• Title/Summary/Keyword: 전력용 콘덴서

Search Result 59, Processing Time 0.042 seconds

Standard Comparison Investigation of Power Condenser (전력용 콘덴서의 규격 비교 연구)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Wong;Lee, Dong-Ju;Kim, Il-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.78-81
    • /
    • 2008
  • Capacitors are known as condensers. They play an important in the industrial site because of benefits such as var support, improved voltage control and power factor, increased system capacity, and reduction of system power losses. But capacitors can be seriously affected by bad power quality such as transient and impulsive overvoltage, overload, harmonics. Capacitor standards and application guides are revised or supplemented by speedy technology advancements in the manufacturing of capacitors and in the power electronics. This paper presents various illustrations and comparison for several standards of power system capacitors.

  • PDF

Balancing System for Electric Double Layer Capacitor (전기이중층 캐패시터용 밸런싱 시스템)

  • Nam, Jong-ha;Jo, H.M;Park, J.G;Park, S.U;Kang, D.H;Kim, Y.S;Hwang, H.S
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.59-60
    • /
    • 2013
  • 슈퍼캐패시터(Super Capacitor) 또는 울트라 캐패시터(Ultra Capacitor) 등으로 불리우는 전기 이중층 캐패시터(EDLC, Electric Double Layer Capacitor)는 기존 콘덴서보다 월등한 용량 특성을 가지며, 전극과 전해질의 화학반응을 이용하던 이차전지들과 달리 주로 계면반응을 사용한 축전원리를 이용하여 높은 출력밀도와 충방전 효율, 무제한에 가까운 사이클 특성을 가지고 있다. 또한 전류변화에 안정적이어서 기존의 이차전지와는 달리 보호회로를 생략할 수 있기 때문에 단순한 회로 구성이 가능하고 전극활물질로서 탄소재를 사용하여 환경 친화적인 특성을 가진 차세대 에너지저장장치라고 할 수 있다. 특히 50만 사이클이라는 우수한 수명특성으로 인해 기존의 이차전지가 사용되기 어려운 다양한 분야에 적용이 늘어가고 있는 추세에 있다.

  • PDF

Optimal Control of UPFC and Switched Shunt Capacitor by Using Genetic Algorithm (GA를 이용한 UPFC와 전력용 콘덴서의 최적 제어)

  • Kim, Hak-Man;Kim, Jong-Yul;Oh, Tae-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.9-11
    • /
    • 2003
  • In power system planing and operation, voltage and reactive power control are very important. The voltage deviation and system losses can be reduced through control of reactive power sources. In general, there are several different reactive power sources, we used UPFC and switched shunt capacitor to improve the voltage profile and to reduce system losses in this study. Since there are many switched shunt capacitors in power system, so it is necessary to coordinate these switched shunt capacitors. In this study, Genetic Algorithm(GA) is used to find optimal coordination of UPFC and switched shunt capacitors in a local area of power system. In case study, the effectiveness of the proposed method is demonstrated in KEPCO's power system. The simulation is performed by PSS/E.

  • PDF

Harmonic reduction plan from multiple UPS installation place (다수의 UPS 설치장소에서의 고조파 저감방안)

  • Choi, Hyeong-Cheol;Chang, Jeong-Ho;Han, Chang-Dong;Lee, In-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1088-1089
    • /
    • 2007
  • 산업현장에서 발생하는 고조파는 전력용콘덴서의 과열 또는 고장, 케이블의 절연열화, 보호계전기 오동작 또는 부동작, 자동화 및 제어설비 오동작 등 전기설비에 대해 막대한 피해를 주고 있다. 고조파의 발생원인은 전력전자 소자를 이용한 변환장치(정류기, 인버터)의 전원 변환시($DC{\rightarrow}AC$) 주로 발생되고 있으며, 그 발생원은 기기별, 계통구 성별 등 그 특성에 따라 다양하게 발생되고 있다. 이 논문에서는 다수의 UPS 설치장소에서의 고조파 발생의 특성 및 그 영향에 대해 분석하고 저감방안의 실증을 통해 고조파에 대한 설비보호 방안을 제시하고자 한다.

  • PDF

The Analysis of Accidents on an auxiliary power system in case of a blackout (자가용 전기설비의 비상용 예비발전설비 사고사례 분석)

  • Choi, Myeong-Il;Bae, Suk-Myeong;Yoo, Jae-Geun;Jeon, Jeong-Chay;Lim, Yong-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2170_2171
    • /
    • 2009
  • 비상용 예비전원설비는 정전이 되었을 경우 건축물의 기능 유지나 영업을 위해 최소한의 방재와 비상전력을 확보하기 위한 설비이다. 그러나 최근 부하운전시험으로 발전기 가동시 부하단의 콘덴서, 고조파, UPS와 같은 SCR 부하의 영향으로 발전기 전원측에서 이상전압이 발생하여 과전압이 부하에 공급되어 기기가 소손되는 사고가 빈번히 발생하고 있다. 본 논문에서는 국내의 국내 예비발전설비의 운용 현황과 발전기 보호시설 유무에 대한 실태조사를 하였고, 최근 10년간 발전기 관련 사고 사례를 조사하여 사고의 원인을 분석하였다. 또한 발전기의 부하운전시 발전전원측의 전원품질을 측정하여 향후 사고해석 SW를 이용하여 시뮬레이션 및 사고재연 실증시험을 통해 보다 정확한 사고원인 및 사고발생 대책을 제시하는데 자료로 이용 될 것이다.

  • PDF

Control of Power Quality Using a High Voltage STATCOM for the Integration of Large Scale Wind Power Plant (고전압 무효전력 보상기를 사용한 대규모 풍력발전 설비의 전력 품질 보상)

  • Kim, Jihong;Song, Seungho;Jeong, Seunggi
    • New & Renewable Energy
    • /
    • v.8 no.4
    • /
    • pp.13-20
    • /
    • 2012
  • This paper describes a transformerless static synchronous campensator (STATCOM) system based on cascade H-bridge multilevel inverter with star configuration. It is designed not only for the dynamic and continuous compensation of the reactive power but also for the improvement of power quality of existing wind power plant. Especially, when the induction generator of wind turbine is directly connected to the grid, reactive power are occurred by exiting current. so a reactive power compensation system based on the cascade H-bridge multilevel STATCOM is proposed because the output power quality and controllability of reactive power are required by grid code in many different countries. Using various The proposed reactive power control strategy using a STATCOM is compared with the conventional scheme using fixed-size of capacitor bank through various simulation results.

Study of Deterioration Improvement of Power Fuse (전력퓨즈의 열화현상 개선에 관한 연구)

  • Song, Jae-Ki;Kim, Hwan-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3827-3831
    • /
    • 2014
  • This paper aims to solve the problem deterioration of power fuses. The deterioration of a power fuse is a cause of failure misoperation by a normal current flowing reduplicatively to fuse the element. An extension survey of a load feature rerating power fuse examined the power fuse deterioration removal, the cause of the deterioration of the power fuse, the front-after, and the thermal variation of the inside transformer room electric power equipment. The transformer showed an average improvement of $6[^{\circ}C]$. The temperature of the electrical line showed $7{\sim}8[^{\circ}C]$ improvement. The static condenser and direct reactor was $2{\sim}3[^{\circ}C]$ high-state maintenance the temperature and equipment syntonization relationship. In the subject of study $0.5{\sim}1.0[^{\circ}C]$ stabilizing three phase power fuse temperature differential was. Suggestion in the transformer room environment power equipment between the cause temperature happen elimination to deterioration of power fuse and temperature rise control.

A parallel-series type AC-DC converter with a fast dynamic response (빠른 동적 응답특성의 병렬-직렬 구조형 AD-DC 컨버터)

  • Chae, S.Y.;Hyun, B.C.;Kim, W.S.;Shin, J.W.;Cho, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.49-51
    • /
    • 2008
  • 본 논문은 중용량급 전원회로의 구성을 간략화 할 수 있는 절연형 AC-DC 컨버터의 구조와 그 제어 방법을 제안한다. 제안하는 회로의 구조는 병렬 전력 처리를 기반으로 한다. 병렬 모듈의 기능을 각각 AC 입력 전류의 위상을 제어하는 역률개선(PFC) 기능과, 콘덴서에 저장된 에너지를 이용하여 DC 전압을 생성하는 DC-DC 컨버터의 기능으로 분리한다. 병렬 모듈의 최종 출력단을 서로 직렬 연결하여, PFC 모듈이 생성한 전압과 DC-DC 컨버터 모듈이 생성한 전압을 서로 더해서 출력하는 구조이다. 이러한 구조를 통해서 기존의 병렬형 AC-DC 컨버터에 대비하여 반도체 소자의 내압을 감소시킬 수 있고, 최종 DC 전압의 동작응답특성 향상이 가능하다. 회로의 동작모드 분석이 실시되었고, 제어기 구현 방법이 제시되었다. 제안된 구조는 PDP 전원회로에의 응용을 위해서 400W(출력전압-200V, 출력전류-2A)급 실험용 회로를 구현하여 동작검증을 실시하였다.

  • PDF

The study on Harmonic Current Generated on Power Supply Station in(for) Conventional line and The Review on Effect of facility reducing Harmonic Current. (기존선 변전소에서의 고조파 발생현황과 저감설비 설치 효과 검토)

  • Park Sang-Ock;Lee Jong-Woo;Kwon Sam-Young;Lee Chang-Moo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1309-1315
    • /
    • 2004
  • The harmonic current originated from electric cars will be cause of electromagnetic interference along adjacent communication cables and troubles with signaling. It will also cause overheating in power capacitor and malfuction in protection relay. Therefore, it brought actual measurement of harmonic current by each operation mode. Because the result exceeded the value prescribed by Korea Electric Power Corporation, we constructed facilities reducing harmonic current on overloaded part at each power supply station located in conventional line (Guro, Kyungsan, and Milyang) as an optimal alternative. Then, this study compared and analyzed the reducing effect before and after constructing facility.

  • PDF

유도결합 플라즈마에서 임피던스 정합조건을 용한 비침투식 진단방법

  • Kim, Yeong-Do;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.202-202
    • /
    • 2013
  • 유도결합 플라즈마 방전 시 사용되는 L형 임피던스 정합기(impedance matcher)의 경우 일반적으로 직렬 및 병렬 콘데서가 연결되어있으며, 임피던스 정합조건이 되었을때 전원과 안테나 사이에 있는 임피던스 정합기의 소자값이 특정 값을 가지게 된다. 유도결합 플라즈마를 진단하기 위한 여러 방법들이 연구되어 왔지만, 이러한 임피던스 정합조건과 플라즈마 내부 변수들의 상관 관계에 대한 연구는 보고된 바 없다. 본 연구에서는 유도결합 플라즈마의 임피던스 정합조건과 유도결합 플라즈마의 변압기 회로모델를 이용하여 플라즈마 저항 및 플라즈마 인덕턴스를 구하기 위한 관계식을 도출하고 임피던스 정합기의 직렬 및 병렬 콘덴서 용량값 측정하여 플라즈마 저항 및 플라즈마 인덕턴스값을 계산하였다. 결과 검증을 위해 다양한 압력 및 전력 조건에서 부유랑뮤어 탐침법을 이용하여 플라즈마 밀도를 측정해 비교해 보았으며, 두 결과의 경향성은 잘 일치함을 확인하였다.

  • PDF