• Title/Summary/Keyword: 전용 CAD/CAM

Search Result 32, Processing Time 0.03 seconds

Rehabilitation of fully edentulous patient using Ceramill full denture system (FDS) (Ceramill full denture system을 이용한 무치악 환자의 양악 총의치 제작)

  • Lee, Younghoo;Kwon, Kung-Rock;Pae, Ahran;Noh, Kwantae;Paek, Janghyun;Hong, Seoung-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.232-237
    • /
    • 2019
  • CAD/CAM technology has already been used in most areas of prosthetics. The range of CAD/CAM application in denture fabricating process has been gradually increasing since the CAD/CAM technology was introduced for the fabrication of complete dentures in 1994. This paper describes a technique that combines conventional and CAD/CAM technology for the fabrication of complete dentures: the master casts from a conventional impression techniques were scanned first, and the wax denture was fabricated using Amann Girrbach's Ceramill full denture system (fds). The purpose of this paper is to introduce the case in which making an esthetically and functionally satisfied denture in shorter time is possible with CAD/CAM technology.

Design of a C-based Independent Motion Controller using CAD&CAM (CAD&CAM을 활용한 C기반 독립형 모션 제어기 설계)

  • Kim, Sam-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.5
    • /
    • pp.105-110
    • /
    • 2016
  • Recently, as to changes in the paradigm of domestic manufacturing CNC industry, the application of advanced technologies in machine tools are actively being pursued. IT in responsible for controlling it is the most important part in the field of CNC. The biggest lack of the necessary expertise in the field of motion control in CNC is coding G-Code in setting adjust coordinate directly and convert it through expensive foreign s/w rather than using windows language in PC based controller. In this paper, We implemented G-Code convert program that is change various type of CAD data to G-Code data and CAD/CAM application program and developed exclusive motion controller which is to run a robot directly using changed data.

Mandibular implant-supported overdenture using CAD-CAM Konus type attachment: A case report (CAD-CAM Konus type 부착장치를 이용한 하악 임플란트 피개의치 보철수복 증례)

  • Park, Jong-Hee;Kim, In-Ju;Kim, Kyoung-A;Song, Kwang-Yeob;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.259-266
    • /
    • 2016
  • In edentulous mandible, implant supported overdenture was considered as a first treatment option. Konus type attachment supplies rigid support and cross arch stabilization so that more favorable force transmission and distribution can be attained. In the dentistry, computer aided design-computer aided manufacturing (CAD-CAM) system makes it possible to fabricate restorations with high precision and effectiveness. Recently, Palladium-silver (Pd-Ag) alloy which is millable has been developed. This article presents that application of CAD-CAM Konus type attachment can be provide satisfactory stability and function on four-implant supported mandibular overdenture.

The Development of Exclusive CAD/CAM System for Impeller Blades Formed by Ruled Surface I(A Study on the Modeling) (Ruled Surface로 형성된 임펠러 블레이드 전용 CAD/CAM 시스템 개발 I (모델링에 관한 연구))

  • ;;;;;;Yu-Ge Dong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.6
    • /
    • pp.71-77
    • /
    • 2001
  • We have developed the exclusive CAD/CAM system for the machining of impeller blades. This study is about the mod-eling method for the effective machining of impeller blades farmed by ruled surface. As the impeller is consisted of boss part and blade part, the boss is modeled by rotational surface of hub curve on z-axis and the blade is described by ruled- surfaces between hub curve and shroud curve. This modeling process can be carried out on the software developed in this study. And, the developed software can describe the impeller as a solid model through interface with Solid-Works soul- ware. The developed software containing the interface method proposed in this study was very effective fur impeller modeling.

  • PDF

A CAD/CAM System for Steam Paths of Turbine Generators (터빈발전기의 Steam Path 전용 CAD/CAM시스템)

  • Kim Y. I.;Kim D. S.;Jun C. S.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.10 no.4
    • /
    • pp.254-261
    • /
    • 2005
  • The purpose of this research is to develop a method for cutting non-circular holes on a bent thick plate. Generally in order to cut the holes on the large plates, a special-purpose 5-axis machine is needed. However, such a machine is unavailable in most of the machine shops. This paper provides a description of such a method that utilizes a general-purpose 5-axis water-jet machine in place of the special-purpose machine: First, the bent piece is transformed into a flat plate, where the shape of the holes is reconstructed by considering deformation during bending. Then, after a 5-axis NC data is generated, the holes on the flat plate are cut using the 5-axis water-jet machine. The final step is to return to its, original shape by bending the plate with its newly-cut holes. The proposed methodology is implemented as a dedicated system by customizing a commercial CAD/CAM system. Some illustrations are provided throughout the paper in order to show the validity of the proposed methods and the developed system.

A study on marginal fit of the ceramic-based hybrid resin restoration for dental CAD/CAM systems (치과용 CAD/CAM 전용 세라믹기반 하이브리드 레진 수복물의 변연 적합 연구)

  • Jeong, Chang-Seop;Park, Jong-Kyoung
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.228-233
    • /
    • 2020
  • Purpose: This study aimed to assess and compare the marginal fit of ceramic-based hybrid resin restoration (HYB) and zirconia restoration (ZIR) for dental computer-aided design/computer-aided manufacturing systems. Methods: A stainless steel master model was produced. The impression was first made with silicone, and then stone working models were produced. A total of twenty restorations were fabricated with two different materials: ZIR and HYB. The silicone film thickness of the marginal gap was measured using a digital microscope; digital photos were taken at a magnification of ×160, and then analyzed using a measurement software. The values of the result were evaluated with the independent-sample t-test (α=0.05). All statistical analyses were performed with a statistical software. Results: The mean values for the marginal gap was 37.14±2.96 ㎛ for HYB, compared with 40.37±5.26 ㎛ for ZIR. No significant difference was found between ZIR and HYB (p=0.107). Conclusion: As a result, the marginal fit of the restoration fabricated using the hybrid resin was better than that of the restoration fabricated using zirconia. Also, the marginal fit of all groups was below the clinical acceptable range of 120 ㎛. Thus, HYB for dental CAD/CAM system in this study is expected to be suitable for clinical use in dentistry.

A study on the post-processing functions in a polygon-based reverse engineering system (폴리곤 기반 역공학 시스템의 후처리 기능에 관한 연구)

  • Park, Jin-Pyo;park, kwang-Hyun;Choi, Young;Jun, Yong-Tae;Rho, Hyung-Min
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.41-44
    • /
    • 2001
  • In reverse engineering, the whole surfaces of the three-dimensional(3D) product are measured using 3D positional scanners. The raw triangle meshes constructed from a scanned point set are not well suited for direct use in the downstream activities. This is because the amount of triangle meshes may be very large(from millions to hundreds of millions) and usually distorted by scanning error. Furthermore, the triangle meshes may contain several holes that must be filled. Thus, several solutions have to be addressed and implemented before a complete CAD models can be acquired. This paper discusses on the algorithms of decimation, smoothing, and hole-filling that are crucial to refine the triangle meshes. Several examples are also given and discussed to validate the system.

  • PDF

Differences in retention of the reduction direction depending on dimensions and design CAD/CAM zirconia abutment for implant (Implant에 사용되는 CAD/CAM 전용 zirconia abutment의 표면적과 디자인에 따른 유지력 차이)

  • Nam, Taeg-Mo;Kim, Han-Gon;Kim, Byung-Sik;Lim, Si-Duk
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.317-325
    • /
    • 2010
  • Purpose: The aim of this study is to make some basic materials to find retention force difference based on the total height of CAD/CAM zirconia abutment used for implant, retention force difference based on how to regulate the height of the abutment, retention force difference based on the size and retention force difference based on the design group. Methods: The retention force was measured by being pulled at the speed of 1mm/min after being combined with zirconia block and abutment using Temp-BOND of Kerr. The experiment was done at the research lab of OSTEM in Busan by useing UNIVERSAL TESTING MACHINE on March 3rd, 2010. Results: After analysing the total height and the retention force, p-value had minor difference by 0.01 statistically. Namely, 3mm, 4mm, 5mm had the retention force difference and we could see retention force difference on 3mm and 5mm at the post test. After analyzing how to regulate the height and retention force, p-value had minor difference by 0.000 statistically. Namely, 1mm and 2mm had the retention difference and we could see that 1mm and 2mm with the total height had retention difference. After analyzing the retention force based on the size, p-value had minor retention force difference by 0.000 statistically. Namely, 7 different size had retention force difference and we could see the size 21.9mm, 32.9mm, 32.9mm, 38.4mm, 48.9mm and 54.9mm had retention force difference. Conclusion: Namely 9 different design group had retention difference and we could see that 9 design group with 5.6.7.8 design group and 9 design group with 1.2.3.4. design group had retention force.

Comparative Study of the Surface Roughness of Working Models Fabricated by Dental CAD/CAM Scannable Stone and Type IV Gypsum Products (치과용 캐드캠 스캔전용 석고와 Type IV 석고로 제작된 작업모형의 표면조도 비교 연구)

  • Kim, Sa-Hak;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.14 no.4
    • /
    • pp.455-460
    • /
    • 2014
  • This study compared the surface roughness and surface characteristics between a type IV stone and scannable stone. Materials used were a type IV stone, two different kind of scannable stone. Ten specimens per experimental group were prepared according to manufacturer's direction. Surface roughness of specimen was measured using profilometer. The measurement was based on the standard of Japanese Industrial Standards 1994. The mean and standard deviations of each reference point were analyzed using one-way ANOVA and Scheff$\acute{e}$ post hoc test. The program used to handle statistical analysis was SPSS 20.0 and the significance level was set at 0.05. The difference of surface roughness was statistically significant in order of Scannable Stone $10.07{\pm}0.02{\mu}m$, Scannable Stone $20.08{\pm}0.03{\mu}m$, Type IV $0.10{\pm}0.04{\mu}m$. These results will have to be confirmed in further clinical application researches.

Tool Path Generation of a Die Cavity Defined by Sculptured Surfaces (자유곡면으로 이루어진 Cavity의 가공경로생성)

  • Jun, Yong-Tae;Park, Se-Hyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.3
    • /
    • pp.161-167
    • /
    • 1993
  • This paper deals with a new method for the machining of a die cavity defined by sculptured surfaces. In machining die cavities or pockets, process planners have been faced with some troulbes. One of the troubles ius to rebove a great deal of material within a given boundary while avoiding cutter interference. Cutter interference is a ciritical problem in NC machining of a die cavity. Even though this cavity machining has been implemented in many CAM systems, most of them can handle limited shapes of cavities or pockets. In this paper, a procedure has been developed to machine die cavity or pocket of a sculptured surface. The offset surfaces of the part surfaces and boundary surfaces are determined to calculate the intersection curves. These intersection curves form a FACE on the part surface, and the interference free tool pathe is generated by eliminating the points outside the FACE when computing the cutter contact (CC) data. Additionally, the cutter location (CL) data obtained from the CC data convert to an NC data. The NC data generated through this algorithm are verified on the CINCINNATI milling machine. A propotype die cavity machining system has been implemented in FORTRAN language and FIGARO graphics library on IRIS workstation.

  • PDF