• 제목/요약/키워드: 전열촉진관

검색결과 35건 처리시간 0.018초

수평 원형전열관의 핀효과에 의한 응축 및 비등 열전달촉진에 관한 연구 (2)-튜브외부 응축- (A Study on the Improement of Condensation and Boiling Heat Transfer on Horizontal Tube by Fin Effect(ll)-Shellside Condensation-)

  • 한규일;조동현
    • 대한기계학회논문집
    • /
    • 제18권5호
    • /
    • pp.1275-1287
    • /
    • 1994
  • Heat transfer performance improvement by fin and grooves is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapezoidal shaped integral-fins having fin densities from 748 to 1654 fpm and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also tested for comparison. R-11 condenses at saturation state of $32^{\circ}C$ on the outside tube surface cooled by inside water flow. All of test data ate taken at steady state. Beatty and Katz's, Rudy's and Webb's theoretical models are used to predict the R-11 condensation coefficient of tubes having 748, 1024 and 1299 fpm. The predicted value by Betty and Katz's model is within 10% of experimental values in this study at fpm<1024 and Rudy's model predicted the experimental data at fpm>1024 within 15%. The tube having fin density of 1299 fpm and 30 grooves has the best overall heat transfer performance. This tube shows the overall heat transfer coefficient of 11500 $W/m^{2}K$,/TEX> at coolant velocity of 3.0m/s.

응축용 특수 전열관의 열전달 특성에 관한 연구 (Experimental Study on Condensation Heat Transfer Characteristics of Special Heat Transfer Tubes)

  • 한규일;박종운;권영철;조동현
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.827-835
    • /
    • 2001
  • In this study, condensation heat transfer characteristics were conducted with special heat transfer tubes of SH-C type. Experiments were carried out the saturated vapor temperature of 334K and the wall subcooling of 1.5-4.5K. The refrigerant was R-113 and the enhanced tubes used in the present study were SH-CDR, SH-CYR and SH-CHR. The experimental results showed that the condensation heat transfer coefficients of SH-C type tubes were about 23-66% higher than those of a low integral-fin tube. It was visualized that the condensed liquid on the outer surface of SH-C type tubes flowed continuously down unlike a low integral-fin tube and a plain tube, due to a 3-D extending fin on the outer surface of SH-C type tubes. As a result, the thermal resistance of the condensed liquid decreased and the heat transfer coefficient increased. Also, the enhancement ratio of SH-CDR tube was the highest, and it was about 9-11 times as compared to that of a plain tube.

  • PDF

소구경 전열관 내의 열전달촉진 형상변화에 따른 열전달 및 압력강하 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of the Heat Transfer and the Pressure Drop inside the Small Diameter Tube with the Heat Transfer Enhancing Geometry)

  • 박찬우;진성민;정종수
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.297-303
    • /
    • 2006
  • Friction and heat transfer coefficients were measured inside the corrugated tube using water as the working fluid. The test is performed for 16 tubes which outer diameter of tubes are 12.7 mm. These specifications are 4 indentation depths and 4 indentation pitches, respectively. The range of the water velocity inside the tube is from 0.5 to 3.0 m/s (8,500

낮은 유량에서 외경 9.5 mm 평활관과 마이크로핀관 내 R-404A 증발 열전달 및 압력 손실 (Evaporation Heat Transfer and Pressure Drop of R-404A at Low Flow Rates in 9.5 mm O.D. Smooth and Microfin Tubes)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제19권6호
    • /
    • pp.27-36
    • /
    • 2018
  • 그간 마이크로핀관 내 증발 열전달 및 압력 손실에 대하여 다수의 연구가 수행되었다. 하지만 대부분의 연구는 에어컨이나 히트 펌프에 사용되는 냉매에 대하여 수행되었고 R-404A에 대해서는 매우 제한된 연구만이 존재한다. R-404A는 근공비혼합냉매로 오존층 파괴와 관련하여 R-502를 대체하여 주로 저온 냉동, 냉장에 사용되고 있다. 본 연구에서는 낮은 질량유속 ($80kg/m^2s$에서 $200kg/m^2s$)에서 외경 9.5 mm 마이크로핀관 내 R-404A 증발 열전달 실험을 수행하였다. 또한 비교를 위해 외경 9.5 mm 평활관에 대한 실험도 수행하였다. 실험 결과 마이크로핀관의 전열촉진비는 질량유속이 증가할수록, 열유속이 감소할수록 증가하였다. 이러한 현상은 마이크로핀에 의한 대류 열전달의 증가와 열유속의 상대적 기여에 의한 것으로 판단된다. 또한 실험 범위에서 마이크로핀관의 마찰손실이 평활관의 마찰손실보다 다소 (최대 28%) 크게 나타났다. 기존 상관식은 저유량 R-404A 열전달계수 및 압력손실을 적절히 예측하지 못하는데 이는 본 실험 범위가 기존 상관식의 범위 밖에 있기 때문으로 판단된다.

낮은 유량에서 외경 7.0 mm 마이크로핀 튜브 내 R-410A 증발 열전달 및 압력 손실 (Evaporation Heat Transfer and Pressure Drop of R-410A in a 7.0 mm O.D. Microfin Tube at Low Flow Rates)

  • 김내현
    • 대한기계학회논문집B
    • /
    • 제39권9호
    • /
    • pp.761-772
    • /
    • 2015
  • 가정용 에어컨이나 히트 펌프에 외경 7.0 mm 마이크로핀 튜브가 널리 사용되고 있다. 한편 에어컨이나 히트펌프의 부분 부하 운전시 질량유속은 수십 $kg/m^2s$에 불과하다. 하지만 7.0 mm 튜브에 대한 기존 연구들은 질량유속 $100kg/m^2s$ 이상에서 수행되었다. 본 연구에서는 낮은 질량유속 ($50kg/m^2s$에서 $250kg/m^2s$)에서 외경 7.0 mm 마이크로핀 튜브 내 R-410A 증발 열전달 실험을 수행하였다. 실험 중 포화온도는 $8^{\circ}C$, 열유속 $4.0kW/m^2$으로 유지하였다. 비교를 위해 외경 7.0mm 평활관에 대한 실험도 수행하였다. 실험결과 마이크로핀 튜브의 전열촉진비는 질량유속이 감소할수록 증가하다 $150kg/m^2s$를 기점으로 감소함을 보였다. 이는 마이크로 핀튜브 내 유동이 환상류에서 성층류로 변화하기 때문이다. 실험 범위에서 마이크로핀 튜브의 마찰손실과 평활관의 마찰손실은 거의 같게 나타났다. 실험데이터를 기존 상관식의 예측치와 비교하였다.