• Title/Summary/Keyword: 전력 차단

Search Result 508, Processing Time 0.028 seconds

Implementation of the automatic standby power blocking socket outlet having a blocking power threshold per electronic device by the smart machine (스마트 기기에 의해 전자기기별 차단전력문턱치 설정기능이 장착된 자동대기전력 차단콘센트 구현)

  • Oh, Chang-Sun;Park, Chan-Young;Kim, Dong-Hoi;Kim, Gi-Taek
    • Journal of Digital Contents Society
    • /
    • v.15 no.4
    • /
    • pp.481-489
    • /
    • 2014
  • In this paper, the automatic standby power blocking socket outlet to reduce standby power by blocking power threshold is implemented. Where, the standby power means a flowing power when a disused power electronic is plugged into the socket outlet. The proposed socket outlet can cut off the standby power by establishing a proper block power threshold electronic device according to each electronic device because it can monitor the amount of power through the smart machines such as the real-time PC or mobile phone and directly control the blocking power threshold. The software is implemented by using Visual Studio software, code vision and SN8 C studio, and the hardware is embodied in ATmega128, SN8F27E93S, USB to UART, and relay etc. Through the simulation, we find that the standby power of the proposed method is similar to that of the conventional method in case of the cellular phone but the standby power of the proposed method is much less than that of the conventional method in case of the computer, air conditioning, and set-top box. Therefore, it is proved that the proposed socket outlet has a superior performance in terms of the standby power.

Impact Assessment of Direct Load Control on Electric Power System (직접부하제어 시스템의 부하차단에 의한 전력계통 영향 평가)

  • Kwon, Seong-Chul;Lee, Hak-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.784-785
    • /
    • 2005
  • 직접부하제어 시스템은 시행기관과 고객사이에 약정을 맺고, 이를 전력계통의 수급비상시에 계통안정을 위하여 인터넷 등 통신채널을 통해 약정고객의 부하를 직접 차단하는 시스템이다. 우리나라의 전력계통은 지역적 특성상 발전군은 호남, 영남 및 서해안지역 등에 위치하고 있는 반면 대규모 부하소비는 수도권 지역에서 이루어짐으로써 이들간의 원활한 전력수급을 위하여는 상당한 규모의 북상조류가 이루어지고, 이 북상조류는 앞으로 더 커질 것으로 전망된다. 본 논문에서는 직접부하제어 약정부하의 부하차단을 통한 전력계통 안정도 및 전력조류량 변화를 모의함으로써 직접부하제어에 의한 부하차단이 전력계통에 미치는 영향을 다양한 부하차단 시나리오를 통해 평가하였다.

  • PDF

Design and Implement of Computer Power-off System for Sleep (절전을 위한 컴퓨터 전원 차단 시스템 설계 및 구현)

  • Kim, Myung-soon;Kim, Yong-su
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.11a
    • /
    • pp.1711-1713
    • /
    • 2010
  • 본 논문에서는 다수의 PC를 사용하는 네트워크 환경에서 사용자의 사용이 끝난 PC에 대해 전력을 관리함으로써, 불필요한 전력의 낭비를 절감하여 에너지의 효율을 높일 수 있는 다수의 PC 전력 제어 시스템을 제안한다. 현재의 PC의 전력을 관리하기 위한 방법으로는 Microsoft Windows나 Linux 등의 OS에서 기본적으로 절전 모드를 제공한다. 그러나 전력을 차단하는 것만큼 불필요한 에너지를 절감할 수 있는 방안은 없다. 따라서 본 논문에서는 이러한 불필요한 에너지들을 절감하기 위하여 네트워크를 기반으로 구축된 PC 환경에서, 전력의 유무를 검사하고 불필요한 전력을 차단할 수 있는 방안을 제시한다. 결과적으로 제안한 방법을 통하여 다수의 PC를 사용하는 환경에서 불필요한 전력을 감지하여, 이를 차단함으로써 에너지의 효율을 극대화 할 수 있었다.

Study on the overcurrent detection and blocking method of SiC MOSFET using the PCB pattern Rogowski coil (PCB패턴 Rogowski 코일을 이용한 SiC MOSFET의 과전류 검출 및 차단 기법에 관한 연구)

  • Yoon, Hanjong;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.92-94
    • /
    • 2018
  • 본 논문은 SiC MOSFET 디바이스를 사용하는 전력변환장치에서 Rogowski 코일을 이용하여 SiC MOSFET 디바이스에 흐르는 전류를 측정하여, 과전류를 검출하고 게이팅 신호를 차단하는 기법에 관하여 연구한다. SiC MOSFET는 소자의 특성으로 보편적으로 사용되는 과전류 검출 방법인 DeSAT 적용이 어렵기 때문에 Rogowski 코일을 사용하여 스위치 전류를 측정, 과전류를 검출한다. 본 논문에서는 PCB패턴 Rogowski 코일의 설계 방법뿐만 아니라 Rogowski 코일과 적분기의 대역폭에 대해서도 논의한다. 실험은 직류링크 커패시터에 SiC MOSFET 스위치 레그를 병렬로 연결하고, 직류링크 커패시터에 직류전압을 충전 후 스위치 레그를 약 6us정도 단락시켜 SiC MOSFET에 과전류를 발생시킨다. 이 때, 제안한 Rogowski 코일을 이용한 과전류 검출 및 차단 기법의 적용 전후를 비교하여 동작 및 성능(검출 및 차단 소요시간)을 확인한다. 마지막으로 실험 결과를 통해 본 논문에서 제안한 PCB패턴 Rogowski 코일을 이용하여 과전류 검출 및 차단 기법이 검증되었다.

  • PDF

Development of a Low-Price Device for Standby Power Cut-off (저가형 대기전력 차단장치 개발)

  • Lee, Sang-Yun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.3
    • /
    • pp.115-121
    • /
    • 2015
  • A device which could cut off the consumption of standby power by electric or electronic devices at homes and offices while waiting for a command to carry out the main functions from the inside or the outside was developed at a low price. Efforts to save standby power have been made on a global scale as well as by advanced countries. The consumption of standby power in South Korea is also increasing gradually due to increasing trend in the number of electronic and electric devices per household, becoming a major factor for waste of electric energy. The previous standby power cutoff devices themselves have high electric energy consumption and complicated structures, making the purpose less meaningful. Therefore, a low-priced standby power cutoff device is suggested in this study, which compensates such problems and cuts off the consumption of standby power completely. The circuit of the suggested standby power cutoff device was designed and implemented by applying it to an earth leakage breaker and an (electrical) outlet. Experimental results show its superiority.

Consideration On Short Circuit Tests For Evaluation Of Breaking Performance Of Current-Limiting Fuses (한류형 전력퓨즈의 차단성능평가 위한 단락시험에 관한 고찰)

  • Kim, Dae-Won;Suh, Yoon-Taek;Yoon, Hak-Dong;Jung, Hee-Jae;Kim, Maeng-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.543-545
    • /
    • 2003
  • 한류형 전력퓨즈는 계통의 단락사고로 고장 전류가 흐를 때 퓨즈내부에서 발생하는 저항에 의해 고장전류를 회로 고유의 단락전류보다 아주 적은 값으로 제한하고 최소 시간내에 차단하여 회로를 보호하므로 계통기기의 단락용량를 최소한으로 감소시킬 수 있다. 본 논문에서는 이러한 한류형 전력퓨즈의 단락전류 차단성능 평가를 위해 동작책무에 따른 차단성능을 규명하고자 단락발전기를 사용하여 단락전류차단시험을 실시하고 그 결과를 제시하였으며, 또한 차단과정에 따른 스트레스들이 단락시험 시 차단성능에 미치는 영향을 다루고 있다.

  • PDF

Development of a Cutoff Device for Saving Standby Power (대기전력 차단장치의 개발)

  • Kim, Jin-Geun;Hong, Seung-Hun;Kang, Moon-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1755_1756
    • /
    • 2009
  • 본 논문에서는 전기전자 기기가 외부전원에 연결된 상태에서 그 주 기능을 수행하지 않거나 내부 혹은 외부로 부터 주 기능 수행을 위한 명령을 기다리고 있는 상태에서 소모하는 대기전력(Standby Power)을 저감할 수 있는 장치를 개발하고자 하였다. 기존의 멀티탭 형대기전력 차단장치는 그 장치 자체의 소비전력이 커서 사용 의미를 퇴색시키는 문제점을 안고 있다. 본 논문에서는 기존 제품의 이러한 문제점을 보완시키고 대기전력을 획기적으로 감시킬 수 있는 멀티탭 형식의 외장형 대기전력 차단장치와 가전기기 내장형 차단장치의 회로를 설계 및 구현하고 비교 실험을 통하여 그 우수성을 확인하였다.

  • PDF

Development of Automatic Shutdown and Recovery Device for Standby Power using Doppler Sensor (도플러 센서를 적용한 대기전력 자동 차단복구 장치)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.17 no.10
    • /
    • pp.243-249
    • /
    • 2019
  • In this paper, we have developed a device to reduce the standby power consumption that is unnecessarily consumed in unused electrical appliances. The Doppler sensor is used to automatically power off and power off the outlet depending on whether or not a person is present near the outlet. The Doppler sensor uses a coaxial cable trap to design a transmitting antenna and emits a 10 GHz band RF signal and receives a reflected wave signal whose wavelength is reflected from the target object to the receiver to detect an object and recognize human approach. It automatically cuts off and restores standby power to prevent unnecessary power consumption, saving energy and developing a standby power automatic shutdown and recovery device that can prevent the risk of large fires caused by leakage current.

Arc extinguishment for DC circuit breaker by PPTC device (PPTC 소자를 사용한 직류차단기의 아크소호기술)

  • Kim, Yong-Jung;Na, Jeaho;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.52-53
    • /
    • 2017
  • 이상적인 차단기는 도통시 손실없이 부하에 전력을 공급하며 차단시 절연내력을 확보하여 전원과 부하사이를 완벽히 분리하여야 한다. 교류차단기의 경우 매 반 사이클 마다 전류가 스스로 제로가 되는 점이 발생하므로 사고전류의 차단이 비교적 용이하지만, 직류차단기의 경우 차단기 접점에서 높은 아크전압을 발생시켜서 사고전류를 감소시켜야 한다. 직류차단기가 충분한 아크전압을 확보하지 못하고 사고전류의 지속적 흐름을 허용하게 되면 고온의 아크전류로 인하여 대형화재로 이어질 수 있다. 전력전자소자를 사용한 반도체 차단기의 경우 기계적 차단기와 비교하여 차단시간이 빠르고 아크가 발생하지 않으며 소음이 적다는 장점이 있으나, 도통손실이 커서 대용량의 적용이 불가능하다는 문제가 있다. 본 논문에서는 기계적 차단기의 낮은 도통손실과 반도체 소자의 arc-less 차단특성의 장점을 살리는 차단기술로써 PPTC 소자를 사용한 직류차단기의 아크소호기술을 제시하고 실험을 통하여 성능을 증명한다.

  • PDF

Numerical Study on the Effects of Surface-inhibitors on the Spontaneous Ignition of Coal Stockpile (저탄장 자연발화에 미치는 표면차단제 영향에 관한 수치 해석적 연구)

  • Kim, Jae-Kwan;Park, Seok-Un;Shin, Dong-ik
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.20-29
    • /
    • 2019
  • In this paper, the effect of spontaneous combustion inhibitor on the surface of coal stockpile in coal yard was investigated by numerical analysis. First, the numerical analysis method of the present study was compared with the results of the previous study by analyzing the case where the spontaneous combustion inhibitor was not applied, and the effect of preventing spontaneous combustion by various areas and positions for spraying spontaneous combustion inhibitor was analyzed. As a result, the larger the application area of the spontaneous combustion inhibitor, the more the effect of preventing spontaneous combustion by blocking the oxygen inflow into the coal stockpile, and the greater the effect of the spontaneous combustion prevention when spraying spontaneous combustion inhibitor from the bottom of the coal stockpile. Spontaneous combustion inhibitor should be sprayed effectively, considering the economic aspects, such as manufacturing cost etc.