Journal of the Institute of Electronics Engineers of Korea SC
/
v.46
no.5
/
pp.44-51
/
2009
In this paper, an air conditioner peak power control system using electric power line communication has been developed. The air conditioner power control system using RS-485 communication method is hard to install on the existing buildings due to difficulty in cabling, and the system using wireless communication methods has a weak point of not being able to be used in close space, while the developed system has its own advantages of overcoming the above mentioned obstacles. In addition, the system is extended to support not only single-phase electricity system but also three-phase four-wire electricity system, and therefore can be installed anywhere in the domestic environment. The system also has enhanced the ease of deployment, operational stability and economical efficiency by compact circuit design. Considering the current state requiring the energy sayings, the system would greatly contribute to the widespread use of the air conditioner power control system. The superiority in the performance and stability of the system has been proved by the design verification of each component such as remote air conditioner controller, electric power line gateway and so on, and the field test of the whole system.
Journal of Advanced Marine Engineering and Technology
/
v.35
no.2
/
pp.288-294
/
2011
In this paper, the FPGA-based SoC board (Xilinx Virtex-4 ML401 EVM) is adopted to control electrical power inverter system. For marine application, its performance is shown on PC-based system for monitoring electrical characteristics of a power inverter using by the NMEA 2000 protocol. This power inverter system is achieved in Real-Time monitoring and control by dual micro-processor operation on embedded FPGA-based SoC board. One micro processor is for control (Control processor) electrical power inverter using by PWM signal. And the other microprocessor (Communication processor) is for communication with PC-based monitoring system. The two-processor is communicating each other using by dual-port ram (DPRAM). PC-based system user can control and monitor information of the electrical power inverter via NMEA 2000 based communication processor. Control and monitoring information includes the inverter status and configuration. SoC board converts this information to Parameter Group Numbers (PGNs) in the NMEA 2000 protocol. This system can be applied to marine power electronics for distributed power generation, transmission or regulation systems on the ship.
This paper presents the power control for the hybrid electric propulsion system. In this paper, the hybrid propulsion system consists cf the generator and battery as power supply system in ship. The hybrid control system is designed with energy saving algorithm for decreasing the power consumption of power supply system. This paper suggests the method to increase efficiency of hybrid electric propulsion system by developing battery charging system. The performance of power control system is analyzed with the experiment equipment for hybrid propulsion system, and the results showed a good property.
The Electrical Power System (EPS) shall supply required power to maintain spacecraft and payload during the mission. The EPS sizing are based on space environment, satellite
mission and lifetime, and allocated budgets. The type of the primary and secondary power is determined according to satellite design-level and allocated subsystem budgets. The design of EPS has closely related to system and others' subsystems design. To supply the sufficient power to the satellite, the implementation of the larger power source and energy storage is impossible actually. And there will be some problems of the attitude control of the satellite, the handling power capability of the electronic boxes, and launch vehicle selection caused by EPS oversizing. Also, the thermal control is not easy in the space by extra power. And the maintenance of the satellite within the specific orbit from orbit-drag is a big design burden of the thruster. So the various technologies have been developed to optimize the EPS sizing and to operate the power system efficiently.
Journal of the Korea Academia-Industrial cooperation Society
/
v.18
no.12
/
pp.26-31
/
2017
The conventional method of improving the transient stability in a power system is the use of reactive power compensation devices, such as the STATCOM and SVC. However, this traditional method cannot prevent the rapid voltage collapse brought about by the stalling of the motor due to a system fault. On the other hand, the ESS (Energy Storage System) provides fast-acting, flexible reactive and active power control. The fast-acting power compensation provided by an energy storage system plays a significant role in enhancing the transient stability after a major fault in the power system. In this paper, a method of enhancing the transient stability using an energy storage system is proposed for power systems including a dynamic load, such as a large motor. The effectiveness of the energy storage system compared to conventional devices in enhancing the transient stability of the power system is presented. The results of the simulations show that the simultaneous injection of active and reactive power can enhance the transient stability more effectively.
This paper presents a methodology that accelerates estimating the system-level power consumption for on-chip bus of SoC platforms. The proposed power modeling can estimate the power consumption according to the change of a target SoC system. The proposed model comprises two parts: the one is power estimation of bus logics reflecting the architecture of the bus such as the number of bus layers, the other is to estimate the power consumed by the bus lines during data transmission. We designed the target multimedia SoC system, MPEG encoder as an example and evaluated power consumption using this model. The simulation result shows that the accuracy of the proposed model is over 92%. Thus, the proposed power model can be used to design of a high-performance/low-power multimedia SoC.
Park, Sung-Wook;Kim, Jong-Shick;Lim, Su-Jin;HwangBo, Sea-Hee;Son, Joon-Ik;Lee, In-Yong;Wang, Bo-Hyeun
Journal of the Korean Institute of Intelligent Systems
/
v.20
no.5
/
pp.638-644
/
2010
This paper presents ideas of service scenarios for home residents using electric power monitoring system per appliance, the implementation of the monitoring system, and analysis of acquired electric power usage pattern. By acquiring and analyzing electric power usage pattern, home residents can get information of power usage pattern of every legacy (non-Demand Response-ready) appliance. Further they can get pieces of recommendation how to reduce energy consumption, intelligent standby power blocking service, and alarming service to abnormality of appliances. In order to check the feasibility of the ideas, a system that can acquire electric power pattern per appliance is implemented, and electric power pattern of some appliances are stored to a database and it was analyzed to show if auto-identification of a type of a device is possible, which is a basic required function for the scenarios presented.
본 논문에서는 고 전력밀도 및 저가형으로 구성 가능한 새로운 구조의 계통 연계형 태양광 인버터 시스템을 제안한다. 제안 시스템은 태양전지의 최대 전력점 추종기능과 배터리의 충 방전 기능을 단일 전력단으로 구성함으로써, 고 전력밀도 및 저가격형 시스템 구성이 가능하다. 또한, 제안 시스템은 배터리를 링크 캐패시터에 직렬 연결함으로써 링크 캐패시터의 전압 스트레스를 배터리 전압만큼 저감할 수 있으므로 가격저감 효과가 크다. 최종적으로 제안 시스템의 우수성과 신뢰성 검증을 위하여 1.5kW급 태양광 인버터 시스템의 시작품을 제작하였고, 이를 이용한 실험결과를 바탕으로 제안 시스템의 타당성을 검증한다.
Due to steady increase of electric power demand and decrease of load factor, the economic and reasonable operation of electric power system is necessary. Because of this reason, dispersed battery energy storage system(BESS) with fast response is receiving attractive attention. With these considerations, 20 kVA BESS is designed and tested to investigate the possibility of BESS application to power system. This paper describes the design specifications of simulator and test results. BESS is composed of batteries, conversion equipments, interconnecting equipments to power system, and control parts of the system. The inverter of BESS can carry out two functions as charger and discharger. Also, it can operate as a VAR compensator by four quadrant operation. Since this system is designed as a simulator of MW system, the conceptual design of MW system is possible by using the test result of test system The study of BESS is preliminary stage for the future MW class BESS.
Park, Shin-Yeol;Ha, Bok-Nam;Shin, Chang-Hoon;Kwon, Seong-Chul;Park, So-Young
Proceedings of the KIEE Conference
/
2006.11a
/
pp.261-263
/
2006
전력 계통은 발전설비, 송전설비, 변전설비, 배전설비 등으로 크게 나눌 수 있다. 전력계통을 구성하는 이런 설비들을 원격 감시하고 제어하는 시스템을 전력자동화 시스템이라고 한다. 이런 전력자동화 시스템은 국내 전체 에너지의 수요, 공급, 수송을 제어하는 에너지 관리시스템(EMS : Energy Management System), 송전 및 변전설비의 감시제어를 담당하는 송변전소 감시제어 시스템(SCADA : Supervisory Control And Data Acquisition), 배전계통의 실비관리 및 운영을 담당하는 배전자동화시스템(DAS : Distribution Automation System), 수용가의 계량기를 원격으로 읽어오는 원격검침시스템 (AMR : Automatic Meter Reading) 통으로 구성되어 있다. 국내에서 운용중인 배전자동화 시스템은 배전선로에 설치되어 있는 개폐기만을 원격 감시 및 제어 하는 보편적인 시스템이다. 한편, 2005년도 전력IT 국가 전략과제로 수행하고 있는 배전지능화 시스템 개발 과제에서는 변전소부터 배전계통과 수용가까지의 모든 전력 설비에 대한 원격감시제어가 가능한 시스템을 배전지능화 시스템이라고 정의하고 이의 개발을 추진하고 있다. 본 논문에서는 ABB, SIEMENS, GE와 같은 국외의 배전 자동화 시스템들을 소개하고, 배전지능화 시스템에서 목표로 하고 있는 GIS 기반 위에서 고 저압 배전설비를 관리하고, SCADA, DAS, GIS(Geographic Information System), AMR, TCS(Trouble Call System) 등 배전지능화 시스템의 중앙제어장치가 갖추어야 하는 주요 기능들에 대해 기술하고자 한다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.