A Study about the Modelling of Thermoelectric Cooler and the Thermal Transfer Analysis (열전 냉각기의 모델링 및 열전달 해석에 대한 연구)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.11
    • /
    • pp.1291-1296
    • /
    • 2014
  • The thermoelectric cooler is receiving great interest because of advantages such as the precise temperature control capability, the compact and lightweight cooler, and the mechanical vibrationless structure which enhances the reliability compared with the existing vapor compression cooler. However, it is not easy to design the optimal thermoelectric cooler which appropriate to the application because the thermal analysis should be necessary required. Accordingly, this paper studies the methodology of the modelling, sizing and thermal analysis of the thermoelectric cooler using SINDA/FLUINT analysis tool.

Field Cooling Tests of Paddy Stored in Steel Bins with a Grain Cooler (곡물냉각기를 이용한 철제 원형빈에서 벼 냉각)

  • 김의웅;김동철
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.263-268
    • /
    • 2004
  • Two field cooling tests were conducted to evaluate the cooling characteristic of paddy with a prototype grain cooler. The first test was carried out during summer season in a steel bin with 180.3ton of paddy at Sunchon. And the second test was carried out during harvesting season in a steel bin with 272.2ton of paddy at Ulsan. At the first test, initial paddy temperature of 23.6$^{\circ}C$ was dropped to 14$^{\circ}C$, and initial moisture content of 19.9% was dropped to 19.3% after 52.5 hours of cooling. At the second test, initial paddy temperature of 16.1$^{\circ}C$ dropped to 5.5$^{\circ}C$ after 78.0 hours of cooling. And, at the first test, the average air flow rates of chilled air leaving the grain cooler and penetrating the grain layer were 77.5 ㎥/min and 42.5 ㎥/min, respectively. To prevent leakage of chilled air from plenum chamber of steel bin, which was about 45% of the average air flow rates of chilled air leaving the grain cooler, a proper method was required. The average total power consumption at the first test during summer was 22.1 ㎾ with control of fan damper. At the second test, it was 17.4 ㎾ due to controlling the capacity of compressor with unloading solenoid valve and changing the flow rates of hot refrigerant gas flowing into evaporator and reheater from compressor, resulting in 27% reduction of energy consumption.

A Study on Automatic Sensing Device for Water Leakage of Cooling Pipe at Blast Furnace by Use The Electronic System (전자제어 장치를 이용한 용광로 냉각관 누수 지동 감지장치 개발에 관한 연구)

  • Kang, Chang-Soo;Kang, Ki-Seong
    • 전자공학회논문지 IE
    • /
    • v.46 no.4
    • /
    • pp.25-30
    • /
    • 2009
  • The cooling water circulation pipes had been used to drop the temperature of refractory outside shell of blast furnace by cooling plate or stave type. They were attacked by surrounding CO gas and it was the cause that they were corroded and the water inflow in the refractory due to leakage of water. So, the life of refractory material was shorten and changed for the worse the conditions of blast furnace. The automatic sensing device for water leakage of cooling pipe was developed to check the position of trouble by use the micro-process system when cooling water leak and then CO gas will be inflowed into the cooling pipe at the leakage position. The inflowed CO gas will be detected in the micro-process system and delivered the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave the water leakage part immediately and then deliver the signal to main control room by use the micro-process system and wireless-radio relay station. This system will develop the working condition from manual system to unmanned auto alarm system.

Cooling fluid dynamic simulation and measuring of HVDC Valve module and tower (HVDC Valve module 및 tower의 냉각수 유동 해석 및 측정에 관한 연구)

  • Jung, Teagsun;Lee, Jinhee;Baek, Seungtaek
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.161-162
    • /
    • 2014
  • 본 연구의 목적은 HVDC Valve module 및 valve tower에 유입되는 냉각 유체의 유동장 동적 해석과 동시에 냉각 유체의 동적 특성을 측정 비교함으로써 유동 해석의 적합성을 판단하고, HVDC valve module과 valve tower의 냉각 유로 및 관련 기구 설계의 기초 자료로 활용하는데 그 목적이 있다.

  • PDF

A Consideration on the Application of Thermoelectric Cooler to Obesity Therapy (열전 냉각장치의 비만치료 적용 방법론 고찰)

  • Ko, Yun-Seok;Lee, Woo-Cheol;Kim, In-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1437-1442
    • /
    • 2012
  • The contemporary peoples focus on treatment of obesity in order to prevent the adult disease and to manage the beauty. Although surgical treatment of obesity shows the reliable cure effect, it could cause side effects and has a disadvantage that postoperative recovery period is long. Accordingly, this paper compares and analyzes the non-operative treatments which can be of help to treat obesity. Also, it considers the obesity therapy based on the Peltier cooling system. And finally a basic control circuit based on Peltier module is designed for Peltier cooling-based obesity therapy system.

Heat Transfer Enhancement Using Ceramic-Oil Nanofluids for an Airplane Cooling System (세라믹-오일 나노유체를 이용한 항공기 냉각매체의 열전달특성 향상)

  • Jeong, Il-Yeop;Jeong, Mi-Hui;Choe, Cheol;O, Je-Myeong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.46-46
    • /
    • 2008
  • 스텔스 기능을 가진 군사용 항공기는 레이다 망의 추적을 피하기 위해 일반 냉각수 대신에 절연유를 냉각매체로 사용한다. 그러나 절연유는 물에 비하여 열전달특성이 매우 낮기 때문에 항공기 전기전자 기기/부품 발열부를 효과적으로 냉각시키지 못하는 한계성을 가지고 있다. 따라서 본 연구에서는 나노유체(Nanofluid) 개념을 이용하여 절연유에 알루미나 및 질화알루미늄 나노분말을 미랑 분산시킨 나노절연유를 제조하고 이것의 열전달특성을 순수 절연유의 그것과 비교 평가함으로써, 냉각특성이 크게 개선된 새로운 냉매로서의 적용 가능성을 확인하고자 하였다. 다만 나노절연유를 제조함에 있어서 가장 큰 장애물은 오일에 대한 분산성 확보에 있기 때문에, 비드밀 및 초음파를 이용한 나노분말 응집체의 습식분산 및 분산제를 이용한 친유성 표면개질을 동시에 수행함으로써 장시간 안정된 분산성을 확보하도록 노력하였다. 나노유체의 열전도도 및 대류열전달계수는 비정상열선법을 이용하여 측정하였으며, 유체 속의 분말 분산 상태는 원심력을 이용한 분산안정성 평가장치 및 cryo FE-SEM을 이용하여 확인하였다. 또한 분말 형상이 대류열전달에 미치는 영향을 조사하기 위하여 알루미나 나노분말은 구상과 침상의 분말을 모두 사용하였고, 질화알루미늄 외에 다이아몬드 나노절연유도 함께 제조, 평가함으로써 냉각 및 절연특성, 그리고 물리화학적 안정성이 우수하고 실적용 가능성이 가장 높은 재료를 도출하고자 하였다.

  • PDF

A Study on Low Noise Cooling/Ventilation System for Large Electric Motor (대형 전동기 냉각/통풍 시스템의 저소음화 연구)

  • Jo, Hye-Young;Jang, Ji-Sung;Kim, Dong-Hae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.973-974
    • /
    • 2014
  • 대형 전동기의 주요 소음원은 전자기 소음과 냉각/통풍 시스템 소음이며, 이 중 냉각/통풍 시스템이 전체 소음에 큰 영향을 미친다. 본 논문에서는 대형 전동기의 저소음 냉각/통풍 시스템 개발을 위해 저소음 냉각 팬을 개발하고 팬 커버 내부의 유로를 개선하였다. 유동해석은 상용 CFD 소프트웨어를 이용하였으며 팬 커버 내의 scroll 형상 및 air guide, baffle 의 유무에 따라 팬 커버의 압력손실을 계산하였다. 해석을 통해 팬 커버 내부의 난류 유동과 압력손실이 가장 작은 팬 커버 형상을 도출하였으며 개선된 냉각/통풍 시스템이 기존 냉각/통풍 시스템보다 6.5dB 감소된 것을 확인하였다.

  • PDF

A Study on Pump Selecting for Oil Direct Cooling Type Power Transformer (강제송유 냉각방식 변압기 펌프선정 기준 정립에 관한 연구)

  • Kim, Seong Eon
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.62-63
    • /
    • 2014
  • 전력용 변압기에서 강제송유 냉각방식을 채택할 경우 절연유 강제 순환을 위한 펌프가 필요한데, 매 설계 시 마다 유동해석 혹은 설계 프로그램을 통해 펌프를 선정하게 되면 상당한 시간이 소요된다. 이러한 시간적 손실을 줄이고자 유동해석 및 유체 이론에 근거하여 간단하게 엑셀 시트로 프로그램화 하였다.

  • PDF