• Title/Summary/Keyword: 전도거리

Search Result 141, Processing Time 0.033 seconds

Development of Drainage Water Disinfection System by Electric Shock in Recirculating Soilless Culture (순환식 수경재배에서 배액의 전기충격살균법 연구)

  • Lee, Mun Haeng;Kim, Sung Eun;Lee, Sang Don;Lee, Jae Eun;Kim, Hak Sun;Cho, Suk Keong;Sim, Sang Youn;Kim, Young Shik
    • Journal of Bio-Environment Control
    • /
    • v.25 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • This study was conducted to develop the disinfection system using electric shock for recycled nutrient solution in recycling soilless culture. Stainless steel (SUS 316) was found as the most appropriate electrode material for electrical disinfection system from the view of high electrical conductivity, low electric resistance, and low price. There were no changes in nutritional elements when the electric shock passed through the nutrient solution by stainless steel electrode. The amount of electric current increased with width than thickness of the electrode. The farther the distance between the electrodes was increased the time to reach out the aimed amount of current. The electric shock was applied to Ralstonia solanacearum and Fusarium oxysporum as representative bacteria and also fungi. Any of those pathogens were killed with the percentage of higher than 97% in the condition of 15VDC or 24VDC.

Uncertainty of Spacial Variation of Rainfall Measurement by Point Raingauge (지점 강수량계에 의한 강우 공간분포 측정의 불확실성)

  • Kim, Won;Kim, Jong Pil;Kim, Dong Gu;Lee, Chan Ju
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.30-30
    • /
    • 2015
  • 유역에 내린 강우의 총량은 홍수나 갈수 측면에서 매우 중요하다. 점 강우량에 의해 측정된 강우량을 이용하여 유역 총강우량으로 환산하는 과정에 많은 오차가 포함되어 있다. 선행연구에 따르면, 우량계를 통한 강우관측에서 언더캐치(undercatch)에 의한 계통오차는 일반적으로 5~16%, 우연오차는 약 5%가 발생된다고 보고하였으며, 점 우량계 자료를 내삽하여 공간자료로 변환할 경우 0.1km 규모에서 표준오차가 4~14%, 1km 규모에서는 33~45%, 10km 규모에서는 약 65% 정도 발생된다고 한다. 이러한 우량계 관측오차 및 강우자료 처리과정에서 발생되는 오차는 유역의 유출량 계산에 영향을 주어 홍수예보 정확도를 크게 떨어뜨릴 수 있다. 우리나라에서는 지금까지 유역 총강우량 산정 측면에서 지점강우량의 불확실성에 대한 연구가 많이 이루어지지 못하였다. 본 연구에서는 우리나라에서 주로 사용되고 있는 전도형 우량계를 이용하여 소규모 구역에서 관측되는 강우관측의 불확실성을 분석하고자 하였다. 연구에 사용된 우량계는 0.5mm 급 표준 전도형 우량계로 정밀도는 시간당 1~100mm 기준으로 ${\pm}1%$를 기록하여 기상검정규격인 ${\pm}3%$를 만족하고 있다. 이 우량계는 한국건설기술연구원 안동하천실험센터 내에 장애물이 없는 평지에 60m 간격으로 총 6대($2{\times}3$)를 설치하여 2014년 7월 11일부터 9월 2일까지 54일간 관측을 수행하였다. 관측기간 동안 2대의 우량계가 수일동안 강우가 기록되지 않아서 분석에서 제외하였다. 우량계 상호 간의 누적강우량(54일간)을 비교한 결과 2.5~25.5mm의 차이를 나타냈다. 강우강도별 강우량 합계를 비교한 결과 시간당 1mm 이상에서는 약 1%의 차이가 났으며, 시간당 15mm 이상에서는 7.4%의 차이를 나타내어 강도가 큰 강우사상에서 우량계 간의 관측오차가 더 크게 나타났다. 또한 우량계 상호 간의 상관계수를 분석한 결과, 우량계 간의 거리가 가까울수록 그리고 누적시간이 길수록 상관계수는 커지는 것을 확인할 수 있었다. 도출된 결과를 토대로 하면 앞서 언급한 바와 같이 점 우량계 자료를 내삽하거나 유역 또는 계산격자의 대푯값으로 사용하여 1시간 이하 단위로 유출모의를 할 경우 심각한 오차를 발생시킬 수 있음을 시사한다. 보다 신뢰성 있는 홍수예보와 효율적인 유역관리를 위해서는 점 중심의 강우 관측이 아닌 면적 우량에 대한 관측이 이루어져야 하며 이를 위한 기술의 개발이 필요하다.

  • PDF

Simulation of Groundwater Flow and Sensitivity Analysis for a Riverbank Filtration Site in Koryeong, Korea (경북 고령군 강변여과 취수 지역의 지하수 유동 모사 및 민감도 분석)

  • Won, Lee-Jung;Koo, Min-Ho;Kim, Hyoung-Su
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.2
    • /
    • pp.45-55
    • /
    • 2006
  • A 2-D unconfined flow model is developed to analyze annual variations of groundwater level and bank filtration rate (BFR) for an experimental riverbank filtration site in Koryeong, Korea. Two types of boundary conditions are examined for the river boundary in the conceptual model: the static head condition that uses the average water level of the river and the dynamic cyclic condition that incorporates annual fluctuation of water level. Simulations show that the estimated BFR ranges $74.3{\sim}87.0%$ annually with the mean of 82.4% for the static head boundary condition and $52.7{\sim}98.1%$ with the mean of 78.5% for the dynamic cyclic condition. The results illustrate that the dynamic cyclic condition should be used for accurate evaluation of BFR. Simulations also show that increase of the distance between the river and the pumping wells slightly decreases BFR up to 4%, and thereby indicate that it is not a critical factor to be accounted for in designing BFR of the bank filtration system. A sensitivity analysis is performed to examine the effects of model parameters such as hydraulic conductivity and specific yield of the aquifer, recharge rate, and pumping rate. The results demonstrate that the average groundwater level and BFR are most sensitive to both the pumping rate and the recharge rate, while the water level of the pumping wells is sensitive to the hydraulic conductivity and the pumping rate.

Development of Decompressed Dryer for Mushroom (버섯의 감압건조기 개발)

  • 김영민;김유호;조영길;최희석;조광환
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.267-272
    • /
    • 2003
  • 본 연구에서는 버섯의 건조시간을 줄여 건조 후 버섯의 품질을 향상시키기 위하여 버섯의 감압건조기를 개발하였으며 연구 결과는 다음과 같다. 가. 버섯의 감압건조기의 시작기를 제작하였고, 시작기의 구조는 건조실, 감압블로워, 흡ㆍ배기구 솔레노이드 밸브, 제습장치, 송풍기, 전기히터로 구성되어 있으며, 건조실의 내부 압력이 표준대기압-900hPa, 열풍온도는 상온에서 5$0^{\circ}C$까지 조절할 수 있도록 제작하였다. 나. 시작기를 이용하여 표고버섯을 대상으로 건조특성시험을 실시한 결과, 열풍온도 5$0^{\circ}C$, 건조실 내부압력 900-940hPa에서 건조시간은 11.5h으로 대기압과 비교하여 6.5h 단축되는 것으로 나타났다. 또한, 건조 전ㆍ후의 색차, 수축률, 복원률의 품위가 우수한 것으로 나타났으며 F-test 유의성 검증 결과, 5%의 유의수준에서 갓주름의 색차, 갓직경의 수축률, 복원률에서 유의차가 있는 것으로 나타났다. 다. 열풍온도 5$0^{\circ}C$, 건조실 내부압력 900-940hPa로 표고버섯과 아가리쿠스에 대하여 건조성능시험을 실시한 결과, 표고버섯의 경우 건조시간은 13h으로 열풍식 농산물 건조기와 비교하여 건조시간이 4.5h 단축되는 것으로 나타났으며, 아가리쿠스의 경우 건조시간이 17.5h로 나타났다. 라. 성능시험 결과, 시작기가 열풍식 농산물건조기와 비교하여 건감률, 색택, 수축률, 복원률 등의 품위가 전반적으로 우수한 것으로 나타났다. 마. 시작기의 건조비용을 분석한 결과, 건조시간은 단축되었지만 시설투자비가 높아 건조비용이 표고버섯의 경우 2,461원/kg으로 열풍식 농산물건조기 보다 13% 높은 것으로 나타났지만, 추후 고품질 건조버섯 생산을 위한 기초자료로 활용이 가능할 것으로 판단된다.라갈수록 낮은 온도분포를 나타내고 있는 것은 상부에는 외부공기가 유입되면서 온도가 떨어지는 반면 하부에는 외부공기 유입이 적기 때문으로 사료된다. 또한 열풍실의 길이방향 위치별 온도 분포에서도 같은 현상으로 나타났고, 버너쪽과 송풍기쪽의 온도편차는 나타나지 않아 균일 건조를 기대할 수 있다. 마. 열풍온도를 45$^{\circ}C$로 설정하고 조사거리와 방사체 길이를 각각 119, 1,470mm로 하여 벼의 건조성능시험을 열풍건조기(대비구)와 비교시험 결과 시험구에서 건감률, 건조소요에너지가 각각 0.58%(w.b.), 470kcal/kg - water로 대비구보다 각각 건감율은 23% 높았고, 건조소요에너지는 2%의 절감되었다. 바. 건조기에서 발생되는 소음은 버너쪽 근처에서는 대비구 94.12㏈의 87%에 불과하였으나, 거리가 멀어질수록 차이는 크지 않았다. 이것은 버너에서 멀어질수록 외부적인 요인이 소음에 영향을 미쳤기 때문인 것으로 생각된다. 사. 시작기와 대비구간의 경제성에서 시작기의 구입가격이 20% 비싸기 때문에 시간당 고정비가 높았으나, 건조성능이 우수하여 건조비용이 69,350원/톤으로 대비구보다 14% 절감되는 것으로 나타났다.작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성 물질로 증착시키지 않고, Silver Paint 에 시편을 접착하는 방법으로도 만족한 시험 결과를 얻을 수 있었다.째, 회복기 중에 일어나는 입자들의 유입은 자기폭풍의 지속시간을 연장시키는 경향을 보이며 큰 자기폭풍일수록 현저했다. 주상에서 관측된 이러한 특성은 서브스톰 확장기 활동이 자기폭풍의 발달과 밀접한 관계가 있음을 시사한다.se that were all

  • PDF

Assessment of Effects of Groundwater Pumping from Deep Aquifer on Streamflow Depletion (죽산천 주변 암반층 지하수 양수로 인한 하천수 감소 영향 분석)

  • Lee, Jeongwoo;Kim, Nam Won;Chung, Il Moon;Cha, Joon Ho
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.9
    • /
    • pp.769-779
    • /
    • 2015
  • The streamflow depletion due to groundwater pumping from deep aquifer near the Juksan stream has been simulated, in this study, by using the surface water and groundwater integrated model, SWAT-ODFLOW in order to analyze the relationship between the stream depletion and hydraulic properties of aquifer and streambed, and to spatially assess the streamflow depletion. The simulated results showed that the streamflow depletion rate divided by the pumping rate for each well location ranges from 10% to 90% with reflecting the various well-stream distance, transmissivity, storativity, and streambed hydraulic conductance. In particular, the streamflow depletion exceeds about 50% of pumping rate for conditions with transmissivity higher than $10m^2/day$ or storage coefficient lower than 0.1. The simulated results in the form of spatial maps indicated that the spatially averaged percent depletion of streamflow is about 53.6% for five years of pumping which is lower than that for shallow aquifer pumping by 12.9%. From the spatially distributed stream depletion, it was found that higher and more rapid stream depletion to pumping occurs near middle-downstream reach.

Evaluating Applicability of Hunt's Analytical Solution for Groundwater Pumping from a Leaky Aquifer (누수대수층 지하수 양수에 관한 Hunt 해석해의 적용성 평가)

  • Lee, Jeongwoo;Chung, Il-Moon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.555-561
    • /
    • 2020
  • In this study, the applicability of Hunt's analytical solution for a two-layered leaky aquifer system, which was developed to estimate stream depletion due to the groundwater pumping of the upper shallow aquifer, was evaluated. The 5-year averaged stream depletions were estimated using Hunt's analytical solution for various combinations of hydraulic characteristic values such as transmissivity, storage coefficient of the two aquifers, interlayer leakage coefficient, stream-well distance, hydraulic conductivity of the streambed, and stream width. Through comparison with the numerical solution accurately simulated with a MODFLOW groundwater flow model, the analytical solution derived by regarding the stream width as a point was evaluated. It was found that the error in the stream depletion calculated by the analytical solution can be reduced to less than 0.05 when the stream-well distance is greater than the stream width or when the stream depletion factor (SDF) is more than about 3,000 days. In addition, when the streambed hydraulic conductivity is less than 1 m/d, the hydraulic diffusion coefficient of the lower aquifer layer is less than 100 ㎡/d, the hydraulic diffusion coefficient ratio of the upper and lower aquifer layers is 5 or more, and the leakage coefficient between the layers is less than 0.0004 m/d, the overall analytical solutions were overestimated compared with the numerical solutions.

DC 반응성 스퍼터링법으로 증착한 TiN/Al, TiCN/Al 박막의 전기적.기계적 특성 및 내부식성 평가

  • Lee, Hyeon-Jun;Song, Pung-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.346-347
    • /
    • 2012
  • 최근 화석연료 대체 에너지원으로서 자동차용으로 연구 개발 및 응용되고 있는 고분자 전해질 연료전지(PEMFC: Proton exchange membrane fuel cells)에서 분리판(Bipolar Plate)은 스택 전체 무게의 80%, 스택 가격의 60% 정도로 가장 높은 비중을 차지한다. 분리판은 연료와 산화제를 공급해주는 통로 및 전지 운전 중에 생성된 물을 제거하는 통로 역할과 anode, cathode로서 전극 역할을 통해 스택 전력을 형성하는 핵심 기능과 전지와 전지 사이의 지지대 역할을 한다. 따라서 분리판은 전기전도성, 내부식성 및 기계적 특성이 우수해야함은 물론이고, 얇고 가벼우며 가공성이 뛰어나야 한다. 현재 가장 많이 사용되고 있는 금속 분리판 소재 중 스테인리스 스틸은 전기적, 기계적 특성 및 내부식성이 우수한 반면, 가격이 비싸고, 중량이 무거운 단점이 있다. 따라서 본 연구에서는 DC 반응성 마그네트론 스퍼터링법으로 전기적, 기계적 특성 및 내부 식성이 우수한 TiN, TiCN 박막을 스테인리스에 비해 중량이 1/3, 소재 단가가 1/4인 알루미늄 기판 위에 증착하여 박막 물성을 평가하였다. DC Power는 400 W, 기판과 타겟 사이의 거리는100 mm, 공정 압력은 0.5 Pa로 고정하였고, 3 inch의 지름과 순도 99.95%를 갖는 티타늄 타겟을 사용하였다. 공정 가스는 Ar을 주입하였으며, 질소와 탄소의 공급원으로는 질소($N_2$)와 메탄($CH_4$) 가스를 사용하여 챔버 내 주입혼합가스의 전체 유량을 50 sccm으로 고정시켰다. 증착된 박막의 전기적, 기계적 특성을 측정하였고, X-ray diffraction (XRD), Scanning electron microscope (SEM)을 이용하여 박막의 미세구조 및 표면 상태를 확인하였다. 또한, 내부식 특성을 평가하기 위해 potentiostatic, potentiodynamic 법을 이용하여 박막의 부식저항을 측정하였다. 증착된 TiN 박막의 경우 질소 함량의 증가에 따라 박막 증착속도는 감소하는 경향을 보였다. 이는 타겟 부근의 질소 라디칼 비율이 증가함에 따라 질화반응이 촉진된 것으로 생각된다. 또한, 증착된 TiN과 TiCN 박막은 반응성 질소 유량과 탄소 유량에 따라 각각 다른 미세구조를 가지는 것을 확인하였다. TiN과 TiCN은 NaCl형의 면심입방격자(FCC)로 같은 구조이며, 격자상수가 비슷하여 전율고용되어 TiCN을 형성하고, 탄소와 질소의 비에 따라 전기적 기계적 특성이 달라짐을 확인하였다.

  • PDF

Effect of Rocking Behavior of Isolated Nuclear Structures and Sampling Technique for Isolation-System Properties on Clearance-to-stop (면진 원전구조물의 전도거동과 면진시스템 특성에 대한 샘플링 기법이 정지거리에 미치는 영향)

  • Han, Min Soo;Hong, Kee Jeung;Cho, Sung Gook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.293-302
    • /
    • 2015
  • ASCE 4 requires that a hard stop be built around the seismic isolation system in nuclear power plants. In order to maintain the function of the isolation system, this hard stop is required to have clearance-to-stop, which should be no less than the 90th-percentile displacements for 150% Design Basis Earthquake (DBE) shaking. Huang et al. calculated clearance-to-stop by using a Latin Hypercube Sampling technique, without considering the rocking behavior of the isolated structure. This paper investigates the effects on estimation of clearance-to-stop due to 1) rocking behavior of the isolated structure and 2) sampling technique for considering the uncertainties of isolation system. This paper explains the simplified analysis model to consider the rocking behavior of the isolated structure, and the input earthquakes recorded at Diablo Canyon in the western United States. In order to more accurately approximate the distribution tail of the horizontal displacement in the isolated structure, a modified Latin Hypercube Sampling technique is proposed, and then this technique was applied to consider the uncertainty of the isolation system. Through the use of this technique, it was found that rocking behavior has no significant effect on horizontal displacement (and thus clearance-to-stop) of the isolated structure, and the modified Latin Hypercube Sampling technique more accurately approximates the distribution tail of the horizontal displacement than the existing Latin Hypercube Sampling technique.

Study on InGaAs/InGaAsP/InP Quantum-dot Molecules for Quantum Interference devices (양자간섭소자를 위한 InGaAs/InGaAsP/InP 양자점 분자구조 연구)

  • Kim Jin-Soak;Kim Eun-Kyu;Jeong Weon-G.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.2
    • /
    • pp.186-193
    • /
    • 2006
  • In this study, we analyzed the electrical and optical properties of metalorganic chemical vapor deposition grown InGaAs/InGaAsP/InP quantum dot(QD) molecules by using photoluminescence and deep-level transient spectroscopy. From these resulte, the energy levels of the large QDs are located at deeper region from the conduction band edge of the barrier than that of the small QDs, The large QDs seem to have the energy states more than two, and these energy levels of the QD molecules are located at 0.35, 0.42, and 0.45 eV from conduction band edge under -4 V reverse bias conditions. The energy levels are closely coupled under low reverse bias, and then decoupled as the bias voltage is increased.

Preparation and Electrochemical Properties of Polymeric Composite Electrolytes Containing Organic Clay Materials (Organic Clay가 첨가된 고분자 복합 전해질의 제조 및 전기화학적 성질)

  • Kim, Seok;Hwang, Eun-Ju;Lee, Jea-Rock;Kim, Hyung-Il;Park, Soo-Jin
    • Polymer(Korea)
    • /
    • v.31 no.4
    • /
    • pp.297-301
    • /
    • 2007
  • In this work, polymer/(layered silicate) nanocomposites (PLSN) based on poly (ethylene oxide) (PEO), ethylene carbonate (EC) as a plasticizer, lithium salt ($LiClO_4$), and sodium montmorillonite ($Na^+-MMT$) or organic montmorillonite (organic MMT) clay were fabricated. And the effects of organic MMT on the polymer matrix were investigated as a function of ionic conductivity. For the application to electrolytes an Li batteries, polymer electrolytes containing the organic nanoclays were used in this work. As a result, the spacing between layers and hydrophobicity of the organic nanoclays were increased, affecting on the exfoliation behaviors of the MMT layers in clay/PEO nanocomposites. From ion-conductivity results, the organic-MMT showed higher values than those of $Na^+-MMT$, and the MMT-20A sample that was treated by methyl dihydrogenated tallow ammonium, showed the highest conductivity in this system.