• 제목/요약/키워드: 전원설비

Search Result 709, Processing Time 0.019 seconds

A Study on the Characteristic Analysis of Hybrid Choke Coil suitable for LED-TV SMPS (LED-TV용(用) 전원장치에 적합한 Hybrid 초크 코일의 특성 해석에 관한 연구)

  • Kim, Jong-Hae;Kim, Hee-Sung;Won, Jae-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.32-43
    • /
    • 2014
  • This paper presents the intra capacitance modeling according to the winding method, section bobbin and coil structure for hybrid choke coil capable of the EMI attenuation of broad bands from lower frequency bands to higher frequency bands and high frequency type common-mode choke coil capable of the EMI attenuation of high frequency band used in the EMI Block of LED-TV SMPS. In case of high frequency type CM choke coil, it can be explained the parasitic capacitance of A type and section bobbin type winding methods among them is much smaller than the other. The first resonant frequency of the proposed CM choke coil tends to increase as the parasitic capacitance becomes small and its impedance characteristics also show improved performance as the first resonant frequency increases. In case of hybrid choke coil using rectangular copper wire, it has investigated its parasitic capacitance compared to CM choke coil of conventional toroidal type becomes small. Also it has confirmed through the experiment results that CE margin and RE margin in frequency bands 0.5MHz to 5MHz and 30MHz to 200MHz are respectively 10dB and 15dB greater than that of conventional type in case of one stage EMI filter structure adopting hybrid choke coil compared to two stage EMI Filter structure using two of each CM choke coil used in the lower and higher frequency bands or two of CM choke coil used in only the lower frequency bands. In the future, the hybrid choke coil and CM choke coil of high frequency type show it can be practically used in not only LED/LCD-TV SMPS but also several applications such as LED Lighting, Laptop Adapter, Server Power Supply and so on.

The Study of Determination to Equivalent Circuit Parameters for Single phase Induction Motor using MATLAB (매트랩을 이용한 단상유도전동기 등가회로 정수 산출에 관한 연구)

  • Lee, Byung-Sun;Kim, Yang-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.125-130
    • /
    • 2007
  • Single-phase is used widely power of field of appliance because can use commercialized power directly without power transform. Specially, because condenser nu-drive style single-phase induction motor efficiency is excellent, and most suitable in embodiment as economical. It is established true that method by crossing self-discipline and method by revolving magnetic field are interpretation of net single-phase induction motor, but method to calculate electric motor inside proper move in existent theory or method is some complex. That arbor in the law of circuit constant that combine equivalent circuit law with numerical analysis law according to development of the latest computer or microprocessor is suggested and does the calculation processing fast and correct. In this paper, measurement wishes to present method that calculate after calculate digital measurement that measures correctly and measures impossible the first and the second leakage reactance and no-load test locked-rotor test, DC test and resistance measurement of stator winding in circuit parameter calculation program that is had for MatLab program individually in single-phase power.

An Implementation of Radiologic Imaging Device of Remote Emergency Medical System (원격응급시스템의 방사선 영상장치 구현)

  • Cho, Dong-Heon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.60-65
    • /
    • 2007
  • The radiologic imaging device was implemented. It can be installed in an ambulance or used when an accident happens. After an equipment which generates X-ray generating unit with a tube in DC 12[V] had been made, a trait experiment using an oscilloscope was made. An experiment was carried out where the generated X-ray was saved as a form of a file using a digital detector. In this experiment, as a result of generating X-ray and detecting it using a digital detector, 1.67[MB]-, jpg- radical rays information could be saved. One distinct advantage of the developed radiologic imaging device is the fact that we can efficiently deal with emergency cases too far from the hospital, difficult to diagnose but treat simultaneously. By using the radiologic imaging device at the urgent scene of an accident or in a moving ambulance, we can provide the patient's X-ray information with the emergency medical specialist who is in the emergent medical center and have the patients prescribed and treated appropriately. As a result the developed emergency medical treatment can be expected.

Research on Comparison of Individual and Connecting Grounding Electrode for Potential Rise Distribution (개별 접지전극과 연접된 접지전극의 전위상승 분포 비교 연구)

  • Gil, Hyoung-Jun;Choi, Chung-Seog;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.57-62
    • /
    • 2008
  • This paper deals with a comparison of individual and connecting grounding electrode for potential rise. When a test current flowed through grounding electrode, potential rise was measured and analyzed for grounding method using a electrolytic tank in real time. In order to analyze the potential rise of grounding systems, a hemispherical water tank experimental apparatus was studied. Potential rise was measured and analyzed regarding the grounding method and distance by using this apparatus. The apparatus was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured by the horizontal moving probe of the potentiometer. The grounding electrodes were designed and fabricated with ground rods on a scale of one-eightieth. Potential rises of individual grounding electrode were higher than those of connecting grounding electrode. The distributions of surface potential are dependent on the distance from grounding electrode.

Development of the Multichannel Vibration Monitoring System (다채널 진동 모니터링 장치 개발)

  • Hong, Tae-Yong;Park, Soo-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.7
    • /
    • pp.671-676
    • /
    • 2016
  • This study is about design for the Rotational Instrument of the Industry factory which is used management safety and maintenance. We developed the multichannel vibration monitering system of the self-diagnosis for middle level CMS(Condition Monitoring System) market, and that system are new features to the expandability and flexibility. Normally one channel is used for treating one signal, but developed instrument can treat four channel with one signal processing card. One rack have redundant power supply and displace and it can check vibration measurement value in field without computer. Bearing fault detection is fundamental of vibration surveillance, but sometimes can not check with vibration velocity and acceleration. So it need the filtering and the amplitude modulation on the acceleration enveloping technology when irregular vibration is happened. We developed the vibration analysis instrument which is applied such technology. And the development prototype shows activated within the vibration error limit.

Influence of the Combustion Flames on the Flashover Characteristics of the Sphere-Sphere Air Gap (구-구갭의 섬락 특성에 미치는 연소화염의 영향)

  • Kim, In-Sik;Lee, Sang-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.44-51
    • /
    • 2005
  • In this paper, reduction characteristics of the AC and DC flashover voltage in the horizontal air gap of sphere-sphere electrode system were investigated when the combustion flame was present near the high voltage electrode. The voltage and current waveforms were measured, when the flashover is occurred, in order to examine the flashover polarity by flame. The reduction characteristics of AC flashover voltage were discussed with the thermal ionization process, the relative air density and the deflection phenomena in the shape of flames that caused by the coulomb's force. As the results of an experimental investigation, It was found that the reduction of flashover voltages in sphere-sphere system, in comparison with the no flame case, are $79.9[\%]$ for k=0, $82.9[\%]$ for k=0.5, $87.5[\%]$ for k=1.0, $85.0[\%]$ for h=0[cm], $40.8[\%]$ for h=5[cm] and $28.2[\%]$ for h=9[cm] when ac voltage is applied. The influence for thermal ionization process of the combustion flame in small scale no particular change is recognized.

Efficiency Improvement of an Electronic Ballast for HID Lamps (HID 램프용 전자식 안정기의 효율 개선)

  • 이성희;이치환;권우현
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.9-17
    • /
    • 2002
  • A high-efficiency electronic ballast for HID lamps is presented. The ballast consists of a PFC and a resonant inverter. To reduce losses of the ballast, DC link voltage should be determined by taking into account the peak voltage of lamp and the maximum flux density should be kept 0.2[T] on all of inductors. AR inductor at bridge diode is employed in order to remove currant harmonics from PFC. An inductor is connected in series with an electrolytic capacitor at DC link to reject high-frequency current. The acoustic resonance is eliminated using the stead spectrum technique. The electronic ballast for 250[W] metal-halide discharge lamp is implemented and 96[%] efficiency, no acoustic resonance and low conducted EMI level are accomplished.

The Constant Output Power Control of SSRT FB DC-DC Converter by an Improved Phase-shift Control (개선된 위상 천이 제어에 의한 소프트 스위칭 공진형 FB DC-DC 컨버터의 정출력 제어)

  • 신동률;조용길;김동완;우정인
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.5
    • /
    • pp.27-35
    • /
    • 2000
  • This paper deals with a control strategy for constant output power of SSRT(Soft Switching Resonant Type) FB(Full Bridge) DC-DC converter by an improved phase shift controller. When the FB DC-DC converter for the high density and the high effect control is operated in high speed switching, the switching loss and switching stress of the switching devices are increased. So, the soft switching method, which has the phase shift control with the digital I-PD controller, must be use in order to reduce its. And the output voltage that controlled by the digital I-PD controller tracks a reference without steady state error in variable input voltage. The validity of control strategy that proposed is verified from simulation results and experimental results by the DSP(TMS320C32).

  • PDF

Development of Electronic Limit Switch for the Drive Unit of Incore Detector System Application (노내 핵계측 계통 구동기기의 전자식 한계스위치 개발)

  • 박종범;양승권;이상효
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.1-7
    • /
    • 2000
  • In this paper, we study a cause of malfunction of switch to control drive motor in DFMS(Digital Flux Mapping System) which can measure incore neutron flux of the nuclear plant, and develope a method to solve this problem. DFMS has the type of generating contact signal by mechanical switch lever, which is operated whenever thimble detector inserted or withdrawed through thimble Guide Tube. However the characteristics of the lever tend to be changed by mechanical degrade or bad environment and the lever finally generates errotic contact signal. Therefore we installed electric coil ass'yin the outside of Guide Tube instead of mechanical switch assy's. In addition we applied resonance effect to control circuit and installed condenser in the input of power supply to protect noise and interference. After completion of this improvement, we tested this improved device repetitively under the various conditions. In conclusion, we identified the generation of the desired contact signal and the prevention of detector failure through plant surveillance test during normal plant operation.

  • PDF

A study on the haromnic attenuation of the BF Converter (BF 컨버터의 고조파 감쇠에 관한 연구)

  • 최태섭;안인수;임승하;사공석진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.8-15
    • /
    • 2000
  • In this paper, we realize the active PFC(Power Factor Correction) system of BF(Boost Forward) converter with PWM-PFM(Pulse Width Modulation-Pulse Frequency Modulation) control technique to control DC output voltage, to remove the noise like harmonics at output voltage, and to control the input current with sinusoidal wave synchronized by the source voltage.To achieve the desired load voltage and improved PFC, we first implement current shaping control at the inverting stage and make the converted output DC voltage with forward converter. After making the ratio of output voltage to current as 50V/1A and the duty ratio greater than 0.5. When input voltage is 30V and boost inductance is 1.1mH. we control the voltage changing rate according to the variation of load resistance using a PWM-PFM control technique. And finally we prove experimentally, we attenuated its harmonics and improved PF up to 0.96 using the current shaping technique.

  • PDF