• Title/Summary/Keyword: 전선

Search Result 1,426, Processing Time 0.028 seconds

The Signal Distortion Due to the Electromagnetic Induction Inside a Cable (전선의 전자기유도 현상에 의한 신호 왜곡)

  • Jeong Ji-Min;Choi Seong-Jun;Kim Jung-Ho;Song Young-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.4
    • /
    • pp.251-255
    • /
    • 2004
  • Electric cables such as multi-interphone cables and ribbon cab]os are commonly used for data aquisition in the DC resistivity survey. In general, electromagnetic induction may occur in the electric cables when electric current flows through them. In case of using multi-interphone cables in the DC resistivity survey, electromagnetic induction could take place due to the entangled wires of the multi-interphone cables, when the current flows through them. Then, the electromagnetic induction may cause measured DC resistivity data to be distorted. In this study, a monitoring system with PXI (PCI Extention for Instrumentation) was constructed to examine signal distortion on the DC resistivity data, attributed to the electromagnetic induction. Common electric cables used in the DC resistivity survey were tested to observe the waveforms of the electric voltages. The waveforms measured were compared to examine signal distortion due to the electromagnetic induction. The results may provide information on the resistivity data obtained using different electric cables in the DC resistivity survey. The distortion of waveforms attributed to the electromagnetic induction wat not observed when using ribbon cables for DC resistivity data aquisition, while the distortion were observed when using multi-interphone. Therefore, the ribbon cables provide better quality of data than other cables in the DC resistivity data aquisition.

The Properties Analysis of 600V Grade Polyvinyl Chloride Insulated Wire with Variation of Thermal Stress (열적 스트레스 변화에 따른 600V 비닐절연전선의 특성 분석)

  • 최충석
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.108-115
    • /
    • 2001
  • In this paper, we analyzed the properties change of electric wire when the thermal stress was applied to 600V grade polyvinyl chloride insulated wire (IV). In the structure analysis, normal wire has the properties of direction on the surface, but in case of deteriorated wire at above $400^{\circ}c$, it formed the carbide, the crack and the crystal. The surface composition rate of normal wire was Cu : 100%, but the section composition of the deteriorated wire at $800^{\circ}c$ showed Cu : 78.89%, O : 21.11%. In result of analyzing the differential scanning calory of copper wire, the new reaction peak was observed on the deteriorated wire at above $700^{\circ}c$. In case of the deteriorated wire as $150^{\circ}c$ at the differential thermal analysis, an endothermic reaction appeared at $264^{\circ}c$ lower than the reactive point of normal wire. The occupation rate of oxygen according to the deterioration of copper wire is about 20% at $500^{\circ}c$.

  • PDF

A Study on Designs for the Pulley and Electric-wire for 'HELLO' Artwork at Incheon Airport Terminal 2 (인천공항 제2여객터미널 'HELLO' 작품의 풀리와 전선의 디자인에 관한 연구)

  • Kang, Hee-Ra
    • Journal of Digital Convergence
    • /
    • v.16 no.10
    • /
    • pp.415-420
    • /
    • 2018
  • This study focused on the designs for the pulley and electric cables for Hello, the artwork displayed at the Great Hall at the Incheon International AirportTerminal 2. This study presented designs for the pulley and cables, and the parts were applied and tested to analyze their durability and problems. Improvements were made for the final production of the work and three samples were produced respectively for the designs of the pulley and the cables. As are sult, this study found that for the pulley, the most efficient design was to fix the cables at its center. In the case of cables, it was most efficient touse flat cables with a wire in the core. These designs were applied to the artwork Hello, which is currently installed at the Great Hall at the Incheon International Airport Terminal 2. Future research will be conducted to make further improvements to the cable sand the pulley.

The Study on Demage Mechanism Analysis of Insulation wire on the Line Post Insulator Using 22.9 kV-Y Overhead Distribution Line (22.9kV-Y 가공선로 지지애자에서의 절연전선의 손상 메커니즘 규명 연구)

  • Lee, Byung-Sung;Park, Chul-Bae;Na, Dong-Chae;Lee, Jae-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2081_2082
    • /
    • 2009
  • 국내 가공배전 선로는 절연전선을 사용하고 있으며, 절연을 위해 세라믹 재질과 폴리머 재질의 지지애가가 사용되고 있다. 지지 애자 위의 전선은 진동에 따라 종방향 및 횡방향의 기계적 마찰력을 받고 있으며, 전기적으로 누설전류 및 서지의 영향을 받아 절연피복이 손상된다. 본 연구에서는 지지애자를 통해 흐르는 누설전류에 의해 전선이 손상되는 메커니즘을 규명하여 고장을 예방하고자 하였다. 절연전선은 손상된 부위에서 전류가 집중되어 내부 도체가 용융 단선되었다. 전선단선에 영향을 주는 열화 인자로서 지지애자의 표면 열화상태, 절연전선 피복 손상, 바인드선의 종류 등이 복합적으로 작용하였다.

  • PDF

The Characteristic Analysis of breaking failure on ACSR-OC Conductor (알루미늄 절연전선의 단선고장 특성 분석)

  • Kim, Dong-Myung;Ra, Dong-Chae
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.185-187
    • /
    • 2008
  • ACSR-OC 전선은 알루미늄, 아연 및 철 등 세 가지 금속이 서로 접촉되는 이질구조이므로 도체 내에 전해질의 수용액이 존재할 경우 전해부식이 일어나기 쉽고 표면이 손상되었을 경우는 서지의 고정점으로 작용하여 단선될 우려가 있다. Al 절연전선이 염분에 의해 발생되는 변화를 살펴보았다. 시료는 10년이상 현장에서 사용한 후 천거한 전선과 신품에 대해 기계적 강도시험(KSC 3113의 5.4.3 (인장하중시험)), 소선의 성분분석(SEM) 및 현미경 관찰을 실시하였다. 실험결과, 철거전선 표면에서는 알루미늄 외 산소, 염소(Cl), 나트륨(Na) 등이 관찰되었으며 소선은 부식 또는 진행 중이어서 전선의 인장력이 저하되어 있었다. 또 표면이 손상된 전선에 대해 파괴시험, 현미경 관찰 등을 실시하여 절연에 미치는 영항을 조사하였다.

  • PDF

전선 산업의 발전-초고압 케이블의 국산화-

  • 이충호
    • 전기의세계
    • /
    • v.46 no.7
    • /
    • pp.72-74
    • /
    • 1997
  • 1887년 우리나라에서 처음 전기를 사용하기 시작한 이래 초기에는 모든 송배전 선로의 전선은 수입에 의존해야 했으며, 가공 송배전이 주축을 이루었던 시절이었으나, 현재에는 전기에너지의 전달 수단으로써 전선은 꾸준한 발전을 이룩하여 국내에서 소요되는 전선량의 대부분을 국내 생산으로 충족하고 있는 실정이다. 우리나라 전선의 국산화는 1955년 국내 최초의 전선업체인 대한전선(주)이 설립되면서부터 시작되었으며, 그 이후 자체 연구개발 및 해외로부터의 기술도입에 박차를 가하게되고, 이를 계기로 송배전 선로의 지중화 즉, 케이블화가 시작된 것이다. 국내에 최초로 수입된 지중배전선로가 운전을 개시한 1929년 이후 40여년 만인 1970년에 국내 최초의 국산 지중배전선로가 포설, 운전하기에 이르렀고, 이렇게 축적된 기술을 기반으로 하여 1971년 수입 포설된지 불과 7년 후인 1978년 국내최초로 국산 초고압케이블이 개발.시공.운전하기에 이르렀다. 이로써 케이블 국산화는 가일층 증가 일로에 있었으며, 현재는 산업의 동맥으로써 중요한 역할을 담당하고 있다.

  • PDF

회원사 동향

  • Korea Electrical Manufacturers Association
    • 전기산업
    • /
    • v.8 no.2
    • /
    • pp.89-95
    • /
    • 1997
  • PDF

회원사 동향

  • Korea Electrical Manufacturers Association
    • 전기산업
    • /
    • v.7 no.3
    • /
    • pp.83-89
    • /
    • 1996
  • PDF

가공배전선의 절연화와 보호계전방식

  • 이광우
    • 전기의세계
    • /
    • v.29 no.9
    • /
    • pp.551-560
    • /
    • 1980
  • 본고의 내용은 다음과 같다. 1. 절연전선의 구조 2. 절연전선의 사고특징 3. 절연전선의 단선 및 낙하방지 4. 고장보호 계전방식 5. 검토

  • PDF