• Title/Summary/Keyword: 전자개폐기

Search Result 60, Processing Time 0.03 seconds

Investigation of Electromagnetic Force for Magnetic Contactor of Railway Vehicles (철도차량용 전자접촉기 전자코일의 전자기력 특성 연구)

  • Jung, Jooyoung;Park, Ji-Won;Choi, Jinnil
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.3
    • /
    • pp.324-330
    • /
    • 2016
  • A magnetic contactor is a switching device widely used for electric circuits. For the operation of magnetic contactors, magnetic coils are essential; these coils create and interrupt the electric circuit. In this paper, the finite element analysis model was developed to reflect the experimental data, and was verified through alteration of the applied voltages and the numbers of turns. Effects of electromagnetic force on the geometrical variations of the facing poles for fixed and moving cores of two magnet coils were investigated. In addition, effects of slope and air gap size between two facing poles on the electromagnetic force were explored through the distribution of the magnetic flux density in the magnetic coils of a push-type solenoid. Through this analysis, the characteristics of the electromagnetic force against the facing poles were explored.

A Smart Window Using Intelligent Controller (지능제어기를 활용한 스마트 창문)

  • Han, Jae-Woong;Kim, Tae-Hoon;Kim, Ju-Han
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.749-751
    • /
    • 2022
  • 본 논문은 코로나19로 인해 가정에서 생활하는 시간이 길어진 현재 스마트 IoT시스템을 기반으로 각종 환경에 따라 자동으로 창문을 여닫는 "지능제어기를 활용한 스마트 창문"(이하 "윈도우 플러스")을 제안한다. 본 논문이 제안하는 주요한 특징은 다음과 같다. 첫째, 여러 가지 센서와 모터, 라즈베리파이를 이용하여 센서 입력 값에 따라 창문 개폐를 결정한다. 둘째, 안드로이드 어플리케이션과 윈도우 플러스-휴대폰 간 블루투스 통신을 이용하여 창문에 입력되는 대기 환경 수치를 실시간으로 표시한다. 셋째, 실내모드와 실외모드를 구분지어 설정할 수 있으며, 이는 사용자로 하여금 실내 대기 상태를 최적으로 만들 수 있도록 한다. 넷째, 창문의 개폐 여부를 telegram을 통해 사용자가 알 수 있도록 하며, 실내 환경의 보안성을 제공하고. 채팅을 통해 원격제어를 한다. 제안하는 시스템은 기존 수동방식의 창문으로부터 사용자의 편의성을 증가시키고, 자동 환기를 통해 코로나19의 전파를 방지하는데 도움을 줄 수 있는 "윈도우 플러스"의 개발을 목표로 한다.

Design of Integrated Control System for Combustion Type CO2 Generator with Solar Radiation Sensitiveness and Irrigation Supply (일사량 감응 및 관수공급이 가능한 연소형 CO2 발생기 통합 제어시스템의 설계)

  • Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.3
    • /
    • pp.617-622
    • /
    • 2018
  • Simultaneous control of blowers and heat exchangers affecting the air sealing and flow conditions inside the green house is essential to the management of $CO_2$ concentration. Currently, the demand for automation systems and integrated control is steadily increasing according to increasing of farm areas per person due to the reduction of agricultural population. This paper proposes the integrated control system that can control simultaneously the existing devices such as measurement switching devices which are important variables in the supply of $CO_2$, $CO_2$ generator fuel and combustion air mixture ratio(air-to-fuel ratio), and $CO_2$ supply control under internal and external conditions.

Synchronous Position Controller Design of Hydraulic Cylinders for a Sluice Gate Using Fuzzy PI (퍼지 PI를 이용한 배수갑문용 유압실린더의 위치 및 동기 제어기 설계)

  • Choi, Byung-Jae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.7 no.3
    • /
    • pp.117-120
    • /
    • 2014
  • In general a main technology of control a sluice gate is accurate synchronous position control for the two cylinders when they are moving with the sluice gate together over 10[m]. Because the nonlinear friction and the unconstant supply flow. Cylinders' displacement will be different. In this case the sluice gate may be deformed and abraded, and even the sluice gate may unable to work. In order to design the controller for this system, we designed two kinds of Fuzzy PI controllers. Fuzzy PI position controller and Fuzzy PI synchronous controller have been designed. We show some simulation results for its availability.

A Study on Optical Current Sensor and Voltage Sensor for automation of power distribution (배전자동화 개폐기 내장형 광 전류 및 광 전압 센서에 관한 연구)

  • 양승국;오상기;박해수;김인수;김요희;홍창희
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.1
    • /
    • pp.89-98
    • /
    • 2002
  • Optical current sensor and optical voltage sensor modules were designed and fabricated to improve measurement error and insulation in automatic power distributor By using Faraday effect, optical current sensor with an $\alpha$-iron core was designed and fabricated to minimize current induction of the other phase and was optimized to maintain linearity. Optical voltage sensor was fabricated owing to the pockets effect and adopted spatial electric field type because of small room in an automatic power distributor. To connect a distributor with an external terminal for signal processing, optical multi connector was designed, fabricated and tested for coupling loss and gas leakage. The linearity of optical current sensor for applied current maintains variation of smaller than 2.5% for applied current range from 20A to 700A. The linearity of optical voltage sensor was smaller than 1% for appling voltage from 6.6kV to 19.8kV. Since the measured characteristics are good, these devices can be considered as being applicable in practice.

The Development of Electronic Transformer(CT/PT) for Intelligent GIS Based on IEC 60044 (IEC 60044 기반 Intelligent GIS용 전자식 변성기 개발)

  • Kim, M.S.;Jung, J.R.;Kim, J.B.;Song, W.P.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2262-2264
    • /
    • 2005
  • 지금까지 변전소나 개폐소에서 전류, 전압을 계측하는 수단으로서 주로 철심과 권선으로 구성되어진 변류기(CT), 계기용 변압기(PT, PD)가 사용되어져 왔다. 최근, 2차측의 계측기나 보호 Relay의 Digital화가 진전되어 또한 이것을 Digital Network으로 총합한 Intelligent 변전소의 구축이 검토되어지고 있으며, Digital Network에 대응한 변성기 관련규격인 IEC 60044가 근래 제정되어짐에 따라 이에 적합한 전자식 변성기가 요구되어지고 있다. 상기와 같은 요구로 인해 당사에서는 IEC 60044를 기반으로 한 전자식변성기 Layout을 구성하였으며, CT는 검출부에 Rogowski Coil을 적용하며 그 후단에 적분기를 설치하였으며, VD는 검출부에 중간 전극을 이용해서 분압하는 방식인 Capacitive Voltage Divider를 사용하고 증폭기를 삽입하여, 각각 요구되는 전압 신호를 얻었다. 이러한 신형 CT/VD의 적용으로 종래의 CT/PT가 차지하는 공간이 필요없게 되어 컴팩트한 GIS의 구조가 가능하게 되어 있다.

  • PDF

Study on Partial Discharge Characteristics under Insulating Material of Substation Facilities (변전기기 절연매질에서 발생하는 부분방전신호 특성분석)

  • Han, Ki-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.153-154
    • /
    • 2008
  • 변전기기의 주요 절연매질인 절연유 및 $SF_6$ 가스에서 절연불량으로 부분방전이 발생할때 방사되는 전자기파 특성을 측정, 분석 하였다. 부분방전 발생기구로 부유전극을 제작하여 실험하였으며 부분 방전에 의한 전자기파 신호의 특성을 분석한 결과 변압기 주 절연물인 절연유에서 발생하는 부분방전신호가 크고 높은 주파수의 신호가 발생하였고, 가스절연개폐장치 주 절연물인 $SF_6$ 가스에서 발생하는 부분방전신호도 비교적 높은 주파수 신호가 발생하였다. 본 분석결과는 변전소 주요 설비인 변압기 및 가스절연개폐장치에서 발생가능한 절연이상을 진단하기 위한 전자기파를 이용한 부분방전 분석기술 개발에 응용할 예정이다.

  • PDF

A Research to Minimizing the Effect of Voltage Disturbances on Sensitive Electrical and Electronic Equipment (민감한 전기전자기기의 전압외란에 대한 영향 최소화 연구)

  • 윤갑구
    • Journal of the Korean Professional Engineers Association
    • /
    • v.19 no.2
    • /
    • pp.10-20
    • /
    • 1986
  • This paper describes a countermeasure of electric utilities and customer equipment in order to minimize an effect of sensitive electrical and electronic equipment on the voltage disturbances. After being studied, some schemes to solve were discovered. Firstly, in the electric utilities, the reduction of frequency and influence of voltage drop's time are not easy to realize because of the standpoint of effect and economy. Secondly, in the customer equipment, there are some equipment to minimize the voltage disturbances, Such as an UPSs, a noise suppressors and a power conditioners. One of them should be established on the computer control and automated systems, the electromagnetic switch of delay-release type should be adopted on the electromagnetic switch, the controlling circuit should be adopted on the variable speed motors which is being considered a countermeasure for a momentary under-voltage drops, the luminaire adhering a instantaneous restrike device should be adopted on the HID lamp. And also, the scheme of extending a setting time of relay on the undervoltage relay and the forming method of sequence which is automatic reclosing at this time of instantaneous suspension of an electric supply have been studied.

  • PDF