• Title/Summary/Keyword: 전력모니터링

Search Result 655, Processing Time 0.027 seconds

Media Access Control Protocol Considering MANET of Underwater Environment (수중 환경의 MANET을 고려한 매체 접근 제어 프로토콜)

  • Shin, Seung-Won;Yun, Nam-Yeol;Lee, Jin-Young;Lee, Seung-Joo;Park, Soo-Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.4
    • /
    • pp.97-107
    • /
    • 2013
  • Underwater wireless communication systems can be useful for underwater environment observation, catastrophe prevention, ocean resources exploration, ocean organism research, vessel sinking exploration, and so on. However, unlike terrestrial wireless communication, underwater wireless communication should consider factors such as long propagation delay, limited transmission capacity, high bit-error rate due to potential loss in power, ambient noise, man-made noise, multi-path, etc., because of the inherent characteristics of water. Thus, in this paper, we propose a suitable media access control(MAC) protocol that applies a combination of the ALOHA MAC protocol and the CSMA/CA MAC protocol to underwater environment. We further propose a mathematical analysis model to evaluate performance. We also verify performance improvement in the proposed scheme in comparison with existing MAC protocols.

Remote Power Management System for Large Scale PC Network (대규모 PC 네트워크의 원격 전원 관리 시스템)

  • Hwang, Kitae;Lee, Jae Moon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.4
    • /
    • pp.71-78
    • /
    • 2015
  • Since most education organizations such as Universities have a plenty of PCs, much electric power can be wasted if their power states are not managed properly. This paper introduces the RPM(Remote Power Management) software system implemented to reduce a waste of PC power in Universities. The System manager can monitor power state of all PCs in a University and turn off PCs or change power states of PCs to low power states. The RPM consists of three software modules. First, Power Controller, which is installed in each user PC, saves the power by changing low power state by utilizing low power algorithm proposed in this paper. Also it reports power state of its PC to Power Server on the state changed. Second, Power Server module gathers power state information of all PCs, stores them in a DB, and sends all or some parts of the information to Power Viewer whenever the manager asks. The manager can turn off or change a certain PC to low power state. We evaluated the performance of power saving for the RPM and the result showed achievement of 40% power saving.

The Study on Smart Farm of Apple Mango with Energy-mix Hybrid (애플망고 농가의 에너지-믹스 하이브리드 스마트 팜에 대한 연구)

  • Son, Jae Hwan;Lee, Seung Yong;Han, Chang Woo;Nah, Kyu Dong;Ha, Yu Shin
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.155-155
    • /
    • 2017
  • 최근 애플망고 스마트 농가에 에너지 사용량이 증가됨에 따라 에너지 절감을 위한 대책들과 화석연료를 대체하는 다양한 신재생에너지 도입에 대한 요구들이 늘고있다. 본 연구에서는 애플망고 스마트 농가에 여러 에너지원들을 혼합하여 사용할 수 있도록 실증시험 모델을 구축하고 운영함으로써 그 효용성을 검토하고자 하였다. 우선 애플망고 특성을 고려한 비닐온실의 최대 냉난방부하량과 에너지모델을 분석하여 신재생 에너지원들의 혼합 및 기존 공조설비와의 연계를 계산하였다. 애플망고 시험 농지로는 재배에 적합한 제주도 서귀포를 선정하였으며, 기존의 경유 난방기를 사용하는 비교시험 하우스, 기존의 경유와 태양광, 지하 공기 히트펌프 난방기를 혼합하여 사용하는 실증시험 하우스, 경유와 지하공기 히트펌프 난방기를 사용하는 대조시험 하우스를 10~11월 두 달간 운영하여 그 결과들을 평가하였다. 온실 내외부에 온도, 습도, CO2를 측정할 수 있는 6점의 센서부들을 설치하였고, 적산 전력계와 유량계를 설치하여 데이터를 수집하였으며, 모든 시험 데이터는 모바일 원격으로 제어 및 모니터링이 가능하도록 구성하였다. 시험 결과, 각 하우스들에서 수확한 과실의 수량과 품질은 유사하게 평가되었지만, 실증시험 하우스의 난방비가 비교시험 하우스보다 절감되었다. 하지만 실증시험 하우스의 경우 높은 시설유지비로 인해 이를 고려한 사용료는 비교시험 하우스보다 더 비싸게 평가되었다. 본 연구를 통해 생산된 잉여전력을 매전할 때 이로 인한 이용비는 비교시험 하우스보다 더 경제적임을 확인할 수 있었다. 또한 기존의 경유와 지하공기 히트펌프 난방기를 혼합한 대조시험 하우스의 난방비용이 경제성에서 더 유리함을 알 수 있었다. 따라서 본 연구를 통해 애플망고 스마트 농가에 적합한 에너지-믹스 모델을 구축할 수 있었으며, 다양한 신재생에너지들의 효용성들을 검토할 수 있었다.

  • PDF

Development of Distribution Superconducting Fault Current Limiter and its Monitoring System for Power IT Application (배전급 초전도한류기 및 전력 IT 응용을 위한 실시간 모니터링 시스템 개발)

  • Park, Dong-Keun;Seok, Bok-Yeol;Ko, Tae-Kuk;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.398-402
    • /
    • 2008
  • Recently, the development of superconducting fault current limiters (SFCLs) has been required as power demands increase in the power system. A distribution-level prototype resistive SFCL using coated conductor (CC) has been developed by Hyundai Heavy Industries Co., Ltd. and Yonsei University for the first time in the world. The ratings of the SFCL are 13.2kV/630A at normal operating condition. A novel non-inductive winding method is used in fabricating coils so there is almost zero impedance during normal operation. The distribution SFCL is cooled by sub-cooled liquid nitrogen $(LN_2)$ of 65K and 3 bar to enhance cryo-dielectric performance, critical current density, and thermal conductivity. In order to make reliable operation of an SFCL in real power systems, we monitored and controled its operation conditions by using supervisory control and data acquisition (SCADA) method. Thus, a monitoring system for the SFCL employing information technology (IT) is proposed and developed to be on the lookout for the operation conditions such as inside temperature, inside pressure, $LN_2$ level, voltage and current. Since operation temperature should be kept constant, bang-bang control for temperature feedback with a heater attached to the cold head of cryo-cooler is applied to the system. Short-circuit tests with prospective fault current of 10kA and AC dielectric withstand voltage tests up to 143kV for 1 minute were successfully performed at Korea Electrotechnology Research Institute. This paper deals with the development of a distribution level SFCL and its monitoring system for reliable operation.

Reliable Transmission of Bio-Data for IEEE 11073 PHD Standards at 6LoWPAN Multi-Hop Wireless Sensor Networks (6LoWPAN 멀티-홉 무선 센서 네트워크에서의 IEEE 11073 PHD 표준을 위한 신뢰성 있는 생체 정보 전송)

  • Woo, Yeon Kyung;Park, Jong Tae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.116-123
    • /
    • 2013
  • In mobile healthcare applications, the reliable transmission of the bio-data is very important. In this article, we present a reliable bio-data transmission technique for mobile healthcare monitoring service at 6LoWPAN multi-hop wireless networks. In particular, we expand IEEE 11073-20601 protocol, and propose the reliable path construction for 6LoWPAN aimed to reliably provide mobile healthcare service over wireless sensor network, using IPv6 network. 6LoWPAN is recognized possibility because it is agree with sensor network by raising Adaptation layer on the MAC layer to transmit IPv6 packets. In this article proposed minimize the algorithm complexity and reliability routing protocol because the 6LoWPAN devices are suitable for low cost, small size and battery that can be used to health care system environment. And detailed procedures and algorithms are presented. We the proposed method to prove the superiority of using NS-3 for compareing with AODV protocol.

Characteristic Analysis of Hybrid Desiccant Cooling System for District Heating in Residential Environment (지역난방에 연계된 하이브리드 제습냉방시스템의 주거환경에서의 성능 분석)

  • Ahn, Joon;Kim, Jaeyool;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.7
    • /
    • pp.571-579
    • /
    • 2014
  • A series of field tests on hybrid desiccant cooling systems were conducted in July-August, 2013. The temperature and humidity of the supply and return air, power, and heat consumption were monitored and transferred in real time through the Internet. The performance parameters of the cooling system, namely, cooling capacity and COP (coefficient of performance), were evaluated from the measured data and their variations under outdoor conditions was analyzed. It was found that with increase in the outdoor temperature, the total energy decreases and cooling capacity increases whereas the latter decreases with increase in the outdoor humidity. The COP was also found to increase with the increase in outdoor temperature.

A Study on Monitoring the Progressive Tax-based Power Charges Reduction Effects by Applying Fiber-based Artificial Vegetation System to Obsolete Houses (섬유기반 녹화시스템 적용에 따른 노후주택의 누진세기반 전력요금 저감효과에 대한 모니터링 연구)

  • Kim, Tae-Han;Lee, So-Dam
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.6
    • /
    • pp.67-77
    • /
    • 2017
  • Demands for housing has diversified recently due to low birth rate and the growth of aging population. Also, a share of idle houses and obsolete houses over 20 years old is gradually rising. Therefore, there is a need for a sustainable, environment-friendly improvement policy that is in line with a new housing paradigm and avoids full-scale new construction, such as a customized housing renovation plan considering local economic circumstances. Therefore, afforestation system applicable to buildings are assessed positively, but lack objective performance evaluation. Through one-year, long-term monitoring of replicated obsolete buildings that have poor insulation performance, this study calculated monthly average power consumption and analyzed power charges by applying pricing plans before and after the revision of progressive tax in order to examine economic effects expected by applying the afforestation system. In the obsolete buildings, the study showed that monthly average power consumption was reduced by 16.6kWh with 5.2% average reduction rate. Highest reduction was made in July at 11.3%. Aggregate monthly power consumption charges were relatively high in winter before and after the revision of progressive tax. Power charges reduction effect was highest in March when monthly power consumption was reduced to 300kWh level by applying the afforestation system.

Experimental Study for Overtopping Performance and Control System of Overtopping Wave Energy Convertor (월류 파력 발전 구조물 통합 축소 모형 시험을 통한 월류 성능 및 제어 시스템에 관한 실험적 연구)

  • Park, J.Y.;Shin, S.H.;Hong, K.Y.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 2011
  • Wave overtopping reef system with guide vanes convert incident wave energy on the reef type structures into electric power. Previous studies decided shape parameters likes slope, height of the sloping arm and shape of guide vane. In this paper, using these shape parameters produce 1/7 scale model and construct integration scale model system combining water pressure head turbine, power generation, power control, operating control and monitoring system. In these systems, we measure the overtopping and power generation with different wave heights and periods and compare the results with the previous studies. This was confirmed designed overtopping and power generation, then we suggest efficient control system.

A Study on Receiver Sensitivity Measurement using Pilot $E_c/I_o$ Compensation Method at CDMA Communication Network (CDMA 기지국에서 Pilot $E_c/I_o$ 보상기법을 이용한 수신감도 측정에 관한 연구)

  • Jeong, Ki-Hyeok;Ra, Keuk-Hwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.8
    • /
    • pp.9-16
    • /
    • 2007
  • Currently, the measurement of RF parameters for a base station in operation is typically limited to easily measured forward path items. In this paper, the forward monitoring ports of base stations are used to measure the reverse RF performance. The system has been implemented and effectiveness has been proven on an operating base station. The receiver sensitivity is measured using an internal CDMA modem which is used to monitor the output power based on closed loop power control when the modem is connected to the base station via a voice call. In order to improve accuracy, in addition to the modem Tx adjust(TxAdj) parameter, the detector's actual measurement is used. For accurate receiver sensitivity, the measurement should be made when there is no traffic which is not possible on an operating base station. Therefore, pilot channel chip energy to received signal power spectral density ratio$(E_c/I_o)$ compensation method is used to offset the receiver sensitivity degradation with voice traffic increase.

A Study of Environment Monitoring System based on Sensor Network (센서 네트워크를 이용한 실내 공기질 관리 및 제어에 관한 연구)

  • Kim, Ki-Tae;Kim, Dong-Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.389-392
    • /
    • 2010
  • The problem for the air pollution in the office or the indoor except a specific working area is the continuously issue since the human beings have lived in the dwelling facilities. Measures for that problem are urgently needed. It's possible to solve for the freshair of outside with enough ventilation but that is the awkward situation to be managed by person. It's feasible to supervison and control easily if you use to sensor network under the network. It works out to sense, storage, process, deliver every kind of appliances and environmental information from the stucktags and sensors. And it is possible to utilize to measure and monitor about the place of environmental pollution which is difficult for human to install. It's studied constantly since it be able to compose easily more subminiature, low-power, low-cost than previous one. And also it spotlights an important field of study, graft the green IT and IT of which the environment and IT unite stragically onto the Network. This study compose a IAQM(Indoor Air Quality Management) under the network, suggest the application of supervision and control.

  • PDF