• Title/Summary/Keyword: 전력 성능 평가

Search Result 965, Processing Time 0.032 seconds

Modeling and Implementation of Safety Test Device for Grounding System Based on IEC 60364 (IEC 60364의 접지방식에 기반한 안전성 평가 시험장치의 모델링 및 구현에 관한 연구)

  • Kim, Soon-Sik;Han, Byeong-Gill;Lee, Hu-Dong;Ferreira, Marito;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.599-609
    • /
    • 2021
  • A novel grounding system, which is presented in IEC 60364, has been adopted since 2021. A safety evaluation for the human body on the grounding system is required due to the various characteristics of the touch voltage and current passing when the human body experiences an electric shock. The Korea Electrical Safety Corporation (KESCO) and Korea Electric Association (KEA) have been conducting a safety technical education on the grounding system. On the other hand, it is difficult to instruct the electrical safety manager because of a lack of safety evaluations for the test equipment on the grounding system. Therefore, this paper modeled and implemented a test device for a safety evaluation depending on the grounding system of IEC 60364. Namely, this paper presents the modeling of the test device for a safety evaluation using PSCAD/EMTDC S/W, which is composed of an AC grid section, s test device section on the grounding system, and a sub-device section. This paper implemented a test device for safety evaluation, which consisted of an AC grid section, TT grounding system section, TN-S grounding system section, and monitoring section. From the simulation and test results with the safety characteristics of the human body in the TT and TN-S grounding system, when the fault impedances are 0[Ω], 10[Ω], and 100[Ω], the currents passing through the human body in the TT grounding system are 104[mA], 87.4[mA], and 35.5[mA], respectively. The corresponding currents in the TN-S grounding system are 54.9[mA], 4.1[mA], and 0.4[mA], respectively. Based on the results, the protection performance for an electric shock to the human body in the TN-S system is better than the TT system. This can be improved when the existing grounding system is changed from the TT system to the TN-S system.

Performance Improvement of Dielectric Barrier Plasma Reactor for Advanced Oxidation Process (고급산화공정용 유전체 장벽 플라즈마 반응기의 성능 개선)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.459-466
    • /
    • 2012
  • In order to improved treatment performance of dielectric barrier discharge (DBD) plasma, plasm + UV process and gas-liquid mixing method has been investigated. This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical). The basic DBD plasma reactor of this study consisted of a plasma reactor (consist of quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode), air and power supply system. Improvement of plasma reactor was done by the combined basic plasma reactor with the UV process, adapt of gas-liquid mixer. The effect of UV power of plasma + UV process (0~10 W), gas-liquid mixing existence and type of mixer, air flow rate (1~6 L/min), range of diffuser pore size (16~$160{\mu}m$), water circulation rate (2.8~9.4 L/min) and UV power of improved plasma + UV process (0~10 W) were evaluated. The experimental results showed that RNO degradation of optimum plasma + UV process was 7.36% higher than that of the basic plasma reactor. It was observed that the RNO decomposition of gas-liquid mixing method was higher than that of the plasma + UV process. Performance for RNO degradation with gas-liquid mixing method lie in: gas-liquid mixing type > pump type > basic reactor. RNO degradation of improved reactor which is adapted gas-liquid mixer of diffuser type showed increase of 17.42% removal efficiency. The optimum air flow rate, range of diffuser pore size and water circulation rate for the RNO degradation at improved reactor system were 4 L/min, 40~$100{\mu}m$ and 6.9 L/min, respectively. Synergistic effect of gas-liquid mixing plasma + UV process was found to be insignificant.

Performance Analysis of a Deep Vertical Closed-Loop Heat Exchanger through Thermal Response Test and Thermal Resistance Analysis (열응답 실험 및 열저항 해석을 통한 장심도 수직밀폐형 지중열교환기의 성능 분석)

  • Shim, Byoung Ohan;Park, Chan-Hee;Cho, Heuy-Nam;Lee, Byeong-Dae;Nam, Yujin
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.459-467
    • /
    • 2016
  • Due to the limited areal space for installation, borehole heat exchangers (BHEs) at depths deeper than 300 m are considered for geothermal heating and cooling in the urban area. The deep vertical closed-loop BHEs are unconventional due to the depth and the range of the typical installation depth is between 100 and 200 m in Korea. The BHE in the study consists of 50A (outer diameter 50 mm, SDR 11) PE U-tube pipe in a 150 mm diameter borehole with the depth of 300 m. In order to compensate the buoyancy caused by the low density of PE pipe ($0.94{\sim}0.96g/cm^3$) in the borehole filled with ground water, 10 weight band sets (4.6 kg/set) were attached to the bottom of U-tube. A thermal response test (TRT) and fundamental basic surveys on the thermophysical characteristics of the ground were conducted. Ground temperature measures around $15^{\circ}C$ from the surface to 100 m, and the geothermal gradient represents $1.9^{\circ}C/100m$ below 100 m. The TRT was conducted for 48 hours with 17.5 kW heat injection, 28.65 l/min at a circulation fluid flow rate indicates an average temperature difference $8.9^{\circ}C$ between inlet and outlet circulation fluid. The estimated thermophysical parameters are 3.0 W/mk of ground thermal conductivity and 0.104 mk/W of borehole thermal resistance. In the stepwise evaluation of TRT, the ground thermal conductivity was calculated at the standard deviation of 0.16 after the initial 13 hours. The sensitivity analysis on the borehole thermal resistance was also conducted with respect to the PE pipe diameter and the thermal conductivity of backfill material. The borehole thermal resistivity slightly decreased with the increase of the two parameters.

Classification of Transport Vehicle Noise Events in Magnetotelluric Time Series Data in an Urban area Using Random Forest Techniques (Random Forest 기법을 이용한 도심지 MT 시계열 자료의 차량 잡음 분류)

  • Kwon, Hyoung-Seok;Ryu, Kyeongho;Sim, Ickhyeon;Lee, Choon-Ki;Oh, Seokhoon
    • Geophysics and Geophysical Exploration
    • /
    • v.23 no.4
    • /
    • pp.230-242
    • /
    • 2020
  • We performed a magnetotelluric (MT) survey to delineate the geological structures below the depth of 20 km in the Gyeongju area where an earthquake with a magnitude of 5.8 occurred in September 2016. The measured MT data were severely distorted by electrical noise caused by subways, power lines, factories, houses, and farmlands, and by vehicle noise from passing trains and large trucks. Using machine-learning methods, we classified the MT time series data obtained near the railway and highway into two groups according to the inclusion of traffic noise. We applied three schemes, stochastic gradient descent, support vector machine, and random forest, to the time series data for the highspeed train noise. We formulated three datasets, Hx, Hy, and Hx & Hy, for the time series data of the large truck noise and applied the random forest method to each dataset. To evaluate the effect of removing the traffic noise, we compared the time series data, amplitude spectra, and apparent resistivity curves before and after removing the traffic noise from the time series data. We also examined the frequency range affected by traffic noise and whether artifact noise occurred during the traffic noise removal process as a result of the residual difference.

Random Access Phase Optimal Allocation Method Through Pattern Correction in WBAN (WBAN 환경에서 패턴 보정을 통한 임의접근구간 최적 할당 방법)

  • Lee, ChangHo;Kim, Kanghee;Kim, JiWon;Choi, SangBang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.92-105
    • /
    • 2015
  • WBAN (Wireless Body Area Network) is a network which is to consistently monitor body signals with implanted or attached sensor nodes. Especially, nodes that are used in medical services have to operate with low power consumption since they are hard to replace, and have to guarantee high data rate and low transmission delay for consistent signal monitor. In this paper, we propose an algorithm that aims to reduce transmission delay and power consumption, and guarantees stable throughput, by assuming the number of active nodes, and followed by dynamically adjusting the random access period and transmission possibilities in a superframe. The assumed number of active nodes may be incorrect since it only relies on the channel status of a previous superframe. Therefore, we assume the number of active nodes and define a pattern. And revise the number of the active nodes with the defined pattern. To evaluate the performance of the proposed algorithm, we have implemented a WBAN environment with the MATLAB. The simulation results show that the proposed algorithm provides better throughput, low power consumption, and low transmission delay when compared to the slotted ALOHA of the IEEE 802.15.6.

Evaluation of Heating Performance and Analysis of Heating Loads in Single Span Plastic Greenhouses with an Electrical or Hot-Air Heating (전기히터식 난방, 온풍난방시스템을 채용한 단동 플라스틱 하우스의 열부하 해석 및 난방성능 평가)

  • 허종철;임종환;서효덕;최동호
    • Journal of Bio-Environment Control
    • /
    • v.8 no.2
    • /
    • pp.136-146
    • /
    • 1999
  • A series of experiments were carried out in winter to investigate the indoor thermal environment in greenhouses with different kinds of heating systems, and characterize the energy consumption, heat transport and thermal energy efficiency of each system. By the Quantitative calculation of heat losses which transmit through the covers of greenhouse, the fundamental data of energy-saving of the particular heating system were obtained. And from the analysis of air temperature differences between indoor and outside, it was possible to select more effective energy-saving and comfortable heating system in greenhouses. The electric heater was more stable in thermal environment and cheaper in cost, since it could be used during the surplus time of electric power from 10:00 p.M. to 8:00 A.M. But the low air temperature in greenhouses besides these times resulted in a chilling problem of the crops. The heating system by hot air had the advantage to show nearly uniform temperature difference by the height above the ground. But the system had the disadvantage to require more energy consumption than the electric heating system.

  • PDF

A Practical Quality Model for Evaluation of Mobile Services Based on Mobile Internet Device (모바일 인터넷 장비에 기반한 모바일 서비스 평가를 위한 실용적인 품질모델)

  • Oh, Sang-Hun;La, Hyun-Jung;Kim, Soo-Dong
    • Journal of KIISE:Software and Applications
    • /
    • v.37 no.5
    • /
    • pp.341-353
    • /
    • 2010
  • Mobile Internet Device (MID) allows users to flexibly use various forms of wireless internet such as Wi-Fi, GSM, CDMA, and 3G. Using such Internet, MID users can utilize application services. MID usage is expected to grow due to the benefits of portability, Internet accessibility, and other convenience. However, it has resource constraints such as limited CPU power, small memory size, limited battery life, and small screen size. Consequently, MIDs are not capable to hold large-sized complex applications and to process a large amount of data in memory. An effective solution to remedy these limitations is to develop cloud services for the required application functionality, to deploy them on the server side, and to let MID users access the services through internet. A major concern on running cloud services for MIDs is the potential problems with low Quality of Service (QoS) due to the characteristics of MIDs. Even measuring the QoS of such services is more technically challenging than conventional quality measurements. In this paper, we first identify the characteristics of MIDs and cloud services for MIDs. Based on these observations, we derive a number of quality attributes and their metrics for measuring QoS of mobile services. A case study of applying the proposed quality model is presented to show its effectiveness and applicability.

커패시터에의 적용을 위해 PET 필름에 스퍼터 증착한 ZrO2 박막의 특성

  • Gwon, Neung;Fei, Chen;Ryu, Han;Park, Sang-Sik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.389.1-389.1
    • /
    • 2014
  • 최근의 환경 및 에너지에 대한 관심으로 수요가 증가하고 있는 하이브리드 및 전기 자동차나 태양광발전, 풍력발전용의 인버터기기에는 고에너지밀도 커패시터가 필수적이 되었다. 높은 에너지 밀도를 요구하는 전력전자, 펄스파워 등의 응용분야에 사용되는 고에너지밀도 커패시터는 PET (Polyethylene terephtalate)와 PP (Polypropylene)와 같은 폴리머 유전체를 사용하는 범용 필름 커패시터가 사용되었으나 사용 요구 조건의 한계에 도달하여, 새로운 유전체를 적용하는 커패시터가 절실히 필요한 상황이다. PET와 PP와 같은 유전체는 유전상수가 2~3의 낮은 값을 가지고 있어 고에너지밀도를 구현하기가 어렵다. 본 연구에서는 새롭게 요구되고 있는 고에너지 밀도 커패시터의의 성능을 만족시키기 위하여 $20{\sim}50{\mu}m$ 두께의 PET 필름상에 세라믹 유전체인 $ZrO_2$ 박막을 스퍼터(Sputter) 증착법에 의해 코팅하여 종래의 필름 커패시터와 세라믹 커패시터의 장점을 갖는 커패시터를 제조하기 위한 박막 유전재료의 개발을 목표로 하였다. 수백 nm~수 ${\mu}m$ 두께의 $ZrO_2$ 박막을 스퍼터링 공정조건에 따라 증착한 후 박막의 결정성, 기판과의 부착성, 증착속도, 유전상수, 절연파괴강도, 온도안정성 등을 XRD, SEM, AFM, EDS, XPS, Impedance analyzer 등에 의해 평가하였다. $ZrO_2$ 유전체막은 상온에서 증착하였음에도 정방정(tetragonal)구조의 결정질로 성장하였고 증착압력이 증가함에 따라 주피크의 세기가 감소하였다. 증착 중 산소가스를 주입하였을 경우에도 결정질막으로 성장하였다. 증착막들은 산소가스의 양이 증가함에 따라 짙은 흰색으로 변하였으며 PET 기판과의 접착력도 약해졌다. 또한 거칠기는 Ar가스만으로 증착한 경우보다 증가하였으며 24~66 nm의 평균 거칠기값을 보였다. PET위에 Ar가스만으로 증착한 $ZrO_2$의 비유전율은 1kHz에서 116~87의 비유전율을 보여 PET에 비해 매우 우수한 특성을 보였다. $ZrO_2$ 막들은 300kV/cm의 전계에서 대략 10-8A 이하의 누설전류를 보였다. 증착가스비를 달리하여 제조된 시편에서도 유사한 누설전류값을 나타내었다. 300 kV/cm 전후의 전계까지 측정한 $ZrO_2$ 막의 P-E (polarization-electric field) 특성을 확인하였는데, 5 mTorr의 압력에서 증착한 막은 253 kV/cm에서 $5.5{\mu}C/cm^2$의 분극값을 보였다. P-E커브의 기울기와 분극량에 따라 에너지밀도가 달라지므로 공정조건에 따라 에너지밀도가 변화됨을 예측할 수 있었다. PET위에 스퍼터 증착한 $ZrO_2$ 유전체막은 5mTorr의 Ar가스분위기에서 제조할 때 가장 안정적인 구조를 보였으며, 고에너지밀도 커패시터에의 적용가능성을 보였다.

  • PDF

Positioning Scheme Based on Iterative Path-Loss Exponent Estimation in WSNs (무선 센서 네트워크에서 반복적인 Path-Loss Exponent 추정을 통한 위치추정 기법)

  • Choi, Jun-Ho;Choi, Jae-Kark;Yoo, Sang-Jo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37B no.10
    • /
    • pp.889-900
    • /
    • 2012
  • In wireless sensor networks, the positioning scheme using received signal strength (RSS) has been widely considered. Appropriate estimation of path-loss exponent (PLE) between a sensor node and an anchor node plays a key role in reducing position error in this RSS-based positioning scheme. In the conventional researches, a sensor node directly uses the PLEs measured by its nearest anchor node to calculate its position. However, the actual PLE between a sensor node and the anchor node can be different from the PLE measured by its nearest anchor node. Thus, if a sensor node directly uses the PLEs measured by its nearest anchor node, the estimated position is different from the actual position of the sensor node with a high probability. In this paper, we describe the method how a sensor node estimates PLEs from the anchor nodes of interest by itself and calculates its position based on these self-estimated PLEs. Especially, our proposal suggests the mechanism to iteratively calculate the PLEs depending on the estimated distances between a sensor node and anchor nodes. Based on the recalculated PLEs, the sensor node reproduces its position. Through simulations, we show that our proposed positioning scheme outperforms the traditional scheme in terms of position error.

Index Management Method using Page Mapping Log in B+-Tree based on NAND Flash Memory (NAND 플래시 메모리 기반 B+ 트리에서 페이지 매핑 로그를 이용한 색인 관리 기법)

  • Kim, Seon Hwan;Kwak, Jong Wook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.5
    • /
    • pp.1-12
    • /
    • 2015
  • NAND flash memory has being used for storage systems widely, because it has good features which are low-price, low-power and fast access speed. However, NAND flash memory has an in-place update problem, and therefore it needs FTL(flash translation layer) to run for applications based on hard disk storage. The FTL includes complex functions, such as address mapping, garbage collection, wear leveling and so on. Futhermore, implementation of the FTL on low-power embedded systems is difficult due to its memory requirements and operation overhead. Accordingly, many index data structures for NAND flash memory have being studied for the embedded systems. Overall performances of the index data structures are enhanced by a decreasing of page write counts, whereas it has increased page read counts, as a side effect. Therefore, we propose an index management method using a page mapping log table in $B^+$-Tree based on NAND flash memory to decrease page write counts and not to increase page read counts. The page mapping log table registers page address information of changed index node and then it is exploited when retrieving records. In our experiment, the proposed method reduces the page read counts about 61% at maximum and the page write counts about 31% at maximum, compared to the related studies of index data structures.