An Automatic Power Control Circuit suitable for High Speed Burst-mode optical transmitters (고속 버스트 모드 광 송신기에 적합한 자동 전력 제어 회로)

  • Ki, Hyeon-Cheol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.98-104
    • /
    • 2006
  • The conventional burst-mode APC(Automatic Power Control) circuit had an effective structure that was suitable for a low power consumption and a monolithic chip. However, as data rate was increased, it caused errors due to the effect of the zero density. In this paper, we invented a new structured peak-comparator which could compensate the unbalance of the injected currents using double gated MOS and MOS diode. And we proposed a new burst-mode APC adopting it. The new peak-comparator in the proposed APC was very robust to zero density variations maintaining the correct decision point of the current comparison at high data rate. It was also suitable for a low power consumption and a monolithic chip due to lack of large capacitors.

A Burst-mode Automatic Power Control Circuit Robust io Mark Density Variations (마크 밀도 변화에 강한 버스트 모드 자동 전력 제어 회로)

  • 기현철
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.4
    • /
    • pp.67-74
    • /
    • 2004
  • As data rate was increased, the conventional burst-mode automatic power control circuit caused errors due to the effort of the mark density variation. To solve this problem we invented a new structured peak-comparator which could eliminate the effect of the mark density variation even in high date rate, and revised the conventional one using it. We proposed a burst-mode automatic power control circuit robust to mark density variations. We found that the peak-comparator in the proposed automatic power control circuit was very robust to mark density variations because it affected very little by the mark density variation in high date rate and in the wide variation range of the reference current and the difference current.

AWM Driving Method with Hybrid Current Control for PM-OLED Panel (수동형 OLED를 위한 복합 전류 제어 기능을 갖는 AWM 구동방식)

  • Kim, Seok-Man;Lee, Je-Hoon;Hur, Yeo-Jin;Kim, Yong-Hwan;Cho, Kyoung-Rok
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.1
    • /
    • pp.116-123
    • /
    • 2007
  • This paper proposed a new amplitude width modulation for OLED data driver IC. The data driver controls brightness of OLED by adjusting amplitude and width of the data drive current pulse. There were two conventional methods; pulse amplitude modulation(PAM) and pulse width modulation(PWM). The PWM method suffered from lower light emitting time efficiency at low luminance signal. The PAM method suffered from large chip area using DACs for each column. The proposed method was aiming at accurately controlling of the current level by MSB data and light emitting efficiency by LSB data to improve the inefficiencies of the PAM and a PWM. The proposed AWM driver circuit implemented using $0.35-{\mu}m$ 3-poly 4-metal CMOS high voltage process. The simulation result shows the improvement in the accuracy of the gray level control even though the driver circuit is smaller than the PAM.

Verification on the Calculated Geoelectric Field on Power Grid during Geomagnetic Disturbances (지자기 교란으로 인한 전력망 유도전기장 예상값 검증)

  • Park, Sung Won;Yoo, Chung-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.1
    • /
    • pp.94-100
    • /
    • 2015
  • Coronal mass ejection (CME) released due to solar flare explosion cause geomagnetic disturbance. The induced current by massive geomagnetic disturbance can cause damage to the transformer. The calculated geoelectric field is a major parameter of the geomagnetically induced current (GIC). The method applying a Fourier transform has a high accuracy but it needs all data measured for 24 hours. And the other method applying a integral equation can calculate in real time but it requires to check an accuracy. To reduce the gap between the calculated results of two methods, it adjusts the integration section. As a result, the correlation between two calculated geoelectric fields is high, and the event time and direction of the calculated current is the same as that of the measured current, and it's accuracy rate is above 92 percent.

A Study on the Improvement of Fault Detection Capability for Fault Indicator using Fuzzy Clustering and Neural Network (퍼지클러스터링 기법과 신경회로망을 이용한 고장표시기의 고장검출 능력 개선에 관한 연구)

  • Hong, Dae-Seung;Yim, Hwa-Young
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.3
    • /
    • pp.374-379
    • /
    • 2007
  • This paper focuses on the improvement of fault detection algorithm in FRTU(feeder remote terminal unit) on the feeder of distribution power system. FRTU is applied to fault detection schemes for phase fault and ground fault. Especially, cold load pickup and inrush restraint functions distinguish the fault current from the normal load current. FRTU shows FI(Fault Indicator) when the fault current is over pickup value or inrush current. STFT(Short Time Fourier Transform) analysis provides the frequency and time Information. FCM(Fuzzy C-Mean clustering) algorithm extracts characteristics of harmonics. The neural network system as a fault detector was trained to distinguish the inruih current from the fault status by a gradient descent method. In this paper, fault detection is improved by using FCM and neural network. The result data were measured in actual 22.9kV distribution power system.

Realization of home appliance classification system using deep learning (딥러닝을 이용한 가전제품 분류 시스템 구현)

  • Son, Chang-Woo;Lee, Sang-Bae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.9
    • /
    • pp.1718-1724
    • /
    • 2017
  • Recently, Smart plugs for real time monitoring of household appliances based on IoT(Internet of Things) have been activated. Through this, consumers are able to save energy by monitoring real-time energy consumption at all times, and reduce power consumption through alarm function based on consumer setting. In this paper, we measure the alternating current from a wall power outlet for real-time monitoring. At this time, the current pattern for each household appliance was classified and it was experimented with deep learning to determine which product works. As a result, we used a cross validation method and a bootstrap verification method in order to the classification performance according to the type of appliances. Also, it is confirmed that the cost function and the learning success rate are the same as the train data and test data.

Characteristics of an 1.25 Gbps 850 nm Oxide VCSEL Transmitter Operating at Fixed Current over a Wide Temperature Range (넓은 온도 범위에서 고정 구동전류로 동작하는 1.25 Gbps 850 nm 산화형 VCSEL 송신기의 특성)

  • Kim, Tae-Ki;Kim, Tae-Yong;Kim, Sang-Bae;Kim, Sung-Han
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.12
    • /
    • pp.43-53
    • /
    • 2007
  • We have analyzed low current operation characteristics of a VCSEL transmitter operating at fixed Current over wide temperature range. Used 850 nm oxide VCSEL has low temperature dependence of the threshold current and $d^2I_{th}/dT^2$ is approximately $1.346\times10^{-4}mA/^{\circ}C^2$. We fixed on-current so that output power from the chip is 1 mW at $20^{\circ}C$ and investigated the turn-on, turn-off characteristics and eye-diagram of the 850 nm oxide VCSEL transmitter with varying ambient temperature and off-current. We measured rise time, fall time, extinction ratio and timing jitter by changing tile ambient temperature and off-current. With the fixed off-current of around $0.1\sim0.2mA$ lower than the lowest threshold current the transmitter successfully operated at 1.25 Gbps over a wide temperature range from $-20^{\circ}C$ to $80^{\circ}C$.

Study on the Railway Fault Locator Impedance Prediction Method using Field Synchronized Power Measured Data (실측 동기화 데이터를 활용한 교류전기철도의 고장점표정장치 임피던스 예측기법 연구)

  • Jeon, Yong-Joo;Kim, Jae-chul
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.5
    • /
    • pp.595-601
    • /
    • 2017
  • Due to the electrification of railways, fault at the traction line is increasing year by year. So importance of the fault locator is growing higher. Nevertheless at the field traction line, it is difficult to locate accurate fault point due to various conditions. In this paper railway feeding system current loop equation was simplified and generalized though measured data. And substation, train power data were measured under synchronized condition. Finally catenary impedance was predicted through generalized equation. Also simulation model was designed to figure out the effect of load current for train at same location. Train current was changed from min to max range and catenary impedance was compared at same location. Finally, power measurement was performed in the field at train and substation simultaneously and catenary system impedance was predicted and calculated. Through this method catenary impedance can be measured more easily and continuously compared to the past method.

A development of the gas pipeline risk prediction models (도시가스 배관 위험 예측 모델 개발)

  • Park, Giljoo;Kim, Young-Chan;Lee, ChangYeol;Jo, Young-do;Chung, Won Hee
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2017.11a
    • /
    • pp.360-361
    • /
    • 2017
  • 도시가스 배관의 안전을 위해 다양한 시스템이 가동되고 있지만 대부분 현장점검에 의존하는 한계점을 가지고 있다. 본 연구에서는 국내 도시가스 공급업체들 중 하나인 중부도시가스사의 실시간 배관운영 데이터를 분석해 배관의 위험을 예측한다. 배관의 압력, 출력전압, 출력전류, 방식전위, 전위값 데이터와 기타 도시가스 관련요인 데이터를 통합해 상관분석을 진행한다. 그리고 특정 공급권역의 실시간 배관 압력 데이터를 분석해 압력 수치를 예측한다. Random forest regression과 support vector regression(SVR) 알고리즘을 사용해 모델을 구성한 결과 배관 데이터의 시계열 정보를 추가한 데이터 셋과 random forest regression을 사용한 모델에서 가장 우수한 예측 성능을 보인다.

  • PDF

A study on the Trap Density of Silicon Oxide (실리콘 산화막의 트랩 밀도에 관한 연구)

  • 김동진;강창수
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.1
    • /
    • pp.13-18
    • /
    • 1999
  • The trap density by the stress bias in silicon oxides with different thicknesses has been investigated. The trap density by stress bias was shown to be composed of on time current and off time current. The on time trap density was composed of dc current. The off time trap density was caused by the tunneling charging and discharging of the trap in the interfaces. The on time trap density was used to estimate to the limitations on oxide thicknesses. The off time trap density was used to estimate the data retention in nonvolatile memory devices.

  • PDF