• Title/Summary/Keyword: 전원설비

Search Result 710, Processing Time 0.025 seconds

Characteristics of Generated Voltage by Temperature Change of Electrical, Elecrtronic and Industrial MIM Element Using LB Ultra Thin Film (LB 초박막을 이용한 전지전자 공업용 MIM소자의 온도변화에 의한 발생전압 특성)

  • 김병인;국상훈
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.3
    • /
    • pp.80-87
    • /
    • 1997
  • As a result of experimenting the temperature characteristics of origination voltage in Al/$AL_1,O_3/PI (nL)/Au, the sample of polyimide LB film and AI/$AL_1,O_3/Cls TCNQ(lOL)/Al, the difference of work function is found between upper and lower electrodes. If polyimide LB film is accumulated with Z type or becomes imide, the polarization of the film is not made. And AI/$AL_2,O_3/C-{15}TCNQ( IOL)/ AI which is the CI5 TCNQ LB film sample doesn't show the difference of work function because it has the same upper and lower electrode and the polarization is found on the film. As a result of experiment with MIM element of LB ultra thin film, Direct current more than hun¬dreds of m V is generated and it can be used for industrial power resources in the area of electricity, electronics and information communication.

  • PDF

The Characteristics of High Ozone Concentration.Yield Multi-discharge Type Ozonizer for Water Environment Improvement (수질환경개선용 고농도.고수율 다중방전형 오존발생기의 특성)

  • Song, Hyun-Jig;Rahman, M. F.;Kim, Yeong-Hun;Kim, Geun-Young;Park, Won-Zoo;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.71-79
    • /
    • 1999
  • In this paper, high concentration.yield trulti-discharge type ozonizer( MDO ) of new discharge type using superposed silent discharge was designed and manufactured MDO can be consisted with 3 kind of superposed silent discharge type ozmizer( SDO ) in accordance with power supply method that suwlying power, which has $180[^{\circ}]$ phase difference, to 3 electrodes and amble gap. At the rroment, discharge characteristics and ozone generation characteristics of each SDO were investigated in accordance with quantity of suwlied gas, the number of SDO, and the shapes of each SDO. In result, ozone generatioo characteristics of 17185[ppm] and 783[g/kWh] were obtained, and when ozone of 17185[ppm] was in contact with dyeing water waste, decolorization characteristics was excellent, so it confinred that MDO could be used as water environment improvement facility.cility.

  • PDF

Development of an Electronic Starting Controller for Starting Motor of Packaged Power Systems (이동식발전설비의 기동전동기용 전자식 시동 제어장치 개발)

  • Kim, Jong-Su;Yoon, Kyoung-Kuk;Seo, Dong-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.700-706
    • /
    • 2012
  • The core technology of a starting device in the packaged power system is the pinion gear shifting device and to limit the initial starting voltage. Although the conventional products have been used the starting controller using mechanical contactor, these have a big problem such as the uncertainty for the start of starting motor after a pinion gear is completely shifted or the arc demage due to high current. In this study, in order to solve these problems, we designed and fabricated a new product to achieve the safety and reliability as follows: the pinion gear-shifting control circuits to eliminate the uncertainty of the start, the starting control system using semiconductor device to prevent the arc demage of contactor caused by high current, a start safety devices for soft starting of series motor. In addition, we obtained the electrical safety by separating the pinion gear control circuit and the source circuit of motor.

A Study on The MRA PWM Technique Using the Trapezoidal Waveform at Voltage Source Inverter(VSDI) (전압형 인버터(VSI)에서 사다리꼴파형을 이용한 MRA PWM 기법에 관한 연구)

  • 한완옥;원영진;이성백
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.2
    • /
    • pp.36-40
    • /
    • 1993
  • In order to improve complicated construction and complex control which are disadvantage of optimal PWM technique aimed at harmonic elimination method, this paper presented MRA(Model Reference Adaptive) PWM technique that gatmg signal of inverter is generated by comparing the reference signal with the induced feedback signal at the reference model of load. Design of controller is composed of microprocessor and analog circuit. MRA PWM technique used in the paper is able to compensate the degradation of voltage efficiency to be generated by the ratio of the output voltage to the DC supply voltage being low for using conventional sinusoidal PWM technique. When the trapezoidal signal is employed as the reference signal. the low order harmonics of line current can be reduced and the switching pattern is made by on-line computation using comparatively simple numerical analysis.

  • PDF

Implementation of a DSP Based Fuel Cell Hardware Simulator (DSP기반 연료전지 하드웨어 시뮬레이터 구현)

  • Oum, Jun-Hyun;Lim, Young-Cheol;Jung, Young-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.59-68
    • /
    • 2009
  • Fuel cell generators as the distributed generation system with a few hundred watt$\sim$a few hundred kilowatt capacity, can supply the high quality electric power to user as compared with conventional large scale power plants. In this paper, PEMFC(polymer electrolyte membrane fuel cell) generator as micro-source is modelled by using PSIM simulation software and DSP based fuel cell hardware simulator based on the PSIM simulation model is implemented. The relation of fuel cell voltage and current(V-I curve) is linearized by first order function on the ohmic area in voltage-current curve of fuel cell. The implemented system is composed of a PEMFC hardware simulator, an isolated full bridge dc boost converter, and a 60[Hz] voltage source PWM inverter. The voltage-current-power(V-I-P) characteristics of the implemented fuel cell hardware simulator are verified in load variation and transient state and the 60[Hz] output voltage sinusoidal waveform of the PWM inverter is investigated under the resistance load and nonlinear diode load.

The Ultraviolet Generation Characteristics of porcelain and Polymer Insulators by Corona Discharge (코로나 방전에 의한 자기 및 폴리머 애자의 자외선 발생특성)

  • Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Kim, Young-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.147-152
    • /
    • 2008
  • This paper describes the breakdown poperties of porcelain and polymer insulators using the UV camera. The experiment was carried out using condition of voltage at the KS C IEC 60060-1(2006). As these results, corona discharge in porcelain insulator was generated the weakness point of insulator union. And the corona discharge of polymer insulator happened in union of power source. Also, we could confirm easily weakness part of these insulators by ultraviolet image through the corona discharge. Besides, in the comparison with the exciting technique of ultrasonic detection, it confirmed that deterioration steps are corrected. These steps are possible to judge the deterioration of power facilities through reliable date. Hereafter, this study as the diagnostic technology suitable for the sites is used.

Hazards and Solutions of Loss of the PEN Conductor in TN-C-S System (TN-C-S계통에서 PEN도체의 단선고장의 위험성 및 보호대책)

  • Lee, Bok-Hee;Lee, Kyu-Sun;Ahn, Chang-Hwan;Kim, Han-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.113-120
    • /
    • 2007
  • This paper presents the electric shock hazards and solutions of loss of the combined protective and neutral (PEN) conductor in TN-C-S system. In order to mitigate the touch voltage on exposed-conductive-parts in a break in the PEN conductor, the touch voltages on exposed-conductive-parts in a break in the PEN conductor were experimentally investigated as a function of the ground resistances of the source grounding electrode and customer's additional grounding electrode. As a result, the equipotential bonding is one of important requirements for installations supplied by TN-C-S system. A solution of mitigating the touch voltages on exposed-conductor-parts caused by a loss of the PEN conductor would be the installation of the additional grounding electrode at the customer's service entrance. The ground resistance of additional grounding electrode necessary to limit the touch voltage to a safety voltage of less than 50[V] depends on the load and circuit parameters. In addition, the undervoltage sensing devices oner affordable solutions to detect a loss of the PEN conductor in TN-C-S system.

The Analysis of Effect in Order to Consider Combined Heat and Power Capacity in the Basic Plan of Long Term Electricity Supply & Demand (전력수급기본계획에 열병합발전 설비 반영시의 효과분석에 관한 연구)

  • Kim, Yong-Ba;Moon, Jung-Ho;Yeon, Jun-Hee;Jung, Hyun-Sung;Woo, Sung-Min;Kim, Mi-Ye
    • Journal of Energy Engineering
    • /
    • v.16 no.1 s.49
    • /
    • pp.22-31
    • /
    • 2007
  • This paper addresses methodology in order to consider CHP (Combined Heat and Power) capacity in the Basic Plan of Long Term Electricity Supply & Demand and presents effects on it. The method performs state in extent that do not change maximum in the Basic Plan of Long Term Electricity Supply & Demand. For analysis that occurs some advantage this method compares with Basic Plan of Long Term Electricity Supply & Demand. It includes EES (Expected Energy Served), Fuel consumption, amount of $CO_{2}$ emission reduction.

Survey on the Malfunction of MCCB and ELB in Private Electrical Facilities (자가용 수용가에서 배선용 및 누전차단기 오동작에 대한 조사연구)

  • Yoo, Jae-Geun;Lee, Sang-Ick;Jeon, Jeong-Chay
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.87-93
    • /
    • 2005
  • Recently, nuisance tripping or malfunction of MCCB(Melded Case Circuit Breaker) and ELB(Electrical Leakage Breaker) is being increased according as load circuits and equipments of electrical customers are various and complicated, but investigation of actual conditions on malfunction of MCCB and ELB was not implemented This paper investigated causes and influences of malfunction of MCCB and ELB by making up a question to electrical safety managers of two hundred and eighteen private electrical facilities. The results show that users above $70[\%]$ experienced malfunction of MCCB and ELB, and causes of malfunction are in order aging(above $25(\%)$), nuisance tripping $(above\;22(\%))$, goods badness$(above\;20(\%))$, abnormal power like as harmonics$(above\;20(\%))$ and others $(about\;9(\%))$. Also, second damages due to failure of MCCB and ELB are in order goods production, equipment trouble, information loss, business and operation interrupt, and others. The results of this study can be used in making decisions regarding causes of MCCB and ELB trip.

Analysis on Momentary Voltage Dips with the Interconnection Operation of Utility-interactive Cogneration Systems Considering Their Generator Type (발전기 형태를 고려한 열병합발전시스템의 배전계통 연계운전시의 순시전압변동 해석)

  • 최준호;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.23-30
    • /
    • 2000
  • Cogeneration systems are seen as a significant innovation for dispersed energy generation since they are both environmentally friendly and has comparatively high degrees of efficiency. It is especially suited for the decentralized provision of electricity and heat. However, it causes operational problems such as voltage regulation, voltage variation, protection and safety. Especially, it is expected that the interconnection/disconnection operation of cogeneration system has an effect on distribution voltage regulation and variation. Recently, with the increased use of customer-owned computers and other sensitive electronic equipment, electric power quality has become an important concerns. Therefore, the voltage quality problems with cogeneration system should be investigated because the voltage quality is an important part of electrical power quality. In this paper, the momentary voltage dips associated with the interconnection/disconnection operation of cogeneration system are analyzed, including restraint solutions at the customer level. In addition, the unit capacity of cogeneration systems per feeder are evaluated from the view point of momentary voltage variations. The results of this paper are useful analysis data for interconnection standards/guidelines of cogeneration systems and dispersed generation (DG)

  • PDF