• Title/Summary/Keyword: 전차선로

Search Result 249, Processing Time 0.029 seconds

A study on the safety about Contact wire uplift of a metro-railroad bridge section (도시철도 교량구간의 전차선 압상량에 대한 안전성 연구)

  • Jang, Woo-Jean;Cho, Yong-Hyeon;Lee, Ki-Won;So, Sun-Young;Park, Jong-Hak;Lee, Bong-Jae
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.821-831
    • /
    • 2006
  • There are 5 railway bridges in a Seoul metro network; Jamsil, Dangsan(line 2), Dongho(line 3), Dongjak(line 4) and Chungdam(line 7). Because there are strong wind and vibration in the bridges, uplift of a contact wire caused by pantographs in the bridge section is higher than in a normal section. If the uplift at the support point exceed 10 cm, an interference between pantographs and catenary system happens. Estimated maximum uplift is obtained by applying safety factor 2 to the simulation results. The application of the safety factor is needed for taking into account of the effect of the wind, etc. Previously, we can not check whether or not the safety factor is proper. Recently, we can measure the uplift during the train operation, as a telemetry system which can measure dynamic behavior of the contact wire has been developed. The aim of this research is to review how proper the safety factor related to the uplift is, based on the measurement. We performed simulations and experiments for the uplift at the Jamsil railway bridge. The simulations were performed for the every kind of the train passing the Jamsil bridge. In order to compare the analysis results with the measurement results, we measured the uplifts at the support when the trains passed the measuring point. Finally, we proposed adequate safety factor with the uplift for the bridge section.

  • PDF

Analysis of Effect of Pantograph Cover on the Current Collection Quality of High Speed Train using Real Train Experiment (실차시험을 통한 팬터그래프 커버가 고속열차의 집전성능에 미치는 영향에 대한 분석)

  • Oh, Hyuck Keun;Kim, Seogwon;Cho, Yong-hyun;Kwak, Minho;Kwon, Sam Young
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.409-416
    • /
    • 2016
  • The contact force characteristic between the pantograph and the catenary wire represents the current collection quality of trains; it should be precisely controlled under international standard. Recently, a noise reduction cover has been installed around the pantograph of high speed trains. However, little study on the contact force by the pantograph cover has been conducted. In this study, the impact on the current collection performance of the pantograph cover was analyzed by dynamic contact force measurement using a next generation high speed train (HEMU-430X). As a result, it was confirmed that the attachment of a pantograph cover could lower the mean contact force by approximately 50N at 300km/h. In addition, the pure difference of the average contact force by the presence of pantograph cover, except for the static pressure, was measured and found to be up to 110N at 300km/h. It was also found that the standard deviation of the contact force of 3~5N could be changed by use of a pantograph cover.

Development of 50W High Quality Factor Printed Circuit Board Coils for a 6.78MHz, 60cm Air-gap Wireless Power Transfer System (6.78MHz, 거리 60cm, 50W급 무선 전력 전송 시스템용 High Quality Factor PCB 코일 개발)

  • Lee, Seung-Hwan;Yi, Kyung-Pyo
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.468-479
    • /
    • 2016
  • In order to supply power to online monitoring systems that are attached to high voltage catenary or overhead wires, a wireless power transfer system is required that is able to transmit power over the insulation gap. Such wireless power transfer systems have transmitter and receiver coils that have diameters of over 10cm. This paper focused on an investigation of the sources of loss in the coils when the coils are fabricated using printed circuit board technology. Using finite element simulation results, it has been shown that the dielectric loss in the substrate was the dominant source of the total loss. It has been demonstrated that the selection of a proper dielectric material was the most critical factor in reducing the loss. For further reduction of the loss, the distributed tuning capacitor method and the slotting of the inter-turn spaces have been proposed. For the evaluation of the proposed methods, four coils have been fabricated and their equivalent series resistances and quality factors were measured. Measured quality factors were greater than 300, which means that these devices will be helpful in achieving high coil-to-coil efficiency.

The Effectiveness due to fixed position change of fault protective wire on catenary system (전차선로에서 보호선 설치 위치변경에 따른 효과 검토)

  • Ryoo, Hyang-Bok;Ahn, Young-Hoon;Hyun, Chung-Il;Kang, Seung-Wook
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1456-1459
    • /
    • 2007
  • Protective equipments have a very important protection role in power accident on catenary line. These equipments are installed on electrical pole. The poles have complicated with many bands(moveable bracket, branch wire anchor, shield wire, etc). So we have improved bands and installed bands on pole to test technical condition. The Result has showed effectiveness due to fixed position change of fault protective wire and to improve band shape. For example, reduction of band made cost, simplification of installing, correct position of protective wire and shield wire.

  • PDF

Analysis of Feeder wire fault Scenario on AC Railway Feeding System considering Train Position (전차 위치를 고려한 교류 전기철도 급전계통의 급전선 고장 시나리오 해석)

  • Huh, Seunghoon;Cho, Gyujung;Ryu, Kyusang;Lee, Hundo;Kim, Chulhwan;Min, Myunghwan;An, Taepung;Kwon, Seongil
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.272-273
    • /
    • 2015
  • This paper analyze scenario of feeder wire fault that occurs in the AC feeding system considering train position. The fault location of AC feeding system is calculated by measuring impedance. However, in this way, estimation error can be occurred because of tie connection, boosting current, etc. Therefore, it's hard to find fault location, so that it is required to detailed circuit analysis according to fault location. We analyze the short circuit impedance values with respect to feeder wire fault according to a train position. In this paper, PSCAD is used for modeling and analysis of AC railway feeding system.

  • PDF

Study on tests on interfaces and connection of end fitting of composite insulators (복합 애자류의 수분침투시험평가기술에 대한 고찰)

  • Kim, Geun-yong
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1171-1172
    • /
    • 2015
  • 송전선이나 전기기기의 나선(裸線)부분을 절연하고 동시에 기계적으로 유지 또는 지지하기 위한 절연체와 이것과 일체로 조립된 금구류로 구성된 절연지지물인 애자는 전기적으로 충분한 절연내력을 가지게 하기 위하여 다수의 주름을 만들어 표면에 따른 거리를 크게 한다. 이는 표면이 습하였을 때, 염분이나 먼지 등이 부착하였을 때 절연내력이 저하되는 것을 방지하는 데 효과가 있다. 그리고 재질별(세라믹, 유리, 합성수지 등), 모양별(원판형, 원주형, 중공, 갓형 등), 용도별(전차 선로용, 발전소 또는 변전소용, 통신 선로용 등) 및 사용방법(현수용, 내장용, 인류용, 고정용 등)에 따라 다양하게 분류된다. 본 논문에서는 복합 애자류(composite insulators)의 여러 가지 성능평가 시험방법 중에서 복합 애자의 여러 계면과 연결 금구의 접속부(interfaces and connections of end fittings)에 대한 이상 유무를 확인하는 시험인 수분침투시험평가기술에 대해 고찰하였다.

  • PDF

A Study of Equipment Improvment method of the Expansion joint & Air Section in Rigid Trolley Bar System (AL T-Bar) (강체전차선방식(AL T-Bar)에서의 Expansion joint 및 Air Section 설비 개량방안 연구)

  • Yoo Jeung-Sang;Jang Woo Jin;Lee Byung-Song
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.523-528
    • /
    • 2003
  • AS City traffic means, the electric railway of the role is overwhelming with recognizing good merits of safety, no environment disruption and accurate destination time. Currently, Korea subway are running about 290km through eight subway lines. The latest constructed subway had been made by imperoved matherials which is going on improving. Therefore, we researched this project to keep up facilites easily, repress a leakge current and reduse install cost and repair time in changing facility at overhead Contact wire system because of arc by reforming construction plan about Expansion Joint and Air Section which is regarded as weak point when facilities are fixed and maintianed of Rigid Trolley bar System. as above we can contribute various part to making useful O.C.S(overhead contact wire system)

  • PDF

A Study on Determination for An Economic Life-cycle of the K-1 Tank (K-1 전차의 경제 수명 결정에 관한 연구)

  • 문형선;김충영
    • Journal of the military operations research society of Korea
    • /
    • v.23 no.1
    • /
    • pp.138-150
    • /
    • 1997
  • The life-cycle of the K-1 tank has been 10 years simply applying that of the U.S. M-1 tank. Therefore, this paper is focused on determination of an economic life-cycle for the K-1 tanks. The current operation cost is adjusted by interest rate and the depreciation cost is applied in this study for more reliable estimation of the life-cycle cost. The Equivalent Annual Method is utilized and then various regression techniques are applied for deriving an effective economic life-cycle. The economic life-cycle of the K-1 tank results in 13 years in this study. considering 95% confidence interval, the life cycle of the K-1 tank is between 10.5 years and 15.5 years.

  • PDF

A Study on the Comparison of the Rolling and Resistance Performance for the Stepped-Hull with attached a Stern-body by using Sea Model-Test (실 해상모형시험을 이용한 선미 보조동체 장착 Stepped hull 선형의 횡동요 및 저항특성 비교 연구)

  • Jo, Hyo-Jae;Sohn, Kyoung-Ho;Park, Chung-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.31 no.10
    • /
    • pp.813-818
    • /
    • 2007
  • There are the C.W.C and Towing Tank to the model-test equipments of the boat. A model testing of the high speed boat have a difficult in the performance verification because of very a small the scale-ratio of the ship-model and restricted by flow-velocity of the C.W.C and X-carriage velocity of the T.T. In general, the stepped hull boat is a high of fuel-efficiency because of the resistance reduction by a small wetted surface-area in correspond without stepped-hull boat. But It have a tendency to be bad the rolling performance by reduced stern wetted-area In this paper, the high speed stepped planning-boats with & without attached a stern body were performed to compare the effect of resistance and rolling performance by using sea model-test method.

Overhead Rigid Conductor and Transition Structure for High-Speed (Over 250 km/h) I : Structural Design (250 km/h급 고속용 강체전차선 및 이행장치 I : 구조설계)

  • Kim, Bong-Suk;Won, Yong-Hee;Park, Seol-Hee;Bae, Sang-Joon;Jang, Kwang-Dong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.1
    • /
    • pp.7-13
    • /
    • 2016
  • With the increasing running speed of trains, new railway lines in metropolitan areas, and the rising demand for green transportations, the number of underground and tunnel sections are constantly becoming larger, and installations of overhead rigid conductor systems are becoming wider. However, domestic commercial products for overhead rigid conductors are limited to 120 km/h train speeds. In this study, to develop a high-speed (250 km/h) overhead rigid conductor, R-Bar (Rigid Bar), the electrical and mechanical stability was enhanced through the improvement of the cross sectional shape of the R-Bar; the transition structure was also designed for flexibility and natural frequency isolation. In addition, the evaluation of contact forces between a pantograph and the overhead rigid conductor system for 250 km/h train speeds was performed using dynamic analysis.