• Title/Summary/Keyword: 전압 변압기

Search Result 600, Processing Time 0.021 seconds

A New Asymmetrical PWM Bidirectional Half Bridge Converter for Wide Input Voltage Range Applications (넓은 입력 전압 범위를 갖는 새로운 비대칭 PWM 방식의 양방향 하프브리지 컨버터)

  • Kim, Jeong-Geun;Choi, Se-Wan;Park, Rae-Kwan;Chang, Seo-Geon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.235-242
    • /
    • 2009
  • In this paper a new asymmetrical PWM bidirectional half bridge converter is proposed. The proposed converter has simple structure and wide duty cycle range, and therefore is suitable for applications such as fuel cells which have wide voltage variation. With the proposed asymmetrical PWM method the current rating of switch and transformer is significantly reduced compared to the conventional phase angle control method, and ZVZCS and synchronous rectification can also be achieved. This could result in high efficiency and high power density. The proposed converter is analytically compared to the conventional converter, and the proposed method was validated through the experiment.

Contactless Power Transfer System using Voltage Phase (전압위상을 이용한 무접점 전원공급 시스템에 관한 연구)

  • Yu, Joo-Hee;Kim, Choon-Sam
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.219-226
    • /
    • 2011
  • As the existing contactless power transfer system(CPTS) is adopting the principle of contactless transformer enables to supply power in contactless way using RFID(radio frequency identification)/ID communication method between primary and secondary sides of contactless transformer and detect the alien load. Such CPTS requires the circuit that generates ID in addition, and the ID identification and control generated from the secondary side is performed at the primary side, which cuases complexity of the circuit. Therefore, this study suggested the CPTS using voltage phase, and In order to verify the validity of this study, 3[W] class CPTS shall be designed, and the simulation and test of CPTS using current and voltage phases shall be carried out.

Commissioning Test of the MMC(Modular Multi-level Converter) type 25MVA HVDC Pilot Project (MMC(Modular Multi-level Converter) type 25MVA HVDC 실증단지 Commissioning Test)

  • Jeong, Jong-kyou;Jung, Hong-ju;Yoo, Hyun-ho;Park, Yong-hee;Lee, Doo-young
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.282-283
    • /
    • 2017
  • 본 논문은 (주)효성 중공업연구소에서 국책과제를 통해 자체 개발한 MMC(Modular Multi-level Converter) type ${\pm}12kV$ 25MVA HVDC 시스템에 대하여 실증단지 구축 및 commissioning test에 대한 소개를 한다. 제주에 구축된 HVDC 실증단지는 국내 유일의 MMC type 전압형 HVDC 시스템이며 11-레벨의 AC 출력 전압을 형성하는 2개의 컨버터가 Back-to-Back 형태로 구성되어 있다. 각 컨버터의 AC 출력단은 각각 계통과 풍력발전단지에 연계되어 풍력발전단지에서 생산된 전력을 계통으로 전송하는 역할을 한다. 주요 AC/DC Yard 기기들로는 AC 고조파 필터, 밸브리액터, DC 리액터, 변압기, CGIS등이 있다. HVDC 의 commissioning test를 위해 IEEE, IEC, Cigre TB 등의 문서들을 종합 분석하여 당사의 시스템에 알맞은 시험절차서와 검증항목을 준비하였다. 본 논문에서는 당사에서 준비한 시험절차서 및 검증항목에 대하여 소개하고자 한다.

  • PDF

A Novel SLLC Series Resonant Converter for The Boost DC/DC Converter (SLLC 직렬공진컨버터 적용 승압형 DC/DC 컨버터)

  • Kim, Eun-Soo;Kang, Sung-In;Chung, Bong-Geun;Cha, In-Su;Yoon, Jeong-Phil
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.56-64
    • /
    • 2007
  • Recently, the high frequency link boost DC/DC converter has been used widely for PCS (Power Conditioning System) because of the requirements of small size and low cost. However, the high frequency link boost DC/DC converters applied the conventional voltage-fed converter and current-fed converter have some problems like high conduction losses and high surge voltage due to high circulating current and leakage inductance, respectively. To improve these problems, a novel secondary LLC (called SLLC) series resonant converter is proposed in this paper and its theoretical analysis, its operating waveforms, simulation and experimental results for a boost DC/DC converter using SLLC series resonant topology verifies the proposed topology. 800W experimental prototype is tested.

초소형 Travel Adapter 전력변환 기술 동향

  • Ji, Sang-Geun;Kim, Min-Ji
    • KIPE Magazine
    • /
    • v.27 no.3
    • /
    • pp.26-30
    • /
    • 2022
  • 핸드폰, 노트북 빛 태블릿 PC와 같이 휴대할 수 있는 전자기기의 사용량이 높아질수록 대용량의 배터리를 필요로 하게 된다. 배터리 사양이 높아질수록 대용량의 배터리를 빠르게 충전시키는 어댑터 (Adapter)는 필수 요구 사항이 되었다. 고속 충전을 하기 위해선 높은 전류 공급 능력이 필요하며, 휴대성을 높이기 위해서 사이즈를 최소화하여 설계되어야 한다. 고효율 및 고밀도를 요구하는 시장에 걸맞게, 어댑터 시장 역시 Topology부터 사용 소자까지 많은 발전 중에 있다. 어댑터에 사용되는 대표적인 Topology는 절연에 용이하며 회로구조가 간단한 저비용, 고효율 Flyback Converter 회로가 기본적으로 사용된다. 하지만, 이 구조는 스위칭 주기마다 스위치 양단 전압 및 전류의 중첩에 의한 스위칭 손실이 불가피 하다는 단점이 존재한다. 그 단점을 보완하기 위해 RCD 스너버로 클램핑을 시켜줌과 동시에 변압기의 자화 인덕턴스와 스위치의 기생 커패시터의 공진 현상을 이용하여 스위치 양단 전압 VDS가 최소화되는 지점에서 다음 스위칭 동작을 수행하는 QR(Quasi-Resonant) Flyback Converter를 사용한 어댑터가 시장에서 주로 보였다. 하지만 QR Flyback Converter 역시 기존 방식보다 유리하지만 이 또한 스위칭 주파수 증가에 따른 한계가 존재한다. 따라서 현재는 영전압 스위칭 (Zero Voltage Switching, ZVS)이 가능한 ACF(Active Clamp Flyback) Converter 회로의 연구 개발이 활발히 진행되고 있다. 이때 스위칭 특성이 우수한 GaN-FET를 적용한 어댑터가 시장에 출시되고 있다. 특히, 이 시장에서는 GaN 소자를 적용한 어댑터를 차세대 전력 반도체 적용이라는 마케팅에도 이용되는 것을 확인할 수 있다.

A study on the voltage rise of the inverter output terminal according to the low voltage Grid connection of solar power generation (태양광발전 저압연계시 인버터 출력단 전압상승에 대한 연구)

  • Cho, Kang-yeon;Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.746-752
    • /
    • 2020
  • As environmental issues have been taken seriously, the number of solar power generation facilities has rapidly increased in Korea. The voltage at the output stage of an inverter increases in a system that connects a small-capacity photovoltaic power generation to low-voltage power distribution. This degrades the quality of the low-voltage distribution system and adversely affects the load facility. In this study, a solution was obtained to increase the voltage at the output stage of the solar inverter according to the connection of the low-voltage distribution system. The voltage can be controlled by using reactive power factor control inverters. If the secondary tap is adjusted, the voltage can be adjusted to about 15 V, but there is a problem in that the tap is not adjusted unless the KEPCO distribution regulation voltage is out of the range of 220±13V. If the number of inverters is limited, the inverter can be started within the inverter overvoltage range. If it is connected to three phases, the voltage is distributed. The results indicated that power factor control and active voltage control inverters were easy to apply in the field.

Partial discharge properties of insulating materials for UPS (UPS용 절연재료의 부분방전 특성)

  • 이덕진
    • Journal of the Korea Computer Industry Society
    • /
    • v.4 no.12
    • /
    • pp.1013-1020
    • /
    • 2003
  • In this paper, the discharge properties due to time variation were investigated in order to estimate a electrical performance of the insulator for small transformer. AC 10[kVl applied to specimen was converted to $\pm$5[V] and stored to personal computer through A/D converter. A period of applied wave form and discharge values were divided into 64 parts and discharge values generated during 10 seconds were accumulated by phases. As a result, it was confirmed that count of discharge, total discharge and the variation degree of average discharge were decreased as time elapsed.

  • PDF

Failure Cause Analysis for Loss of Off-site Power Test during Normal Full Power Operation On Wolsong-4 NPP (월성원전 4호기 전 출력 운전시 소외전원상실시험 실패 원인분석)

  • Chang, Tae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.175-181
    • /
    • 2000
  • 월성원자력4호기가 '99.06.09일 11:53분 경 전출력 소외전원상실시험시 주발전기 병입차단기 및 기동용변압기 차단기의 트립과 동시에 예상 밖의 13.8Kv 원자로 냉각재펌프모터#3(9.000HP)이 순시과전류 보호계전기(50Y) 동작으로 트립되어 이로 인한 냉각재 저유량으로 원자로 제1정지계통이 동작되고 원자로가 비상정지 되어 동 시험이 실패되었음. 이 비정상적인 고장은 예비디젤발전기의 수동 기동 병입과 터빈 수동 정지 및 주발전기 트립후 적절한 조치로 소내전원은 정상적으로 복구되었음. 이에 대해 냉각재펌프모터#3의 순시과전류 동작 원인을 유도전동기의 전원상실 후 발생되는 잔류전압(Residual Voltage)과 공급 모선전압(Bus Voltage) 측면에서 분석하며, 모터의 회전속도, 위상각, 잔류전압크기 변화 및 신속개방 절체시 냉각재펌프모터의 돌입 기동전류를 계산하고, PSS/E 프로그램을 사용한 간략한 모의 사례로 검증하였으며 이에 대한 재발방지를 위한 대책을 제시함.

  • PDF

A Study on the Inverter Arc Welder with High Power Factor Using Single-Chip Microprocessor (싱글칩 마이크로프로세서를 이용한 고역율 인버터 아크 용접기에 관한 연구)

  • 채영민;이승요;신우석;목형수;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.4
    • /
    • pp.56-64
    • /
    • 1997
  • 최근 용접분야에서는 용접성능을 향상시키기 위하여 인버터회로를 용접기에 적용한 인버터 용접기에 관한 연구가 활발히 진행되고 있다,. 그러나 범용의 인버터 용접기의 경우 다이오드 정류기를 사용함에 저차의 전류고조파가 발생하고 시스템 역율을 저하시킨다. 따라서 본 논문에서는 인버터 아크 용접기의 역율개선을 위한 PWM 컨버터에 관하여 연구하여 입력전류의 저차 고조파를 저감하였고 전원전압과 동상으로 전원전류를 제어함에 의한 단위 역율형 인버터 용접기의 특성을 해석하였다. 또한 본 논문에서는 에너지 절약, 용접 특성, 역율, 사용율, 크기 및 부피 등의 관점에서 인버터 아크용접기의 응용연구 및 실험적 분석을 수행하였고 용접기 시스템에서 발생하는 전기적 노이즈를 억제하고 전력용 반도체 소자를 보호할 목적으로 새로운 노이즈 차폐변압기를 채택하였다. 이상의 전체시스템은 싱글칩 마이크로 프로세서를 이용한 디지털 제어기로 구현함으로서 제어기의 유연성과 기능의 다양화를 추구하였다.

  • PDF

The Implementation of Current Compensation Controller in Driving Voltage type Converter considering the Unbalance of Reactor at the Source Side (전원측 리액터 불평형을 고려한 전압형 컨버터의 전류 보상 제어기 구현)

  • Chun Ji-Yong;Cho Yu-Hwan;Lee Geun-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.5
    • /
    • pp.413-420
    • /
    • 2004
  • In this paper, the control algorithm of DC source device for inverter starting is proposed and the control method for compensating unbalance system source on operating time in the voltage type PWM converter with driving and regenerative faculty is suggested. The maintaining method of balancing condition for converter of AC source is used the compensating unbalanced status by current control loop. In order to solve the problem which the unbalanced system control is used to leakage transformer not equaled reactance by each phase in rectifier system. The proposed H/W and control algorithm of rectifier system is contributed to minimize of device and rising efficiency.

  • PDF