• Title/Summary/Keyword: 전압 변압기

Search Result 600, Processing Time 0.031 seconds

A Design of PFM/PWM Dual Mode Feedback Based LLC Resonant Converter Controller IC for LED BLU (PFM/PWM 듀얼 모드 피드백 기반 LED BLU 구동용 LLC 공진 변환 제어 IC 설계)

  • Yoo, Chang-Jae;Kim, Hong-Jin;Park, Young-Jun;Lee, Kang-Yoon
    • Journal of IKEEE
    • /
    • v.17 no.3
    • /
    • pp.267-274
    • /
    • 2013
  • This paper presents a design of LLC resonant converter IC for LED backlight unit based on PFM/PWM dual-mode feedback. Dual output LLC resonant architecture with a single inductor is proposed, where the master output is controlled by the PFM and slave output is controlled by the PWM. To regulate the master output PFM is used as feedback to control the frequency of the power switch. On the other hand, PWM feedback is used to control the pulse width of the power switch and to regulate the slave output. This chip is fabricated in 0.35um 2P3M BC(Bipolar-CMOS-DMOS) Process and the die area is $2.3mm{\times}2.2mm$. Current consumptions is 26mA from 5V supply.

Development of DC-DC Converter for Arc Welding Machines using A Novel Half Bridge Soft Switching PWM Inverter (새로운 하프 브리지 소프트 스위칭 PWM 인버터를 이용한 용접기용 DC-DC 컨버터의 개발)

  • Kwon, Soon-Kurl;Mun, Sang-Pil
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.4
    • /
    • pp.60-67
    • /
    • 2008
  • This paper presents a new full-bridge soft switching PWM DC-DC converter circuit topology that adding two switcher, two lossless snubber quasi-resonance capacity, two diode to power source for general welding machine. This half bridge soft switching Is low voltage hight current output that first coil current is smaller than second coil current in high frequency transformer can be obtained with decreasing path loss in conventional DC bus line switcher. As it operate ZCS/ZVS in full range, high frequency, high efficiency and high output are implemented at low voltage and high DC current switching power supplies. All of this items are got from simulation and the result of experiment. If make up for the weak points of this proposed circuit, it will be used more easily for next generation TIG, MIG and MAG type of arc-welding machine.

Frequency control method of ozonator power supply (오존발생기 구동장치의 주파수제어에 관한 연구)

  • 최규남
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.4
    • /
    • pp.887-893
    • /
    • 1999
  • The characteristics of ozone generator targeted for air or water sterilizing in the vessel utilizing the surface corona discharge between the electrodes on the ceramic substrate was investigated by using the frequency control method. The frequency control was achieved by controlling the degree of resonance between the secondary winding inductance of transformer and the electrode capacitance of ceramic discharge plate, and the range of control was found to be 5 times of discharge current. This frequency control method showed the efficiency of 28 mP ozone generation and the stability within 3.4 % when the input voltage was varied within 40% range. The frequency control method is regarded to be more efficient way of corona discharge control compared to the conventional on/off control or voltage control methods.

  • PDF

A Compensation Method considering Unbalance of Reactor at Source Side in Driving 3 Phase Voltage type PWM Converter (3상 전압형 PWM 컨버터 운전시 전원측 리액터의 불평형을 고려한 보상법)

  • Chun, Ji-Yong;Lee Sa-Young;Cho Yu-Hwan;Lee Geun-Hong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.373-379
    • /
    • 2005
  • In this paper, the control algorithm of DC source device for inverter starting is proposed and the control method for compensating unbalance system source on operating time in the voltage type PWM converter with driving and regenerative faculty is suggested. The maintaining way of balancing condition for converter of AC source is used the compensating unbalanced status by current control loop. Because it is possible that the unbalanced System control is used to leakage transformer not equaled reactance by each phase in rectifier system, the proposed H/W and control algorithm of rectifier system is contributed to minimize of device and rising efficiency.

Development of 8kW/L, 700kHz GaN based Auxiliary Power Module using planar matrix transformer for xEV (8kW/L, 700kHz 평면변압기를 이용한 GaN 소자 기반 친환경자동차용 LDC 개발 및 손실 분석을 통한 구조 설계)

  • Kim, Kyu-young;Kim, Sang-jin;Adhistira, Adhistira;Choi, Se-wan;Yang, Dae-ki;Hong, Seok-yong;Lee, Youn-sik;Yeo, In-yong
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.168-169
    • /
    • 2019
  • 본 논문은 친환경자동차용 저전압 DC-DC 컨버터(Low-voltage DC-DC converter, LDC)의 고전력밀도 달성을 위한 스위칭 주파수 선정 및 구조 설계 방법을 소개한다. 위상천이 풀-브릿지(Phase-Shift Full-Bridge, PSFB) 컨버터의 손실 분석을 통해 스위칭 주파수 700kHz 선정하였으며, 냉각수 온도 65℃, 분당 8리터의 유량 기준으로 소자 온도가 110℃ 이내로 관리 되도록 고려하여 구조 설계를 수행했다. 온도 조건을 만족하면서 8kW/L의 높은 전력밀도를 달성하였으며 입력전압 200V-310V, 출력전압 12.8V-15.1V의 전압 범위를 만족하는 1.8kW 최종 시작품을 제작하여 실험으로 검증하였다.

  • PDF

A Study on the Ground Fault Protection Relay's malfunction or non-tripping in 6600V Non-grounding High Voltage Power System (6600V 비접지 전력계통 지락보호계전기의 오.부동작에 관한 연구)

  • Kim, Byung-Tae;Jeon, Myung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2013-2014
    • /
    • 2008
  • 6.6KV 고전압 위험으로 접지계기용변압기(GPT)와 영상변류기(ZCT)의 2차측에 전압 전류 시험 유입방식으로는 해당 지락보호계전기의 정.부동작이 정확한지 검증이 되지 않아 안전사고 발생의 우려성이 존재하고 있었으며, 이의 해결을 위하여 6.6KV 고압측에 인공지락시험을 통하여 국내외 일부 계전기의 동작 전압 전류 극성이 사양과 상이한 것을 발견하여 실계통에 합당하도록 시정함과 동시에 감전시 인체 저항을 감안한 지락보호계전기(OVGR, SGR) 정정값을 도출하여 인명을 보호하게 하기 위한 지락보호계전 시스템에 대한 연구이다.

  • PDF

A Study on the Application of SVR at the Distribution Line Interconnected with Wind Turbine (풍력발전이 연계된 배전선로의 SVR 적용연구)

  • Chae, Woo-Kyu;Lee, Hak-Ju;Jung, Won-Wook;Kim, Ju-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.109-118
    • /
    • 2010
  • It is expected that distribution system, interconnected with wind turbines, would experience the voltage problem due to WT's output. But most papers just consider this problem using the simulation or the theory only. In this paper, we verify this problem through the measurement at the distribution system and wind turbine. We explain the method for voltage management at distribution system. And we verify that the voltage of D/L interconnected with WTs could not be maintained properly using pole transformer's tap only. We consider some method to solve this problem and we propose the installation of SVR(step voltage regulator). Finally we show this method's validity through the simulation.

A Study on the Design Parameters of the Static Ring in the Ultra-high Voltage Non-uniform Electric Field (초고압 불평등 전계에서 정전링 설계변수에 대한 연구)

  • Kim, Jin-Sung;Seo, Min-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.577-582
    • /
    • 2020
  • Electricity produced at power plants is distributed to consumers through several stages of substations. At this time, an ultra-high voltage transformer is needed in the initial transmission stage to transmit a voltage suitable for each consumer. A high voltage, non-uniform electric field is formed at the end of the winding of the ultra-high voltage transformer, which carries a risk of dielectric breakdown. The winding of the ultra-high voltage transformer is an electrode, which is the key to converting the magnitude of the voltage. A non-uniform electric field is formed along the shape of the winding end, resulting in high electrical stress. The static ring installed at the upper and lower ends of the winding is used to disperse the stress at the winding end. Several variables should be considered when designing a static ring. Among them, this study examined how the curvature of the static ring, the thickness of the insulating paper, the number of barriers, and barrier thickness affect the electrical stress of the static ring using the Finite Element Method. Suggestions to be considered when designing the static ring are proposed through the FEM results.

The Characteristics Analysis and Design of High-Frequency Isolated Type ZVZCS PS-PWM DC-DC Converter with Fuel Cell Generation System (연료전지 발전시스템에 적용된 고주파 절연형 ZVZCS PS-PWM DC-DC 컨버터의 설계 및 특성 해석)

  • Suh, Ki-Young;Mun, Sang-Pil;Kim, Dong-Hun;Lee, Hyun-Woo;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.21-28
    • /
    • 2006
  • In this paper, the proposed full-bridge high frequency isolated zoo voltage and zero current switching phase shifted pulse width modulation(ZVZCS PS-PWM)DC-DC converter among fuel cell generation system consist of 1.2[kW] fuel cell of Nexa Power Module, full-bridge DC-DC converter to boost the fuel cell low voltage($28{\sim}43[%]$) to 380[VDC] and a single phase full-bridge inverter is implemented to produce AC output(220[VAC], 60[Hz]). A tapped inductor filter with freewheeling diode is newly implemented in the output filter of the proposed full-bridge high frequency isolated ZVZCS PS-PWM DC-DC converter to suppress circulating current under the wide output voltage regulation range, thus to eliminate the switching and transformer turn-on/off over-short voltage or transient phenomena. Besides the efficiency of $93{\sim}97[%]$ is obtained over the wide output voltage regulation ranges and load variations.

Circuit DQ Modeling and Analysis of Operating Characteristics for Hybrid Cascade Five-level PWM Rectifier (하이브리드 Cascade 5-레벨 PWM 정류기의 회로 DQ모델링 및 동작특성 해석)

  • 최남섭
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.4
    • /
    • pp.817-824
    • /
    • 2000
  • This paper presents circuit DQ modeling and analysis of operating characteristics of hybrid cascade multilevel PWM rectifier, especially five-level, without isolation transformers. The circuit DQ transformation changes the original three-phase time varying circuit to stationary equivalent one by employing the synchronously rotating transformation matrix. As a result of circuit DQ modeling, the operating characteristics and some useful design relationships for the system are obtained with ease. That is, the analytic equations for DC voltages and active/reactive power supplied by source with respect to control variables are Presented. Moreover, the DC voltages for the multilevel output generation may be directly built up from AC utility source and the important control equation ensuring 5-level output voltage is obtained. Finally, to confirm the validity of the analysis, MATLAB simulations are carried out and the simulation results show good agreements between analytic predictions and the simulated waveforms.

  • PDF