• Title/Summary/Keyword: 전자선 조사

Search Result 755, Processing Time 0.027 seconds

Preparation of EPDM/Polyamide12 Elastomers through Electron Beam Irradiation (전자선 조사를 통한 EPDM/Polyamide12 탄성체의 제조에 관한 연구)

  • Jung, Hyo Shin;Park, Jung Il;Kang, Phil-Hyun;Choi, Myung Chan;Chang, Young-Wook;Hong, Sung Chul
    • Polymer(Korea)
    • /
    • v.37 no.5
    • /
    • pp.571-578
    • /
    • 2013
  • Polyamide12 (PA12) is blended with ethylene propylene diene rubber (EPDM) at various compositions in the presence of maleated EPDM (mEPDM) to afford blend materials having the characteristics of thermoplastic elastomer (TPE). The EPDM/PA12 melt-blends are further irradiated with electron-beam (e-beam) at 0~100 kGy dosage, yielding selective crosslinking between EPDM chains while retaining melt-processibility originated from PA12 phase. mEPDM acts as a compatibilizer and affords additional improvements in mechanical properties of the EPDM/PA12 blend. With 25 kGy of e-beam irradiation and mEPDM, the EPDM/PA12 blends successfully exhibit TPE behaviors with reasonable elastomeric and mechanical properties.

Electrical Properties of Nanostructured Carbon Black-filled HDPE Composites: Effect of Electron Beam Irradiation on PTC Characteristics (나노구조 카본블랙/HDPE 복합재료의 전기적 특성: 전자선 조사에 의한 PTC 특성변화)

  • 박수진;송수완;서민강;이재락
    • Composites Research
    • /
    • v.16 no.1
    • /
    • pp.19-25
    • /
    • 2003
  • In this paper, electrical properties of nanostructured carbon blacks (CB)-filled high density polyethylene (HDPE) composites were investigated as a function of temperature, which were prepared by the conventional melt-mixing method. The composites were irradiated with electron beam in a dosage of 30∼150 kGy to enhance an electronical reproducibility and to reduce a negative temperature coefficient (NTC) phenomenon. And, gel contents (%) of irradiated CB/HDPE composites were estimated by solvent extraction method. From the experimental results. the positive temperature coefficient (PTC) intensity of the composites was strongly depended on the CB content and particle size. And, the increase of gel contents (%) and disappearance of NTC behavior of the composites were identified at a dosage of 60 kGy. It was also found that the electron beam irradiation made an improvement of electrical reproducibility of the composites. This result was probably due to the reduction of the freedom of CB movement at above the melting temperature of the polymer crystalline, resulting in increasing the crosslinking structure of the composites.

감마선 조사된 실크펩타이드의 항산화능 평가

  • Lee, Ju-Un;Seo, Ji-Hyeon;O, Sang-Hui;Yu, Yeong-Chun;Seong, Nak-Yun;Jeong, Il-Yun;Byeon, Myeong-U
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2005.10a
    • /
    • pp.210-213
    • /
    • 2005
  • 감마선 조사된 실크 펩타이드의 전자공여능은 감마선 조사선량이 증가할수록 증가되었으며 IC50은 비조사구에 비해 50${\sim}$70%로 감소되었다. 또한, 실크 펩타이드가 첨가된 햄버거 패티를 감마선 조사하여 측정한 결과 감마선 조사선량이 증가함에 따라 지방 산패도가 증가하였지만 실크 펩타이드 첨가구가 무첨가구에 비해 지방산화가 적은 것으로 나타났다. 이상의 결과는 실크 펩타이드의 첨가가 가열 및 감마선 조사에 의해 발생될 수 있는 햄버거 패티의 지질 산패를 억제시켜 TBA값이 낮아짐을 보여준다.

  • PDF

Evaluating Surface dose of Treatment Immobilization Devices according to their Electron Energy (전자선에너지에 따른 치료보조기구의 표면선량 평가)

  • Park, Chul-Woo;Im, In-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.360-363
    • /
    • 2010
  • This study evaluated surface dose of treatment immobilization devices such as Themo-plastic, Vac-lock, Cotton and Plaster according to their electron energy. Using a linear accelerater, a plane parallel chamber was set up on 6Mev, 9Mev, 12Mev and 15Mev. A distance between a source and a surface was 100cm and a field size was 10cm*10cm. An incident angle was 0 degree and a radiation dose was 100MU. To decrease an error, the measurement repeated 3 times. The analysis reveals that the surface dose of Vac-lock was the highest and Themo-plastic, Plaster and Cotton were high in order.

The variation of chracteristics induced by $Co^60$-$\gamma$ray at the interface and oxide layer of MOS sructure ($Co^60$-$\gamma$선 조사에 따른 MOS구조의 계면 및 산화막내에서의 특성변화)

  • 김봉흡;류부형;이상돈
    • Electrical & Electronic Materials
    • /
    • v.1 no.3
    • /
    • pp.269-277
    • /
    • 1988
  • P형 Si(100)로 제작한 MOS 커패시터에 $Co^{60}$-.gamma.선을 주사한 후 고주파 C-V특성 곡선으로 부터 방사선 조사에 의해 유발된 산화막안의 트랩전하의 거동 및 Si- $SiO_{2}$계면에서의 트랩밀도 분포의 변화를 검토하였다. 산화막 느랩전하는 .gamma.선 흡수선량 증가와 더불어 증가하다가 $10^{7}$ rad 부근에서부터 서서히 포화하는 경향이 나타났으며 게면트랩밀도의 분포모양은 흡수선량의 증가와 더불어 전형적인 이그러진 W자형에서 넓혀진 V자형 분포로 변화하였으나 최소값은 항상 진성페르미준위( $E_{i}$)부근에 있었으며 그 밀도는 1.0*$10^{11}$~7.5*$10^{11}$[개/$cm^{2}$/eV]로 계산되었다. 또한, 일정 바이어스전압하에서의 조사선량에 따른 $V_{fb}$ 의 변화는 현저하지는 않았으나 바이어스 전압을 +12V로 인가할 때 변화방향의 반전상태가 관측되었다. 그 이유로는 Si측의 계면 부근에서 일어난 눈사태 전자가 산화막내로 주입됨에 따라 도너형 양전하의 수가 감소되기 때문으로 추정되었다.되었다.

  • PDF

Calculation of depth dose for irregularly shaped electron fields (부정형 전자선 조사면의 심부선량과 출력비의 계산)

  • Lee, Byoung-Koo;Lee, Sang-Rok;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.79-84
    • /
    • 2002
  • The main cause factor for effective the output, especially in small & irregular shaped field of electron beam therapy, are collimation system, insert block diameter and energy. In the absorption deose of treatment fields, we should consider the lateral build-up ratio (LBR), which the ratio of dose at a point at depth for a given circular field to the dose at the same point for a 'broad-field', for the same incident fluence and profile. The LBR data for a small circular field are used to extract radial spread of the pencil beam, ${\sigma}$, as a function of depth and energy. It's based on elementary pencil beam. We consider availability of the factor, ${\sigma}$, in the small & irregular fields electron beam treatment.

  • PDF

A Study on the Electron Beam Crosslinking of Acrylic Pressure Sensitive Adhesives for Polarizer Film (전자선 조사를 통한 편광필름용 아크릴계 고분자의 가교화 반응에 대한 연구)

  • Park, Jung-Jin;Choi, Hong-June;Ko, Hwan-Soon;Jeong, Eun-Hwan;Youk, Ji-Ho
    • Polymer(Korea)
    • /
    • v.36 no.3
    • /
    • pp.344-350
    • /
    • 2012
  • New pressure sensitive adhesives (PSAs) for polarizer film were prepared by electron beam (e-beam) radiation to acrylic copolymers, and their adhesive properties were investigated. The acrylic copolymers were synthesized by free radical polymerization of $n$-butylacrylate (BA), 2-hydroxyethyl methacrylate (HEMA), and acrylic acid (AA). The acrylic copolymers were coated on PET release films to a thickness of 25 ${\mu}m$, laminated to polarizer films, and then radiated with e-beam at room temperature. Gel fractions of all the acrylic copolymers after e-beam radiation at 50 kGy were higher than 93%, and their crosslinking densities were increased with increasing the content of HEMA units. PSA prepared by e-beam radiation of acrylic copolymer synthesized with a feed ratio of BA/HEMA/AA = 89.5/10/0.5 (w/w/w) at a dose of 50 kGy exhibited the best adhesion performances in terms of peel strength, creep resistance, durability and reliability, and light leakage. It is expected that the preparation method of PSAs via e-beam irradiation will improve the producibility and workability of polarizer film for liquid crystal display.

Cold Pasteurization of Frozen Crushed Garlics using Electron Beam Irradiation and the Stability of Bioactive Components (냉동다진마늘에 대한 전자선 살균 효과와 생리활성 성분의 안정성)

  • Lee, Hyun-Gyu;Jo, Yunhee;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.1
    • /
    • pp.9-14
    • /
    • 2016
  • Recently, the market for ready-to-use vegetables has increased largely due to consumer demands, which led to the production of minimally-processed frozen crushed garlic products. This study was designed to determine the effect of electron beam irradiation (0-7 kGy) on microbial decontamination, bioactive compounds, and antimicrobial activities of frozen crushed garlic obtained from Korea and China. The microbial counts (total bacteria, yeasts & molds) were reduced from log 3-4 CFU/g to non-detectable levels as a result of irradiation at 4 kGy. Irradiation treatment at 4 kGy did not affect the amount of alliin, allicin, total pyruvate, and total thiosulfinate of crushed garlic, however, this dose induced insignificant changes in antibacterial activities against pathogenic bacteria including Bacillus subtilis, Staphylococcus aureus, Salmonella enteritidis, Vibrio parahaemolyticus, and Yersinia enterocolitica. Therefore, electron beam irradiation less than 4 kGy can be considered suitable to improve the microbial decontamination without altering the biological activity of frozen garlics.

Effect of Irradiation, Packaging and Storage on the Oxidation of Cholesterol and Lipid in Pork Longissimus Meat (돈육 등심의 콜레스테롤 및 지질 산화에 전자선 조사, 포장 및 저장기간이 미치는 영향)

  • 신택순;이정일
    • Food Science of Animal Resources
    • /
    • v.22 no.2
    • /
    • pp.137-144
    • /
    • 2002
  • Pork loins that retailed in market were used as experimental samples. Some pork samples in raw state were packaged with PVDC in either aerobic or vacuum condition. The other pork samples were cooked until core temperature reached at 70$\^{C}$ and then packaged immediately in the same way with the raw samples. After these samples were irradiated by electron beam 6 kGy, the samples were stored in a refrigerator (2∼4$\^{C}$). Identification and quantification of cholesterol oxides were performed at 0 and 7 days. The results were following. During the early stage of storage, cholesterol oxides were not produced from the raw meat samples, but with the passage of storage time,7 $\alpha$-hydroxycholesterol, 7$\beta$-hydroxycholesterol, 7-ketocholesterol, 20 $\alpha$-hydroxycholesterol, $\beta$-epoxide and $\alpha$-epoxide, which were not produced during the early stage of storage, were produced. The production of cholesterol and lipid oxidation products were significantly higher (P<0.05) in the meats with aerobic packaging than those with vacuum packaging, Cooked meat after irradiation showed 7 $\alpha$-hydroxycholesterol, 7 $\beta$-hydroxycholesterol, $\alpha$-epoxide and cholestanetriol on the 7th day of storage, although those chemicals were not produced during the early stage of storage. Production of cholesterol oxides was significantly increased (P<0.05) with the passage of storage time for all treatments, and showed significantly lower value (P<0.05) with the vacuum packaging than these for aerobic packaging. Species of cholesterol oxides from irradiated meat after cooking were similar to those from cooked meat after irradiation. Collectively, it was found that the production of cholesterol oxides was more easily affected by packaging condition than irradiation.

DNA Damage by X-ray and Low Energy Electron Beam Irradiation (X선과 저에너지 전자선에 의한 DNA 손상)

  • Park, Yeun-Soo;Noh, Hyung-Ah;Cho, Hyuck;Dumont, Ariane;Ptasinska, Sylwia;Bass, Andrew D.;Sanche, Leon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.53-59
    • /
    • 2008
  • We observed DNA damages as a function of mean absorbed dose to identify the indirect effect of high-energy radiation such as x-ray. Monolayer films of lyophilized pGEM-3Zf(-) plasmid DNA deposited on tantalum foils were exposed to Al $K{\alpha}$ X-ray (1.5 keV) for 0, 3, 7 and 10 min, respectively, in a condition of ultrahigh vacuum state. We compared DNA damages by X-ray irradiation with those by 3 eV electron irradiation. X-ray photons produced low-energy electrons (mainly below 20 eV) from the tantalum foils and DNA damage was induced chiefly by these electrons. For electron beam irradiation, DNA damage was directly caused by 3 eV electrons. Irradiated DNA was analyzed by agarose gel electrophoresis and quantified by ImagaQuant program. The quantities of remained supercoiled DNA after irradiation were linearly decreased as a function of mean absorbed dose. On the other hand, the yields of nicked circular (single strand break, SSB) and interduplex crosslinked form 1 DNA were linearly increased as a function of mean absorbed dose. From this study, it was confirmed that DNA damage was also induced by low energy electrons ($0{\sim}10\;eV$) even below threshold energies for the ionization of DNA.