Elastic Shear Buckling Characteristics of Circularly Corrugated Plates (원형 파형 판의 탄성전단좌굴 특성)

  • Han, Taek Hee;Lim, Nam Hyoung;Park, Nam Hoi;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.4
    • /
    • pp.529-538
    • /
    • 2002
  • Applications of corrugated plates (or folded plates) have been recently increasing due to certain economic and structural advantages. Likewise, applications of corrugated plates has been increasing because they are stronger compared to flat plates. Therefore, specifications of corrugated plates should be determined. There are many design details in almost every specification for flat plates. However, except the bending strength and the normal strength, there are no detailed design guides such as shear strength. Thus, it is difficult for engineers to design structures consisting of corrugated plates. As such, engineers need a guide in designing corrugated plates. Extensive numerical study was conducted in order to identify the relationship between the shear strength and geometric conditions for corrugated plates. An eight-node thin shell element (QSL8) of the commercial program LUSAS (version 13.2) was used. The study was able to come up with a formula that helps determine the shear strength of corrugated plates under various geometric conditions, the size of corrugation, the curvature of corrugation, and the thickness of the corrugated plate. Likewise, corrugated plates were found to have a higher shear buckling strength than flat plates.

A Study on the Effect of Transversal Warping In Thick Plate (두꺼운 판의 전단 Warping 영향에 대한 연구)

  • Lee, Sang-Gab;Choi, Won-Joon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.1
    • /
    • pp.77-89
    • /
    • 1996
  • An enormous amount of efforts has been devoted to the development of finite elements for the bending problem of thick plates, especially based on Mindlin plate theory. Here, an approximate Constant Shear Angle Theory is usually used to take a transverse shear deformation of thick plate into consideration, which cannot be effectively considered the influence of transversal warping of cross-section with an increase of thickness. It might be the best way to represent the exact cross-sectional warping of the plate. The overall objective of this study is to develop a new formulation of plate including shear deformation and transversal warping, to perform extensive parametric studies comparing its results with those from Mindlin plate formulation, and to gain further insight into the influence of shear deformation and transversal warping of thick plate.

  • PDF

Experimental Study on Ultimate Shear Strength of Horizontally Curved Plate Girder Web Panels (강곡선 플레이트거더 복부판의 극한전단강도에 관한 실험연구)

  • Lee, Doo Sung;Park, Chan Sik;Lee, Sung Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.727-734
    • /
    • 2006
  • Although a limited number of experimental investigations and finite element analyses revealed that a curved web panel in practical design has a considerable reserve strength after the elastic buckling as a straight girder web panel, the current Guide Specifications for Horizontally Curved Steel Girder Highway Bridges (AASHTO, 2003) do not consider the postbuckling strength in the ultimate shear strength due to lack of a comprehensive study. In this study, the ultimate shear strength behavior of horizontally curved steel web panels was investigated through nonlinear finite element analysis and experimental test. It was found that curved web panels used in practical designs are able to develop the postbuckling strength that is equivalent to that of straight girder web panels having the same dimensional and material properties.

Lateral Resisting Behavior of Reinforced Concrete Shear Wall and Flat Plate Column (철근콘크리트 전단벽과 무량판 기둥의 횡저항 거동)

  • Kim, Tae-Wan;Min, Chan-Gi
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.14-17
    • /
    • 2010
  • 본 논문에서는 국내에서 주상복합건물에 주로 건설되는 철근콘크리트 전단벽과 무량판 골조 기둥 시스템의 횡저항 거동을 조사, 분석하였다. 이 시스템의 내진설계 시 건물골조시스템을 적용하게 되는데 전단벽 설계는 큰 어려움이 없으나 골조의 경우 변형의 적합성을 고려해야 할 경우에 상세하고 명확한 지침이 마련되어 있지 않아 그 적용이 쉽지 않다. 이를 해결하기 위하여 예제 건물을 선정하여 기준에 따라 설계한 후 비선형정적 해석을 수행하여 철근콘크리트 전단벽과 무량판 골조 기둥의 비선형 거동을 조사하였다. 그 결과 무량판 골조 기둥의 거동은 전단벽에 종속되었고 변형의 적합성을 고려하기 위해 골조의 모멘트를 증폭하더라도 기둥의 단면 변화가 크지 않으므로 실무적으로 큰 어려움이 없는 것으로 나타났다. 다만 강도뿐만 아니라 변형 능력에 대해서도 추가적인 연구가 필요하다.

  • PDF

Comparison of Shear Strength Equation for Flat Plates with GFRP Plate (GFRP 판으로 보강된 플랫 플레이트의 전단강도식에 관한 규준의 비교 분석)

  • Kim, Min Sook;Hwang, Seung Yeon;Kim, Heecheul;Lee, Young Hak
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.4
    • /
    • pp.247-254
    • /
    • 2014
  • In this study, shear test performed to investigate the shear behavior of flat plate that reinforced by embedded GFRP(glass fiber reinforced polymer) plate with openings. Shape of the GFRP shear reinforcement is a plate with several openings to ensure perfect integration with concrete. The test parameters include the distance between the column face and the first line of GFRP plate and number of GFRP plate vertical strip. The result of test showed that when number of GFRP plate vertical strip was increased, shear strength improved. The shear strength for flat plate reinforced GFRP plate in various codes including ACI 318, BS 8110, EUROCODE 2, and KCI were compared to provide more rational approach for reinforced concrete flat plates with GFRP plate.

Behavior of Steel-Concrete Composite Decks for PSC Girder Bridge with Various Shear Span Lengths (전단 지간의 변화에 따른 PSC 거더용 강-콘크리트 합성 바닥판의 역학적 거동)

  • Kim, Tae-Hyup;Park, Jun-Myung;Hong, Sung-Nam;Park, Sun-Kyu;Kim, Hyeong-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.275-281
    • /
    • 2007
  • Recently, steel-concrete composite structures are widely used in bridge and building constructions. In this paper, a new type of steel-concrete composite deck with profiled steel sheeting is proposed to replace the conventional cast-in-place reinforced concrete deck. Perfobond rib shear connectors were utilized to provide horizontal shear resistance between the profiled sheeting and the concrete. To validate the effectiveness of the proposed deck system, 8 full-scale deck specimens for PSC girder bridge were fabricated. The specimens were tested with four different shear span lengths to determine the horizontal shear resistance of the deck under a static monotonic loading. For comparison purpose, two reinforced concrete decks were also fabricated and tested. The horizontal shear resistance of the proposed deck system was calculated using the m-k method.

Fatigue strength of stud shear connector considering bedding layer thickness in precast deck composite bridges (프리캐스트 바닥판 합성형 교량에서의 베딩층의 두께를 고려한 전단연결재의 피로강도)

  • Ryu, Hyung Keun;Shim, Chang Su;Chung, Chul Hun;Chang, Sung Pil
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.1
    • /
    • pp.113-120
    • /
    • 2002
  • A shear connection in composite bridges with precast decks has considerable characteristics different from cast-in-place deck bridges such as shear pocket and bedding layer. Thus, it is necessary to build design basis of the shear connector in precast decks through the experiments. In order to estimate fatigue life of shear connector in precast deck bridges, push-out fatigue tests were conducted with parameter, bedding layer thickness. As a result of the tests, failure modes of shear connector were observed. Consequently, empirical S-N curve equations of stud shear connector in precast deck bridges were proposed in this paper.

Elastic Shear Buckling of Curved Web Panels (강곡선 1형보 복부판의 탄성 전단좌굴)

  • 김재석;김종헌;강영종;한택희
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.2
    • /
    • pp.95-104
    • /
    • 2004
  • The horizontally curved bridges have been used to connect bridges and roads. Until 1960s, they had been constructed with straight girders, called 'kinked girder bridges', which requires much cost and time-consuming construction of substructure. In case of using curved girders, practiced later, they would have many advantages such as reduction in the total construction cost and time, and ability to make aesthetic bridges. In designing plate girder bridges, it is necessary to determine the spacings between vertical stiffeners and the allowable shear stresses based on shear buckling capacity because it plays a key role in preventing the premature local shear buckling. Compared with the straight web, the critical shear buckling stresses of curved web panels vary with both aspect ratio and curvature coefficient. For designing curved web panels, a simplified formula and shear buckling coefficients were proposed by parametric models with F.E.M in this study.

Evaluation of Shear Strength for Reinforced Flat Plates Embedded with GFRP Plates (매립형 GFRP 판으로 보강된 플랫 플레이트의 전단강도 평가)

  • Hwang, Seung Yeon;Kim, Min Sook;Lee, Young Hak;Kim, Heecheul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.2
    • /
    • pp.121-128
    • /
    • 2014
  • In this study, The purpose of this study is to experimentally investigate the shear behavior of reinforced flat plate embedded with GFRP(glass fiber reinforced polymer) plate with openings. The GFRP shear reinforcement is manufactured into a plate shape with several openings to ensure perfect integration with concrete. The test was performed on 7 specimens. the parameters include the type of reinforcement and amount of the shear reinforcement., From the test, we analysed the crack, failure mode, Strain, load-displacement graph. a calculation of the shear strength of reinforced flat plate with GFRP plate based on the ACI 318-11 was compared with the test results. The results of the experiment indicate that GFRP plate is successfully applied as a shear reinforcement in the flat plate under punching shear.

A Study on Elastic Shear Buckling Coefficients of Horizontally Curved Plate Girder Web Panels (강곡선 플레이트거더 복부판의 전단좌굴계수에 관한 연구)

  • Lee, Doo-Sung;Lee, Sung-Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.367-373
    • /
    • 2008
  • In the design of horizontally curved plate girder web panels, it is required to evaluate accurately the elastic buckling strength under pure shear. Currently, elastic shear buckling coefficients of curved web panels stiffened by transverse intermediate stiffeners are determined by assuming conservatively that straight web panels without curvature are simply supported at the juncture between the flange and web. However, depending upon the geometry and the properties of the curved plate girder, the elastically restrained support may behave rather closer to a fixed support. The buckling strength of curved girder web is much greater (maximum 38%) than that of a straight girder calculated under the assumption that all four edges are simply supported in Lee and Yoo (1999). In the present study, a series of numerical analyses based on a 3D finite element modeling is carried out to investigate the effects of geometric parameters on both the boundary condition at the juncture and the horizontal curvature of web panel, and the resulting data are quantified in a simple design equation.