• Title/Summary/Keyword: 전차선로

Search Result 249, Processing Time 0.036 seconds

High-speed power network for catenary abnormal voltage effect and analysis (고속선 전차선로 이상전압 발생의 영향과 분석)

  • Lee, Gi-Chun;Jeon, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1161-1162
    • /
    • 2007
  • In year 2004 korea runs high speed train KTX for the 5th time in the world. And now the traction power system is quite stabilized. But still a lot of work to develop and abnormal voltage problem is one of them. In this paper, by actual measuring we have collected the abnormal data on the high speed train sub-staion for more than 15 days. The collected data has been evaluated. In the near future collected data will be used planing a countermeasure.

  • PDF

Development of a Pulley-type Tensioning Device (도르래식 장력조정장치 개발)

  • Lee, Ki-Won;Cho, Yong-Hyeon;Park, Young
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.663-669
    • /
    • 2009
  • In the electrical railway, the increase of tensions in an overhead contact lines is essential to speed-up of train, because current collection quality largely depends on the ratio of a wave propagation speed to a train speed. For Kyungbu high-speed line, a pulley-type tensioning device is required to have a tension variation of maximum 3%. Therefore we developed a pulley-type tensioning device in order to meet tension variation requirement of the high-speed tensioning device. To verify the performance of the developed device, a performance test, overload test and failure test were carried out according to the factory test procedure of the Kyung-Bu High-speed line. Furthermore, we also performed reliability performance through not only a fatigue test in a factory, but also on-line verification test in Chungbuk line for over 1 year. These tests verified that the tensioning device had applicability to a main line.

북한철도 DC 전철설비 표준화를 위한 기초 사양 분석

  • Park, Yeong;Jo, Yong-Hyeon;Kim, Hyeong-Cheol;Jeong, Ho-Seong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.226-226
    • /
    • 2009
  • 남북한 간의 전철 전력 설비의 연계 혹은 개량은 다양한 문제점이 발생이 가능하고 각종 기준 및 레벨의 차이가 심각하다. 따라서, 북한의 전기설비의 개량을 위한 전철 전력설비의 노후도 진단기술, 전압안전성 평가, 상호연계를 위한 시뮬레이션, 안전기준 마련등 광범위한 분야의 실용적 접근이 필요하다. 본 논문에서는 남북 및 대륙철도의 실용주의적 접근을 위하여 인프라 분야인 전철 분야의 표준화 방향에 대하여 기술하였다. 이를 위하여 북한 전철 설비의 전압, 지지물, 브래키트, 급전선, 조가선, 전차선, 장력조정장치, 조가방식, 전차선높이, 가고를 각각 분석 하였다.

  • PDF

Electromagnetic Induction Voltage according to the Position of Telecommunication Line from the Power Feeding Plant of Electrified Railway System (전기철도의 급전소 위치 관계에 따른 통신선 전자유도 전압)

  • Lee, Sangmu;Choi, Munhwan;Cho, Pyung-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.689-692
    • /
    • 2015
  • That induced voltage by an electrified railway line is related with the position of telecommunication line between traction power feeding systems is practically varified by measurements in the real field. This experimented fact is conformed with the calculated simulation provided by the ITU-T Directives concerning the protection of telecommunication lines against harmful effects from electric power and electrified railway lines. Therefore it is needed to consider at what position a telecommunication line is parallelized with power feeding line of traction system when an induction phenomenon is evaluated or measurement is carried out besides the length of parallelization and the separate distance between power line and telecommunication line.

  • PDF

Development of a Measuring Method for Dynamic Contact Forces between a Pantograph and a Contact Wire (열차 집전장치와 전차선 사이의 동적 접촉력 측정방법 개발)

  • 조용현;최강윤
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.281-285
    • /
    • 2002
  • A new method of dynamic contact force measurement between a pantograph and a contact wire is proposed in this paper The method does not require design modification of an original pantograph in order to install sensors such as load cells. Contact forces can be expressed as the sum of vertical shear forces at the support points and inertial forces. Using specially-designed strain gage rosettes. vertical shear forces at the supported points can be measured without noise mixing and thermal effects. In order to obtain contact forces from shear forces, 3 inertial force compansation methods are proposed and compared in this paper. By validation process, the new proposed measurement method is verified to be applicable to the on-line current collection test.

  • PDF

Analysis for Catenary Voltage of The ATs-Fed AC Electric Railroad System (단권변압기 교류전기철도 급전시스템의 전차선 전압해석)

  • 정현수;이승혁;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.9
    • /
    • pp.493-499
    • /
    • 2003
  • This paper presents exact Autotransformers(ATs)-fed AC electric Railroad system modeling using constant current mode for locomotives. An AC electric railroad system is rapidly changing single-phase load, and at a feeding substation, 3-phase electric power is transferred to paired directional single-phase electric power. As the train moves along a section of line between two adjacent ATs. The proposed AC electric railroad system modeling method considers the line self-impedances and mutual-impedances. The constant current mode model objectives are to calculate the catenary and rail voltages with the loop equation. When there are more than one train in the AC electric railroad system, the principle of superposition applies and the only difference between the system analyses for one train. Filially, this paper shows the general equation of an AC electric railroad system, and that equation has no relation with trains number, trains position, and feeding distance.

A Study on Double Converter for Urban Transit Power Supply (도시철도 전력공급용 더블컨버터에 관한 연구)

  • Jang, Choon-Seok;Kim, Sung-An;Kim, Hwan-Jin;Han, Gap-Jin;Cho, Yun-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.223-224
    • /
    • 2015
  • 도시철도에서 사용하는 전력공급 장치는 대부분 다이오드를 이용하여 전차선(DC)에 공급하고 있으며, 다이오드 특성상 단방향 전력공급이 가능하기 때문에 전동차의 회생제동으로 발생하는 회생 전력을 재사용 할 수 없는 단점을 가지고 있다. 따라서 본 논문에서는 전동차에서 발생하는 회생전력을 교류 모선으로 환원시켜주기 위하여 사이리스터를 이용한 양방향 더블컨버터를 제안한다. 더블컨버터의 제어 목적은 전차선의 부하에 따라 전압을 일정하게 유지시키면서 부하 조건에 따라 안정적인 모드 전환을 하는 것이다. 이를 위하여 더블컨버터의 병렬로 운전을 통하여 순차적인 모드 전환을 위한 알고리즘을 더블컨버터 시뮬레이션을 적용하여 검증하였다.

  • PDF