-test. In the control and sealed groups, the visual shade scores after bleaching treatment and at check up showed statistically significant difference from the preoperative shade scores (p<.05). The shade scores of the sealed group were significantly lighter than the control immediately after bleaching and at the check-up appointment (p<0.05). Compared to prebleaching status, the ${\Delta}E$ values at post bleaching condition were $4.35{\pm}1.38\;and\;5.08{\pm}1.34$ for the control and sealed groups, respectively. The ${\Delta}E$ values at check up were $3.73{\pm}1.95\;and\;4.38{\pm}2.08$ for the control and sealed groups. ${\Delta}E$ values were greater for the sealed group both after bleaching (p<.05) and at check up (p<.05). In conclusion, both ${\Delta}E$ and shade score changes were greater for the sealed bleaching group than the conventional bleaching group, effectively demonstrating the improvement of effectiveness through sealing.

Clinical Evaluation of Guided Bone Regeneration Using 3D-titanium Membrane and Advanced Platelet-Rich Fibrin on the Maxillary Anterior Area (상악 전치부 3D-티타늄 차폐막과 혈소판농축섬유소를 적용한 골유도재생술의 임상적 평가)

  • Lee, Na-Yeon;Goh, Mi-Seon;Jung, Yang-Hun;Lee, Jung-Jin;Seo, Jae-Min;Yun, Jeong-Ho
    • Implantology
    • /
    • v.22 no.4
    • /
    • pp.242-254
    • /
    • 2018
  • The aim of the current study was to evaluate the results of horizontal guided bone regeneration (GBR) with xenograf t (deproteinized bovine bone mineral, DBBM), allograf t (irradiated allogenic cancellous bone and marrow), titanium membrane, resorbable collagen membrane, and advanced platelet-rich fibrin (A-PRF) in the anterior maxilla. The titanium membrane was used in this study has a three-dimensional (3D) shape that can cover ridge defects. Case 1. A 32-year-old female patient presented with discomfort due to mobility and pus discharge on tooth #11. Three months after extracting tooth #11, diagnostic software (R2 GATE diagnostic software, Megagen, Daegu, Korea) was used to establish the treatment plan for implant placement. At the first stage of implant surgery, GBR for horizontal augmentation was performed with DBBM ($Bio-Oss^{(R)}$, Geistlich, Wolhusen, Switzerland), irradiated allogenic cancellous bone and marrow (ICB $cancellous^{(R)}$, Rocky Mountain Tissue Bank, Denver, USA), 3D-titanium membrane ($i-Gen^{(R)}$, Megagen, Daegu, Korea), resorbable collagen membrane (Collagen $membrane^{(R)}$, Genoss, Suwon, Korea), and A-PRF because there was approximately 4 mm labial dehiscence after implant placement. Five months after placing the implant, the second stage of implant surgery was performed, and healing abutment was connected after removal of the 3D-titanium membrane. Five months after the second stage of implant surgery was done, the final prosthesis was then delivered. Case 2. A 35-year-old female patient presented with discomfort due to pain and mobility of implant #21. Removal of implant #21 fixture was planned simultaneously with placement of the new implant fixture. At the first stage of implant surgery, GBR for horizontal augmentation was performed with DBBM ($Bio-Oss^{(R)}$), irradiated allogenic cancellous bone and marrow (ICB $cancellous^{(R)}$), 3D-titanium membrane ($i-Gen^{(R)}$), resorbable collagen membrane (Ossix $plus^{(R)}$, Datum, Telrad, Israel), and A-PRF because there was approximately 7 mm labial dehiscence after implant placement. At the second stage of implant surgery six months after implant placement, healing abutment was connected after removing the 3D-titanium membrane. Nine months after the second stage of implant surgery was done, the final prosthesis was then delivered. In these two clinical cases, wound healing of the operation sites was uneventful. All implants were clinically stable without inflammation or additional bone loss, and there was no discomfort to the patient. With the non-resorbable titanium membrane, the ability of bone formation in the space was stably maintained in three dimensions, and A-PRF might influence soft tissue healing. This limited study suggests that aesthetic results can be achieved with GBR using 3D-titanium membrane and A-PRF in the anterior maxilla. However, long-term follow-up evaluation should be performed.