• Title/Summary/Keyword: 전송선원

Search Result 29, Processing Time 0.026 seconds

Smart Care System on a Small Boat for an Effective Emergency Service (효과적인 응급대응을 위한 소형선박의 위치기반 스마트케어시스템)

  • Shin, Dong-Young;Lee, Byung-Mun
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.8
    • /
    • pp.59-68
    • /
    • 2012
  • The existing ship monitoring system currently in use has a limitation, which is that it can only identify a boat's location for finding a safe harbor or give an answer to a rescue signal. In addition to this, it is very difficult to add an expensive, more effective monitoring system to small boats because of their small infrastructure in comparison with large boats. Therefore, this study suggests that a new model could be required to better cater to the needs of small boats. The 'Smart Care System', based on location, is better able to monitor the boat and the crew of small boats in comparison with the existing ship monitoring system. Using biomedical data transmission equipment, it is able to survey and send biomedical data so that it can continuously monitor the crew's health. The boat has an intelligent interface device, which has the functions of GPS and attitude sensors, and a web based management system. We have conducted three experiments for the assessment of this system. The experiment of biological data transmission had a success rate of 98 percent, and the tests conducted for recognizing emergency situations also had a 98 percent success rate. In conclusion we confirmed the efficiency of this system.

Determination of Attenuation Collection Methods According to the Type of Radioactive Waste Drums (방사성폐기물드럼 종류별 감쇠보정방법의 결정)

  • Kwak, Sang-Soo;Choi, Byung-I1;Yoon, Suk-Jung;Lee, Ik-Whan;Kang, Duck-Won;Sung, Ki-Bang
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.309-317
    • /
    • 1997
  • The measured radioactivity of gamma-emitting radionuclides in each radioactive waste drum using the non-destructive waste assay method is underestimated than real radioactivity in radioactive waste drum because the gamma-rays are attenuated within the medium. Therefore, the measured radioactivity should be corrected for the attenuation of gamma-rays. For the correction of the attenuation of gamma-rays, the attenuation correction method should be applied differently by considering the distribution and density of medium in radioactive wastes drum generated from nuclear power plants. In this study, the model drums were fabricated for simulating five types of radioactive waste drums generated from nuclear power plant and the optimum methods of the attenuation correction were experimentally determined to analyze the activity of radionuclides in the waste drum accurately using the segmented gamma scanning system. With the determination of the attenuation correction methods from the experimental results the transmission method and the average density method for the miscellaneous waste drum, the transmission method and the differential peak absorption method for the shielded miscellaneous waste drum were used to measure the density of medium in waste drums. Also, the average density method and the differential peak absorption method for the spent resin drum, the paraffin solidified drum, and the spent filter drum were used.

  • PDF

Comparison of the Correction Methods for Gamma Ray Attenuation in the Radioactive Waste Drum Assay (방사성폐기물드럼 핵종분석에서 감마선 감쇠보정 방법들의 비교 평가)

  • Ji Young-Yong;Ryu Young-Gerl;Kwak Kyoung-Kil;Kang Duck-Won;Kim Ki-Hong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.3
    • /
    • pp.275-284
    • /
    • 2006
  • In the measurement of gamma rays emitted from the nuclide in the radioactive waste drum, to analyze the nuclide concentration accurately, it is necessary to use the proper calibration standards and to correct for the attenuation of the gamma rays. Two drums having a different density were used to analyze the nuclide concentration inside the drum in this study. After carrying out the system calibration, we measured the gamma rays emitted from the standard source inside the model drum with changing the distance between the drum and the detector. The measured values were corrected with the three kinds of gamma attenuation correction methode, as a results, the error was less than 10 % in the low density drum and less than 25 % in the high density drum. The measured activity in the short distance was more accruable than in the long distance. The transmission correction for the mass attenuation showed good results(very Low error) compared to the mean density and the differential peak correction method.

  • PDF

Designing a Blockchain-based Smart Contract for Seafarer Wage Payment (블록체인 기반 선원 임금지불을 위한 스마트 컨트랙트 설계)

  • Yoo, Sang-Lok;Kim, Kwang-Il;Ahn, Jang-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.7
    • /
    • pp.1038-1043
    • /
    • 2021
  • Guaranteed seafarer wage payment is essential to ensure a stable supply of seafarers. However, disputes over non-payment of wages to seafarers often occur. In this study, an automatic wage payment system was designed using a blockchain-based smart contract to resolve the problem of seafarers' wage arrears. The designed system consists of an information register, a matching processing unit, a review rating management unit, and wage remittance before deploying smart contracts. The matching process was designed to send an automatic notification to seafarers and shipowners if the sum of the weight of the four variables, namely wages, ship type/fishery, position, and license, exceeded a pre-defined threshold. In addition, a review rating management system, based on a combination of mean and median, was presented to serve as a medium to mutually fulfill the normal working conditions. The smart contract automatically fulfills the labor contract between the parties without an intermediary. This system will naturally resolve problems such as fraudulent advance payment to seafarers, embezzlement by unregistered employment agencies, overdue wages, and forgery of seafarers' books. If this system design is commercialized and institutionally activated, it is expected that stable wages will be guaranteed to seafarers, and in turn, the difficulties in human resources supply will be solved. We plan to test it in a local environment for further developing this system.

자율운항선박의 원격제어에서 통신 메시지 가시화 방법에 관한 기초연구

  • 김홍진;임정빈
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.11a
    • /
    • pp.89-91
    • /
    • 2022
  • 선원이 탑승한 선박을 육상 원격 제어자가 조종할 경우 현장의 항해사에게도 원격제어 상황이 공유될 필요가 있다. 이를 위해 육상에서 선박으로 전송되는 원격제어 명령을 가시화하는 방안에 관한 기초연구를 하였다.

  • PDF

Development of nuclear measurement system for gamma column scanning (증류탑 진단을 위한 방사선 응용계측기 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Jin, Jun-Ha;Jun, Jong-Kuj
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2619-2621
    • /
    • 2004
  • 감마선 또는 x-선 등 방사선을 이용한 구조물 진단은 산업전반에 걸쳐 널리 이용되고 있다. 기존의 x-선이나 Ir-192의 감마선 등을 이용한 비파괴검사는 용접부의 확인이나 구조물의 내부 결점 확인과 같이 국부적인 진단에는 유용하나 석유화학산업에서 반응물의 분리 또는 정제 등에 많이 사용되고 있는 증류탑의 내부진단 실험에는 적합하지 않다. 증류탑은 목적에 따라 직경이 $3{\sim}10m$, 높이 $10{\sim}100m$에 달하는 대형 장치로서 내부의 이상현상에 대한 정확한 진단은 공정 전체의 가동효율 최적화에 결정적인 영향을 끼친다. 밀봉 감마선원으로부터 방출된 방사선의 투과율 변화를 증류탑의 반대편에 설치한 방사선 검출기로 측정하여 수직밀도분포(vertical density profile)를 구하여 증류탑의 내부현상에 대한 정확한 정보를 얻을 수 있는데 이러한 작업을 자동으로 수행할 수 있도록 한 것이 자동 증류탑 검사장치이다. 증류탑 진단장치는 크게 방사선 계측 및 데이터 전송회로, 방사선원부와 방사선검출부의 구동장치 및 구동회로, 데이터 수집 및 제어장치 둥으로 구성되어 있으며, 증류탑 검사를 자동화하여 진단결과의 신뢰도와 재현성을 향상시켰다. 본 논문은 방사선원과 방사선 검출장치의 위치를 자동으로 제어하면서 방사선 계측결과를 전송시키는 장치의 개발에 관한 내용으로서 개발된 장치의 소개와 산업현장 적용의 예를 소개함으로써 기존의 비파괴검사기술로는 진단할 수 없는 대형 증류탑의 진단에 효과적인 방사선 응용 계측장치임을 보이고자 한다.

  • PDF

A Study of Gamma-ray Irradiation Effects on Commercially Available Single-mode Optical Fiber using Fiber Bragg Grating Sensor Systems (광섬유 브래그 격자 센서를 이용한 국내외 상용 단일모드 광섬유의 감마선 영향 연구)

  • Kim, Jong-Yeol;Lee, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2287-2292
    • /
    • 2012
  • In this study, $Co^{60}$ gamma-ray induced loss on Ge-doped single mode (SM) fiber has been measured. Gamma-ray is irradiated for 4 hours at the dose rate of 0.5 kGy/hr, 2 kGy/hr, 8 kGy/hr. Consequently, gamma-ray induced loss based on radiation effects in Ge-doped SM fiber occur significantly. Furthermore, dose rate effect was observed, that dose rate using the same total dose increased higher, then optical fiber loss increased more. Also annealing effect was observed, that the loss after irradiation, increased higher, then the recovery rate of loss was increased. This results are foreseen to be base data in the future radiation-hardened optical fiber study.

Ship safety management method using real-time ship operation data (실시간 선박 운항 데이터를 활용한 선박 안전관리 방안)

  • Seong-Phil Kang
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.11a
    • /
    • pp.284-285
    • /
    • 2022
  • 기존 선박의 안전관리는 선박의 선원들에 의해 많은 부분이 결정되었다. 하지만 최근 위성통신 기술의 발전에 따라 선박에 있는 다양한 센서 데이터를 육상으로 전송할 수 있게 되어, 데이터 기반의 선박 안전관리에 대한 수요가 높아지고 있다. 본 연구에서는 선박에서 데이터 수집을 통해 어떻게 안전관리를 할 수 있는지 알아보겠다.

  • PDF

A Study of Gamma-ray Irradiation Effects on Commercially Available Single-mode Optical Fiber (국내외 상용 단일모드 광섬유의 감마선 영향 분석 연구)

  • Kim, Jong-Yeol;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.564-567
    • /
    • 2012
  • Optical fibers are going to be used for telecommunication, image fibers, sensors under irradiation in nuclear power plants and various irradiation facilities. Especially, Temperature detection sensors using Raman light scattering, temperature or strain sensors using fiber gratings, magnet-optical sensors using photo-magnetic effect, are already commercialized. However, When fibers are exposed to ionizing radiation, color centers are formed in fibers which reduces their light transmission, and it is limited in applying under radiation environments. In this study, $Co^{60}$ gamma-ray induced optical attenuation on Ge-doped single mode(SM) fiber has been measured. Gamma-ray is irradiated for 4hours at the dose rate of 0.5kGy/hr, 2kGy/hr, 8kGy/hr. Consequently, gamma-ray induced loss based on radiation effects in Ge-doped SM fiber occur precisely. Furthermore, dose rate effect that the higher dose rate in the same total dose, the more increase loss of optical fiber and annealing effect that the higher the loss after irradiation, the more increase the recovery rate of the loss are observed in the fiber. This results plan to make use of bases in the study of the radiation-hardened optical fiber.

  • PDF