• Title/Summary/Keyword: 전류 왜곡

Search Result 220, Processing Time 0.031 seconds

A Study on the Harmonics Simulation of the High Speed Electric Train Loads by Field Tests (현장시험에 의한 고속전철 부하의 고조파 시뮬레이션에 관한 연구)

  • Kim, Kyung-Chul;Kim, You-June
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.40-47
    • /
    • 2007
  • High speed electric trains have nonlinear loads including converters and inverters for the control synchronous motors. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probablistic approach is the most commonly used method to solve time varying harmonics. Harmonic simulations are performed to evaluate the harmonic voltage and current distortions throughout the system. This paper provides an in depth analysis on harmonics field measurement of the high speed electric train loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519-l992, and harmonics simulation using EDSA program for the case study.

Power Quality Analysis of Jeju System Considering HVDC Overhaul and Wind Turbines (HVDC Overhaul 및 풍력발전을 고려한 제주계통 전력품질 분석)

  • Chae, Woo-Kyu;Yoon, Gi-Gab;Kim, Jae-Eon;Han, Ji-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.132-140
    • /
    • 2008
  • Power system of Jeju is interconnected to the mainland using HVDC and that is also interconnected two wind farms. Control of Jeju power system will be difficult if HVDC is disconnected or HVDC is overhauled under large scale wind farms interconnected. We measured and analysed the power quality of two substation and two wind farms to assess that wind farms and HVDC overhaul have an effect on Jeju system or not during the HVDC overhaul. We found that the frequency of Jeju system is very unstable and the voltage distortion excess the limitation. Harmonic currents of wind farms flew into Jeju system in proportion to the power of wind turbine. And the voltage of nearby distribution line was distorted by power of wind turbine when the amount is more that 3,000[kW].

Numerical Analysis of a Two-Dimensional N-P-N Bipolar Transistor-BIPOLE (2차원 N-P-N 바이폴라 트랜지스터의 수치해석-BIPOLE)

  • 이종화
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.2
    • /
    • pp.71-82
    • /
    • 1984
  • A programme, called BIPOLE, for the numerical analysis of twotimensional n-p-n bipolar transistors was developed. It has included the SRH and Auger recolnbination processes, the mobility dependence on the impurity density and the electric field, and the band-gap narrowing effect. The finite difference equations of the fundamental semiconductor equations are formulated using Newton's method for Poisson's equation and the divergence theorem for the hole and electron continuity equations without physical restrictions. The matrix of the linearized equations is sparse, symmetric M-matrix. For the solution of the linearized equations ICCG method and Gummel's algorithm have been employed. The programme BIPOLE has been applied to various kinds of the steady-state problems of n-p-n transistors. For the examples of applications the variations of common emitter current gain, emitter and diffusion capacitances, and input and output characteristics are calculated. Three-dimensional representations of some D.C. physical quantities such as potential and charge carrier distributions were displayed. This programme will be used for the nome,rical analysis of the distortion phenom ana of two-dimensional n-p-n transistors. The BIPOLE programme is available for everyone.

  • PDF

A Study on the Inverter Type Neon Power Supply Using a Piezoelectric Transformer (압전 변압기를 이용한 인버터식 네온관용 변압기에 관한 연구)

  • 변재영;김윤호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.504-511
    • /
    • 2003
  • In this paper, inverter type neon power supply using a piezoelectric transformer is fabricated and its characteristic is investigated. Developed neon power supply is composed of basic circuit and blocks, such as rectifier part, frequency oscillation part and piezoelectric transformer and resonant half bridge inverters. In this paper for complement the low power limitation, piezoelectric transformer at parallel connected driving by inverter is studied for noon tubes system of high power. When piezoelectric transformer is connected with parallel, LC filter connection method with parallel and selection of inductance L and capacitor C of primary side is suggested for reduce unbalanced current at the terminal of each transformer. Piezoelectric transformers use piezoelectric ceramic devices. Thus it is wireless therefore it has high power density, high Isolation level, low loss, more light, and miniaturization. In addition, high voltage transfer ratio is expected because there is no leakage inductance. Also, it has economic merit that the electrical loss Is low because structure is simple, small and tighter weight.

Three-Parallel System Operation and Grid-Connection Technique for High-Power Wind Turbines using a PMSG (PMSG를 이용한 풍력 발전 시스템의 3병렬 운전과 계통 연계 기술)

  • Lee, Sang-Hyouk;Jung, Hea-Gwang;Lee, Kyo-Beum;Choi, Se-Wan;Choi, Woo-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.296-308
    • /
    • 2010
  • This paper proposes a design of the three-parallel converter system and grid-connection technique for a PMSG based wind turbine systems. The back-to-back converter of the PMSG based wind turbine system is directly connected to the grid so that both the power devices and the filters are needed to have large power ratings. The three-parallel converter configuration can reduce the required power ratings of the devices and filters. However, the three-parallel converter can cause circulating currents. These circulating currents can be suppressed by sellecting proper inner inductance at each leg. An LCL filter design is used to meet the THD regulations. The latent resonance caused by the LCL filter is compensated by an active damping method without additional loss. The decline of the power quality caused by the unbalanced and distorted grid voltages is also compensated with an additional compensation algorithm. The simulation and experimental results show that the proposed system and compensation methods are effective for the wind turbine systems.

An Integrated Single-Stage Zero Current Switched Quasi-Resonant Power Factor Correnction Converter with Active Clamp Circuit (능동 클램프 회로를 적용한 단상 ZCS 공진형 역률개선 컨버터)

  • 문건우;구관본;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.539-546
    • /
    • 1999
  • A new integrated single-stage zero current switched(ZCS) quasi resonant convertedQRC) for the IX)wer f factor correction(PFCl converter is introduced in this paper. The power factor correction can be achieved by t the discontinuous conduction mod$\varepsilon$(DCM) operation of an input current. The proposed converter has the c characteristics of the good IX)wer factor, 10씨 line current harmonics, and tight output regulation. Furthern10re, t the ringing effect due to the output capacitance of the main switch can be eliminated by use of‘ active clamp c circuit. Therefore, the proIX)sed converter is expecttc'(] to be suitable for a compact power converter with a t tightly regulated output voltage requiring a switching frequency of more than several hundrtc'(]s kHz.

  • PDF

Study on Vacuum Pump Monitoring Using Adaptive Parameter Model (적응형 인자 모델을 이용한 개선된 진공펌프 상태진단에 관한 연구)

  • Lee, Kyu-Ho;Lee, Soo-Gab;Lim, Jong-Yeon;Cheung, Wan-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.3
    • /
    • pp.165-175
    • /
    • 2011
  • This paper introduces statistical features observed from measured batch data from the multiple operation state variables of dry vacuum pumps running in the semiconductor processes. The amplitude distribution characteristics of such state variables as inlet pressures, supply currents of the booster and dry pumps, and exhaust pressures are shown to be divided into two or three distinctive regions. This observation gives an idea of using an adaptive parametric model (APM) chosen to describe their statistical features. This modelling, in comparison to the traditional dynamic time wrapping algorithm, is shown to provide superior performance in computation time and memory resources required in the preprocessing stage of sampled batch data for the diagnosis of running dry vacuum pumps. APM model-based batch data are demonstrated to be very appropriate for monitoring and diagnosing the running conditions of dry vacuum pumps.

자화 유도 결합 플라즈마의 산화물 건식 식각 특성에 관한 연구

  • Jeong, Hui-Un;Kim, Hyeok;Lee, U-Hyeon;Kim, Ji-Won;Hwang, Gi-Ung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.230-230
    • /
    • 2013
  • 플라즈마를 활용한 미세 패턴의 건식 식각은 반도체 소자 공정에 있어서 가장 중요한 기술 중 하나이다. 한편, 매년 발행되는 ITRS Roadmap 에 따르면 DRAM 의 1/2 pitch 는 감소하는 동시에 Contact A/R (Aspect Ratio) 는 증가하고 있다. 이러한 추세 속에서 기존의 공정을 그대로 활용할 경우 식각물의 프로파일 왜곡 혹은 휨 현상이 발생하고 식각 속도가 저하되며 이러한 특성들이 결과적으로는 생산성의 저하로 이어질 수 있다. 이러한 현상을 최소화하기 위해서는 무엇보다 독립된 plasma parameter 들이 식각물의 프로파일 혹은 식각 속도 등에 어떠한 영향을 주는 지에 대한 학문적 이해가 필요하다. 본 논문에서는 최소 CD (Critical Dimenstion) 100nm, 최대 A/R 30 인 HARC (High Aspect Ration Contact hole) 의 식각 특성이 plasma parameter 에 따라 어떻게 변하는지 확인해 보고자 한다. 산화물의 식각은 대표적인 high density plasma source 중의 하나인 ICP에서 진행하였으며 기존에 알려진 plasma parameter 에 더하여 자장의 인가가 산화물의 식각 특성에 어떠한 영향을 주는지 살펴보고자 전자석을 ICP 에 추가로 설치하여 실험을 진행하였다. 결과적으로, plasma parameter 에 따른 혹은 자장의 세기 변화에 따른 산화물의 식각 실험을 플라즈마 진단 실험과 병행하여 진행함으로써 다양한 인자에 따른 산화물의 식각 메커니즘을 정확하게 이해하고자 하였다. 실험 내용을 요약하면 다음과 같다. 먼저, 전자석의 전류 인가 조건에 따라 축 방향 혹은 반경 방향으로의 자장의 분포가 달라질 수 있음을 확인하였고 플라즈마 진단 결과 축 방향 혹은 반경 방향으로의 자장이 증가하였을 때 고밀도의 플라즈마가 형성될 수 있음은 물론 반경 방향으로의 플라즈마 밀도의 균일도가 향상됨을 확인할 수 있었다. 또한 ICP 조건에서 바이어스 주파수, 압력, 바이어스 파워, 소스 파워, 가스 유량 등의 plasma parameter 가 산화물의 식각 특성에 미치는 영향 및 메커니즘을 규명하였고 이 과정을 통해 최적화된 프로파일을 바탕으로 축 방향 혹은 반경 방향으로 증가하는 자장을 인가하였을 때 (M-ICP 혹은 자화 유도 결합 플라즈마) ICP 대비 산화물의 식각 속도가 증가함은 물론 PR-to-oxide 의 선택비가 개선될 수 있음을 확인할 수 있었다. 자장의 인가에 따른 산화물의 정확한 식각 메커니즘은 향후의 실험 진행을 통해 이해하고 이를 통해 궁극적으로는 산화물의 식각 공정이 나아가야 할 올바른 방향을 제시하고자 한다.

  • PDF

Generalized Rapid Relaxation Inversion of Two-Dimensional Magnetotelluric Survey Data (GRRI를 이용한 2차원 MT 탐사자료의 역산)

  • Jeong, Yong-Hyun;Suh, Jung-Hee;Shin, Chang-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.1
    • /
    • pp.71-78
    • /
    • 1998
  • Inversion schemes of 2-D MT survey data generally take enormous computational time and computer memory. In addition, careful attention must be paid in handling MT data, especially in cases of TM mode, inversion results can be seriously distorted because of static effect caused by current channeling across inhomogeneous surface boundaries. There-fore inversion algorithm using the GRRI scheme for TM mode MT data was implemented. This scheme is based on a perturbation analysis with a locally 2-D analysis and local inversions were sequently performed over each divided section without additional forward modelings. The algorithm was applied to several synthetic data for the purpose of verification of its efficiency and applicability. With less computer resources than conventional schemes, it could handle static effect directly by including current channeling across inhomogeneous boundaries. Thus it is expected to be used for an useful tool such as a real-time inversion scheme in the field.

  • PDF

A Study on Coating Film Thickness Measurement in vehicle Using Eddy Current Coil Sensor (와전류 코일 센서를 통한 차량용 코팅막 측정에 관한 연구)

  • Park, Hwa-Beom;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.9
    • /
    • pp.1131-1138
    • /
    • 2019
  • The importance of coatings has been increasing for different purposes such as prevention of static electricity of auto parts or products, improvement of abrasion and corrosion resistance, and enhancement of esthetics. As a method for measuring the thickness of a coating film, a contact method with probe is commonly used. However, it is problematic that accuracy of the sensor is degraded due to sensor output distortion or load phenomenon, which is caused by a change in magnetic permeability of the core. In this study, we propose a method to reduce the measurement error of the coating film by applying the optimized circuit design and the thickness measurement algorithm to the problems caused by the nonlinear characteristics. The tests result which have been taken with different thickness coating samples show that the measurement accuracy is within ${\pm}2%$.