• Title/Summary/Keyword: 전압변화 보상

Search Result 134, Processing Time 0.029 seconds

Low-Power CMOS On-Chip Voltage Reference Circuits (저전력 CMOS On-Chip 기준전압 발생회로)

  • Kwon, Duck-Ki;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.4 no.2 s.7
    • /
    • pp.181-191
    • /
    • 2000
  • In this paper, two schemes of generating reference voltages using enhancement-mode MOS transistors and resistors are proposed. The first one is a voltage-mode scheme where the temperature compensation is made by summing a voltage component proportional to a threshold voltage and a voltage component proportional to a thermal voltage. In the second one, that is a current-mode scheme, the temperature compensation is made by summing a current component proportional to a threshold voltage and a current component proportional to a thermal voltage. The designed circuits have been simulated using a $0.65{\mu}m$ n-well CMOS process parameters. The voltage-mode circuit has a temperature coefficient less than $48.0ppm/^{\circ}C$ and a power-supply(VDD) coefficient less than 0.21%/V for a temperature range of $-30^{\circ}C{\sim}130^{\circ}C$ and a VDD range of $3V{\sim}12V$. The current-mode circuit has a temperature coefficient less than $38.2ppm/^{\circ}C$ and a VDD coefficient less than 0.8%/V for $-30^{\circ}C{\sim}130^{\circ}C\;and\; 4V{\sim}12V$. The power consumption of the voltage-mode and current-mode circuits are $27{\mu}W\;and\;65{\mu}W$ respectively for 5V and $30^{\circ}C$. Measurement results show that the voltage-mode reference circuit has a VDD coefficient less than 0.63%/V for $30^{\circ}C{\sim}100^{\circ}C$ and has a temperature coefficient less than $490ppm/^{\circ}C\;for\;3V{\sim}6V$. The proposed reference circuits are simple and thus easy to design. The proposed current-mode reference circuit can be designed to generate a wide range of reference voltages.

  • PDF

Analysis of Condenser Thermal Distribution by the Variance of Voltage & Frequency (전압 및 주파수 변동에 따른 콘덴서 열 분포 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.33-36
    • /
    • 2009
  • 콘덴서는 유도성 부하의 늦은 역률 보상으로도 사용되며, 비선형 부하에서 발생하는 고조파를 저감하기 위해 리액터에 직렬로 연결하여 사용되기도 한다. 콘덴서는 전압이 증가할 경우 전류도 함께 증가하고, 주파수가 증가할 경우 콘덴서에 흐르는 전류가 증가하기 때문에 전류의 증가는 바로 열의 증가로 콘덴서 절연에 스트레스로 작용하여 고장의 원인을 제공할 수 있다. 본 연구에서는 콘덴서에 인가되는 전압의 크기와 주파수를 변화시킬 경우 콘덴서에서 발생하는 열을 열화상 카메라로 측정하여 외부 및 내부에서의 온도분포를 분석하였다. 측정결과 전압과 주파수가 증가할 경우 콘덴서에서 열이 매우 높게 분포함을 확인할 수 있었다.

  • PDF

Compensation of Resistance Variation due to Temperature in Voltage Measurement System (온도에 따른 저항 변화를 보상한 전압 측정 방법)

  • Min, Sang-Jun;Kim, Jin-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.11
    • /
    • pp.1174-1177
    • /
    • 2012
  • In voltage measurement by using voltage divider with series resistors, error is generated caused by the variation of resistance. In order to reduce these errors, the hardware cost tends to increase in the previous works. In the proposed method, three resistors are used for the voltage divider of which the organization is adjusted by using switches. Three voltages are measured and the ratio of resistance is calculated based on the measured voltages. Since the resistance ratio is calculated by measuring voltages and additional hardware cost is minimal, the voltage can be measured with high accuracy and low cost. Experimental results show that the mean absolute error is 12.1 mV when the input voltage ranges from 5 V to 50 V.

Development of Temperature Compensated Micro Cone by using Fiber Optic Sensor (광섬유를 이용한 온도 보상형 마이크로콘의 개발)

  • Kim, Raehyun;Lee, Woojin;Yoon, Hyung-Koo;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4C
    • /
    • pp.163-174
    • /
    • 2009
  • Mechanical device using the load cell or strain gage sensor can be influenced by tempearute changes because temperature change can cause a shift in the load cell or straing gage output at zero loading. In this paper, micro cone penetrometers with 1~7mm in diameter, are developed by using an optical fiber sensor (FBG: Fiber Bragg Grating) to compensate the continous temperature change during cone penetration test. Note the temperature compensated method using optical fiber sensor which has hair-size in diameter, and is not affected by environmental conditions because the measured data is the wavelength shifting of the light instead of the intensity of the electric voltage. Temperature effect test shows that the output voltage of strain gage changes and increases with an increase in the temperature. A developed FBG cone penetrometer, however, achieves excellent temperature compensation during penetration, and produces continuous change of underground temperature. In addition, the temperature compensated FBG cone shows the excellent sensitivity and detects the interface of the layered soils with higher resolution. This study demonstrates that the fiber optic sensor renders the possibility of the ultra small size cone and the new fiber optic cone may produce more reliable temperature compensated tip resistance.

Compensation of Instantaneous Voltage Drop at AC Railroad System with Single-Phase Distributed STATCOM (전기철도 급전시스템의 순시전압강하 보상을 위한 단상 배전 STATCOM의 적용)

  • Kim, Jun-Sang;Lee, Seung-Hyuk;Kim, Jin-O;Lee, Jun-Kyung;Jung, Hyun-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.42-51
    • /
    • 2007
  • An AC electrical railroad system has rapidly changing dynamic single-phase load, and at a feeding substation, three-phase electric power is transformed to the paired directional single-phase electric power. There is a great difference in electrical phenomenon between the load of AC electrical railroad system and that of general power system. Electric characteristics of AC electrical railroad's trainload are changed continuously according to the traction, operating characteristic, operating schedule, track slope, etc. Because of the long feeding distance of the dynamic trainload, power quality problems such as voltage drop, voltage imbalance and harmonic distortion my also occur to AC electrical railroad system. These problems affect not only power system stability, but also power quality deterioration in AC electrical railroad system. The dynamic simulation model of AC electrical railroad system presented by PSCAD/EMTDC is modeled in this paper, andthen, it is analyzed voltage drop for AC electrical railroad system both with single-phase distributed STATCOM(Static Synchronous Compensator) installed at SP(Sectioning Post) and without.

Prevention of output current sub-harmonic oscillation using the Hybrid mode current control (하이브리드 모드 전류제어를 이용한 출력 전류 저조 파 발진 방지)

  • Oh, Seung Min;Lee, Jong Uk;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.3-4
    • /
    • 2017
  • 컨버터 제어를 위한 피크 전류 모드는 기존의 전류 모드 제어 기법에 비해 빠른 응답과 간단한 구조로 인해 많은 컨버터 애플리케이션에서 사용된다. 그러나 듀티가 0.5를 초과하면, 서브 하모닉 발진이 전류에서 발생한다. 이러한 현상을 방지하기 위해 제어기를 안정적으로 동작 할 수 있도록 보상 기울기를 추가 한다. 그러나 기울기 보상의 방법은 구조를 복잡하게 만들고 출력 전압이 가변적 일 때 때때로 기울기를 변화시켜야 하는 문제가 있다. 따라서 본 논문에서는 기울기 보상 없이 새로운 하이브리드 모드 전류 제어 방법을 제안한다. 밸리 전류 모드에서 트레일 링 에지 변조를 사용하는 제안 된 방법에서, 서브 하모닉 발진 문제는 쉽게 해결 될 수 있다. 제안 된 제어기는 Psim 시뮬레이션에 의해 검증된다.

  • PDF

Characteristics Analysis for Voltage, Current & Capacity of Condenser at Voltage Unbalance (전압 불평형시 콘덴서 전압, 전류, 용량 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.145-151
    • /
    • 2010
  • Voltage unbalance is regarded as a power quality problem of significant at the user application. Although the voltages are quite well balanced at the transmission system, the voltage level of utilization can be unbalanced due to the unequal system impedances and the unequal distribution of single phase loads. Capacitor is generally used for power-factor compensation and reducing harmonics of non linear load with reactor. If voltage unbalance exists, current unbalance is generated and it will be reflected in the capacity variance. When the reactor and condenser are used at the same location, generally its trouble rate is high. And it is very important checking out that how the variance of voltage, current and capacity of condenser is proceeded by the voltage unbalance. In this paper, we calculated that voltage, current and capacity of condenser are within the tolerance limit of official regulations in the event of voltage unbalance with/without reactor.

Analysis for Power Capacitor Characteristics by Linear and Non-linear Load Operation (선형 및 비선형 부하의 운전시 커패시터 동작 특성 분석)

  • Lee, Eun-Woong;Lee, Dong-Ju;Kim, Il-Joong;Kim, Jong-Gyeum;Park, Young-Jeen
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.22-25
    • /
    • 2008
  • 전력용 커패시터는 부하에 필요한 무효전력을 대신 공급함으로써 공급전력을 줄여 역률을 개선하시키고, 전압을 안정시키며, 손실의 저감으로 전원용량을 증대할 수 있는 등 여러 가지 장점을 가지고 있다. 그러나 전압 불평형과 같은 전기품질의 저하와 비선형 부하등과의 혼합 사용시 전압 및 전류 등의 증가로 인해 전기적인 스트레스를 받게 된다. 본 논문에서는 선형 및 비선형 부하의 사용시 역률 보상으로 운전되고 있는 커패시터가 어떤 특성변화를 나타내는지에 대해 유도성 부하와 컨버터 회로를 사용하여 모의를 실시하였다.

  • PDF

A Design of Charger IC for Li-Ion Battery (리튬-이온 배터리 충전 IC의 설계)

  • 이신우;임신일
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.895-898
    • /
    • 2003
  • 본 논문에서는 휴대폰에 사용하는 리튬-이론 배터리(Li-Ion battery)를 충전하기 위한 충전 IC 의 설계에 대해서 기술한다. 정전류(Constant Current)/ 정전압 (Constant Voltage) 방식을 이용하여 리튬-이론 배터리를 충전을 하였다. 이 충전 과정을 제어하기 위해서 일반적으로 사용되는 ADC, DAC 와 MICOM 을 사용하지 않고, hardwired control logic 을 이용하여 적은 면적을 가지고도 기존의 충전 과정을 수행하도록 하였다. 충전 IC 외부에 사용되는 저항들을 내부에 집적하여 사용하는 부품의 수를 현저히 줄였다. 충전기와 리튬-이온 배터리를 연결하는 선(wire)로 저항에 의한 전압강하(voltage drop)를 외부에서 보상할 수 있도록하여 리튬-이온 배터리가 가장 안정적인 전압인 4.2 V로 충전 될 수 있도록 하였다. 외부 온도 검사 블록에서 저항을 이용한 전압 분배를 사용하지 않고, 정전류원을 이용하여 외부 온도 변화를 측정할 수 있도록 하였다. 리튬-이온 배터가 전정류와 정전압으로 4.2 V로 충전 되었으며, 충전 IC 의 소비 전력은 37 mW(analog part)이다. 충전 IC는 0.6 ㎛ standard CMOS 공정을 이용하여 설계하였다.

  • PDF

Characteristic Analysis by the Position of Power Factor Compensative Condenser (역률 보상용 콘덴서 설치 지점에 따른 특성 해석)

  • Jeong, Jin-Gwan;Lee, Gyeong-Bae;An, Hu-Jae;Kim, Jong-Gyeum
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.748-749
    • /
    • 2008
  • 대용량 전동기에는 역률보상용 콘덴서와 리액터를 설치하여 부하역률을 개선하고 있다. 역률보상용 콘덴서의 기동리액터 전.후단 설치지점에 따른 특성변화를 해석한 결과 콘덴서를 기동 리액터 전단에 설치한 경우 기동시의 순간적인 콘덴서 돌입전류로 상용주파수 부근의 고조파(1,3,5차) 공진이 발생하여 이로 인한 과전압이 콘덴서와 직렬리액터에 반복적으로 인가되어 수명이 단축됨을 확인할 수 있었다. 기동초기에 발생하는 과전압을 저감하기 위해서 콘덴서 회로의 연결점을 기동리액터 후단에 설치한 결과 인가전압과 전류가 감소됨을 알 수 있었다.

  • PDF