• Title/Summary/Keyword: 전리전류

Search Result 28, Processing Time 0.027 seconds

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF

Comparative Measurement of Radioactivity with Standard Gamma-ray Ionization Chamber System (표준 감마선 전리함 장치에 의한 방사능 비교 측정)

  • Park, Tae-Soon;Woo, Dong-Ho;Oh, Pil-Jae;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.1
    • /
    • pp.11-18
    • /
    • 1984
  • A Standard gamma-ray ionization chamber system was developed with a well type ionization chamber and micro current measuring circuit. Micro current was measured by the automatic Townsend balance with stepwise compensation method. For gamma emitting nuclides such as $^{241}Am,\;^{133}Ba,\;^{60}Co,\;^{134}Cs,\;^{137}Cs,\;and\;^{22}Na$ relative calibration factors to $^{226}Ra$ reference source were calculated and detection .efficiency curve was determined as a fudnction of gamma energy.

  • PDF

Development of Neutron Sensitive PCP ionization Chamber

  • Lee, Hee-Young;Kim, Jin-Kon
    • Nuclear Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.27-35
    • /
    • 1974
  • A neutron sensitive ionization chamber has been successfully developed by an improved technique for reactor instrumentation. This instrument is 50mm in diameter and 87cm in length, and can yield a current of 14$\mu$A when in a neutron flux of around 10$^{9}$ nv. The normally required voltage is +350v. The instrument may be removed from operating flux and disassembled immediately without special precautions from radiation.

  • PDF

A Fabrication and Properties of Ionization Chamber Using Madium Exposure Rate (중준위 조사선량율 측정용 전리함의 설계 및 특성)

  • Woo, Hong;Kim, Sung-Hwan;Kang, Hee-Dong
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.29-40
    • /
    • 1996
  • We had designed and made the cylindrical ionization chamber which operated above 5 mR/h. Using commercial electrometer, we investigated the characterictic of charge collection in the ion chamber. The active volume was 190.4㎤ and overall length and diameter in the chamber was 15.5cm, 5.22cm, respectively. The chamber had three electrodes(inner, central, wall electrode). And background current was 8.39${\times}$10$\^$-14/${\pm}$1.5${\times}$10$\^$-15/A to arrange the electrodes which were coaxial in chamber axis. The collection efficiency of chamber for Cs$\^$137/ was 99.7% when the opreating voltage was applied 400V. Comparing with the commertial dosimetry system, the exposure calibration constant was 4.531${\times}$19$\^$7/R/C. By normalizing to CS$\_$137/ the relative energy response of the chamber was 1.30 for Am$\_$24/, 1.05 for C0$\_$60/, respectively. When the irrarition tranversed to the chamber axis, the isotropic effect of the chamber was not considerable.

  • PDF

Exposure Measurements of Co-60 Gamma rays (Co-60 감마선의 조사선량 측정)

  • Hah, Suck-Ho;Kim, Hyun-Moon
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.7-16
    • /
    • 1991
  • Measurement of Co-60 gamma rays has been made for establishment of exposure standard and analyze it's overall uncertainties. Exposure rate determined by the charge mode method using vibrating reed amplifier with cylinderical type cavity chamber. The values of a variety of physical constants and the correction factors are evaluated. The resulting exposure rate is 690.81 R/h at the distance of 1m from the source and the related uncertainties is ${\pm}0.8%$

  • PDF

Semi-Microseoond Long pulse KrF 레이저 시스템 개발

  • 박홍진
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.13-16
    • /
    • 1990
  • 코로나 예비전리를 이용한 KrF 레이저의 장펄스화를 위해 동축형 4단 펄스정형회로 (PFN)를 구성해서 용량이행형의 회로에 인덕턴스가 부가된 방식의 전류, 전압을 비교하여 PFN을 동축형으로 제작함으로 인한 Stray Capacitance (Cs)의 존재로 인해 좋은 효율의 장펄스화를 이루어짐을 밝혔다. 구성된 PFN을 절연유에 넣어 충전전압 15kV, N2 55Torr에서 330ns 펄스폭의 전류파형을 측정했다.

  • PDF

기체방전에서 전자 Avalanche의 관측

  • 이동인
    • 전기의세계
    • /
    • v.29 no.6
    • /
    • pp.349-353
    • /
    • 1980
  • 본고에서는 기체중에서 전자의 전이과정을 관찰하기 위하여 많이 적용되어지는 방법에 대해서 기초적인 사항만 언급을 하였으나 이러한 technique를 사용함으로써 전하의 공간적인 분포상태를 파악할 수 있으며 avalanch의 전자나 이온의 이동으로 인하여 외부회로에 전류를 발생시키는데 이것은 amplifier와 oscilloscope에 의하여 측정을 할 수 있다. 또한 인가한 전계의 작용으로 전자가 양극으로 이동할 때 충돌전리작용에 의하여 새로운 전자를 생성할 뿐만 아니라 여기방사작용에 의하여 광자를 생성시킨다. 이러한 광자는 photomultiplier나 image-intensifier를 사용하므로써 감지할 수 있다. 이러한 결과로부터 우리는 전이현상의 기본적인 Data 즉 전자, 양이온 및 음이온의 이동속도, 전리계수 .alpha.와 부착계수 .eta.등을 유도할 수 있다.

  • PDF

중이온가속기 진공도 요구조건에 대한 고찰

  • In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.100.1-100.1
    • /
    • 2015
  • 중이온가속기에서 잔류기체 분자와 가속 이온의 충돌이 발생하면 이온빔 전류의 손실을 야기하는 직접적인 효과 외에 잔류 기체분자 중에서 전리된 이온들이 반발력에 의해 용기 벽에 부딪힐 때 표면에 흡착되어 있던 기체분자들을 충격탈리(stimulated desorption)시킨다. 더 심각한 경우는 산란된 고속 이온이 용기 벽과 충돌하면서 핵반응을 일으켜 방사화 시키거나 벽에서 다량의 기체를 방출시키는 것이다. 최악의 경우에는 고속이온의 에너지에 의해 용기벽이나 부품들이 열적인 손상을 입을 수도 있다. 현재 설계 및 연구개발이 진행중인 기초과학원(IBS) RISP (Rare Isotope Science Project)의 RAON 중이온가속기는 입사기에서 실험영역까지 각 부분의 진공도 조건이 일반적으로 10-8~10-9 mbar 대에 있어서 이온빔 전류의 손실이나 전리 이온들에 의한 충격탈리는 무시할 수도 있지만 고속이온의 기체방출 수율이 ~104 정도로 높은 것을 감안할 때 고속이온의 충격탈리에 의한 압력 증가가 감내할 수준인지 검토할 필요가 있다. 압력증가는 추가적인 손실을 유발하고 이것은 다시 압력을 상승시키는 진공 불안정성(vacuum instability)을 야기할 수 있다는 축면에서 조심하는 것이 좋다고 판단된다. 고속 중이온과 잔류기체 분자와의 충돌에서 이온이 손실되는 반응에는 쿨롬(coulomb) 산란과 전하교환(charge exchange)이 있는데 전자는 후자에 비해 일반적으로 1/10000 가까이 낮아서 무시할 수 있고, 전자 포획(electron capture) 또는 전자 손실(electron loss, 이온의 전리에 해당)로 대별되는 전하교환 반응이 이온 손실을 주도하는 것으로 알려져 있다. 이 연구에서는 다양한 전하교환 반응 단면적을 아우르는 비례칙(scaling law)을 사용하여 대표적인 중이온인 U33+ 및 U79+의 손실 및 잔류 기체의 전리율을 계산하고 충격탈리에 의한 표면방출 및 압력상승을 일차적으로 고려하여 진공도 조건의 타당성을 입증하려고 한다.

  • PDF