• Title/Summary/Keyword: 전류강성

Search Result 127, Processing Time 0.023 seconds

A Measurement and Diagnosis for Resistive Leakage Current of ZnO Arrester Element (ZnO 피뢰기 소자의 저항분 누설전류 측정 및 분석)

  • Lee, Bok-Hee;Kang, Sung-Man;Park, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2155-2157
    • /
    • 1999
  • This paper describes a new measurement method of resistive current and the technique of deterioration diagnosis for ZnO element. The consequence of current increasing (resistive current) with time is the eventual attainment of a state of thermal instability that may lead to arrester failure. So, it is very important to measure a leakage current of ZnO arrester installed at on-state. For the high-precision and more reliability, an iron core, which has a very high relative permeability, was used for increasing detection sensitivity, and we also used the personal computer for the data storage and program and analysis. And we have verified the reliability and performance of the sensing device through several laboratory tests.

  • PDF

A Technique of Deterioration Diagnosis for ZnO Element by Analyzing the 3rd order Harmonics- of Leakage Current (누설전류의 제3고조파 분석에 의한 ZnO소자의 열화진단기술)

  • Lee, Bok-Hee;Kang, Sung-Man
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1740-1742
    • /
    • 1998
  • This paper describes the technique of deterioration diagnosis for ZnO element. Due to the non-linear resistance of ZnO block, the total leakage current contains harmonics when arrester deteriorated. The most significant harmonics is the 3rd order component. So, it can be used as an indicator of the arrester condition. An iron core, which has a very high relative permeability, is used for increasing detection sensitivity and the 3th order harmonics of leakage current was detected by band-pass circuit. And we have verified the reliability and performance of the sensing device through several laboratory tests.

  • PDF

Characteristics of Rogowski coil at Low Cutrrent Region (저전류 영역에서 로고우스키 코일 특성)

  • Park, J.N.;Lee, K.W.;Lee, C.;Kim, K.S.;Park, Y.G.;Kang, S.H.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.47-50
    • /
    • 2001
  • Conventionally, air-cored Rogowski coil was designed for use as high alternating and transient current sensor without saturation caused by ferromagnetic material in its core. This paper investigated that Rogowski coil can be applied to low current measurement in 60Hz power line. Measured parameters R, L of coil were compared with theoretically calculated values. Output voltages crossed by Rogowski coil have shown some linearity according to input current(tens to thousands of amperes) passing through it. And also shielding effect for external noises was investigated for three cases.

  • PDF

The Properties of Electrical Conduction and Photoconduction in Polyphenylene Sulfide(PPS) by Uniaxial Elongation (일축연신에 따른 Polyphenylene sulfide(PPS)의 전기전도 및 광전도 특성)

  • 이운용;장동욱;강성화;임기조;류부형
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.223-226
    • /
    • 1998
  • In this paper, we have investigated how morphology and electrical properties in Polyphenylene sulfide(PPS) are changed by uniaxial elongation. XRD pattern shows that interplanar distance and crystallinities are decreased by increasing elongation ratio. Electrical conduction mechanism of PPS is explained as schottky emission from analysis of electrical current. The electrical current is decreased by increasing elongation ratio. The conductivity is changed remarkably above the glass transition temperature around $(82^{\circ}C)$. The band gap of PPS is evaluated as 3.9-4(eV) from the results of photoconductivity. Increarnent of elongation ratio gives us some information about deep trap formation from photocurrent.

  • PDF

Properties of Partial Discharge accompanying with Electrical Tree in LDPE (저밀도 폴리에틸렌에서 전기트리에 수반되는 부분방전의 특성)

  • 이광우;박영국;강성화;장동욱;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.234-238
    • /
    • 1999
  • The correlation between shape of electrical trees and partial discharge(PD) pulses in low density polyethylene(LDPE) were discussed. We observed growth feature of electrical tree by using optical microscope. On the basis of experimental results of measurements of trees occurring in the needle-plane arrangement with needle shape void and without needle shape void , statistical quantities are derived, which are relevant to PD pulse amplitude and phase. The PD quantities detected by partial discharge detector. we were analyzed q-n distribution pattern and $\psi$ -q-n distribution pattern. In this experiment, electrical trees in the needle-plane arrangement with needle shape void propagated branch type tree and in the needle-plane arrangement without needle shape void propagated bush type tree

  • PDF

Change of the Microstructure of ZnO Arrester block by Lightning Surge Current and Ageing test (뇌서지전류와 Ageing에 의한 산화아연형 피뢰기 소자의 미세구조변화)

  • Lee, Bok-Hee;Kang, Sung-Man
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1877-1879
    • /
    • 2000
  • This paper deals with the change of the micro-structure of ZnO associated with lightning surge current and ageing test. In this work, a surge current generator which can produce 8/20 [${\mu}s$], 6 [kA] impulse current is designed and fabricated to simulate the lightning impulse current. The residual voltage and leakage current flowing to ZnO blocks are observed. Also a compensation circuit was used in resistive current measurement. The micro-structures of ZnO arrester block were significantly changed by lightning surge current and accelerated temperature ageing test.

  • PDF

Analysis on Patent Trends for Human Body Communication (인체통신 분야의 특허 동향 분석)

  • Lee, B.N.;Park, W.;Kang, S.W.;Hwang, J.H.;Lee, S.K.
    • Electronics and Telecommunications Trends
    • /
    • v.25 no.3
    • /
    • pp.81-88
    • /
    • 2010
  • 저전력 및 고속통신을 특징으로 하는 인체통신은 사람의 신체를 매개물질로 하여 별도의 전력 소비 없이 인체에 통하는 전류를 이용하여 통신의 매체로 사용하는 기술을 말한다. 인체통신 기술은 향후 2~3년 후면 상용화 제품이 나올 것으로 예상되는 가운데, 휴대폰, PMP 등의 휴대단말기 등을 중심으로 인체통신 칩 시장이 형성되어 급속히 성장할 것으로 보이며, 아울러 접촉기반 인증서비스, 건강관리서비스 등 새로운 응용서비스 산업이 창출될 것으로 전망되고 있다. 이에 본 고에서는 인체통신 분야에 대한 시장 동향과 전세계 특허 동향을 분석해 보고자 한다.

Effects of injected number and amplitude of $8/20{\mu}s$ impulse current on the life of ZnO varistor ($8/20{\mu}s$ 임펄스전류의 크기와 인가횟수가 ZnO 바리스터의 수명에 미치는 영향)

  • Lee, B.H.;Lee, B.;Lee, S.B.;Kang, S.M.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.275-279
    • /
    • 2005
  • This paper presents leakage current characteristics as a function of injected number and magnitude of impulse current, when$8/20{\mu}s$ lightning impulse current is injected to ZnO varistor. The life of ZnO varistor against $8/20{\mu}s$ lightning impulse current was evaluated. The injected number of the test current to breakdown was inversely proportional to the amplitude of impulse current.

  • PDF

Nonlinear Sensorless Control of Indution Motor by using Feedback Linearization and Current Error (궤환 선형화 및 전류오차를 이용한 유도전동기 비선형 센서리스제어)

  • Seo Kang-Sung;Jeong Sam-Yong;Jung Byung-Ho;Lee Kang-Youn;Cho Geum-Bae;Baek Hyung-Lae
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.272-275
    • /
    • 2001
  • In this paper, author consider the nonlinear control by using feedback linearization for independent control and estimation algorithm such as speed, rotor flux and rotor resistance to achieve sensorless control of induction motor. The dynamic characteristics of the proposed nonlinear control algorithm is verified by simulation.

  • PDF

Design of Rogowski coil to improve of current measurement sensitivity (전류측정감도 개선을 위한 로고우스키 코일의 설계)

  • Park, J. N.;Lee, C.;Jang, Y. M.;Kang, S. H.;Lim, K. J.;Na, D. H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.609-612
    • /
    • 2001
  • Rogowski coil is made having no ferromagnetic material in a core. So the coil cannot be driven into saturation. This result in that Rogowski coils may be calibrated at relatively low currents, and used with confidence at very high currents. However the lowest level of current that can be measured is limited by the sensitivity of the voltage measuring instrument and system noise. Therefore, geometrical effects were investigated in order to measure high sensitivity of low level current and the significant source of error wa examined as well. n the results, the source of error was associated with coil designs, i.e. shape and uniformity of coil and a geometrical location of current source inside and outside of the Rogowski coil.

  • PDF