• Title/Summary/Keyword: 전산화단층촬영수치

Search Result 22, Processing Time 0.035 seconds

Effect of Different CT Scanner Types and Beam Collimations on Measurements of Three-Dimensional Volume and Hounsfield Units of Artificial Calculus Phantom (인공결석모형물의 부피와 하운스필드값 측정에 대한 전산화단층촬영기기의 타입과 빔 콜리메이션의 영향)

  • Wang, Jihwan;Lee, Heechun
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.495-501
    • /
    • 2014
  • The objective of this study was to evaluate the differences and reproducibility of Hounsfield unit (HU) value and volume measurements on different computed tomography (CT) scanner types and different collimations by using a gelatin phantom. The phantom consisting of five synthetic simulated calculus spanning diameters from 3.0 mm to 12.0 mm with 100 HU was scanned using a two-channel multi-detector row CT (MDCT) scanner, a four-channel MDCT scanner, and two 64-channel MDCT scanners. For all different scanner types, the thinnest possible collimation and the second thinnest collimation was used. The HU values and volumes of the synthetic simulated calculus were independently measured three times with minimum intervals of 2 weeks and by three experienced veterinary radiologists. ANOVA and Scheff$\acute{e}$ test for the multiple comparison were performed for statistical comparison of the HU values and volumes of the synthetic simulated calculus according to different CT scanner types and different collimations. The reproducibility of the HU value and volume measurements was determined by calculating Cohen's k. The reproducibility of HU value and volume measurements was very good. HU value varied between different CT scanner types, among different beam collimations. However, there was not statistically significant difference. The percent error (PE) decreased as the collimation thickness decreased, but the decrease was statistically insignificant. In addition, no statistically significant difference in the PEs of the different CT scanner types was found. It can be concluded that the CT scanner type insignificantly affects HU value and the volumetric measurement, but that a thinner collimation tends to be more useful for accurate volumetric measurement.

Analysis of the O-Ring Deformation Behavior by the Computed Tomography (전산화 단층촬영에 의한 오링 변형 거동 분석)

  • Kim, Dong-Ryun;Kim, Jae-Hoon;Park, Sung-Han;Lee, Hwan-Gyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • The object of this study is to develop the examination technique for measuring the O-ring deformation behavior under the pressure and the squeezed condition simultaneously. The O-ring deformation measuring device in which two grooves were dug to insert the two O-rings was manufactured to be not deformed under the high pressure and the 1 mm and 0.1 mm gap were designed to measure the extrusion lengths under the internal pressure. The beam hardening correction, the histogram analysis and the dead zone correction were executed to exactly measure the shape of O-ring deformation and the lengths of the O-ring deformation were measured by the LSF and the ERF. The computed tomography applied the pressure of 0, 1.378, 4.902, 9.804, 15.692 MPa at 22.3% squeezed condition and the expanded diameter, contact length and extrusion depth were measured in each pressure. The shape of O-ring deformation was evaluated by the FEM to verify the results of measuring by the computed tomography and the area of O-ring was mutually compared to the area measured by the computed tomography.

Analysis of Coronary Artery Atheromatous Plaque by Cardiac Computed Tomographic Angiography : Retrospective Analysis of Intravascular Ultrasound Results (심장전산화단층촬영을 이용한 관상동맥 죽상경화반의 분류 : 혈관내초음파 결과를 통한 후향적 분석)

  • Choi, Jae-Sung;Han, Jae-Bok;Choi, Nam-Kil
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.349-356
    • /
    • 2012
  • In the diagnosis of coronary artery atheromatous plaque, Cardiac computed tomography (Cardiac Computed Tomographic Angiography: CCTA) compared with IVUS(Intravascular Ultrasound: IVUS) investigate the diagnostic accuracy, Interested in CCTA atheromatous plaque in computed tomography values (Hounsfield Unit: HU) try to find out. From April 2006 to August 2008 among coronary artery disease(Coronary Artery Disease: CAD) patients with confirmed or suspicious of CAD by CCTA performed atherosclerotic plaques and found 200 patients who underwent IVUS were enrolled. 200 patients who underwent CCTA and IVUS results from the 476 plaque was found, IVUS results of the soft plaque(n; 84), fibrous plaque(n; 63), mixed plaque (n; 97), calcific plaque(n; 232). The results are classified according to the IVUS plaque in HU in the soft plaque : $53.8{\pm}10.5$, fibrous plaque : $108.1{\pm}20.0$, mixed plaque : $371.2{\pm}113.1$, and calcific plaque : $731.0{\pm}160.4$. CCTA had sensitivity of 97% and confidence interval of 95.0-98.3. This study that is the diagnosis of coronary atheromatous plaque for using CCTA, we confirm the high sensitivity and the confidence interval Based on IVUS results CCTA atheromatous plaque with HU in the analysis could be classified to characterize in the treatment of patients with CAD is expected to help.

Geometric Assessment of Scapular Thickness by Computed Tomography (견갑골 두께의 전산화 단층 촬영을 이용한 기하학적 모델)

  • Yoo, Jeong Hyun;Chung, Soo Tai;Park, Sang Jun;Chang, Jun Hee;Paik, Doo Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.73-78
    • /
    • 2012
  • Purpose: Understanding exactly detailed anatomy and morphology of scapula is very important for further surgical procedures. This study was intended to provide accurate anatomic and morphologic information of scapula by exactly measuring scapular thickness using computed tomography and reconstructing its geometric model. Materials and Methods: Eight average lengths and two angles of 102 scapular structures obtained from 51 cadavers were generally measured by computed tomography. Also, to measure the scapular thickness, sagittal planes of each scapula were divided almost equally and the thicknesses of each sagittal plane was measured by computed tomography. After measuring every thickness, average results were calculated and the gender difference was compared by Student t-test. Results: Average results of the thickness of glenoid fossa, lateral border, medial border, and the middle 1/3 portion of the scapular body were 22.4 mm, 13.83 mm, 4.44 mm and 2.06 mm, respectively. Also, male scapulars were found to be significantly thicker than female. Based on these measured thicknesses, we reconstructed the 3-dimensional geometric model of scapula. Conclusion: From these results, glenoid fossa and lateral border were the thickest part of scapula, while the middle 1/3 portion of the scapular was the thinnest.

Comparison of CT Image Performance with or without Tin Filter based on Blind Image Quality Evaluation Method (블라인드 품질 평가 방법을 사용한 주석필터 사용 유무에 따른 CT 영상 특성 비교)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.301-306
    • /
    • 2021
  • The use of tin filters as a way to reduce the medical radiation in computed tomography (CT). However, due to the changed X-ray spectrum with the use of tin filters, disease diagnosis could be affected because it appears as images of different impressions from previous images. Therefore, this study evaluates the changes in images when using tin filter and high pitch in chest low-dose CT. In this study, images were acquired in groups of three for comparison. Group 1 did not apply to tin filter, and used the existing pitch 0.8. Group 2 used a tin filter, pitch 0.8, Group 3 used a tin filter, and pitch 2.5. To compare the image quality, the natural image quality evaluator (NIQE) and the blind/referenceless image quality evaluator (BRISQUE) were used among the blind quality evaluation factors depended on a no-reference basis. As a result, the NIQE values were low in the order of Group 1, Group 3, and Group 2. BRISQUE values were low in the order of Group 3, Group 2 and Group 1. This study confirms the superiority of images of tin filter and high pitch techniques in chest low-dose CT, which is considered to be a fundamental study for acquiring accurate images of patients with difficult breathing control.

Evaluation of Bonwill triangle using cone beam computerized tomography in Korean (콘빔형 전산화단층영상을 이용한 한국인의 본윌 삼각에 대한 평가)

  • Kong, Hyun-Jun;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.97-103
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the Bonwill triangle of Korean using the cone beam computerized tomography (Cone-beam CT). Materials and Methods: 120 Koreans (60 males and 60 females) who visited Daejeon Dental College Hospital of Wonkwang University and who underwent the Cone-beam CT were selected. The Cone-beam CT images were analysed with Invivo 5.1 (Anatomage, San Jose, USA). After reorientation of axis, the intercondylar distance was measured by clicking both middle points of condyle. And the condyle-incisor distance was measured by clicking the middle point of condyle and contact point of the mandibular central incisor's incisal edge. The collected data were analysed using the SPSS Version 23.0 (IBM Inc., Armonk, USA) and statistical significance was verified by gender using independent t-test. Results: The mean intercondylar distance of Korean was 105.9 mm, and the male (108.3 mm) was statistically significantly larger than the female (103.4 mm). The mean condyle-incisor distance of Korean was 105.2 mm, and the male (108.1 mm) was statistically significantly larger than the female (102.3 mm). Conclusion: The mean intercondylar distance of Korean in this study was 105.9 mm that was smaller than well-known 110 mm of Caucasian and the male was statistically significantly larger than the female. Within the limitations of this study, it would be necessary to use the articulator which can adjust the intercondylar distance according to the individual for prosthodontic treatment of Korean.

Comparison Study with Pain Assessment Tools of Pain Measurement in Children for Intravenous Catheter Placement in the Computed Tomography (CT 검사에서 소아 환자의 정맥 카데터 삽입 통증에 대한 측정 도구 비교)

  • Kweon, Dae-Cheol;Jang, Keun-Jo
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.2
    • /
    • pp.205-212
    • /
    • 2008
  • Needle phobia of medical devices is a significant problem in children patients. We conducted study in 130 pediatric patients aged $8{\sim}13$(mean age 10.5) who had venipuncture performed in a computed tomography. This review aims to explore the research available relating to three commonly used pain rating scales of children, the visual analogue scale(VAS), numeric pain rating scale(NPRS) and Wong-Baker faces pain scale(WBFPS) with scores. Its validity is supported by a strong positive correlation with the three-pain rating scales(correlations ranging from 0.70 to 0.92) measure in children. There were no significant differences between the means on the VAS and either of the pain rating scales. It has the advantage of being suitable for use with the most widely used metric for scoring($0{\sim}10$), and conforms closely to a linear interval scale. These scales presented moderate to good correlation and moderate agreement, sufficient for valid use in children. All three pain-rating scales are valid, reliable and appropriate for use in intravenous catheter placement.

The Usefulness of the Abdominal Computerized Tomography for the Diagnosis of Childhood Obesity and Its Correlation with Various Parameters of Obesity (소아 복부비만 진단을 위한 복부 전산화 단층 촬영의 유용성과 여러 지표와의 상관성 연구)

  • Shim, Yoon Hee;Cho, Su Jin;Rhyu, Jung Hyun;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.10
    • /
    • pp.1082-1089
    • /
    • 2005
  • Purpose : Abdominal obesity is encountered as a risk factor for cardiovascular diseases. However, the anthropometric cut-off value to estimate the cardiovascular risk, has not been suggested. This study was designed to find the relationship between the abdominal fat and various parameters of obesity to find the cardiovascular risk factors related to abdominal obesity and to establish practical methods to measure them. Methods : Twenty seven obese Korean adolescents of moderate to severe degree and 22 healthy adolescents were enrolled. The body mass index(BMI), arm circumference and skinfold thickness were measured. Furthermore, blood lipid, sugar, insulin and four different cytokines' levels were checked and the distribution of body composition was measured by bioelectrical impedance analysis. The subcutaneous and intra-abdominal fat thickness by abdominal ultrasonography(US) and the total and intra-abdominal fat area by abdominal computerized tomography(CT) were measured in the obese group. Results : The most accurate method to measure abdominal fat in children is abdominal CT and the fat mass measured by bioelectrical impedance was strongly correlated with it(r=0.954). It was also correlated with arm circumference, fat thickness measured by abdominal US, BMI, aspartate aminotransferase(AST), alanine aminotransferase(ALT) and triglyceride level. Conclusion : Abdominal CT is the most accurate method to measure intra-abdominal fat, and it can be replaced by abdominal US for cost effectiveness. The screening methods that can be used at school or in outpatient basis include bioelectrical impedance, waist/hip ratio, and arm circumference. The cardiovascular risk factors include leptin, triglyceride and insulin level.

An evaluation of curve of Spee using cone beam computerized tomography in Korean (한국인에서 콘빔형 전산화단층영상을 이용한 스피만곡 평가)

  • Oh, Sang-Chun;Kim, Seul-Gi;Kim, Yu-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.93-101
    • /
    • 2014
  • Purpose: The aim of this study is to investigate the typical shape of the curve of Spee in Korean and analyze the curve of Spee according to gender, age, and left and right. Materials and Methods: Among the patient of Wonkwang University Sanbon Dental Hospital taking cone beam computerized tomography, the images of 500 Koreans (311 males and 189 females) who qualifies the criteria of this study were selected and their curve of Spee were analysed in sagittal plane. Results: The mean radius of curve of Spee in Korean was 91.4 mm. There was statistically significant difference between male (94.6 mm) and female (86.1 mm) by gender, but not significant differences by age and between right and left side. Conclusion: Within the limitation of this study, the smaller radius (91.4 mm) of Korean than the 4-inch (101.6 mm) value advocated by Monson was meaned that it would be need to reconsider the application of the curve of Spee in all cases when occlusal plane is reconstructed in Korean.

Significance of the AFP Level and HBsAg in Differentiation of Hepatic Masses (간종괴의 감별진단에 있어서 AFP수치와 HBsAg의 의의)

  • Kim, Jae-Woon;Park, Won-Kyu;Cho, Jae-Ho;Chang, Jae-Chun;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.2
    • /
    • pp.302-307
    • /
    • 1996
  • Hepatic masses show different enhancing patterns in IV bolus computed tomography: Hepatocellular carcinoma shows high-attenuation in the early enhancing phase and low-attenuation in the late enhancing phase, hemangioma shows peripheral dot-like high-attenuation in the early enhancing phase and central high-attenuation in the late enhancing phase, and metastatic cancer and cholangiocelluar carcinoma show peripheral high-attenuation rim in the early enhancing phase and central portion gradulally high-attenuation in the late enhancing phase. but sometimes enhancing patterns of the hepatic masses are confuse. To evaluate the significance of the AFP level and HBsAg in differentiation of the hepatic masses, we retrospectively analyzed AFP level and HBsAg in 228 pathologically or radiologically confirmed hepatocellular carcinomas, and 137 pathologically nonhepatocellular cacinomas. The results were as follows : In hepatocellular carcinoma, AFP level above 20ng/ml was 77.8% and HBsAg positve was 72.6%. In nonhepatocellular carcinoma, AFP level above 20ng/ml was 3.7% and HBsAg positve was 16.1%. We concluded that AFP level and HBsAg are helpful to distinguish hepatocellular carcinoma from nonhepatocellular carcinoma, when IV bolus computed tomogram finding is uncertain.

  • PDF