• Title/Summary/Keyword: 전압 강하

Search Result 480, Processing Time 0.028 seconds

Study on improvement of on-state voltage drop characteristics According to Variation of JFET region of IGBT structure (IGBT 구조의 JFET영역 변화에 따른 온-상태 전압강하 특성 향상을 위한 연구)

  • Ahn, Byoung-Sup;Kang, Ey-Goo
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.339-343
    • /
    • 2018
  • Power semiconductors are semiconductors capable of controlling power over 1W and are mainly used as switches. This power semiconductor device has been developed with the goal of reducing power consumption and high breakdown voltage. This research was analyzed electrical characteristics of IGBT(Insulated Gate Biopolar Transistor) according to diffusion length of JFET region. The Diffusion length of JFET region was controlled by temperature and time using T-CAD simulator. As a result of experiments, we could obtain 1.14V low on state voltage drop by fixing 1440V breakdown voltage.

A Study On the Steady-state Voltage Profile Analysis for Distribution Feeders with Distributed Generations (정상상태에서 분산전원 대응형 전압강하 해석에 관한 연구)

  • Son, Joon-Ho;Ji, Seong-Ho;Park, Hyen-Seok;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05a
    • /
    • pp.60-62
    • /
    • 2010
  • 최근 태양광, 풍력 등의 분산전원이 배전계통에 도입되어 운영되고 있다. 현재의 배전계통에 스마트 그리드 연계 시 전력 공급의 신뢰성 및 안정성, 전력 품질의 확보를 위한 계통 계획이나 해석을 위해 가장기본적으로 역 조류를 고려한 전압강하 계산이 필요하다. 본 논문에서는 기존의 역 조류 전압강하 계산방법을 개선하여, 분산전원의 출력변동(역 조류)을 고려하여, 간편하게 전압강하를 계산할 수 있는 분산전원 대응형 전압강하 해석법을 제안하고자 한다.

  • PDF

Three-Phase Quasi Z-Source DVR System using PSIM (PSIM을 이용한 3상 Quasi Z-소스 DVR 시스템)

  • Oh, Seung-Yeol;Jung, Young-Gook;Lim, Young-Choel;Kim, Kwang-Heon
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.458-459
    • /
    • 2010
  • 일반적으로 전력 품질을 저하시키는 여러 문제들 중에서 가장 빈도가 높고 민감한 부하를 가지고 있는 수용가에 많은 영향을 주고 있는 것이 순간적인 전압상승(voltage swell)과 전압 강하(voltage sag)인데, 순간 전압 강하는 짧은 시간 동안 공급 전압의 크기가 줄어드는 것으로 대부분 인접한 배전 선로에서의 사고가 그 원인으로 작용한다. 이러한 순간 전압 강하는 제조공정의 제어를 위한 자동화 기기 등의 오동작이나 작업정지 등의 문제를 유발하여 경제적으로 큰 손실을 일으키게 되는데 이러한 순간 전압 강하의 문제를 해결하기 위한 대표적인 전력 전자 기기로는 일반적으로 동적 전압 보상기(Dynamic Voltage Restore: DVR)가 있다. 본 논문에서는 새로운 3상 Quasi Z-소스 DVR을 제안하였다.

  • PDF

Virtual impedance based droop method for high-capacity parallel inverters under unbalanced line impedances (불평형 라인 임피던스를 가진 고용량 병렬형 인버터 구동을 위한 가상임피던스 기반의 드룹제어)

  • Lim, Kyungbae;Ko, Seungwoo;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.83-84
    • /
    • 2015
  • 본 논문에서는 무효전력 오차를 야기하는 유도성-저항성 복합성의 불평형 임피던스 선로 하에서 가상 인덕터와 가상 저항을 사용한 드룹 제어 기반의 병렬형 인버터 시스템에 관해 다루고 있다. 여기서 무효 전력 분담 에러는 각 선로 임피던스의 전압 강하를 고려함에 따라 개선 가능하다. 그러나 병렬형 인버터 시스템이 고전류, 고용량일 경우 지령 출력 전압 크기는 정격 전압 크기에 미치지 못하게 되며 이는 가상 인덕터 및 저항값과 출력 전류의 곱을 통한 가상 임피던스의 전압강하 산출법에 기인한다. 이러한 이유로 본 논문에서는 기존의 드룹 방식에 선로 임피던스 전압 강하 뿐만 아니라 가상 임피던스의 전압 강하도 추가되었고 이를 통해 병렬형 인버터의 전압 출력이 정격 출력값의 범위 안에서 구동하도록 하였다. 가상 인덕터와 가상 저항의 적용법에 대한 비교에 기반을 둔 제안된 드룹 방식은 PSIM 시뮬레이션을 통해 검증되었다.

  • PDF

Bus Voltage Drop Analysis Caused by Payload Operation of LEO Satellite (저궤도 인공위성 탑재체 구동에 따른 버스 전압 강하 해석)

  • Park, Hee-Sung;Jang, Jin-Baek;Park, Sung-Woo;Lee, Sang-Kon
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.57-62
    • /
    • 2010
  • SAR payload of LEO satellite will consume about 150A current. This high current makes the voltage drop between battery, satellite main bus and payload interface, which cannot guarantee the input voltage level of the satellite electrical unit and payload. So, it is necessary to predict the main bus and payload input voltage level when the payload works. In this paper, the worst case analysis of the harness and contact resistance was executed and predicted the voltage drop when the payload works.

A Study on the Instantaneous Voltage Drop Compensator through the Series Voltage Injection (직렬 전압주입에 의한 순간전압강하 보상기기에 관한 연구)

  • 전영환;김지원;전진홍
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.310-317
    • /
    • 2001
  • The instantaneous voltage drop is occurred when the fault is happened on the nearby feeders. The instantaneous voltage drop is continued during relatively short period. But, the effect of it can be very severe to some sensitive devices. That is, it can be the reason of restart or malfunction of some devices. And these phenomenons can cause the enormous economical damage and shorten the lifetime of the devices. In this paper the device which can compensate the instantaneous voltage drop, is studied. The device injects the voltage to the power system through the series transformer. The validity of the proposed algorithm using peak detection method is verified through the computer simulation and experiments.

  • PDF

Dynamic Voltage Restorer Applied to Real Power System using Voltage Sag Detection (전압강하 검출을 이용한 동적전압보상기의 실계통 적용)

  • Lee, Hyun-Woo;Park, Jung-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.203-204
    • /
    • 2015
  • 본 논문은 실제 전력계통을 모의한 A계통에서 3상 지락 사고가 발생하였을 때, 순시 전압강하를 보상하기 위한 동적전압보상기(Dynamic Voltage Restorer)의 동작에 따른 해당 부하의 영향성을 연구하였다. 동적전압보상기의 동작을 위한 전압강하 검출은 RMS Detection 기법을 통해 구현하였으며, IEEE Standard 1159-1995의 기술된 Voltage Sag의 정의에 따라 동적전압보상기의 on/off 제어를 수행하였다. A계통 모델링을 포함한 모든 시뮬레이션은 PSCAD/EMTDC 상에서 구현하였으며, RMS 전압 측정 및 Voltage Sag 검출 신호, 그리고 동적전압보상기의 동작 전 후에 따른 순시 부하전압 파형을 결과로 다룰 것이다.

  • PDF

Voltage Compensation Method of Industrial Inverter for Motor Control (산업용 인버터의 출력전압 보상방법)

  • Jeong, Se-Jong;Kim, Seung-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.39-40
    • /
    • 2015
  • 산업용 인버터에서 출력전압은 소자의 전압강하와 데드타임에 의해 왜곡이 발생되며, 이로 인해 출력 전류의 품질을 저하시키고 전동기 축 토크의 진동을 유발한다. 이러한 현상을 방지하기 위해서는 출력전류에 따라 출력전압을 보상하여야 한다. 하지만 임의의 스위칭 주파수에서 측정된 전압왜곡량으로 보상량을 결정할 경우, 스위칭 주파수가 변경되면 전압 왜곡이 커지게 된다. 따라서, 소자의 전압강하와 데드타임에 의한 전압 왜곡은 스위칭 주파수에 따라 적절히 변경되어야 한다. 본 연구에서는 인버터 전력소자의 전압강하량과 데드타임량을 개별 측정하여 보상하는 방법을 제시하였고, 그 유효성을 실험을 통해 검증하였다.

  • PDF

A Study on the dynamic voltage restorer using hybrid capacitor (하이브리드 커패시터를 적용한 순간전압강하 보상장치에 관한 연구)

  • Seo, Ansik;Maeng, Jucheol;Yoon, Jungrag
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.75-76
    • /
    • 2013
  • 최근 산업 및 경제의 급속한 발전으로 컴퓨터를 비롯한 전기 및 전자 장비, 통신기기, 반도체 장비 등 전기적 외란에 민감한 부하 설비의 사용이 급증하면서 전력 품질에 대한 관심이 고조되고 있다. 그 이유는 정밀 부하 장비들이 전압의 순간적 변동에 대하여 민감하여 이 문제로 인하여 파생되는 경제적 피해가 매우 크기 때문에 지속적인 관리가 필요하다. 이러한 문제 중에서 가장 빈번하게 발생하는 순간 전압 강하를 보상하기 위한 장치로 전기 이중 층 커패시터 (EDLC: Electric Double Layer Capacitor)를 에너지 저장장치로 사용한 순간전압강하 보상장치 (DVR: Dynamic Voltage Restorer) 시스템이 개발 되어 적용되고 있다. 본 논문에서는 현재 순간전압강하 보상장치에 사용되는 DVR 시스템에서 주로 사용되는 에너지 저장장치인 EDLC 보다 동일 사이즈 대비 에너지 밀도가 높은 하이브리드 커패시터를 적용하는 연구를 하고자 한다.

  • PDF

A Study on Development of Test Equipment for Voltage Variable (전압가변 시험장치의 개발에 관한 연구)

  • 김응상
    • Journal of Energy Engineering
    • /
    • v.9 no.2
    • /
    • pp.130-137
    • /
    • 2000
  • 신에너지 전원의 배전 계통과의 실제 연계 운전상에서 순간정전, 순간전압상승, 및 강하등의 전압가변 현상이 자주 발생하게 된다. 본 논문에서는 이러한 영향에 따른 문제점을 검증하여 사전에 대처할 수 있는 방안을 모색하고자 전력품질의 변화를 임의로 발생시키고 특정시간후에 다시 원상으로 회복시키는 전원의 전압가변 시험장치를 개발하였다. 개발한 시험장치는 개폐스위치, 바이패스 스위치, 가변 변압부, 전압·전류 검출부 직류전원공급기, 제어·구동부 , 표시·조작부 등의 구성을 가지고 있다. 개발한 시험장치의 정상적인 동작에 의한 기능을 확인하기 위하여 실제 배전 계통에 적용하여 순간정전, 순간전압상승 및 강하시험을 실시하며 전압·전류 파형을 측정·분석하여 시험장치의 신뢰성과 , 효용성을 검증하였다.

  • PDF