• Title/Summary/Keyword: 전여과

Search Result 243, Processing Time 0.034 seconds

A Study on the Regeneration of SCR Catalyst Deactivated by Unburned Carbon Deposition (탄소침적으로 피독된 탈질 촉매의 재생에 관한 연구)

  • Moon, Seung-Hyun;Lee, Seung-Jae;Ryu, In-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.928-935
    • /
    • 2010
  • A bag filter system was partially burnt down during a trial run of waste wood incineration boiler. This brought about unburned hydrocarbon which caused a rapid deactivation of low temperature SCR catalyst set up in two stage after the bag filter. The deactivated catalyst was investigated in order to trace the origin by several characterization methods such as XRD, EDX, BET, TGA, SEM. The deactivated catalyst was regenerated by different methods such as acid washing, water washing in ultrasonication, and calcination treatment under air condition. It is found the calcination treatment under air condition at $450^{\circ}C$ for 2 hours to be the best regeneration method. The catalytic activity was measured in the form of 2 cm ${\times}$ 2 cm ${\times}$ 10 cm (catalyst weight 10 g) honeycomb type. A deNOx efficiency of the regenerated catalyst showed 100% at $180^{\circ}C$ which is the same level of fresh one.

The material properties study of a construction sludge for recycling (건설오니(建設汚泥) 재활용(再活用)을 위한 재료적(材料的) 특성(特性) 연구(硏究))

  • Soung, Jin-Kyeong;Kim, Soon-Ho;Bae, Won-Tae;Jun, Myung-Hoon
    • Resources Recycling
    • /
    • v.16 no.4
    • /
    • pp.40-46
    • /
    • 2007
  • This research constructed property analysis for an high additional value construction materials. We try to utilize by the addition material of soil stabilizer. It was described to the material properties analysis of a sludge. A sample used 4 kinds of filtration cake which occurs by 4 companies and 3 kinds of sludge before filtration. ph of a sludge, a particle analysis and a scanning electron microscope observation were performed. We analyzed on the chemical ingredient by XRF, the phase by XRD, observed and analyzed the thermo-property of the sludge and the amount of the volatile constituent by TG-DTA.

Characteristics of Leaves, Roots, and Fruit as Influenced by Energized-Functional Water Supply in Fuji Apple Trees (Energized 기능수 처리에 따른 후지사과의 잎, 뿌리 및 과실특성)

  • Kim, Wol Soo;Chung, Soon Ju
    • Horticultural Science & Technology
    • /
    • v.16 no.2
    • /
    • pp.233-235
    • /
    • 1998
  • Energized-functional water (EFW) and powder (EFP) were manufactured by Kyungwon Institute of Life Science, Seoul, through a series of processes; tap water ultra-purification energy imprinting with catalysts in platinum columns mixing energy-imprinted water + activated zeolites + photosynthetic bacteria fermenting at $25^{\circ}C$ filtering EFW and/or EFP. A single application of EFP to soil under tree canopy before bud burst, combined with three EFW applications to soil during growth of 'Fuji' apples (Malus domestica Borkh.) resulted in a higher Ca concentrations in fruit skins and flesh, and lower Ca and N concentrations in leaves and shoot-bark tissues. EFW also stimulated the net photosynthesis of leaves and root activity. Soluble solid concentrations (SSC) and anthocyanin levels of fruits were also significantly increased at harvest, producing greater firmness and less core browning during storage at $0^{\circ}C$. However, there was no significant difference in titratable acidity of fruit juice between the EFW treatment and the controls.

  • PDF

A Review on Lithium Recovery by Membrane Process (멤브레인 공정에 의한 리튬 회수에 대한 총설)

  • Kim, Esther;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.31 no.5
    • /
    • pp.315-326
    • /
    • 2021
  • Lithium ion battery (LIB) demands increase every year globally to reduce the burden on fossil fuels. LIBs are used in electric vehicles, stationary storage systems and various other applications. Lithium is available in seawater, salt lakes, and brines and its extraction using environmentally friendly and inexpensive methods will greatly relieve the pressure in lithium mining. Membrane separation processes, mainly nanofiltration (NF), is an effective way for the separation of lithium metal from solutions. Electrodialysis and electrolysis are other separation processes used for lithium separation. The process of reverse osmosis (RO) is already a well-established method for the desalination of seawater; therefore, modifying RO membranes to target lithium metals is an excellent alternative method in which the only bottleneck is the interfering presence of other metal elements in the solution. Selectively removing lithium by finding or developing suitable NF membranes can be challenging, but it is nonetheless an exciting area of research. This review discusses in detail about lithium recovery via nanofiltration, electrodialysis, electrolysis and other processes.

Alkali Recovery by Electrodialysis Process: A Review (전기투석 공정에 의한 알칼리 회수: 총설)

  • Sarsenbek Assel;Rajkumar Patel
    • Membrane Journal
    • /
    • v.33 no.3
    • /
    • pp.87-93
    • /
    • 2023
  • Electrodialysis (ED) is essential in separating ions through an ion exchange membrane. The disposal of brine generated from seawater desalination is a primary environmental concern, and its recycling through membrane separation technology is highly efficient. Alkali is produced by several chemical industries such as leather, electroplating, dyeing, and smelting, etc. A high concentration of alkali in the waste needs treatment before releasing into the environment as it is highly corrosive and has a chemical oxygen demand (COD) value. The concentration of calcium and magnesium is almost double in brine and is the perfect candidate for carbon dioxide adsorption, a major environmental pollutant. Sodium hydroxide is essential for the metal carbonation process which, is easily produced by the bipolar membrane electrodialysis process. Various strategies are available for its recovery, like reverse osmosis (RO), nanofiltration (NF), ultrafiltration (UF), and ED. This review discusses the ED process by ion exchange membrane for alkali recovery are discussed.

Development of a water treatment efficiency prediction simulator capable of continuous and stable maintenance of water quality (지속적이고 안정적인 수질 유지관리가 가능한 정수처리 효율 예측 시뮬레이터의 개발)

  • Lee, Inhwa;Lee, Taehoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.215-215
    • /
    • 2022
  • 현재 국내 정수시설은 정수공정별 감시제어-데이터수집시스템(SCADA: Supervisory Control And Data Acquisition)에 기반하여 감시제어 및 모니터링 위주로 운영·관리를 실시하고 있다. 또한, 주요 핵심 공정인 응집제 약품투입, 소독 및 여과 설비 공정의 운영방식에 있어서 선험적 운영지식에 의한 방식으로 운영되고 있기 때문에 지속적인 안정적 운영을 위해서는 표준적이고 체계적인 운영관리 수단이 필요하다. 국외에서는 다양한 운영 조건에 기반한 정수처리 효율을 예측할 수 있는 모의(simulation) 도구의 개발을 통해 기존 운영되고 있는 정수장의 효율을 예측하는 데 활용하고 있는 실정이다. 본 논문은 실시간 운영관리가 가능한 기반을 구축하여 정수처리의 효율을 예측할 수 있는 시뮬레이터 개발을 통해 정수처리 공정별 기본 및 조합의 공정 시뮬레이션 모의 모듈 기술을 개발하기 위한 연구를 수행하였다. 또한 개발된 기술의 실증 운영을 통해 검증된 모듈을 반영한 정수장 시뮬레이터 시스템을 개발을 위한 연구를 수행하였다. 정수장 시뮬레이터는 수질정보, 물질수지, 수두손실등의 운영현황 데이터를 수집하는 기능, 착수-혼화-응집-침전-여과-소독 등 개별 공정별 주요 운전변수의 모니터링 및 제어를 통한 운영관리 기능, 원수 수질변화에 신속한 대응을 위한 정수처리 공정제어 의사결정지원 기능, 그리고 온라인 관망해석을 포함한 정수처리 전(단위)공정 시뮬레이터 기능 및 공정별 운영인자 최적화 기능 등으로 구성되어 있다. 현재 운영 중인 정수장의 공정별 운전 상태를 평가·관리하여 정수공정 운영 안정화 체계를 확보하고, 정수장의 유량과 수질의 갑작스런 변화에 따른 모의를 통한 수질예측으로 실시간 정수장 최적운영관리가 가능하다. 또한 원수 성상에 따른 적정 공정운영 자동화로 운영비 절감 및 효율적 인력 활용으로 정수장 운영 효율성을 제고함으로써 지속적이고 안정적인 정수장 운영 체계를 확보할 수 있다.

  • PDF

Open Heart Surgery without Transfusion (수혈 없이 시행한 개심술)

  • Kim, Kun-Il;Lee, Weon-Yong;Kim, Hyoung-Soo;Kim, Shin
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.184-192
    • /
    • 2009
  • Background: Although complications from transfusion are known to happen, transfusion is performed during most open heart surgeries. The aim of this study was to investigate the possibility of performing cardiac surgery without allogenic blood transfusion. Material and Method: Between January to August 2007, 44 consecutive patients who underwent open heart surgery with using various blood conservation methods were retrospectively enrolled. They were divided into group I (the onpump group, n=17) and group II (the offpump group, n=27). The blood conservation methods were intraoperative autologous donation, cell saver, retrograde autologous priming, conventional ultrafiltration and modified ultrafiltration. Antianemic agents were administered to all the patients postoperatively. We analyzed the possibility of bloodless operations, the causes of homologous transfusion, the serial change of the hematocrit and the postoperative chest tube drainage, and we compared the results between the two groups. If comparison between the two groups was not reasonable, then we compared two groups with the individual control groups I and II (49 patients) in 2006. Result: 40 (90.9%) of 44 patients were successfully operated on without transfusion and the success rate was 88.2% (15/17) for group I and 92.6% (25/27) for group II. There was no statistical difference between the two groups (p=NS). The causes of transfusion were 2 cases of postoperative bleedings, 1 case of intraoperative bleeding and 1 mistake of the indication for transfusion. There was no statistical difference of the total chest tube drainage (Group I: $417{\pm}359mL$, Group II: $451{\pm}237mL$) (p=NS), but the total chest tube drainages of the two groups were less than each of the control groups 1 and II (p<0.05). The lowest hematocrit level of Group I was $16.4{\pm}2%$, and this occurred just after infusion of cardioplegics and the hematocrits of both groups were recovered to the preoperative level at 2 months postoperatively. Conclusion: In this study, bloodless open heart surgery could be performed in 90.9% of the patients with intraoperative autologous donation, cell saver, retrograde autologous priming, conventional ultrafiltration and modified ultrafiltration. A combination of various blood conservation methods is the most important and bloodless cardiac surgery could be performed with meticulous bleeding control and strictly following the transfusion indications.

Glomerular Filtration Rate Test Methods and Guidelines (Glomerular Filtration Rate 검사방법 및 가이드라인)

  • Park, Min-Ho;Lee, Ha-Young;Ryu, Hwa-Jin;Yoo, Tae-Min;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.97-100
    • /
    • 2018
  • Purpose The glomerular filtration rate (GFR) test is an important indicator of glomerular filtration and has been used to test renal function and the extent of its function. The GFR test is performed by intravenous injection of radioactive medicines made of $^{51}Cr$-EDTA, and blood concentration is measured by taking blood according to the elapsed time. also, PET-CT, bone scan, transfusion and so on will affect the outcome. Therefore, we will improve the quality of the test by providing guidelines for the GFR test for more accurate testing. Materials and Methods 5 mL of physiological saline solution and 2 mL of $^{51}Cr$-EDTA solution are used to make 5 mL of the radiopharmaceutical solution to be injected into the patient. First, the syringe weight is measured before the injection, and then the radioactive medicine is injected into the patient's vein and the syringe weight is measured after the injection. Blood sampling is performed twice in total. In adults, blood is collected 3 hours / 5 hours after injection and in children 2 hours / 5 hours after injection. The blood sample is centrifuged at 3300 rpm for 5 minutes. Standard solution is prepared by filling diluent water up to the scale indicated in the 200-mL volumetric flask, discarding $500{\mu}L$, injecting $500{\mu}L$ of GFR reagent and mixing well. $500{\mu}L$ each of the standard solution is dispensed into two test tubes, and $500{\mu}L$ of each of the plasma samples collected in time is dispensed into two test tubes and measured with a Cobra Counter. Results At present, the reference range applied in this study is $119.5{\pm}30.3ml/min/1.73m2$ for males and $125.2{\pm}28.2ml/min/1.73m^2$ for females. Conclusion The GFR test is conducted using radioactive medical products. GFR testing is performed as a scheduled test, but PET-CT, dialysis and transfusion, which may affect GFR testing, may be scheduled during GFR testing. Therefore, we could get accurate GFR test results by notifying the ward and department beforehand when booking.

Water Quality Variation and Removal Characteristics of Poliovirus by Biological Activated Carbon (BAC) and Ozone Treatment Process in Nakdong River. (낙동강 원수의 생물활성탄 및 오존처리공정에 따른 수질 변화 및 폴리오바이러스의 제거특성)

  • Jung Eun-Young;Park Hong-Ki;Lee You-Jung;Jung Jong-moon;Jung Mi-Eun;Hong Yong-Ki;Jang Kyoung-Lib
    • Journal of Life Science
    • /
    • v.15 no.5 s.72
    • /
    • pp.696-702
    • /
    • 2005
  • Ozonation is a disinfection technique of harmful mi-crobes commonly used in the treatment of drinking water. And Biological Activated Carbon (BAC) treatment also provides numerous benefits for drinking water utilities, including removal of micro- pollutants, improved treatment processes. The multiful-stage ozonation and BAC play roles as effective methods for removing several materials in raw water. Water quality variation in Nak dong river and the removal efficiency of viruses by ozonation-BAC process were investigated on pilot scale. During the period of survey, most of water quality parameters including $NH_{4}^{+}-N$ were highly improved after passing through the BAC. The removal efficiency of poliovirus type III in water treatment process using pilot-plant,$ 99.6\% $ of viruses were removed by pre-ozonation, sedimentation and sand filteration process, $ 100\% $ were removed after in BAC filteration step. In the removal survey of viruses by ozonation, ap-proximately $ 61.1\% $ or polioviruses were inactivated by ozone of 0.4 mg/l within 5 min. and $ 100\% $ were inactivated by ozone of 0.8 mg/l over 10 min.

Back Flushing Behavior of Microfiltration Membrane Fouled by Alumna Colloidal Suspensions (알루미나 현탁액에 의해 오염된 정밀여과막의 역세척 거동)

  • Nam, Suk-Tae;Han, Myeong-Jin
    • Membrane Journal
    • /
    • v.19 no.1
    • /
    • pp.34-46
    • /
    • 2009
  • Effect of backflushing on the membrane fouling for polyethylene capillary membranes was examined by measuring the flux of $Al_2O_3$ colloidal suspensions through the cross flow microfiltration. In the comparison of with and without the application of backflushing, the hydraulic resistance to permeate flow of the suspension was less with backfluslng, but the Increasing rate in permeate resistance was higher. Regardless of backflushing, the cake filtration was dominant at the initial period of filtration with backflushing, being followed by the pore blocking. And at steady state, the fouling mechanism is almost governed by the cake filtration model. On the contrary, the pore blocking preceded the cake filtration in the initial stage of the original membrane before backflushing. And irrespective of backflushing, the ratio of cake filtration to total fouling increased, compared with that fur before backflushing. For the membrane with $0.24{\mu}m$ pore size, the permeate resistance was higher than that of $0.34{\mu}m$ pore size membrane. but the ratio of cake filtration was smaller than that of large pore membrane. In comparing the ratio of each fouling component to the total fouling for the case with backflushing pore blocking was 7.8% and cake filtration was 92.2%. for the case without backflushing, total fouling was composed of 9.6% pore blocking and 90.4% cake filtration.