• 제목/요약/키워드: 전자기 유량계

검색결과 30건 처리시간 0.03초

전자기유량계의 개발및 신호 특성에 관한 연구 (A study on the development of an electromagnetic flowmeter and the characterization of flow signal)

  • 임기원;김창호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.361-364
    • /
    • 2002
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The measuring tube of the EMF was basically designed as 100 m diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. To obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF For the characterization of EU, the uncertainty of calibrator was estimated within ${\pm}0.5{\%}$, the method of estimation was in accordance with the ISO 17025 recommendation. It was found that the flow signals between the electrodes were about ${\pm}60\;-\;{\pm}300{\mu}V$, which were sufficient for the discrimination of the flowmeter and protecting the noise. The test result against the calibrator, showed the good linearity in the range of $3 m^{3}/h\;and\;70m^{3}/h$. A commercialized design of the EMF will be technically more competitive in domestic and foreign market.

  • PDF

표면유속측정을 통한 평균유속과 유량산정 방법 (Calculation of mean velocity and Discharge Method using Water Surface Velocity Measurements)

  • 임혁진;설명수;정문수;김삼은;김치영
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.503-503
    • /
    • 2017
  • 대부분의 자연하천에서 유량조사는 하천 횡단면의 유속을 측정하여 수위-유량관계로부터 유량을 산정하고 있다. 유속의 측정은 통상적으로 횡단면을 일정 구간으로 구분하여 회전식, 전자식 유속계, 부자 등과 같은 접촉식 장비를 이용하여 일차원 유속으로부터 구간을 대표하는 평균유속을 기반으로 유량을 산정하고 있다. 그러나 이런 접촉식 장비를 통한 유속 측정은 인력, 장비, 비용 및 돌발 호우사상의 측정자의 안전 등 현장 조건의 한계로 관측자료를 확보하지 못 하는 미측정 영역이 발생한다. 이에 따라 수위와 유량측정성과로 개발된 수위-유량관계곡선식은 미측정 구간인 외삽구간에서 정확도가 낮은 유량자료가 산정될 수 있다. 이에 따라 본 연구에서는 하천 횡단면의 일부 고정된 지점에서 측정된 표면유속을 이용하여 유량규모에 따른 평균유속의 상관관계를 분석하고 수위-유량관계곡선으로 산정된 유량과 비교함으로써 비접촉식 유속 측정방식을 통한 유량산정의 활용성과 적용성을 검토하였다. 이를 통해 표면유속을 활용한 유량산정의 실무적인 방법론을 제시하고 고수위 외삽구간의 유량을 비교 및 검증하였으며 수위 1.23m 이상에서 표면유속(0.62m/s ~ 2.69m/s)과 평균유속의 관계는 구간별로 일정한 선형관계가 나타났으며 각 구간에 대한 상관계수는 $R^2=0.97$ 이상으로 높게 나타났다. 이상의 결과는 비접촉식 표면유속측정으로 홍수기 중고수위 이상에서 접촉식 유속계가 갖는 한계를 보완하여 연속적인 유량생산이 가능하고 개발된 수위-유량관계곡선식의 외삽구간을 검토할 수 있는 참고자료를 획득하여 고수위 유량자료의 신뢰성을 높일 수 있는 것으로 판단된다.

  • PDF

도수터널 운영에 따른 최적 수질 관리 (Optimal Water Quality Management due to Operation of Diversion Tunnel)

  • 장석환;오경두;오지환
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2016년도 학술발표회
    • /
    • pp.358-358
    • /
    • 2016
  • 본 연구에 앞서 가뭄에 따른 충청남도 서부권의 물 부족을 해결하기 위하여 금강 본류로부터 보령댐으로 일정 유량을 도수(diversion)하는 계획이 금강 본류에 미치는 수리적 영향을 1차원 비정상류 해석(unsteady flow analysis)을 통하여 분석하였으며, 본 연구에서는 수리모형 결과와 연계하여 수질 모형을 구축하여 금강 본류 수질에 미치는 영향을 알아보고자 하였다. 조위 영향에 따른 염도의 역류 모의를 위하여 전자해도와 위성영상자료를 활용하여 금강 하굿둑에서 외해 방향으로 약 9km에 이르는 모의 구간을 확장하였으며, 상류단의 진두수위표를 포함한 8개 지천의 유입유량 및 수질, 하구의 조위와 염도, 농공용수 취수시설의 취수량 및 회귀수 수질, 금강 배수갑문 운영, 대상 구간에 인접한 기상대의 기상자료 등을 고려하고 금강 본류를 따라 9개 수질측정소의 수질자료를 이용하여 모형의 보정을 실시하였다. 또한 대상 구간 내 2015년의 갈수기 유황 분석을 토대로 비선형 회귀분석식을 도출하여 2016년 갈수기 예측 유량과 함께 수질-유량 관계식을 도출하여 대상 구간의 수온, 염도, 용존산소(DO), BOD, 조류 등 영향을 분석하였다. 수온 분석 결과, 지점에 따라 2015년 유황 대비 평균 수온 1.79~3.83도, 최고 수온 1.74~4.30도 상승할 것으로 모의되었으며, 염도는 2016년 갈수기 동안의 금강 하굿둑 외해 염도는 담수 방류량의 감소로 전년 동기 대비 평균 53% 증가하는 것으로 모의되어 기수역 생태계에 상당한 영향을 줄 것으로 분석되었으며, 갈수기 동안의 금강 하굿둑 내수의 염도는 배수갑문 개방 빈도, 개방 시간, 개방 정도의 감소에 따른 해수 역류의 감소로 전년 동기 대비 크게 감소할 것으로 모의되었다. 용존산소는 2016년 갈수기 동안의 용존산소 농도는 지점에 따라 전년 동기 대비 평균 4~11% 감소하는 것으로 모의되었으며, 2016년 갈수기 동안의 BOD 농도는 지점에 따라 전년 동기 대비 평균 30~57% 증가하는 것으로 분석되었다. 조류는 지점에 따라 전년 동기 대비 평균 29~67% 증가하는 것으로 모의되었다. 유량의 감소에 따른 수온 증가 및 수질 악화의 영향이 있을 것으로 분석되나, 도수에 따른 영향은 상대적으로 제한적인 것으로 분석되었다.

  • PDF

곡관의 하류에 설치된 전자기유량계의 유량신호 특성에 관한 실험적 연구(난류 유동) (An Experimental Study on Installation Effects of Pipe Elbow on the Electromagnetic Flowmeter Characteristics (Turbulent Flow))

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1613-1621
    • /
    • 2002
  • An electromagnetic flowmeter(EMF) essentially averages the velocity distribution over the pipe cross- sectional area, and the measured value is dependent on the velocity profiles. In this study, installation effects of 90$^{\circ}$long elbow(KS B 1522, ISO 3419) on the EMF characteristics was investigated. A commercial EMF was adopted and the distribution of magnetic field in the electrodes cross section was measured. In the experiment, the national flow standard system, of which measurement uncertainty was evaluated in accordance with ISO 17025 recommendation, was used fur characterization of EMF. The leading line has 150D long straight pipe to established a fully developed flow before entering into the elbow and the elbow was installed downstream of it. then the flowmeter was tested within 50 D from the elbow. The installation effects of the flowmeter were investigated by varying the mean velocity(Reynolds No.)in pipe section, the locations and the direction of electrodes plane.($\phi$) From the experimental results, we find the optimal conditions to get most accurate measurements. Generally, the deviations from the calibration value were less than 0.5 % in farther than 10D distance from the elbow and the direction of electrode plane. $\phi$ = 90$^{\circ}$yielded the smallest measurement deviation. These characteristics were shown consistently in turbulent region regardless of the mean Reynolds number.

전자기유량계를 이용한 기포 및 슬러그 유동 측정방법 연구 (Flow Measurement in Bubbly and Slug Flow Regimes Using The Electromagnetic Flowmeter Developed)

  • 차재은;안예찬;서경우;김무환
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1559-1569
    • /
    • 2002
  • In order to investigate the characteristics of electromagnetic flowmeter in two -phase flow, an AC electromagnetic flowmeter was designed and manufactured. In various flow conditions, the signals and noises from the flowmeter were obtained and analyzed by comparison with the observed flow patterns with a high speed CCD camera. The experiment with the void simulators in which rod shaped non-conducting material was used was carried out to investigate the effect of the bubble position and the void fraction on the flowmeter. Based on the results from the void simulator, two -phase flow experiments encompassed from bubbly to slug flow regime were conducted. The simple relation $\Delta$ $U_{TP}$ = $\Delta$ $U_{SP}$ (l-$\alpha$) was verified with measurements of the potential difference and the void fraction. Due to the lack of homogeneity in a rent two -phase flow, the discrepancy between the relation and the present measurement was slightly increased with void fraction and also liquid volumetric flux jf. Whereas there is no difference in the shape of the raw signal between single-phase flow and bubbly flow, the signal amplitude for bubbly flow is higher than that for single -phase flow at the same water flow rate, since the passage area of the water flow is reduced. In the case of slug flow, the phase and the amplitude of the flowmeter output show dramatically the flow characteristics around each slug bubble and the position of a slug bubble itself. Therefore, the electromagnetic flowmeter shows a good possibility of being useful for identifying the flow regimes.ul for identifying the flow regimes.

음극아크증착으로 제조된 TiMoN 박막의 물리적 특성

  • 양지훈;김성환;변인섭;이경황;정재인
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.38-38
    • /
    • 2018
  • TiMoN 코팅층은 우수한 내마모 특성과 낮은 마찰계수를 보여 많은 연구가 진행되고 있다. 본 연구에서는 음극아크 증착으로 질소 가스 유량, 아크 전류, 기판 전압 등 공정 변수를 제어하여 TiMoN 코팅층을 스테인리스와 초경 기판 위에 제조하고 색상, 미세구조, 경도 등 물리적 특성을 평가하였다. TiMo 타겟은 Mo가 약 8 at.% 함유되어 있으며 직경은 80 mm이었다. 색차계를 이용하여 TiMoN 코팅층의 색상을 분석한 결과, 질소 유량이 증가할수록 $a^*$$b^*$ 값이 증가하는 경향을 확인하였다. 질소 유량 90 sccm으로 제조한 TiMoN 코팅층은 TiN 코팅층과 유사한 색상을 보였다. TiMoN 코팅층의 조성을 에너지분산형 분광기(energy dispersive spectroscopy)로 분석한 결과, 타겟과 유사한 조성을 보였다. TiMoN 코팅층의 단면을 주사전자현미경으로 관찰한 결과, 주상정 형성이 확인되었으며 코팅층 표면에는 음극 아크 공정 시 발생하는 거대입자가 발견되었다. 질소 유량 50 sccm으로 제조한 TiMoN 코팅층은 약 3000 Hv의 경도 값을 보였다. X-선 분광기로 TiMoN 코팅층의 결정성을 분석한 결과, TiN과 유사한 합금상이 형성된 것을 확인할 수 있었다. TiMoN 코팅층은 TiN과 유사한 색상을 보였으며 경도는 TiN보다 높은 값을 보여 절삭공구, 금속 가공용 부품 등 고경도 코팅층으로 활용이 가능할 것으로 판단된다.

  • PDF

마이크로콤퓨터를 이용한 다변수 시스템의 적응제어에 관한 연구 (Adaptive Control of a Multivariable System Using $\mu$-Computer)

  • 김영기;변증남
    • 대한전자공학회논문지
    • /
    • 제16권5호
    • /
    • pp.27-33
    • /
    • 1979
  • 전형적인 다변수 화공정시스템을 실제로 구성하고 이 시스템에 대해 종래에 쓰이던 하드웨어 제어기 대신에 마이크로콤퓨터를 써서 제어한 실험연구의 결과를 보고하였다. 특히 시스템에 공급되는 유동의 수압이 강하함으로 인한 시스템특성의 변화에 대해서 유량계를 이용한 적응제어를 시도하여 그 제어성능이 크게 개선되도록 하였다.

  • PDF

전자기 토모그래피를 이용한 액체 금속 속도장 측정 (Measurement of velocity Pronto in Liquid Metal Flow Using Electromagnetic Tomography)

  • 안예찬;김무환;최상호
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1271-1278
    • /
    • 2004
  • In order to measure non-intrusively velocity profile in liquid metal flow, a modified electromagnetic flowmeter was designed, which was based on electromagnetic tomography technique. Under the assumption that flow is fully-developed, axisymmetric and rectilinear, the velocity profile was reconstructed after the flowmeter equation, the first kind of Fredholm integration equation, was linearized. In reconstruction process Tikhonov regularization method with regularization parameter was used. The reconstructed velocity profile had the nearly same as turbulent flow profile which was approximately represented as log law. In addition, flowmeter output fur a fixed magnet rotation angle was linearly proportional to flow rate. When magnet rotation angle was 54$^{\circ}$, axisymmetric weight function was nearly uniform so that the flowmeter gives a constant signal for any fully-developed, axisymmetric and rectilinear profile with a constant flow rate.

전자기 토모그래피를 이용한 액체 금속 속도장 측정 (Measurement of Velocity Profile in Liquid Metal Flow Using Electromagnetic Tomography)

  • 최상호;안예찬;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1749-1754
    • /
    • 2004
  • In order to measure non-intrusively velocity profile in liquid metal flow, a modified electromagnetic flowmeter was designed, which was based on electromagnetic tomography technique. Under the assumption that flow is fully-developed, axisymmetric and rectilinear, the velocity profile was reconstructed after the flowmeter equation, the first kind of Fredholm integration equation, was linearized. In reconstruction process Tikhonov regularization method with regularization parameter was used. The reconstructed velocity profile had the nearly same as turbulent flow profile which was approximately represented as log law. In addition, flowmeter output for a fixed magnet rotation angle was linearly proportional to flow rate. When magnet rotation angle was $54^{\circ}$, axisymmetric weight function was nearly uniform so that the flowmeter gives a constant signal for any fully-developed, axisymmetric and rectilinear profile with a constant flow rate.

  • PDF