• Title/Summary/Keyword: 전완부

Search Result 38, Processing Time 0.025 seconds

Reconstruction of the Extremities with the Dorsalis Pedis Free Flap (족 배 유리 피부판을 이용한 사지 재건술)

  • Lee, Jun-Mo;Kim, Moon-Kyu
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.77-83
    • /
    • 1999
  • The skin on the dorsum of the foot is a source of the reliable thin and sensory cutaneous free tissue transplantation with or without tendon, bone and joint. A composite flap with attached vascularized tendon grafts for the combined loss of skin and tendon on the dorsum of the hand and foot offers an immediate one stage solution to this problem. The flap provides a very durable innervated tissue cover for the heel of the foot and the dorsum of the hand and an osteocutaneous transfer combined with the second metatarsal. The major dorsalis pedis artery is constant in size, but the first dorsal metatarsal artery is variable in size and location. The dorsal surface of the foot receives sensory innervation through the superficial peroneal nerve and the first web through the deep peroneal nerve. Authors had performed 5 dorsalis pedis free flap transplantation in the foot and hand at Department of Orthopedic Surgery, Chonbuk National University Hospital from August 1993 through August 1997 and followed up for the period of between 19 and 67 months until March 1999. The results were as follows 1. 5 cases dorsalis pedis free flap transfer to the foot(4 cases) and the hand(1 case) were performed and the recipient was foot dorsum and heel 2 cases each and hand dorsum 1 case. 2 All of 5 cases(100%) were survived from free flap transfer and recipient artery was dorsalis pedis artery(2 cases), anterior tibial artery(1 case), posterior tibial artery(1 case) and ulnar artery(1 case) and recipient veins were 2 in number except in the hand. 3. Long term follow up of the exterior and maceration was good and sensory recovery was poor 4. Donor site was covered with full thickness skin graft obtained from one or both inguinal areas at postoperative 3rd week and skin graft was taken good and no morbidity was showed.

  • PDF

Fractures & Dislocations Related to Middle and High School Taekwondo Athletes in Competition (중.고교 태권도 선수의 경기 중 발생한 골절과 탈구)

  • Kim, Yeob;Kim, Chang-Yoon;Yeon, Tae-Hyun;Shim, Hee-Jong;Park, Sung-Min;Bae, Byung-Jo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Purpose: We intended to classify the pattern and to seek the cause of fractures and/or dislocations related to middle and high school Taekwondo athletes in competition and try to get the ways for preventing them. Materials and Methods: We studied 50 fractures and dislocations of the athletes in competition, which were surveyed in 2005-2007 national middle and high school Taekwondo tournament annually. We analyzed the type and the cause of the injury, performed survey at postinjury l year in 32 cases, sought proper treatments and methods for prevention. Results: The 26 cases (52%) of foot fracture, 15 cases (30%) of hand fracture and 9 cases (18%) of forearm fracture are occurred in this study. The 9 cases (28%) of satisfaction in treatment, 15 cases (47%) of average and 8 cases (25%) of dissatisfaction are surveyed in the 32 cases. The causes of dissatisfaction are lack of rest (7 cases), excessive training (5 cases), immoderate participation of match (6 cases) and the others. The athletes were returned to the match before complete recovery in 21 cases (67%). Conclusion: The causes of fractures and dislocations in middle and high school Taekwondo athletes were stroke on upper and lower extremities and high-speed hyperflexion injury that was occurred during spraining of great toe on the floor. We consider that the athletes need the development of effective protector, improvement of equipment in stadium and enough rest and education.

  • PDF

The Heel Reconstruction by Microsurgery (미세수술을 이용한 발뒤꿈치 재건)

  • Lee, Kwang-Suk;Huh, Chang-Young;Kim, Hak-Yoon;Suh, Jeong-Dae
    • Archives of Reconstructive Microsurgery
    • /
    • v.3 no.1
    • /
    • pp.24-31
    • /
    • 1994
  • The heel, with its specialized fat for shock absorption at heel strike and large surface area for balance and weight bearing, is a important component of normal ambulation. Despite of distinguished improvement in the field of microsurgical free flaps, the choice of reconstruction of the heel has been remained controversial. We reviewed 22 cases of the heel reconstruction using vascularized free flaps from January, 1980 through May, 1993 at the Department of Orthopedic Surgery of Korea University Hospital. The results were as follows: 1. The etiology was traumatic in 21 cases, and chronic ulceration due to burn in 1. 2. The arteries used in free flaps were 11 dorsalis pedis arteries, 2 deep circumflex iliac arteries, 2 supeficial iliac arteries, 2 branches of lateral femoral circumflex iliac arteries, 2 radial arteries, and 3 thorcodorsal arteries. 3. The mean size of the vascularized bone was $4.5cm{\times}3.5cm$, and that of skin flap was $12.1cm{\times}9.2cm$. 4. Of the 22 cases, 19 had a successful outcome and 3 in failure, the causes of failure were thrombosis and infection.

  • PDF

Simultaneous Anterior and Posterior Interosseous Nerve Syndrome Following Shoulder Arthroscopy in the Lateral Decubitus Position - Case Report - (측와위로 시행한 견관절 관절경 후에 동시에 발생한 전방 및 후방 골간 신경 증후군 - 증례보고 -)

  • Seo, Jae Sung;Kim, Jee Hoon;Kang, Dong Hwa
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.148-152
    • /
    • 2013
  • We report a case of simultaneous anterior and posterior interosseous nerve syndrome in association with shoulder arthroscopy. Shoulder arthroscopy was performed in a 45-year-old male patient with left shoulder instability. In the right lateral decubitus position, under general anesthesia, traction was applied with elbow extension for 2 hours. One week after surgery, the patient revisited the clinic for weakness of the flexor of the thumb, index finger, and extensor of the fingers. Recovery was not achieved after four months of observation. Therefore, nerve exploration was performed in the anterior and posterior interosseous nerve and hourglass-like fascicular constriction was detected in the posterior interosseous nerve. The area of constriction was removed and epineural neurorrhaphy was performed. Three months after exploration, the extension function of the fingers was recovered. Recovery was achieved gradually, and, five months after nerve exploration, the symptoms were completely recovered. Simultaneous anterior and posterior interosseous nerve syndrome following shoulder arthroscopy is rare. However, it could occur due to the traction and position of the patient. Thus, the operator should be careful of traction and position of the patient.

Development of Elbow Joint X-ray Examination Aid for Medical Imaging Diagnosis (의료영상 진단을 위한 팔꿉관절 X-선 검사 보조기구 개발)

  • Hyeong-Gyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.127-133
    • /
    • 2024
  • The elbow joint is made up of three different bones. X-rays or other radiological exams are commonly used to diagnose elbow injuries or disorders caused by physical activity and external forces. Previous research on the elbow joint reported a new examination method that meets the imaging evaluation criteria in the tilt position by Z-axis elevation of the forearm. Therefore, this study aims to design an optimized instrument and develop an aid applicable to other upper extremity exams. After completing the 2D drawing and 3D modeling design, the final design divided into four parts was fabricated with a 3D printer using ABS plastic and assembled. The developed examination aid consists of a four-stage Z-axis elevation tilt angle function (0°, 5°, 10°, and 15°) and can rotate and fixate 360° in 1-degree increments. It was designed to withstand a maximum equivalent stress of 56.107 Pa and a displacement of 1.6548e-5 mm through structural analysis to address loading issues caused by cumulative frequency of use and physical utilization. In addition to X-ray exams of the elbow joint, the developed aid can be used for shoulder function tests by rotating the humerus and also be applied to MRI and CT exams as it is made of non-metallic materials. It will contribute to the accuracy and efficiency of medical imaging diagnosis through clinical applications of various devices and medical imaging exams in the future.

Comparative study between proportional method and directional method in locating acupoints at forearm (전완부(前腕部) 경혈(經穴) 취혈(取穴)에서 골도분촌법(骨度分寸法)과 일부법(一夫法)의 비교(比較) 연구(硏究))

  • Park, Hi-Joon;Chae, Youn-Byoung;Cha, Wung-Seok;Park, Jong-Bae;Lee, Hye-Jung;Lee, Hyang-Sook;Yin, Chang-Sik;Koh, Hyung-Kyun;Kim, Su-Young;Choe, Il-Hwan;Kim, Kang-Sik;Moon, Jung-Bae;Bae, Ki-Tae;Rheu, Kyoung-Hwan;Yook, Keun-Yung;Jeong, Byeong-Ju;Sohn, In-Chul;Lim, Sabina
    • Korean Journal of Acupuncture
    • /
    • v.21 no.4
    • /
    • pp.31-41
    • /
    • 2004
  • Background : The cun measurement system, an essential and convenient method in locating acupoints, has been widely used in the practice of acupuncture. However, traditional cun measurement has been criticized for its lack of reliability. Objectives : The purposes of this study are to determine if one cun measured by the directional methods have a consistency with that of proportional methods and to investigate which factors are related with these differences, especially in forearm. Methods : The distance between the elbow crease and the wrist crease of forearm was compared to a reference value of one cun obtained by the directional method. In this method, one cun is one third of the distance between index finger and small finger of a subject, measured at proximal interphalangeal joint. In addition, to investigate the factors influencing the differences between these two methods, we measured the height and body weight and calculated body mass index (BMI). Finally we analyzed the factors correlated with these lengths by linear regression test. Results : The results showed that one cun obtained by the directional methods were significantly different from one cun by the proportional methods in forearm. It was demonstrated that the length acquired with the directional method was more correlated with body weight and body mass index, while the length obtained by the proportional method was more correlated with the height. Conclusion : These findings suggest that the directional method is less likely dependable in locating acupoints than the proportional method because the influencing factors are different.

  • PDF

Limb Salvage in the Treatment of the Upper Extremity Bone Tumors (상지에 발생한 악성 및 침윤성 양성골종양에 대한 사지 구제술)

  • Hahn, Soo-Bong;Shin, Kyoo-Ho;Kim, Bum-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.2
    • /
    • pp.154-163
    • /
    • 1995
  • With the development of anticancer chemotherapy and improved radiographic imaging studies, limb salvage operation became possible in the treatment of malignant and aggressive benign tumors. High grade sarcomas of the shoulder or the upper extremity can be surgically treated with a forequarter amputation, shoulder disarticulation or limb salvage surgery such as Tikhoff-Linberg procedure, segmental resection and replacement with endoprosthesis, segmental resection and replantation, or segmental resection and free vascularized bone graft. Among them the limb salvage surgery showed not only preservation of the remained upper extremity but also the excellent functional results. When comparing amputation and limb salvage operation while performing anticancer chemotherapy in both cases, 5 year survival rate, local recurrence, and distant metastasis did not show much difference. We studied 13 cases of limb salvage for the malignant and aggressive benign bone tumor of the upper extremity from March 1986 to December 1993 at Severance hospital. The summarized results were as follows. 1. There were 21 cases of malignant bone tumors and 5 cases of benign aggressive ones. 2. Of the 26 cases of malignant and benign aggressive bone tumors, limb salvage procedures such as Tikhoff-Linberg operation(8 cases), endoprosthetic replacement(2 cases), segmental resection and replantation(2 cases), and segmental resection and free vascularized fibular graft(l case) were done in 13 cases. 3. In 13 patient on whom the limb salvage procedure was performed, there were 3 osteosarcomas, 4 chondrosarcomas, 3 giant cell tumors, 1 Ewing's sarcoma, 1 leiomyosarcoma and 1 chondroblastoma. 4. In 13 patients, there was no local recurrence nor distant metastasis except one who had a segmental resection of the entire humerus part including glenoid and then postoperative anticancer chemotherapy for the treatment of the Ewing's sarcoma of the entire shaft of the humerus with pathological fracture. Local recurrence occurred 2 years and 6 months postoperatively in this Ewing's sarcoma patient, so forequarter amputation was performed and the irradiation and the anticancer chemontherapy were performed, but multiple bony metastasis developed and died of the disease 22 months after local recurrence. 5. The patients were followed-up for I year to 7 years and 5 months(average 4 years 5 months). 6. In 8 cases in which Tikhoff-Linberg procedure was performed, the function of the hand was almost normal. 7. Segmental resection and endoprosthetic replacement was performed in 2 cases, and the function of the remained upper extremity was good with no evidence of aseptic loosening or nerve palsy. 8. In 1 case of segmental resection and free vascularized fibular graft for the patient of the chon drosarcoma in the humerus, the function of the shoulder, elbow and hand was nearly normal. 9. In I case of leiomyosarcoma which involved both forearm muscles and bone near wrist joint, segmental resection and replantation was performed, and the patient has useful hand function.

  • PDF

Endoscopic Carpal Tunnel Release Using Single Portal Technique (단일 입구를 이용한 내시경적 수근관 감압술)

  • Cheon Sang-Jin;Kim Hui-Taek;Suh Kuen-Tak;Suh Jeung-Tak;Yoo Chong-Il
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.159-165
    • /
    • 2000
  • Purpose : Endoscopic carpal tunnel release technique was developed and has being used to decrease postoperative morbidity and complications. The purpose of this study was to evaluate the clinical results and clinical usefulness of endoscopic carpal tunnel release using single portal technique. Methods and Materials : 18 carpal tunnel syndrome patients who were diagnosed by means of clinical symptoms, physical examination, and electrodiagnostic study had endoscopic carpal tunnel release using single portal technique with about 1 cm oblique wrist incision on 30 hands. And then they were followed-up and reviewed in the same way. Late results of operation were analysed by grading system according to patient's own assessments of relief of symptoms at the final fellow-up. The follow-up period ranged 6 to 13 months from surgery. Results : There were postoperative improvements with respect to clinical symptoms, physical examination, and electrodiagnostic study. 23 of 30 hands$(76.7\%)$ had complete resolution of symptoms. 27 hands$(90\%)$ were able to return to normal activities and work within 6 weeks, and 30 hands$(100\%)$ returned within 8 weeks. In grip strength study, 29 hands$(96.6\%)$ regained preoperative strength in 6 months. 12 of 22 hands$(55\%)$ had improvement with respect to thenar atrophy within 6 months. Late results were as follows . 23 hands$(76.7\%)$ was graded as excellent, 6 hands$(20\%)$ graded as good and 1 hand$(3.3\%)$ graded as fair, and there was no poor result. Conclusion : We think that endoscopic carpal tunnel release with single portal technique is technically safe and simple, if the surgeon takes step to stay within the safety zone based on local anatomy and selects an appropriate patient and that endoscopic carpal tunnel release does have advantages over open release. We agree that the surgeon must be prepared to perform an open technique, if technical difficulties arise, difficulty in introducing the device into the carpal tunnel is encountered, or the transverse fibers of the transverse carpal ligaments are not clearly seen.

  • PDF