• Title/Summary/Keyword: 전도노이즈

Search Result 75, Processing Time 0.029 seconds

A Switching Technique for Common Mode Voltage Reduction of PWM-Inverter System using the DSP320F240 (DSP320F240을 이용한 PWM-Inverter구동 시스템에서의 전도노이즈 저감을 위한 스위칭 기법)

  • Park Hyun Seok;Park Kyu Hyun;Kim Lee Hun;Han Sung Yong;Won Chung Yuen;Kim Young Real
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.355-359
    • /
    • 2002
  • Much attention has been given to EMI effects created in variable speed ac drive system. Zero switching states of inverter control invoke large common mode voltage. This paper focuses on the switching techniques to mitigate common mode voltage. This paper proposes a common-mode voltage reduction method based on sinusoidal pulse width modulation in three phase PWM inverter system. By using three carriers wave displaced by 120 degrees, it is possible to eliminate a common mode voltage pulse In one control period. Simulation and experimental results show that common mode voltages In the proposed technique are reduced more than conventional technique.

  • PDF

The Design Criteria and Conduction Noise Reduction of Electronic Ballasts (전자식안정기의 설계기준 및 전도노이즈 저감)

  • 권진욱;최인식;박영진;윤덕종;홍순찬
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.3
    • /
    • pp.409-419
    • /
    • 1994
  • This paper deals with the design criteria and conduction noise reduction of electronic ballast system which is based on half-bridge series inverters. The system is theoretically analyzed in six modes and operating frequency range is selected to obtain the high efficacy and no sound noise. It is proposed the criteria for determining the values of L and C which are the dey points in system design Because of high operating frequency, electromagnetic noise, especially conduction noise, is a serious problem in electronic ballasts. To reduce the conduction noise, the operation and attenuation characteristics of noise filter are analyzed and the method to determine the values of filter elements is proposed. Also, the parasitic components of the inductor and capacitor are taken into consideration in filter analysis. Digital simulations and experiments are carried out to prove the theoretical results. And perfor mances of the system are verified through tests.

Conducted EMI reduction of Induction Motor Drive System by PWM switching technique (PWM 스위칭 기법에 의한 유도전동기 구동시스템의 전도노이즈 저감)

  • Chun, Kwang-Su;Lee, Won-Cheol;Kim, Lee-Hun;Kim, Soo-Seok;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.540-545
    • /
    • 2004
  • Conventional SVPWM method has null switching vectors. Null switching vectors cause common-mode voltage making high in induction motor drive system. New SVPWM method without using null switching vectors are proposed in the paper. So, new SVPWM method reduces the common mode voltage for induction motor drive system. It is realized by changing software without adding hardware to induction motor drive system. Simulation results show that common-mode voltage adapting proposed method are reduced regarding conventional method.

  • PDF

A Switching Technique for Common Mode Voltage Reduction of 2-Level Inverter (2-레벨 인버터의 전도노이즈 저감을 위한 스위칭 기법)

  • Yun Hwan-Kyun;Kim Lee-Hun;Kim Jun-Ho;Won Chung-Yuen;Choi Ki-Soo;Bae Joung-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.434-437
    • /
    • 2001
  • Much attention has given to EMI effects created by variable speed ac drive system. This paper focuses on the switching technique to mitigate common mode voltage. Zero switching states of inverter control invoke large common mode voltage. Using inversed carrier wave, zero switching states are removed. In addition, proposed technique is easy to apply to existing 2-level inverter design. Simulation results show that common mode voltages adapting proposed technique are reduced regarding conventional method.

  • PDF

Conducted Noise Reduction in Random Pulse Width Modulation (Random PWM 기법에 의한 전도노이즈)

  • Jung, Dong-Hyo;Kim, Sang-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.98-101
    • /
    • 2002
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. These features are brought by the ON-OFF operation of semiconductor switching devices. However, this switching operation causes the surge and EMI(Electromagnetic Interference) which deteriorate the reliability of the converter themselves and entire electronic systems. This problem on the surge and noise is one of the most serious difficulties in AC-to-DC converter. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. A RPWM control method was proposed in order to smooth the switching noise spectrum and reduce it's level. Experimental results are verified by converter operating at 300V/1kW with 5%${\sim}$30% white noise input. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with USN. which are connected to the spectrum analyzer respectively.

  • PDF

A Switching Technique for Common Mode Voltage Reduction of PWM-Inverter Induction Motor Drive System Using TMS320F240 (TMS320F240을 이용한 PWM 인버터 유도전동기 구동 시스템의 전도노이즈 저감을 위한 스위칭 기법)

  • 박규현;김이훈;원충연;김규식;최세완;함년근
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.89-97
    • /
    • 2003
  • High frequency common mode voltage produced by PWM inverter fed Induction motor is a major cause of conducted EMI, creation motor ground currents, bearing currents and other harmful products. The zero switching states of inverter control invoke large in comparison with the non-zero switching state of Inverter control. We proposed a common mode voltage reduction method based on sinusoidal PWM technique. PWM signal are generated by comparing respective sinusoidal reference signal with three triangular carrier wave displaced of 120$^{\circ}$. Simulation and experimenta1 result show that common mode voltages in the proposed PWM technique are reduced by approximate 66% more than conventional FWM technique.

Study on the High-Frequency Circuit Modeling of the Conducted-Emission from the Motor Drive System of an Electric Vehicle (전기자동차 모터 구동 시스템의 전도 방출에 관한 고주파 모델링 연구)

  • Jung, Kibum;Lee, Jongkyung;Chung, Yeon-Choon;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.1
    • /
    • pp.82-90
    • /
    • 2013
  • In this paper, conducted emission from the MDS(Motor Drive System) of a HEV/EV was analyzed using high- frequency circuit modeling in system-level approach. The conducted emission by PWM process can cause RFI(radio- frequency interference) problems in the AM/FM frequency range. In order to mitigate this conducted emission, a high-frequency equivalent circuit model is proposed by analyzing the fundamental circuits, parasitic components in their parts and connections and non-linear characteristics of IGBTs, high-power capacitors, inverters, motors, high-power cables, and bus bars which are composed of the MDS. It is confirmed that the simulated result by the proposed model is well agreed with measured results in spite of a large-scaled analysis in system level. We are looking forward that this approach can be effectively used in the EMC design of HEV/EV.

EMC Compatibility Analysis of CEU EMC test results in the Optical Satellite System (광학위성 카메라전자부 EMC 시험결과의 시스템 양립성 검토)

  • Jang, Jae-Woong;Kim, Tae-Yoon;Lim, Seong-Bin;Moon, Guee-Won
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.161-167
    • /
    • 2010
  • CEU(Camera Electronic Unit) loaded in optical satellite for a high resolution image acquisition is composited with CC(Camera Controlloer), FPA(Focal Plane Assembly) and CEUP(CEU Power supply). EMC test and analysis results are explained in this paper. CE, CS, RE and RS test is performed in the 1st EMC test, RE, RS test which is not complied and influence considerably after shielding structure is performed in the 2nd EMC test. An effect due to the noise of CEU in the GPS/S-band receiving band is analyzed based on 2nd EMC test results. Margin more than 6dB is guaranteed when CEU is shielded.

Design of Long Distance Cable and Filter considering the Subsea Environment (심해저 환경을 고려한 장거리 케이블 및 필터 설계)

  • Kwon, Hyeok-Joon;Kim, Byeong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.5105-5114
    • /
    • 2013
  • This paper is conducted a research of the cable and filter design considering the deep sea floor environment. The electric architecture which is being used in the subsea plant is comprised of the power supply unit of the high voltage, high-capacity drive system, long cable, and electric motor in the sea area. Conducted emission is occurred by the rapid voltage change at the moment of switching at high speed of inverter for driving motors. The more the length of the cable is lengthened, the worse the motor is influenced by transient voltage. Thus, the over voltage occurred in the drive motor was confirmed by designed wire which is considered R, L, line-to-line C, line-to-gnd C of long cable used in the subsea plant. A guide line of the subsea plant model is also suggested by using a filter to reduce conducted noise of PWM inverter drive-system.

Study of Shield Method for EMC of Digital Circuit (디지털 회로에서 EMC를 위한 실드 방식에 대한 고찰)

  • Lee, Seong-Jae;Kim, Jae-Yang;Kim, Cheol-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.521-522
    • /
    • 2008
  • 21세기를 접하면서 산업전자 분야의 비약적인 발전과 함께 과학문명은 눈부시게 발전해 나아가고 있다. 이것의 원천은 바로 전기(Electric)이다. 우리는 풍요로운 삶 자체를 전기 공급에서 누리고 있으며 또 비극적인 사태를 맞이할 때도 있다. 즉, 전기기기를 이용하면 원하건 원치 않건 전자기파가 발생이 된다 이것이 자연현상이며 전자기파는 IT, BT, CT를 비롯하여 산업 전체에 많은 영향을 미치고 있다. 일반적으로 우리가 말하는 전자기파 장해의 기본 요소는 노이즈원(잡음원), 경로매체, 피해장치 등으로 구성되는 데 잡음원(Noise Source)은 각종 시스템에서 구성되고 있는 전자기 에너지의 발생원으로 볼 수 있으며 이 발생원에서 경로매체(금속:전도성, 대기중:전파성 등)를 통하여 피해장치(전기전자통신기기류)에 방해를 주고 있는 상태를 전자기파 장해라고 설명할 수 있다. 전자기파 잡음원에서 경로를 거쳐 전자기파에 대하여 피해장치가 안정된 상태로 동작하도록 규정하는 용어 즉, 전자파 양립성 또는 적합성 (EMC : Electro Magnetic Compatibility))이란 용어를 가지고 전기 전자 통신기기에서 발생되는 불필요한 전자파와 전자파 내성시험을 만족하도록 의무화하고 있다. EMC 는 EMI (불요 전자파 또는 전자파 간섭 : Electro Magnetic Interference) + EMS (전자파 내성 : Electro Magnetic Susceptibility) 2가지 시험을 함께 전자파 적합성 (EMC) 시험으로 표현되고 있다. 전자파 적합성 시험의 목적으로 EMl는 전도성 또는 전파성에 대한 주파수 대역(잡음)을 보호하기 위한 것이 목적이고 EMS는 프로세서가 내장된 기기류의 오동작을 방지하기 위하여 감응평가를 하는 것이다. 즉, 감응(Susceptibility)이란 어떤 장비나 시스템이 전자기파 장해에 쉽게 영향을 받는 것을 뜻하는 데 전자파 장해를 견디면서 본래의 기능을 충분하게 발휘하며 동작할 수 있는 능력을 말한다.

  • PDF