• Title/Summary/Keyword: 전지

Search Result 10,260, Processing Time 0.037 seconds

Synthesis and Electrochemical Properties of Li1-xFeO2-yFy-LixMnO2 (Mn/(Mn + Fe) = 0.8, 0≤y≤0.15)) Cathode Materials by Anion Substitution (음이온 치환을 이용한 Li1-xFeO2-yFy-LixMnO2 (Mn/(Mn + Fe) = 0.8, 0≤y≤0.15) 양극 활물질의 합성 및 전기화학적 특성)

  • Heo, J.B.;Park, G.J.;Lee, Y.S.
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.239-244
    • /
    • 2007
  • In order to investigate the effect of fluorine ion in the $Li_{1-x}FeO_2Li_xMnO_2$ (Mn/(Mn + Fe) = 0.8) cathode material, it was synthesized $Li_{1-x}FeO_{2-y}F_y-Li_xMnO_2$ (Mn/(Mn + Fe) = 0.8, $0.05{\le}y{\le}0.15$) cathode materials at $350^{\circ}C$ for 10hrs using solid-state method. $Li_{1-x}FeO_{2-y}F_y-Li_xMnO_2$ (Mn/(Mn + Fe) = 0.8, $0.0{\le}y{\le}0.1$ was composed many large needle-like particles of about $1-1.5\;{\mu}m$ and small particles of about 50-100 nm, which were distributed among the larger particles. However, $Li_{1-x}FeO_{1.85}F_{0.15}-Li_xMnO_2$ material showed slightly different particle morphology. The particles of $Li_{1-x}FeO_{1.85}F_{0.15}-Li_xMnO_2$ were suddenly increased and started to be a spherical type of particle shape. $Li/Li_{1-x}FeO_{1.9}F_{0.1}-Li_xMnO_2$ cell showed a high initial discharge capacity of 163 mAh/g and a high cycle retention rate of 95% after 50 cycles. The initial discharge capacity of $Li/Li_{1-x}FeO_{2-y}F_y-Li_xMnO_2$ ($0.05{\le}y{\le}0.15$) cells increased according to the increase of F content. However, the cycleability of this cell was very rapidly decreased when the substituted fluorine content is over 0.1. We suggested that too large amount of F ion fail to substitute into the $Li_{1-x}FeO_2-Li_xMnO_2$ structure, which resulted in the severe decline of battery performance.

Fabrication and Performance of Anode-Supported Flat Tubular Solid Oxide Fuel Cell Unit Bundle (연료극 지지체식 평관형 고체산화물 연료전지 단위 번들의 제조 및 성능)

  • Lim, Tak-Hyoung;Kim, Gwan-Yeong;Park, Jae-Layng;Lee, Seung-Bok;Shin, Dong-Ryul;Song, Rak-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.283-287
    • /
    • 2007
  • KIER has been developing the anode-supported flat tubular solid oxide fuel cell unit bundle for the intermediate temperature($700{\sim}800^{\circ}C$) operation. Anode-supported flat tubular cells have Ni/YSZ cermet anode support, 8 moi.% $Y_2O_3$ stabilized $ZrO_2(YSZ)$ thin electrolyte, and cathode multi-layer composed of Sr-doped $LaSrMnO_3(LSM)$, LSM-YSZ composite, and $LaSrCoFeO_3(LSCF)$. The prepared anode-supported flat tubular cell was joined with ferritic stainless steel cap by induction brazing process. Current collection for the cathode was achieved by winding Ag wire and $La_{0.6}Sr_{0.4}CoO_3(LSCo)$ paste, while current collection for the anode was achieved by using Ni wire and felt. For making stack, the prepared anode-supported flat tubular cells with effective electrode area of $90\;cm^2$ connected in series with 12 unit bundles, in which unit bundle consists of two cells connected in parallel. The performance of unit bundle in 3% humidified $H_2$ and air at $800^{\circ}C$ shows maximum power density of $0.39\;W/cm^2$ (@ 0.7V). Through these experiments, we obtained basic technology of the anode-supported flat tubular cell and established the proprietary concept of the anode-supported flat tubular cell unit bundle.

Distribution of Hard Ticks based on Environments and Detection of Severe Fever with Thrombocytopenia Syndrome Virus in Sangju city, Korea, 2019 (2019년 경북 상주 지역 환경별 참진드기 분포 조사 및 중증열성혈소판감소증후군 바이러스 검출)

  • Lee, JaeSeok;Moon, KyungHwan;Kim, YeongHo;Park, Ye eun;Jeon, Ji Hyang;Kim, Chae Won;Park, Sean;Woo, Ji Hyeon;Jeong, Yeo Jin;Eom, Jong Won;Lee, Wook-Gyo;Kim, Young Ho
    • Korean journal of applied entomology
    • /
    • v.59 no.3
    • /
    • pp.233-241
    • /
    • 2020
  • Several hard tick species in Ixodidae are medically important pests that transmit infectious disease including severe fever with thrombocytopenia syndrome (SFTS). In Korea, the number of SFTS patients continues to steadily increase since its first report in 2013, and Gyeongsangbuk-do (province) is the second most frequent area of SFTS patient occurrence. In order to investigate the distribution of ticks in Sangju city, we collected ticks using the flagging method from 26 sites comprising urban green area, vulnerable area of management, and rural area, and examined SFTS virus from the collected ticks in 2019. Based on Collection Index (CI = tick number / 1 h / 2 people), CI 143 ticks, including Haemaphysalis longicornis, Haemaphysalis flava, and Ixodes nipponensis, were collected; the most abundant species among the three tick species was H. longicornis (CI 138, 96.5%). Ninety two percent (CI 131) of ticks were collected in vulnerable area of management, where people cannot easily enter and are not managed by city hall, whereas only 8.4% (CI 12) were collected in the urban green area and rural area. Regarding SFTS virus detection, virus was not investigated from 26 pools containing CI 143 ticks. The results of this study are expected to be used as a recommendation for ensuring the safety of local residents from tick-borne diseases.

Meridic Diets for Rearing of Spodoptera frugiperda Larvae (열대거세미나방 유충 사육을 위한 반합성 인공사료)

  • Jung, Jin Kyo;Kim, Eun Young;Kim, I Hyeon;Ahn, Jeong Joon;Lee, Gwan-Seok;Seo, Bo Yoon
    • Korean journal of applied entomology
    • /
    • v.59 no.3
    • /
    • pp.243-250
    • /
    • 2020
  • Two meridic diets, N4 and N6, containing pinto bean, wheat germ, soybean, whole milk and sucrose as main nutrients were developed for rearing Spodoptera frugiperda (Noctuidae) larvae. Six larval instars were observed when neonate larvae were individually raised on these diets in small petri-dishes (ø 50 × 10 mm, 19.6 ㎤) at 25℃ and 15:9 h (light:dark) photoperiod. The average pupation rate of 97.8% on the N4 diet was significantly higher than the rate of 85.6% on N6 diet. The emergence rates were 92.0% on N4 diet and 93.5% on N6 diet, with a non-significant difference. The larval periods were 17.9 and 17.7 days for females, and 18.7 and 18.5 days for males, for N4 and N6 diets, respectively, with non-significant differences between diets and sexes. The pupal periods on both diets were identical (11.1 days for females and 12.8 days for males), despite differences between sexes. The pupal weights of both sexes on N4 diet were identical with a value of 257 mg, whereas those on N6 diet were 256 and 263 mg for females and males, respectively, with a non-significant difference. The longevity of female adults that emerged on N6 diet was 13.8 days and longer than 8.6 days on N4 diet. The pre-oviposition periods were 5.0 and 4.2 days on the N4 and N6 diets, respectively, with a non-significant difference, however, the oviposition period of 6.5 days on N6 diet was longer than the period of 3.9 days on N4 diet. The effective fecundity on N6 diet was 1,392 eggs (maximum 1,776) and was higher than that of 942 eggs (maximum 1,694) on N4 diet, with a non-significant difference. The egg hatching rates on N4 and N6 diets were 79.2 and 79.8%, and egg periods were 3.0 and 2.9 days, respectively, with non-significant differences.

Plasma Transforming Growth Factor-$\beta$1 Levels of Cancer Patients (암 환자의 혈장 Transforming Growth Factor-$\beta$1 농도)

  • 전지현;이시은;이수진;박찬후;장정순;하우송;박순태;박병규
    • Biomedical Science Letters
    • /
    • v.5 no.2
    • /
    • pp.181-190
    • /
    • 1999
  • To evaluate the usefulness of transforming growth factor-$\beta$1 (TGF-$\beta$1) as a new tumor marker, we determined the plasma TGF-$\beta$1 levels using sandwich ELISA assay in cancer patients. Patients with three most common adult cancers in Korea (stomach, liver and breast cancer) and children's cancers (leukemia and two kinds of solid tumor) were enrolled for the study. Furthermore, 39 individuals were subjected to age and sex-stratified plasma TGF-$\beta$1 analysis. No statistical difference was demonstrated with respect to age or sex. The mean plasma TGF-$\beta$1 level (16.0 ng/ ml) of stomach cancer patients was significantly higher than that (8.3 ng/ml) of controls. However, there was no difference among the mean plasma TGF-$\beta$1 levels of liver, breast cancer patients and controls. Seven of 16 patients (43.7%) with stomach cancer, one of 8 (12.5%) with liver cancer, and one of 7 (14.3%) with breast cancer showed higher TGF-$\beta$1 levels compared to controls. Plasma TGF-$\beta$1 concentrations of five leukemic children remained in the normal range regardless of the remission state. In contrast, initial high TGF-$\beta$1 levels from two children with solid tumors returned to normal range on surgical resection of tumors. From the above results, we could conclude that plasma TGF-$\beta$1 levels of apparently healthy individuals seem to be rather constant irrespective of difference in age or sex, and the plasma TGF-$\beta$1 has the limited value as a screening test for the diagnosis of aforementioned adult cancers because of its low sensitivity. Finally, additional studies need to be pursed for the large number of stomach cancer and pediatric solid tumor patients in order to reach a secure conclusion on the usefulness of plasma TGF-$\beta$1 as a tumor marker in these patients.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Antioxidative Effects of Inula britannica var. chinensis Flower Extracts According to the flowering period and species of Inula britannica var. chinensis (금불초 종(種) 및 개화시기에 따른 금불초 꽃 추출물의 항산화 효능)

  • Kwon, Soon Sik;Jeon, So Ha;Jeon, Ji Min;Cheon, Jong Woo;Park, Soo Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.39 no.3
    • /
    • pp.195-203
    • /
    • 2013
  • In this study, antioxidative effects of the extracts of different species and flowering periods of Inula britannica were investigated. According to the free radical (1,1-diphenyl-2-picrylhydrazyl, DPPH) scavenging activity of the extracts, The I. britannica var. chinensis flower extract (500 ${\mu}g/mL$) was measured in a 79.89% free radical scavenging activity, but the flower extracts of similar species (I. britannica var. linariaefolia Regel, I. britannica var. ramosa, I. salicina var. asiatica) did not show any effect on the free radical scavenging activity. The effects of the free radical scavenging activity of I. britannica var. chinensis flower extracts were exhibited in the order of full bloom (93.68%), bud (43.28%), and fallen blossom (14.11%). Next, we established optimum condition of extract solvent, temperature, extraction time. The extract from ethanol at $60^{\circ}C$ showed the most free radical scavenging activity among other conditions and extraction time not relevant in free radical scavenging activity. The protective effects of the extract of I. britannica var. chinensis flower on the photohemolysis of human erythrocytes by using rose bengal were increased in a concentration-dependent manner (5 ~ 50 ${\mu}g/mL$). In particular, the extract in 50 ${\mu}g/mL$ concentration exhibited better protective activity (${\tau}_{50}$ = 116.1 min) than (+)-${\alpha}$-tocopherol (${\tau}_{50}$ = 73.44 min), which is a known lipophilic antioxidant. Principle component of I. britannica var. chinensis flower was identified as quercetin of flavonoids by high-performance liquid chromatography (HPLC). These results indicate that the extract of I. britannica var. chinensis flower can function as antioxidants in biological systems, particularly skin exposed to UV radiation by scavenging free radical and $^1O_2$, and protect cellular membranes against ROS. It is concluded that the antioxidative effects of the extract of I. britannica var. chinensis flower could be applicable to functional cosmetics.

Empirical Study of Key Factors in Satisfaction with Subway Services (지하철 이용만족도 결정요인에 관한 실증적 연구 -서울지역을 중심으로-)

  • Shim, Jong-Seop;Jeon, Ki-Heung
    • Korean Business Review
    • /
    • v.13
    • /
    • pp.49-66
    • /
    • 2000
  • Despite the fact that understanding customers satisfaction with transportation services is a subject of great importance, authors, so far, found no systematic researches referred to that issue. From this point, studying the satisfaction with subways services can be extremely useful. Empirical study of key factors in the satisfaction with subway services is the departure point, which holds as objectives, and we believe, will contribute to overall increasing in the number of subways services used and in the amount of public benefits derived from that usage. In order to achieve these goals: First, several items referred to some key factors in the satisfaction of subway usage were systemized. Second, a research of specific weights attached to those key factors by subway passengers was conducted. Knowledge of the satisfaction variables system can provide deep insights into ones perceptual experience when using a subway. The results were as follows: Various interrelated factors compose a passengers satisfaction with subway services. People do not just use subway passively; a number of key factors, like physical and personal services, exact timing, easiness to access etc. determine the passengers satisfaction with subway. In order to find out specific weights of these key factors multiple regression analysis was employed. Results showed that satisfaction with subway is determined by (in order of importance) easiness to access, quality of physical services, friendliness of working stuff and timing exactness. According to the findings, passengers do not use subway as a simple mean of transportation, rather they perceive it as a complex combination of environmental elements and overall satisfaction depends on these various factors. Therefore, to learn passengers satisfaction with subways services, passengers subway experience must be thoroughly studied and analyzed, and this is where papers value resides.

  • PDF

A Study on the Smog Reduction Strategies in China (중국의 스모그 저감정책에 대한 고찰)

  • Jeon, So Hyeon;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.11 no.3
    • /
    • pp.63-75
    • /
    • 2015
  • Atmospheric environment in Korea is influenced by outside, especially China. The concentrations of air pollutants in China have showed decreasing trends since 2000. However, these concentration levels in China are still higher than other developed countries. The Chinese Government has tried several measures to control the air pollution. In this study, the details of the amendments and smog reduction strategies in China, especially for Beijing are reviewed and the strategies for Korean side to promote cooperation in Northeast Asia are suggested and discussed. The Chinese State Council amended the Environmental Protection Provisions and Clean Air Act and announced The Action Plan for Air Pollution Control (2013-2017), focusing on three key regions, Beijing-Tianjin-Hebei area (Jing-Jin-Ji), Yangtze River Delta (YRD) and Pearl River Delta (PRD). These policy actions and plan are mainly for the reducing coal usage and emissions from vehicles. It is suggested that, Korea should actively promote multi-national cooperation in the region to take an initiative role in environmental areas.