• Title/Summary/Keyword: 전력품질개선

Search Result 227, Processing Time 0.028 seconds

Modeling and Analysis of Modified Active Frequency Drift Method (개선된 AFD기법의 모델링 및 분석)

  • An, Jin-Ung;Yu, Gwon-Jong;Choy, Ich;Choi, Ju-Yeop;Lee, Ki-Ok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.145-151
    • /
    • 2011
  • In this paper, among the active islanding detection techniques, the modified active frequency drift method was analyzed, which is relatively easy to apply to the single-phase grid-connected PV PCS. The existing designs for turbulences in these applications were empirically conducted, and do not have sufficient reliability and performance. Therefore, three application forms of the modified active frequency drift technique were modeled, based on which the proper magnitude of turbulence, which is the frequency acceleration component, was calculated. Using the results, the magnitude of and injection method for turbulence for ensuring the islanding detection performance and improving the output power quality were proposed, and they were verified via simulations and experiment to prove that the reliable islanding detection technique can be developed merely by measuring the basic output power quality, without the need for expensive islanding simulation equipment.

Research Analysis for Trouble Case of Power Capacitor (전력용 커패시터 사고 사례 조사 분석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong;Kim, Il-Joong;Cho, Seung-Su
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.217-220
    • /
    • 2008
  • 전력용 커패시터는 부하의 역률개선과 선로전류의 감소에 의한 변압기 용량의 여유와 선로의 리액턴스나 저항에 의한 전압강하가 감소로 전압이 안정되어 부하설비의 생산 능률과 제품의 품질 향상에 도움이 되기 때문에 송배전 회로망 또는 부하설비에 설치 운영되고 있다. 한편 부하의 변동에 따른 역률조정을 위한 스위칭 동작과 비선형 부하 등의 사용은 고조파 전류의 유입으로 전압 및 전류 스트레스를 증가시킬 수 있다. 커패시터는 낙뢰와 같이 일시적인 과전압에 의해 커패시터를 고장 나는 것도 있지만, 오랫동안의 스트레스로 고장이 나는 경우가 많아 커패시터가 고장 나는 정확한 원인분석을 체계적으로 한 보고서가 많지 않다. 본 연구에서는 국내외 일부 발표된 자료를 가지고서 커패시터가 전기품질 변동에 의해 고장이 일어날 수 있는 원인 등을 찾아 분석하였다.

  • PDF

Dynamic Modeling and Controller Design of PWM Buck-Boost AC-AC Converter (PWM Buck-Boost AC-AC 컨버터의 동적 모델링 및 제어기 설계)

  • 최남섭;배영철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.749-753
    • /
    • 2003
  • This paper presents an output voltage regulation system using PWM Buck-Boost AC-AC converter for power qualify improvement of custom power. This paper proposes dynamic modeling of the system for control object and in addition, a controller design example. Therefore, system state equation is derived whereby the transfer function could be obtained. The paper shows a regulation controller for tracking the output voltage to the reference under specific operating point. Finally, this paper shows validity and practical applicability of the proposed modelling and system design by experimental results.

  • PDF

Design of Modified Slip-Mode Frequency Shift Islanding Detection Method for Power Quality Improvement (Slip-Mode Frequency Shift 단독운전 검출 기법의 정상상태 전력 품질 개선)

  • Kim, Dong-Uk;Kim, Sungmin
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.539-547
    • /
    • 2018
  • Grid-connected inverter is required to cut off the power supplied to the grid at the islanding condition, immediately. For this reason, an islanding detection is an indispensable function for grid-connected distributed generation system. Slip-Mode frequency Shift (SMS) islanding detection method is very popular method to determine the grid state. SMS method supplies the reactive power to the load according to the grid frequency. In the islanding condition of grid, this injected reactive power pulls out the grid frequency from the allowable range, then the inverter system can detect the islanding condition of the grid. The SMS method can detect the islanding state well and does not generate any harmonics of the grid current. However, the reactive power would be generated and the power quality is reduced even though the grid is not islanding condition, but normal condition. In this paper, a modified SMS method is proposed to remove the reactive power in the normal condition. The performance of the proposed method is evaluated by 600W single phase inverter experimental results.

Switching Characteristics Analysis of a 3-phase Voltage Disturbance Generator Applicable to Linear and Nonlinear Loads (선형 및 비선형 부하에 적용 가능한 3상 전압변동 발생기의 스위칭 특성해석)

  • Nho, Eui-Cheol;Park, Sung-Dae;Kim, In-Dong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.163-170
    • /
    • 2008
  • Switching characteristics in both linear and nonlinear loads are analysed for a 3-phase voltage disturbance generator applicable to the performance test of custom power devices. Since the line current of the linear load is continuous the natural commutation of the SCR thyristors comprising the generator is carried out with ease. However, in case of nonlinear load the natural commutation scheme is different from that of the linear load due to the discontinuous load current. Through the analysis it is found that a specific switching condition can provide the voltage sag, swell, outage, and voltage unbalance generation in nonlinear load too. The operation of the voltage disturbance generation is described and the usefulness of the generator is verified through simulation and experimental results. It is expected that the generator can be used in the performance test of the custom power devices with low implementation cost and easy control.

Effect of RF Bias on Electron Energy Distributions and Plasma Parameters in Inductively Coupled Plasma (유도 결합 플라즈마에서 플라즈마 변수와 전자 에너지 분포에 대한 극판 전력 인가의 영향)

  • Lee, Hyo-Chang;Chung, Chin-Wook
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.3
    • /
    • pp.121-129
    • /
    • 2012
  • RF biased inductively coupled plasma (ICP) is widely used in semiconductor and display etch processes which are based on vacuum science. Up to now, researches on how rf-bias power affects have been focused on the controls of dc self-bias voltages. But, effect of RF bias on plasma parameters which give a crucial role in the processing result and device performance has been little studied. In this work, we studied the correlation between the RF bias and plasma parameters and the recent published results were included in this paper. Plasma density was changed with the RF bias power and this variation can be explained by simple global model. As the RF bias was applied to the ICP, increase in the electron temperature from the electron energy distribution was measured indicating electron heating. Plasma density uniformity was enhanced with the RF bias power. This study can be helpful for the control of the optimum discharge condition, as well as the basic understanding for correlation between the RF bias and plasma parameters.

도심건물 밀집지역 배전 Station 건설(상)

  • 강희태;설규환
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.315
    • /
    • pp.30-37
    • /
    • 2003
  • 오늘날 국민생활에 전기의 의존도는 날로 높아지고 또한 매우 다양하고 고품질의 전력공급을 요구하고 있으며 정보산업사회로의 진입에 따라 고객의 기대수준에 전력공급설비의 발달이 미처 따라주지 못하고 있어 고객에게 감동을 주는 서비스의 실현이 더욱 어려워지고 있는 것이 현실이다. 특히 서울 명동지역은 구건물의 밀집지역으로 상권이 형성되어 있고 외국인 관광객들의 명소로 점차 자리잡아 가고 있는데 반해 전력공급설비는 국내 초기 지중화지역으로 기기설치 공간이 부족하여 노후된 건물 옥상에 다수의 변압기, 케이블이 설치 운영되고 있어 설비관리의 어려움뿐만 아니라 신규전력공급에 부응치 못하는 한계에 도달, 특히 밀집상가의 화재발생 우려 등 많은 문제점으로 안정적 전력공급을 위한 대책이 절실히 요구되는 상황이 되었다. 따라서 이 난해한 문제의 해결과 설비개선을 위해 보다 근원적인 대책을 모색하고자 ‘99년 초 한국전력공사 서울지역본부에 설비혁신 Task-Force를 운영, 명동지역에 가칭 배전 Station 건설을 포함한 종합정비사업을 추진키로 하였다. $\ulcorner$배전 Station$\lrcorner$ 이란 건물 내에 개폐기, 변압기 등 전력기기를 모두 수용하여 전력을 공급하는 소형 배전형 변전소 형태로 국내는 물론 세계적으로도 찾아보기 힘든 경우라 할 것이다. 건울과 설비가 복잡하기로 유명한 유서 깊은 명동지역의 특수한 주변 환경과 조화된 안정적 전력공급의 획기적인 대안으로 실현되고 있는 영동 배전 Station은 현재 3개소를 추진하여 준공단계에 있으며 도심건물 밀집지역의 전력공급에 만전을 다할 것으로 기대하고 있다.

  • PDF

Improvement of Current Distortion of PWM Converter under Unbalanced Grid Voltage (계통 불평형 상태에서의 PWM 컨버터 전류 왜곡 개선)

  • Han, Sang Hyup;Kim, Heung-Geun;Cha, Honnyong;Chun, Tae-Won;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.504-505
    • /
    • 2013
  • 본 논문은 전류의 왜곡을 발생시키는 고조파 성분을 제거하고, 계통 전압 불평형시 PWM 컨버터 출력 전류의 품질을 개선하는 기법을 제시한다. 출력 전류에 고조파가 포함된 경우, 이러한 왜곡을 보상하기 위해서 각각의 고조파에 대한 공진제어기를 주 전류제어기와 병렬로 추가하면 디지털 제어 시스템에서 연산시간이 증가한다. 반복제어기를 병렬로 추가하면 DSP의 연산시간이 줄어들고, 높은 차수의 고조파 제거가 용이해져 총고조파 왜율이 줄어드는 이점이 있다.

  • PDF

Case Study of ESS for Frequency Regulation in Substation (주파수 조정용 에너지 저장 시스템의 변전소 적용 사례)

  • Kim, Tae-Hyeong;In, Dong-Seok;Lee, Jong-Hak;Oh, Seung-Jin;Park, Young-Min;Kim, Dong Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.421-422
    • /
    • 2016
  • 에너지 저장 시스템(ESS, Energy Storage System)은 주파수 조정을 통한 계통 전력품질 개선, 풍력(WT)발전, 태양광(PV)발전등과 같은 신재생 에너지의 출력안정화, 에너지 저장을 통한 에너지효율화 등의 분야에 적용되고 있다. 특히 주파수 조정(F/R, Frequency Regulation)을 위한 에너지 저장 시스템은 한전의 많은 투자를 통해 활발하게 이루어 지고 있으며, 전국 변전소에 설치되고 있다. 주파수 조정을 위한 에너지 저장 시스템은 주파수 상승 시 계통의 전력을 배터리에 충전하고, 주파수 하락 시에는 배터리에 저장된 에너지를 계통에 공급하여 주파수를 안정화 시키는 역할을 한다. 본 논문에서는 주파수 조정용 에너지 저장 시스템의 변전소 적용 사례에 대해 설명한다.

  • PDF

A Review of Summer Peak Pourer System in 2008 (2008년 하절기 전력계통 운영실적 분석)

  • Lee, Chang-Gun;Jo, Jong-Man
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.25-27
    • /
    • 2008
  • 전력거래소는 매년 여름철 최대부하 계통을 포함해저 설비의 신증설 등 계통 변경사항이 발생하면 "전력계통 신뢰도 및 전기품질 유지기준"(지경부 고시, 2005. 11월 개정)을 만족하도록 운영방안을 수립하고 있다. 여기에는 전력계통 망의 구성방안, 융통한계량, 과도 및 전압안정도를 유지하기 위한 고장파급 방지장치의 운영방안 결정, 상정고장이 발생 했을 때의 조치방안 등을 포함한다. 이와 같은 계통운영방안을 보다 신뢰성 있게 수립하기 위해서는 우리나라 계통의 특성을 정확히 파악하는 일이 무엇보다 중요하다. 본 고는 올 하절기 최대부하 기간의 계통운영 실적자료를 이용하여 우리나라 계통의 특성을 분석하고, 실적계통의 최적화된 결과와 비교하여 운영개선방안을 도출하고자 한다. 검토결과는 향후 계통운영방안 수립을 위한 기초자료로 활용될 예정이다.

  • PDF