• Title/Summary/Keyword: 전달오차

Search Result 537, Processing Time 0.022 seconds

Motion Error Analysis of the Porous Air Bearing Stages Using the Transfer Function (전달함수를 이용한 다공질 공기베어링 스테이지의 운동오차해석)

  • 박천홍;이후상
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.185-194
    • /
    • 2004
  • In order to analyze the motion errors of the aerostatic stage, it is necessary to consider the influence of the moment variation occurred inside the pads. In this paper, a motion error analysis method utilizing the transfer functions on the reaction force and moment is proposed, and general characteristics of the transfer functions are discussed. Calculated motion errors by the proposed method show good agreement with the ones calculated by Multi fad Method, which is considered the entire table as an analysis object. Also, by the introduction of the transfer function of motion errors, which represent the relationship between the spatial frequency components of the rail form error and motion errors, motional characteristics of the porous aerostatic stage can be generalized. In detail, the influence of the spatial frequencies is analyzed qualitatively, and the patterns of the insensitive frequencies which almost do not affect the linear motion error or angular motion error according to the rail length ratio and the number of the pad are verified. The relationship between the moment variation occurred inside the pads and the motion errors is also verified together.

Study on the flame height definition in Forest (낙엽층의 화염높이 산정에 관한 연구)

  • Kim, Dong-Hyun;Tanaka, Takeyoshi;Lee, Myung-Bo;Kim, Kwanl-Il
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.365-371
    • /
    • 2009
  • 산불에 있어 화염높이 산정은 복사열전달에 의한 수평 또는 수직적 화염확산을 예측하는데 있어 매우 중요한 부분이다. 화염특성 중 화염높이는 빛을 수반하는 화염(the luminous flame)의 평균높이로 확인할 수 있다. 본 연구에서는 외부 풍속과 경사 등으로 인한 화염 높이가 변화될 수 있는 조건을 제외한 산림 내 지표연소물질인 낙엽층(fuel bed)에 대한 화염높이 관측실험과 Cone calorimeter(ASTM-1354)을 이용하여Heat Release Rate 측정하였고 surface fuel에 대한 화염높이 산출식 $H_f=0.027{\dot{Q}}^{2/3}$을 도출하였다. 실험값과 개발 산정식, 기존 Heskestad(1998) 식과의 적용값 비교 결과, 소나무 낙엽의 경우, 실험값과 개발 산정식 적용값의 표준오차는 0.08, 실험값과 기존 Heskestad(1998)의 표준오차는 0.23으로 개발 산정식의 정확성이 높은 것으로 나타났다. 따라서 앞으로 이 식을 이용하여 복사열전달에 의한 화염확산해석 및 화염의 높이에 따른 수관화 전이해석 등에 활용 가능할 것으로 사료된다.

  • PDF

Transmission Error Analysis of ZI and ZA Profile Worm Gears (ZI 및 ZA형 웜기어의 치합전달오차 해석)

  • Lee, Tae-Hoon;Suh, Junho;Park, Noh-Gill
    • Tribology and Lubricants
    • /
    • v.34 no.6
    • /
    • pp.325-331
    • /
    • 2018
  • Automobiles and systems requiring high gear ratios and high power densities generally use worm gears. In particular, as worm gears have a small volume and self-locking function, home appliances such as refrigerators and washers consist of worm gears. We can classify worm gears into cylindrical worms and rectangular worms. According to the AGMA standard, there are four types of cylindrical worms, ZA, ZN, ZK and ZI, depending on the machining of the worm shaft. It is preferable to use a ZI-type worm shaft, which is a combination of a worm wheel having an involute helical tooth surface and a conjugate tooth surface. However, in many cases, industries mostly use ZK, ZN, and ZA worm shafts because of the ease of processing. This paper presents numerical approaches to produce ZI and ZA worm surfaces and worm wheel. For the analysis of the transmission error of a worm gear system, this study (1) generates surface profile functions of ZI profile worm gear and worm shaft based on the common rack theory, (2) adopts the Newton-Raphson method for the analysis of the gear surface contact condition, and (3) presents and compares the corresponding transmission errors of ZI and ZA worm gears.

A Study on Response Analysis by Transmission Error of Yaw Drive for 8 MW Large Capacity Wind Turbines (8 MW급 대용량 풍력발전기용 요 감속기 치합전달오차에 따른 응답해석에 관한 연구)

  • Seo-Won Jang;Se-Ho Park;Young-kuk Kim;Min-Woo Kim;Hyoung-Woo Lee
    • Journal of Wind Energy
    • /
    • v.15 no.1
    • /
    • pp.43-49
    • /
    • 2024
  • This study performed a response analysis according to the transmission error of the yaw drive. To perform the response analysis, the excitation source of the transmission error was modeled and the outer ring of the first stage bearing and the outer ring of the output shaft bearing were used as measurement positions. The response results were analyzed based on the vibration tolerance values of AGMA 6000-B96. As a result of the response of the first stage bearing outer ring, the maximum displacement of the first stage planetary gear system was 5.59 and the maximum displacement of the second to fourth stage planetary gear systems was 4.21 ㎛ , 3.13 ㎛ , and 25.6 ㎛ . In the case of the output shaft bearing outer ring, the maximum displacement of the first stage planetary gear system was 1.73 ㎛, and the maximum displacement of the second to fourth stage planetary gear system was 1.94 ㎛, 0.73 ㎛, and 2.03 ㎛. According to AGMA 6000-B96, the vibration tolerance of first stage is 17.5 ㎛, and the vibration tolerance of the second to fourth stages is 58 ㎛, 80 ㎛, and 375 ㎛, which shows that the vibration tolerance is satisfied and it is safe.

Characteristics of the Point-source Spectral Model for Odaesan Earthquake (M=4.8, '07. 1. 20) (오대산지진(M=4.8, '07. 1. 20)의 점지진원 스펙트럼 모델 특성)

  • Yun, Kwan-Hee;Park, Dong-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.241-251
    • /
    • 2007
  • The observed spectra from Odaesan earthquake were fitted to a point-source spectral model to evaluate the source spectrum and spatial features of the modelling error. The source spectrum was calculated by removing from the observed spectra the path and site dependent responses (Yun, 2007) that were previously revealed through an inversion process applied to a large accumulated spectral dataset. The stress drop parameter of one-corner Brune's ${\omega}^2$ source model fitted to the estimated source spectrum was well predicted by the scaling relation between magnitude and stress drop developed by Yun et al. (2006). In particular, the estimated spectrum was quite comparable to the two-corner source model that was empirically developed for recent moderate earthquakes occurring around the Korean Peninsula, which indicates that Odaesan earthquake is one of typical moderate earthquakes representative of Korean Peninsula. Other features of the observed spectra from Odaesan earthquake were also evaluated based on the commonly treated random error between the observed data and the estimated point-source spectral model. Radiation pattern of the error according to azimuth angle was found to be similar to the theoretical estimate. It was also observed that the spatial distribution of the errors was correlated with the geological map and the $Q_0$ map which are indicatives of seismic boundaries.

Target Localization and Dose Delivery Verification used a Water Phantom in Stereotactic Radiosurgery (정위적 방사선 수술에서 물팬텀을 이용한 목표점 및 전달 선량확인)

  • Kang, Young-Nam;Lee, Dong-Jun;Kwon, Soo-Il;Kwon, Yang
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.19-28
    • /
    • 1996
  • It is important that the precise decision of the region and the accurate delivery of radiation dose required for treatment in the stereotactic radiosurgery. In this research, radiosurgery was carried with Leksell streotactic frame(LSF) which is especially developed water phantom to verify in experiment. Leksell Gamma Knife and LSF are used in radiosurgery is the spherical water phantom has the thickness of 2 mm, the radius of 160mm. The film for target localization and ionchamber for dose delivery was used in measurement instruments We compare the coordinate of target which is initialized by biplannar film with simple X-ray to the coordinate of film measured directly. The calculated dose by computer simulation and the measured dose by ionization chamber are compared. In this research, the target localization has the range ${\pm}$0.3mm for the acceptable error range and the absolute dose is :${\pm}$0.3mm for the acceptable error range. This research shows that the values measured by using the especially manufactured phantom are included the acceptable error range. Thus, this water phantom will be used continuously in the periodic quality assurance of Gamma Knife Unit and Leksell Stereotactic Frame.

  • PDF

Development of GPS Multipath Error Reduction Method Based on Image Processing in Urban Area (디지털 영상을 활용한 도심지 내 GPS 다중경로오차 경감 방법 개발)

  • Yoon, Sung Joo;Kim, Tae Jung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.2
    • /
    • pp.105-112
    • /
    • 2018
  • To determine the position of receiver, the GPS (Global Positioning System) uses position information of satellites and pseudo ranges based on signals. These are reflected by surrounding structures and multipath errors occur. This paper proposes a method for multipath error reduction using digital images to enhance the accuracy. The goal of the study is to calculate the shielding environment of receiver using image processing and apply it to GPS positioning. The proposed method, firstly, performs a preprocessing to reduce the effect of noise on images. Next, it uses hough transform to detect the outline of building roofs and determines mask angles and permissible azimuth range. Then, it classifies the satellites according to the condition using the image processing results. Finally, base on point positioning, it computes the receiver position by applying a weight model that assigns different weights to the classified satellites. We confirmed that the RMSE (Root Mean Square Error) was reduced by 2.29m in the horizontal direction and by 15.62m in the vertical direction. This paper showed the potential for the hybrid of GPS positioning and image processing technology.

Reduction of Chattering Error of Reed Switch Sensor for Remote Measurement of Water Flow Meter (리드 스위치 센서를 이용한 원격 검침용 상수도 계량기에서 채터링 오차 감소 방안 연구)

  • Ayurzana, Odgerel;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.42-47
    • /
    • 2007
  • To reduce the chattering errors of reed switch sensors in the automatic remote measurement of water meter a reed switch sensor was analyzed and improved. The operation of reed switch sensors can be described as a mechanical contact switch by approximation of permanent magnet piece to generate an electrical pulse. The reed switch sensors are used mostly in measurement application to detect the rotational or translational displacement. To apply for water flow measurement devices, the reed switch sensors should keep high reliability. They are applied for the electronic digital type of water flow meters. The reed switch sensor is just mounted simply on the conventional mechanical type flow meter. A small magnet is attached on a pointer of the water meter counter rotor. Inside the reed sensor two steel leaf springs make mechanical contact and apart repeatedly as rotation of flow meter counter. The counting electrical contact pulses can be converted as the water flow amount. The MCU sends the digital flow rate data to the server using the wireless communication network. But the digital data is occurred difference or won by chattering noise. The reed switch sensor contains chattering error by it self at the force equivalent position. The vibrations such as passing vehicle near to the switch sensor installed location causes chattering. In order to reduce chattering error, most system uses just software methods, for example using filter algorithm and also statistical calibration methods. The chattering errors were reduced by changing leaf spring structure using mechanical characteristics.

Accuracy in target localization in stereotactic radiosurgery using diagnostic machines (정위적 방사선수술시 진단장비를 이용한 종양위치결정의 정확도 평가)

  • 최동락
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.3-7
    • /
    • 1996
  • The accuracy in target localization of CT, MR, and digital angiography were investigated for stereotactic radiosurgery. The images using CT and MR were obtained out of geometrical phantom which was designed to produce exact coordinates of several points within a 0.lmm error range. The slice interval was 3mm and FOV was 35cm for CT and 28cm for MR. These images were transferred to treatment planning computer using TCP/IP in forms of GE format. Measured 3-D coordinates of these images from planning computer were compared to known values by geometrical phantom. Anterior-posterior and lateral films were taken by digital angiography for measurement of spatial accuracy. Target localization errors were 1.2${\pm}$0.5mm with CT images, 1.7${\pm}$0.4mm with MR-coronal images, and 2.1${\pm}$0.7mm with MR-sagittal images. But, in case of MR-axial images, the target localization error was 4.7${\pm}$0.9mm. Finally, the target localization error of digital angiography was 0.9${\pm}$0.4mm. The accuracy of diagnostic machines such as CT, MR, and angiography depended on their resolutions and distortions. The target localization error mainly depended on the resolution due to slice interval with CT and the image distortion as well as the resolution with MR However, in case of digital angiography, the target localization error was closely related to the distortion of fiducial markers. The results of our study should be considered when PTV (Planning Target Volume) was determined.

  • PDF

Measurement of mass Transfer Coefficients for Adsorptive Bulk Gas Separation with Velocity Variations (기체속도가 변하는 벌크기체의 흡착공정에서 물질전달계수의 측정)

  • Min, Jun-Ho;Choi, Min-Ho;Suh, Sung-Sup
    • Applied Chemistry for Engineering
    • /
    • v.10 no.2
    • /
    • pp.310-318
    • /
    • 1999
  • The concentration breakthrough curves were examined to predict mass transfer coefficients of nitrogen and oxygen in adsorption column for design data of PSA process. Experimental breakthrough curves for bulk gas flow were compared with theoretical simulation results. For quantitative analysis of the adsorption, coupled Langmuir isotherm was considered and LDF model was used to describe the mass transfer effect. In the experimental and theoretical results, it was found that mass transfer coefficient was not affected by flow rate but strongly affected by pressure. As a result of this tendency, mass transfer resistance in this system was proved to belong to the macropore diffusion controlling region and the mass transfer coefficients could be expressed by exponential functions of pressure change. The mass transfer coefficients for one component, nitrogen or oxygen, were successfully applied to breakthrough curves for bulk mixed gases. The experimental curves were reasonably in consistent with the theoretical curves and the error time was less than 5 percent.

  • PDF