• Title/Summary/Keyword: 전자파영향

Search Result 827, Processing Time 0.028 seconds

Effects of Catechin on Mixed Function Oxidase System and Oxidative Damage in Rat Liver Exposed to Microwave (전자파 조사 흰쥐 간조직의 Mixed Function Oxidase System과 산화적 손상에 미치는 Catechin의 영향)

  • 김미지;이준하;이순재
    • Journal of Nutrition and Health
    • /
    • v.34 no.3
    • /
    • pp.299-305
    • /
    • 2001
  • The purpose of this study was to investigate the effects of catechin on the changes of microsomal mixed function oxidase(MFO) system and oxidative damage in rat liver exposed to microwave. Sprague-Dawley male rats weighing 200$\pm$10g body weight were randomly assigned to one normal and microwave exposed groups: microwave exposed groups were divided three groups: catechin free diet(MW) group, 0.25% catechin(MW+0.25C) group and 0.5% catechin(MW+0.5C) group to the levels of dietary catechin supplementation. The rats were irradiated with microwave at frequency 2.45GHz for 15 min and then the changes pattern of mixed function oxidase system and oxidative damage were investigated for 16 days. The activity of XOD in MW group was increased from 4 day to 8 days after irradiation, compared to normal group and decreased to the level of normal group 16 days. But catechin supplementation group were maintained to the normal level. The contents of cytochrome P(sub)450 and NADPH cytochrome P(sub)450 reductase activities in liver of MW group was increased from 4 day to 8 day after irradiation, compared to normal group and decreased to the level of normal group at 16 day. But catechin supplementation group were recovered to the normal level. The contents of superoxide radical in liver of MW group was increased 1.28, 1.25, 1.17 fold of normal group at 4,6 and 8 days days after irradiation. respectively, but catechin supplementation group were maintained the normal level. The contents of lipifuscin in liver have a same tendency in superoxide radical contents. These result suggested that the supplementation of catechin have control the mixed function oxidase system and oxidative damage and that may help to recover tissues from microwave damage. (Korean J Nutrition 34(3) : 299~305, 2001)

  • PDF

A Study on the Effects of Electroencephalogram of Blocking Electromagnetic Wave Materials by useing the Nano Silver (나노 은을 이용한 전자파 차폐 직물이 뇌파에 미치는 영향)

  • Lee, Su-Jeong;Lee, Tae-Il
    • Fashion & Textile Research Journal
    • /
    • v.6 no.6
    • /
    • pp.810-814
    • /
    • 2004
  • This study is one of the fundamental researches for the development of future smart clothing and textile products using silver(Ag) nano powder. Our study was focused on the blocking or insulating effects of nano-processed textiles from electromagnetic waves. Also, for the surveying of the actual effect to human body, we measure the variation of electroencephalogram which is an indication of human physical symptoms. Among various textiles in this experiment, nano silver processed case has shown the best blocking performance from the electromagnetic waves, which decreases depending on the distance. As a reference model of working environment, we setup the visual stimuli object on the computer that is a source of electromagnetic wave. The power spectrum distribution and the incidence of electroencephalogram was measured. The analysed data has shown that, with nano-processed textiles, ${\beta}$ wave does not appear very often where ${\beta}$ wave appears only to illustrate the stable states of human's body. However, as for the materials without nano processing, the ratio of ${\gamma}$ waves in the total level of electroencephalogram becomes higher in spite of short exposure to visual stimuli in work environment, which shows that the worker becomes stressed. The ${\beta}$ wave electroencephalogram of all materials is drawn in calcarine fissure of occipital lobe to show the convergent distribution, and stronger with block-processed Nano Silver Silk(NSS). The study based on the potential risks of human diseases such as physical fatigue by electromagnetic waves, and has shown that the application of Nano Silver textile for human uses require a proper particle size of it which would not penetrate cellular tissues, and a proper binder and binding treatment for it. However, it is highly required for back-up researches to verify various aspects in applying nano silver to textile products.

Effect of Green Tea on Mixed Functon Oxidase System and Xanthine Oxidase Activities in Rat Liver Exposed to Microwaves (전자파를 조사한 흰쥐 간조직에서의 Mixed Function Oxidase System과 Xanthine Oxidase 활성에 미치는 녹차의 영향)

  • 이순재;이용희
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.1
    • /
    • pp.168-173
    • /
    • 2000
  • The purpose of this study was to investigate the changes of microsomal mixed function oxidase (MFO) and xanthine oxidase activities (XOD) in the liver of rats exposed to microwave. Sprague-Dawley male rats weighing 200$\pm$10g body weight were randomly assigned to a normal and microwave exposed(MW) groups; microwave exposed groups were divided into two groups; microwave (MW) group and green tea(GT) gropu which were fed distilled water and green tea extracts during experimental periods, respectively. Rats were irradiated with microwave at the frequency of 2.45 GHz for 15min and rats wre sacrificed at the 4th day of the microwave irradiaton. The hemoglobin level of GT group was higher than that of the normal gropu and MW group, but the hematocrit value was not significantly different among all experimental gropus. The activity of serum GOT of MW group was significantly increased but that of GT group was similar to normal group. Activities of GPT were not significantly different among all experimental groups. Liver XOD activity was significantly increased in the microwave exposed groups but green tea normalized the XOD activity. The activity of hepatic microsomal cytochrome P450 was significantly increased in MW group compared to normal group and that of GT group was similar to that of the normal group. The activity of hepatic microsomal NADPH-cytochrome P450 reductase was also significantly increased in MW group compared to normal group, but that of GT group was similar to that fo the normal group. In conclusion, the activities of MFO and XOD were elevated by microwave irradiaton, but the activation of MFO system as well as the damage of the liver by microwave were reduced by green tea supplementation.

  • PDF

A Study on Design and Fabrication of Broad-Band EMC Filter for PC (PC용 광대역 EMC 필터의 설계 및 제작에 관한 연구)

  • Kim, Dong-Il;Jung, Sang-Wook;Kim, Min-Jung;Jeon, Joong-Sung
    • Journal of Navigation and Port Research
    • /
    • v.28 no.8
    • /
    • pp.715-719
    • /
    • 2004
  • This paper deals with EMC filter for a personal computer(PC). A PC contains many sources of noise inside and out, with many connected cables. High noise levels are also emitted from the PC because of high-speed signals. So radiated noise from the computer body may sometimes cause problems. Therefore, we design and fabricate an electromagnetic compatibility (EMC) filter for PC, which is composed of feed-through capacitors and ferrite beads with high permeability. Through extensive test, the proposed EMC filter is shown to have excellent differential-mode and common-mode noises filtering characteristics above 30 dB in the frequency band from 10 MHz to 1.5 GHz. The immunity characteristics are improved more than 10 to 30 dB over the frequency band from DC to 1.8 GHz.

Color Space Mapping and Medium Access Control Techniques in Visible Light Communication (가시광통신을 위한 색채공간매핑과 MAC 기법 연구)

  • Rahman, Mohammad Shaifur;Kim, Byung-Yeon;Bang, Min-Suk;Park, Young-Il;Kim, Ki-Doo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.4
    • /
    • pp.99-107
    • /
    • 2009
  • Visible Light Communication (VLC) is a promising wireless communication technology. It offers huge, worldwide available and free bandwidth without electro-magnetic interference, which makes it very attractive for RF-sensitive operating environments. We propose colored LED-based VLC system for hospital use which includes voice recognition system for operating the medical equipments. New Mr hlation Scheme based on the Light Color Space is suggested to overcome the effect of noise generated by background light. Different color space constellations for different symbol sizes are also suggested which would give better bit error rate performance. Finally, Slotted ALOHA or TDMA medium access control protocols are suggested for multi-user operations.

  • PDF

Wave Propagation characteristic from Composite structures (복합형 구조에서의 전자파전파 특성)

  • Yoon, Kwang-Yeol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.3
    • /
    • pp.343-348
    • /
    • 2011
  • With the rapid and wide-spread use of mobile communications much attention has been focussed on propagation in the urban area crowed with buildings. It is often surrounded by hills, forests, and mountains. The importance of surface scattering interference between transmitters and receivers on the rough surfaces has been interested and investigated. Therefore, a prediction method is necessary to estimate the influence of rough surfaces on microwave radio propagation. Moreover, most of the mobile communications are performed based on the digital communication system rather than the analog one. In this case, we must pay more careful attention to the signal delay caused by the phase delay due to the multi-path propagation. In this paper we have analyzed numerically scattering of electromagnetic waves from Composite structures by using FVTD (Finite Volume Time Domain) method. We consider two different types of rough surfaces such as periodic and composite structures.

Health Status of Electric Utility Workers Exposed to Extremely Low Frequency Electromagnetic Field (ELF-EMF) (근로자들의 극저주파 전자파 노출 수준에 따른 인체 영향 평가)

  • Park, Kyoung-Ho;Ahn, Yong-Ho;Kim, Tai-Jeon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.3
    • /
    • pp.220-227
    • /
    • 2005
  • Recently, the use of an electrical apparatus has brought up concerns of health risks from exposure to electromagnetic fields. EMF is composed of electric fields and magnetic fields. Heavy exposure to EMF can occur only in the vicinity of high-voltage overhead transmission lines, close to transformers and underground cables, and also close to large electrical machinery. In this thesis I have investigated the hypothesis of the correlation between occupational exposure to ELF-EMF and the risks of leukemia, anemia, cancer. Therefore, the aim of this study is to investigate whether or not ELF-EMF emitted from electric power stations and transformer substations affect some hematological parameters and tumor markers of electric utility workers. The hematological test results and tumor markers under investigation were similar in the two groups but some of parameters such as RBC, AFP, LDH showed significant difference between the two groups from two sample t-test (p<0.05). The exposure group showed increased LDH level compared to the control group by two sample t-tests. In addition, the abnormal LDH level in the exposure group was observed to be clinically significant by ${\chi}^2$-test. However, the levels of RBC, AFP observed were not clinically significant by ${\chi}^2$-test (p>0.05). These results suggested that ELF-EMF does not affect most blood test parameters except LDH of electric utility workers.

  • PDF

Smart Manhole Device for Underground Facility Management (지중 시설물 관리를 위한 스마트 맨홀 디바이스)

  • Kim, Jong-Duk;Han, Seung-Heon;Kim, Yong-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.8
    • /
    • pp.996-1003
    • /
    • 2019
  • The undergrounding of diverse ground facilities has led to a decrease in issues, such as foul smell of water supply systems and wastewater, a fall of telephone poles, electromagnetic waves and breaking of wires caused by a railway work. On the other hand, there are new issues, including a fall accident, explosion affected by flammable gas, a choking accident by harmful gas and a lack of oxygen concentration, a fire coming from high-tension wire heating and flooding in the manhole. Besides, these issues damage the civil society and are an anxiety to public safety. Therefore, this paper is focused on a smart manhole device for stable communication environments inside and outside the manhole and wireless communication with various devices for managing facilities in the manhole, and aims to make a contribution to public safety by suggesting a direction of future underground facility management.

The Effects of Productization, Organizational, Overseas Market Adaptation Competences on Export Performance: Focus on Korean Electromagnetic Wave Shielding Firms (기업의 제품화 역량, 조직역량, 해외시장 적응역량이 수출성과에 미치는 영향: 전자파 차폐 기업을 중심으로)

  • Park, Won-Cheol;Oh, Ka-Young
    • Asia-Pacific Journal of Business
    • /
    • v.11 no.3
    • /
    • pp.307-344
    • /
    • 2020
  • Purpose - The purpose of this study is to examine effects of productization and organizational competences on export performance of electromagnetic shielding companies and to analyze moderating effects of overseas market adaptation competences. For this, hypotheses were established by reviewing previous studies and an empirical analysis was conducted for testing. Design/methodology/approach - For this study, a survey was conducted for workers at electromagnetic shielding companies and 250 valid responses out of 300 questionnaires were aquired. A frequency analysis of related variables was conducted. Through an exploratory factor analysis, validity and reliability tests of measuring tools were conducted and a descriptive statistics was analyzed for collected data result and hypotheses testing. Findings - A correlation analysis was conducted to examine relationships among variables. Construct, convergent and discriminant validities were analyzed after a confirmatory factor analysis and a multi-group confirmatory factor analysis. Finally, with a verified model, the hypotheses and the moderating effects were tested. The results are as follows: First, the productization competence has a positive effect on export performance; Second, the organizational competence has a positive effect on export performance. Especially, the organizational competence has more effect on export performance than the productization competence. Although a development of new technology and product is important in terms of performance, along with these competences, a way of acquiring new skills and knowledge, and internalization and adaptation in organizations have more effect on export performance. Third, overseas market adaptation competence moderates effects of organizational and productization competences. Research implications or Originality - It is necessary to seek out opportunities for workers to participate in actively, such as conferences and seminars, to strengthen organizational competence. It is strongly believed that a constant development of high quality product will contribute to export performance. Lastly, in a policy level, supports on SMEs by governments are to be strengthened by providing with finance and human resource.

Analysis and Improvement of False Alarm Phenomenon of Emergency Hydraulic Warning Light by Shielded RF Radiation Signal (RF 방사 신호 차폐를 통한 비상 유압경고등의 비정상 점등 현상의 원인분석 및 개선)

  • Jung-Hyuk Kwon;Gyeong-Nam Kim;Byeong-Kwon Jeon;Wang-Sang Lee
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.1
    • /
    • pp.68-78
    • /
    • 2023
  • In this paper, improvement measures were studied for false alarm (abnormal lighting) of emergency hydraulic warning light due to RF radiation signals in aircraft. When the warning lamp of the emergency hydraulic system is lit during flight due to electromagnetic interference caused by RF radiation signals, it affects flight mission and safety which can result in efficiency degradation and maintenance of flight mission. For false alarm of emergency hydraulic warning light, root cause analysis and troubleshooting were carried out. By shielding a composite strip under fuselage of the aircraft located in the path of the RF radiation signal, the RF radiation signal flowing into the emergency hydraulic indicator was blocked. Results of applying the improvement method through ground and flight monitoring were also described.